Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrated storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Sparse chronology strategy for integrating seasonal energy storage in capacity expansion models

Here, this study develops the sparse chronology method to enhance the representative period framework in capacity expansion models, enabling the effective integration of long-duration energy storage modeling. Traditional representative period methods cannot capture the state of charge of seasonal energy storage systems because they do not establish effective inter-day linkages to connect the state of charge between periods. The sparse chronology approach addresses this limitation by establishing inter-day linkages that allow state of charge to shift inter-seasonally. At the same time, it groups identical representative days into partitions, applying constraints sparsely and implicitly to reduce computational load further. Validation results demonstrate that this method successfully simulates long-duration energy storage patterns, achieving close alignment with a continuous yearly benchmark model, with seasonal trends and state of charge cycles clearly represented. The computational load analysis reveals that the sparse chronology method efficiently applies constraints on maximum and minimum state of charge limits within the representative day framework, eliminating the need for detailed constraints on each individual day. By partitioning representative days and constraining only the start and end of each partition, the method significantly decreases computational requirements. Simulation results show that sparse chronology closely approximates the continuous yearly method's accuracy, even with as few as 20 representative days, achieving correlation values with the benchmark of nearly 0.9 in state of charge plots. Furthermore, it maintains computational efficiency, requiring only 4 % of the solver time compared to the continuous yearly method with 20 representative days. This approach allows capacity expansion models to incorporate long-duration energy storage with high temporal, spatial, and technological resolution, enabling more detailed modeling for large-scale power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Refrigeration and Storage of LNG for Compositional Stability

Growing interest in liquefied natural gas (LNG) as a rocket fuel necessitates a greater technical understanding of the compositional changes due to preferential boil-off (or weathering) that occurs during long duration storage. The purity of methane in LNG can range from 90 to 98%, and is subject to preferential boil-off due to its low boiling point compared to other constituents despite the use of high-performance thermal insulation systems. Active heat extraction (i.e. refrigeration) is required to completely eliminate weathering. For future operational safety and reliability, and to better understand the quality and efficiency of the LNG as a cryofuel, a 400-liter Cryostat vessel was designed and constructed to measure the composition and temperatures of the LNG at a number of different liquid levels over long durations. The vessel is the centerpiece of a custom-designed lab-scale integrated refrigeration and storage (IRaS) system employing a pulse tube cryocooler capable of roughly 50 W of lift at 100 K. Instrumentation includes ten temperature sensors mounted on a vertical rake and five liquid sample tubes corresponding to five liquid levels. Two modes of operation are studied. The first is without refrigeration in order to determine a baseline in the change in composition, and to study stratification of the LNG. The second is performed with the cryocooler active to determine the operational parameters of the IRaS system for eliminating the weathering as well as stratification effects in the bulk liquid. The apparatus design and test method, as well as preliminary test results are presented in this paper. As a bonus in cost-saving and operational efficiency, the capability of the IRaS system to provide zero-loss capabilities such as zero boil-off (ZBO) keeping of the LNG and zero-loss filling/transfer operations are also discussed.

Rose, Laura P.↗

Integrated Refrigeration and Storage of LNG for Compositional Stability

Growing interest in liquefied natural gas (LNG) as a rocket fuel necessitates a greater technical understanding of the compositional changes due to preferential boil-off (or weathering) that occurs during long duration storage. The purity of methane in LNG can range from 90 to 98%, and is subject to preferential boil-off due to its low boiling point compared to other constituents despite the use of high-performance thermal insulation systems. Active heat extraction (i.e. refrigeration) is required to completely eliminate weathering. For future operational safety and reliability, and to better understand the quality and efficiency of the LNG as a cryofuel, a 400-liter Cryostat vessel was designed and constructed to measure the composition and temperatures of the LNG at a number of different liquid levels over long durations. The vessel is the centerpiece of a custom-designed lab-scale integrated refrigeration and storage (IRaS) system employing a pulse tube cryocooler capable of roughly 50 W of lift at 100 K. Instrumentation includes ten temperature sensors mounted on a vertical rake and five liquid sample tubes corresponding to five liquid levels. Two modes of operation are studied. The first is without refrigeration in order to determine a baseline in the change in composition, and to study stratification of the LNG. The second is performed with the cryocooler active to determine the operational parameters of the IRaS system for eliminating the weathering as well as stratification effects in the bulk liquid. The apparatus design and test method, as well as preliminary test results are presented in this paper. As a bonus in cost-saving and operational efficiency, the capability of the IRaS system to provide zero-loss capabilities such as zero boil-off (ZBO) keeping of the LNG and zero-loss filling/transfer operations are also discussed.

Rose, L.↗

Integrated Refrigeration and Storage for Advanced Liquid Hydrogen Operations

NASA has used liquefied hydrogen (LH2) on a large scale since the beginning of the space program as fuel for the Centaur and Apollo upper stages, and more recently to feed the three space shuttle main engines. The LH2 systems currently in place at the Kennedy Space Center (KSC) launch pads are aging and inefficient compared to the state-of-the-art. Therefore, the need exists to explore advanced technologies and operations that can drive commodity costs down, and provide increased capabilities. The Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) was developed at KSC to pursue these goals by demonstrating active thermal control of the propellant state by direct removal of heat using a cryocooler. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The key technology challenge was efficiently integrating the cryogenic refrigerator into the LH2 storage tank. A Linde LR1620 Brayton cycle refrigerator is used to produce up to 900W cooling at 20K, circulating approximately 22 g/s gaseous helium through the hydrogen via approximately 300 m of heat exchanger tubing. The GODU-LH2 system is fully operational, and is currently under test. This paper will discuss the design features of the refrigerator and storage system, as well as the current test results.

Liquefaction↗

Study of Thermodynamic Vent and Screen Baffle Integration for Orbital Storage and Transfer of Liquid Hydrogen

A comprehensive analytical and experimental program was performed to determine the feasibility of integrating an internal thermodynamic vent system and a full wall-screen liner for the orbital storage and transfer of liquid hydrogen (LH2). Ten screens were selected from a comprehensive screen survey. The experimental study determined the screen bubble point, flow-through pressure loss, and pressure loss along rectangular channels lined with screen on one side, for the 10 screens using LH2 saturated at 34.5 N/cm2 (50 psia). The correlated experimental data were used in an analysis to determine the optimum system characteristics in terms of minimum weight for 6 tanks ranging from 141.6 m3 (5,000 ft3) to 1.416 m3 (50 ft3) for orbital storage times of 30 and 300 days.

Cady, E. C.↗

Optical storage media data integrity studies

Optical disk-based information systems are being used in private industry and many Federal Government agencies for on-line and long-term storage of large quantities of data. The storage devices that are part of these systems are designed with powerful, but not unlimited, media error correction capacities. The integrity of data stored on optical disks does not only depend on the life expectancy specifications for the medium. Different factors, including handling and storage conditions, may result in an increase of medium errors in size and frequency. Monitoring the potential data degradation is crucial, especially for long term applications. Efforts are being made by the Association for Information and Image Management Technical Committee C21, Storage Devices and Applications, to specify methods for monitoring and reporting to the user medium errors detected by the storage device while writing, reading or verifying the data stored in that medium. The Computer Systems Laboratory (CSL) of the National Institute of Standard and Technology (NIST) has a leadership role in the development of these standard techniques. In addition, CSL is researching other data integrity issues, including the investigation of error-resilient compression algorithms. NIST has conducted care and handling experiments on optical disk media with the objective of identifying possible causes of degradation. NIST work in data integrity and related standards activities is described.

Podio, Fernando L.↗

Provision of Grid Services by PV Plants with Integrated Battery Energy Storage System: Preprint

Battery energy storage systems (BESS), due to their tremendous range of uses and configurations, may assist PV integration in any number of ways by increasing power system flexibility. In this paper we describe results of a research project conducted by NREL and First Solar for developing controls and demonstrating many use cases for PV-BESS systems including (1) matching generation to loads through time shifting, reducing PV curtailment,; (2) promoting higher levels of PV penetrations by balancing the grid through ancillary services; (3) use of PV-BESS systems to provide wide-area stability services in the form of oscillations damping controls; and (r) use of gird forming BESS for enabling black start and islanded applications for PV-BESS systems. In the paper we will also describe the unique multi-MW test and validation platform developed at NREL for conducting research on fielded utility-scale PV-BESS systems. The platform consists of First Solar 0.43 MW PV power plant, NREL’s 1MW/1MW BESS, 2MW PV power supplies and 7MVA power electronic grid simulator interfaced with industrial plant controllers and power-hardware-in-the-loop (PHIL) capability.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Integral Radiator and Storage Tank

A simplified, lightweight system for dissipating heat of a regenerative fuel- cell system would include a heat pipe with its evaporator end placed at the heat source and its condenser end integrated into the wall of the regenerative fuel cell system gas-storage tanks. The tank walls act as heat-radiating surfaces for cooling the regenerative fuel cell system. The system was conceived for use in outer space, where radiation is the only physical mechanism available for transferring heat to the environment. The system could also be adapted for use on propellant tanks or other large-surface-area structures to convert them to space heat-radiating structures. Typically for a regenerative fuel cell system, the radiator is separate from the gas-storage tanks. By using each tank s surface as a heat-radiating surface, the need for a separate, potentially massive radiator structure is eliminated. In addition to the mass savings, overall volume is reduced because a more compact packaging scheme is possible. The underlying tank wall structure provides ample support for heat pipes that help to distribute the heat over the entire tank surface. The heat pipes are attached to the outer surface of each gas-storage tank by use of a high-thermal conductance, carbon-fiber composite-material wrap. Through proper choice of the composite layup, it is possible to exploit the high longitudinal conductivity of the carbon fibers (greater than the thermal conductivity of copper) to minimize the unevenness of the temperature distribution over the tank surface, thereby helping to maximize the overall heat-transfer efficiency. In a prototype of the system, the heat pipe and the composite wrap contribute an average mass of 340 g/sq m of radiator area. Lightweight space radiator panels have a mass of about 3,000 g/sq m of radiator area, so this technique saves almost 90 percent of the mass of separate radiator panels. In tests, the modified surface of the tank was found to have an emissivity of 0.85. The composite wrap remained tightly bound to the surface of the tank throughout the testing in thermal vacuum conditions.

Burke, Kenneth A.↗

De-risking fault leakage risk and containment integrity for subsurface storage applications

The subsurface is pivotal in the energy transition, for the sequestration of CO 2 and energy storage. It is crucial to understand to what extent geological faults may form leakage pathways that threaten the containment integrity of these projects. Fault flow behavior has been studied in the context of hydrocarbon development, supported by observations from wells drilled through faults, but such observations are rare in geoenergy projects. Focusing on mechanical behavior as early indicator of potential leakage risks, a probabilistic Coulomb Failure Stress workflow is developed and demonstrated using data from the Decatur CO 2 sequestration project to rank faults based on their containment risk. The analysis emphasizes the importance of fault throw relative to reservoir thickness and pore pressure change in assessing reactivation risks. Integrating this mechanical assessment with geological and dynamic fault analyses contributes to derisking fault containment for geoenergy applications, providing valuable insights for the successful development of subsurface storage projects.

58 GEOSCIENCES↗

Framework development for a SAVY-4000 nuclear material storage container structural integrity surveillance tool

Here, this work presents the preliminary design of an automated surveillance tool to assess the health of SAVY-4000 nuclear material storage containers. This tool is designed by training several machine learning (ML) regression models to predict maximum residual stress in plain dents on the container sidewall. The model is trained on an experimentally validated Finite Element Analysis (FEA) model built in Abaqus FEA. The accuracy of each ML model is compared. The potential for application as well as model shortcomings are assessed. Necessary FEA model improvements are outlined and the various ML models are proposed.

36 MATERIALS SCIENCE↗

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

Grand challenges in mass storage: A systems integrators perspective

Within today's much ballyhooed supercomputing environment, with its CFLOPS of CPU power, and Gigabit networks, there exists a major roadblock to computing success; that of Mass Storage. The solution to this mass storage problem is considered to be one of the 'Grand Challenges' facing the computer industry today, as well as long into the future. It has become obvious to us, as well as many others in the industry, that there is no clear single solution in sight. The Systems Integrator today is faced with a myriad of quandaries in approaching this challenge. He must first be innovative in approach, second choose hardware solutions that are volumetric efficient; high in signal bandwidth; available from multiple sources; competitively priced, and have forward growth extendibility. In addition he must also comply with a variety of mandated, and often conflicting software standards (GOSIP, POSIX, IEEE, MSRM 4.0, and others), and finally he must deliver a systems solution with the 'most bang for the buck' in terms of cost vs. performance factors. These quandaries challenge the Systems Integrator to 'push the envelope' in terms of his or her ingenuity and innovation on an almost daily basis. This dynamic is explored further, and an attempt to acquaint the audience with rational approaches to this 'Grand Challenge' is made.

Lee, Richard R.↗

Carbon Mitigation Potential of Heat Pump Integrated with Thermal Storage for Grid-Interactive Residential Buildings

Residential buildings’ heating and cooling loads are associated with significant carbon emissions and peak electricity demand. Phase change material (PCM) based thermal energy storage (TES) can be used for space heating and cooling by embedding into the heat pump equipment. Past work on TES integrated with heat pumps (HP) has demonstrated significant load shifting and economic benefits. However, the potential for TES to reduce carbon emissions has not been widely explored. This study evaluates carbon mitigation potential of an ice-based TES coupled to HP (HP-TES) based on a simple rule-based control strategy accounting for electric grid emissions data. A vapor compression HP model using Engineering Equation Solver (EES). The modeled HP-TES system for single-family residential building demonstrates decreased carbon emissions with reduced peak utility cost.

Sultan, Sara↗

Integrated heat pipe-thermal storage system performance evaluation

An integrated thermal energy storage (TES) system, developed as a part of an organic Rankine cycle solar dynamic power system is described, and the results of the performance verification tests of this TES system are presented. The integrated system consists of potassium heat-pipe elements that incorporate TES canisters within the vapor space, along with an organic fluid heater tube used as the condenser region of the heat pipe. The heat pipe assembly was operated through the range of design conditions from the nominal design input of 4.8 kW to a maximum of 5.7 kW. The performance verification tests show that the system meets the functional requirements of absorbing the solar energy reflected by the concentrator, transporting the energy to the organic Rankine heater, providing thermal storage for the eclipse phase, and allowing uniform discharge from the thermal storage to the heater.

Keddy, E.↗

Sensitivity Analysis of Salt Storage Cavern Mechanical Integrity Test Parameters

This report examines the sensitivity of salt cavern Mechanical Integrity Tests (MIT) to uncertainties in key test parameters. MIT's are used by cavern operators to detect and quantify leak rates in access wells in underground salt storage caverns and involve a suite of measured and assumed parameters that have a direct impact on the sensitivity of the testing to detect actual leaks from the cavern storage system. Determining the sensitivity of the testing to these different parameters provides a basis for understanding the results from, and informing the design criteria for, this type of testing. Without fully understanding the sensitivity of the test to the testing parameters, it is possible that the test results may not accurately reflect the integrity of the cavern system; an actual leak may be missed, or an intact system may be interpreted as leaking. This report reviews the main parameters included in MITs and examines how selected changes in their values can impact test results. The deviations used in the sensitivity analyses were designed to be within the ranges believed to be similar to those which may be encountered during testing. The results show that small, plausible fluctuations in some of the parameters measured values can have a significant impact on the testing results. Of the parameters studied here, the sensitivity analyses showed the order of importance to be (from highest to lowest): nitrogen-oil interface depth measurement, well bore temperature, well head pressure, and finally the internal geometry of the testing interval.

42 ENGINEERING↗

A proposed methodology to reduce heat pump size with integrated thermal energy storage

Thermal energy storage (TES) offers a unique storage solution wherein heat is stored for later use to thermally condition an application. Heat pumps (HPs) move heat from relatively cold to a relatively hot with an input of work. Integrating TES into a HP system adds a third temperature body, and the HP can be selectively coupled to operate between any two: a constant temperature application, a temporally fluctuating ambient temperature, or a constant temperature TES. Since the HP-TES system enables operation under different conditions depending on the pair of temperature bodies, changes in efficiency and capacity can be expected. Thus, TES can shift HP operation to more favorable conditions to deliver heat to the application. Consequently, TES increases the apparent capacity of the HP which might enable a nominally smaller HP to be used effectively. This paper outlines a method by which TES can reduce the size of a HP without sacrificing heat delivered to the application. The method is demonstrated for a building cooling application which realized a reduction in nominal HP size from 3 tons to 2.4 tons.

Hirschey, Jason↗

Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as an Innovative Energy Storage Technology for Fossil-Integrated Systems

Pumped-storage hydropower (PSH) provides around 95% of all utility-scale energy storage in the U.S. and globally. Additional deployment of PSH is hampered by excessively long permitting and commissioning requirements and is constrained to locations for which natural topography provides suitable elevation relief between the upper and lower reservoirs (the ΔH challenge). The purpose of this research was to evaluate Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as a means to solve the ΔH challenge and initiate the commercialization pathway for a promising new energy storage technology. Four primary tasks were conducted: Screening and ranking of candidate sites for project development; multiphase reservoir modeling to evaluate mine performance; techno-economic analysis and preliminary designs for PSH-AUM systems integrated with fossil-fuel power units; and stakeholder engagement to identify pathways to commercialization of this new technology. Key results were achieved in each of the four primary tasks. Candidate site screening determined that nearly 10,000 underground mines were spatially locatable, of which more than 100 sites appear suitable for integration with existing fossil power plants that are expected to remain in longer-term operation. Mine reservoir models were developed using PNNL’s STOMP simulator and parameterized using candidate site data to evaluate interactions with the surrounding groundwater system and confirm the potential for some mines to accommodate inflows and outflows on the order of 100 m3/s over 8-hour durations (1.6 GWh system) without excessive aqueous pressures. Techno-economic analysis resulted in a project cost optimization scheme to identify key sensitivities and the development of preliminary designs that can minimize overall costs of deployment. Finally, stakeholder engagement with industry, state government, and local economic development leaders confirmed the viability of PSH-AUM as a promising new technology. Our Phase I project results suggest that PSH-AUM technology has a domestic market potential on the order of $100+ Billion with ample space for technology development to commercialization within the next decade.

13 HYDRO ENERGY↗