Search NASA⌕ Search

SEARCH · Search NASA

Results for “invasion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Non-Invasive Approach for Elucidating the Spatial Distribution of in-situ Stress in Deep Subsurface Geologic Formations Considered for CO 2 Storage (Task 4 (Field Testing) Report)

"This document presents a summary of TASK 4 (Field Testing) of the project entitled “A Non-Invasive Approach for Elucidating the Spatial Distribution of in-situ Stress in Deep Subsurface Geologic Formations Considered for CO 2 Storage (FE0031686)”. This three-year project is part of the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Carbon Storage program to research and address gaps that affect the economics of commercial CCS projects. One of these key gaps is the lack of certainty in predicting the geomechanical impacts of pressure migration due to CO 2 injection into a storage complex. This report documents field testing that was conducted under TASK 4 to obtain input data needed to develop the site-specific geomechanical model in TASK 5 and to verify the model results (i.e. calculated stresses) for this site. The field work entailed collecting geophysical logs and core samples and conducting geomechanical stress tests in the Core Energy LLC State Otsego Lake (SOL 8-15A) well, located in Otsego County, Michigan."

58 GEOSCIENCES↗

Demonstration and Evaluation of a Non-Invasive, Low-Cost, Strap-On Sensor for Natural Gas Meters

The U.S. General Services Administration (GSA) is interested in installing internet-connected, gas submeters to better understand gas consumption in its portfolio of buildings. The GSA in partnership with the National Renewable Energy Laboratory conducted a demonstration to assess a specific submeter technology. This technology was implemented at two GSA separate facilities located in Dallas, Texas. This demonstration evaluated hardware and software installations and integrations, data integrity and accuracy, and included an economic analysis. This demonstration evaluated a gas submeter technology provided by the vendor Vata Verks, who produces a non-invasive strap-on submeter. The company was founded with a mission to conserve water (and eventually gas) cheaply and simply, as explained on its website. The product intends to streamline submeter deployments for gas and water by eliminating most hardware costs while allowing for easy integration of submetered data into other systems such as the Building Automation System and removing tenant and building disruption This demonstration evaluated the product features when used on a gas utility meter.

03 NATURAL GAS↗

The Russian Invasion of Ukraine and Nuclear Security

You have in your hands a unique publication. Voices of Ukraine is a collection of testimonies from people working in the nuclear and radioactive source sector in Ukraine. The five texts in this extract are a preview of the full volume that will be published in early 2023. The accounts presented in this extract are very different from the newspaper articles or reports you may have read about the Russian invasion of Ukraine and the attack on and occupation of the Chornobyl Exclusion Zone and Zaporizhzhia NPP. Five people share their own stories of the personal and professional dilemmas they faced: How to endure an unending shift under enemy occupation when replacement workers weren’t permitted to relieve the staff; whether to remain in your childhood home or to flee abroad; how to support your community and country while maintaining the safe operation of nuclear sites in wartime conditions? The narratives of these individuals have far-reaching consequences for the nuclear sector in Ukraine but also far beyond it.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Post-Invasion Damage Assessment: Ukraine’s Crop Storage Infrastructure

The Yale School of Public Health's (YSPH) Humanitarian Research Lab (HRL), working in collaboration with Oak Ridge National Labs (ORNL), concludes with high confidence that approximately 21.5% of Ukraine’s estimated 57 million tonnes of crop storage capacity has been impacted by conflict since Russia’s full-scale invasion of Ukraine in February 2022. Intentional and indiscriminate targeting of crop storage infrastructure can constitute a war crime and a crime against humanity under international law.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electrochemical aptamer-based sensors: leveraging the sensing platform for minimally-invasive microneedle measurements and fundamental exploration of sensor biofouling dynamics

The ability to track the concentrations of specific molecules in the body in real time would significantly improve our ability to study, monitor, and respond to diseases. To achieve this, we require sensors that can withstand the complex environment inside the body. Electrochemical aptamer-based sensors are particularly promising for in vivo sensing, as they are among the only generalizable sensing technologies that can achieve real-time molecular monitoring directly in blood and the living body. In this project, we first focused on extending the application space of aptamer sensors to support minimally-invasive wearable measurements. To achieve this, we developed individually-addressable sensors with commercial off-the-shelf microneedles. We demonstrated sensor function in buffer, blood, and porcine skin (a common proxy for human skin). In addition to the applied sensing project, we also worked to improve fundamental understanding of the aptamer sensing platform and how it responds to biomolecular interferents. Specifically, we explored the interfacial dynamics of biofouling – a process impacting sensors placed in complex fluids, such as blood.

59 BASIC BIOLOGICAL SCIENCES↗

Scale up, Field Testing, and Optimization of Nontoxic, Durable, Economical Coatings for Control of Invasive mussels at Hydropower Facilities (Final Report for CRADA 527)

In this effort, Pacific Northwest National Laboratory (PNNL) demonstrated the technical maturation of a durable, economical, and nontoxic coating (Superhydrophobic Lubricant Infused Composite, SLIC) that prevents invasive mussels and other unwanted organisms from growing on hydropower and marine structures. The physical characteristics of SLIC were measured using a variety of industry standard methods, just as a commercially available paint would, to show that it can rival other antifouling paints on the market not just in antifouling efficacy, but in structural integrity. SLIC also underwent extensive field testing in diverse field sites across the US to demonstrate that it is effective in varying environments. Engagement with industrial partners showed there is continued interest and need for a cost-effective, durable antifouling coating such as SLIC.

13 HYDRO ENERGY↗

Non-invasive Pipe Pressure Monitoring for Safeguards

Our project explores a new solution to complement current safeguards toolbox by independently, and noninvasively, determining the pressure inside uranium hexafluoride (UF 6 )-carrying Gas Centrifuge Enrichment Plant (GCEP) pipes. Proof-of-principle, non-invasive pipe pressure monitoring tests were conducted through measurements of hoop and axial strain using an optical-interference dilatometry technique based on fiber Bragg gratings (FBGs) inscribed in the core of telecommunication-type 125 µm diameter optical fibers. The fibers were affixed to commercial stainless steel and aluminum tubes and pipes of the type expected to be found at GCEP’s, each measuring four inches in diameter. When the internal air pressure in the pipes changes their external diameter and length follow, and the pitch in the FBG shrinks and/or expands accordingly. In turn, these changes result in a shift of the light wavelength reflected by the FBGs. Several FBGs physically attached to the pipe, as well as control FBGs not attached, were interrogated during the process using state-of-the-art commercial interrogators that operate on swept-wavelength laser technology. Strains measured were contrasted against calculations based on the known elastic and mechanical properties of the pipes. Good agreement is found, and strategies are proposed for further improvement of the experimental resolution as well as future implementation of this novel approach for GCEP safeguards.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a Non-Invasive Laser-based Beam Profile Monitor System for the New Fermilab PIP-II Superconducting H- Linac

As part of the new Proton Improvement Plan (PIP-II), Fermilab is undertaking the development of a new 800 MeV, 2 mA H- superconducting RF linac to replace its present normal conducting 400 MeV linac. The PIP-II linac consists of a series of superconducting RF cryomodules from 2.1 MeV to 800 MeV. To limit the potential damage to the superconducting RF cavities, PIP-II will utilize non-invasive laser-based monitors (laserwires) to obtain beam profiles via photoionization. This paper will present the design of this PIP-II laserwire system including the picosecond pulsed laser, optical transport line, 13 individual laserwire stations, laser feedback and timing controls.

Scarpine, V. [Fermilab]↗

Prognostic analysis of high-flow nasal cannula therapy and non-invasive ventilation in mild to moderate hypoxemia patients and construction of a machine learning model for 48-h intubation prediction—a retrospective analysis of the MIMIC database

Background This study aims to investigate the clinical outcome between high-flow nasal cannula (HFNC) and non-invasive ventilation (NIV) therapy in mild to moderate hypoxemic patients on the first ICU day and to develop a predictive model of 48-h intubation. Methods The study included adult patients from the MIMIC III and IV databases who first initiated HFNC or NIV therapy due to mild to moderate hypoxemia (100 < PaO2/FiO2 ≤ 300). The 48-h and 30-day intubation rates were compared using cross-sectional and survival analysis. Nine machine learning and six ensemble algorithms were deployed to construct the 48-h intubation predictive models, of which the optimal model was determined by its prediction accuracy. The top 10 risk and protective factors were identified using the Shapley interpretation algorithm. Result A total of 123,042 patients were screened, of which, 673 were from the MIMIC IV database for ventilation therapy comparison (HFNC n = 363, NIV n = 310) and 48-h intubation predictive model construction (training dataset n = 471, internal validation set n = 202) and 408 were from the MIMIC III database for external validation. The NIV group had a lower intubation rate (23.1% vs. 16.1%, p = 0.001), ICU 28-day mortality (18.5% vs. 11.6%, p = 0.014), and in-hospital mortality (19.6% vs. 11.9%, p = 0.007) compared to the HFNC group. Survival analysis showed that the total and 48-h intubation rates were not significantly different. The ensemble AdaBoost decision tree model (internal and external validation set AUROC 0.878, 0.726) had the best predictive accuracy performance. The model Shapley algorithm showed Sequential Organ Failure Assessment (SOFA), acute physiology scores (APSIII), the minimum and maximum lactate value as risk factors for early failure and age, the maximum PaCO 2 and PH value, Glasgow Coma Scale (GCS), the minimum PaO 2 /FiO 2 ratio, and PaO 2 value as protective factors. Conclusion NIV was associated with lower intubation rate and ICU 28-day and in-hospital mortality. Further survival analysis reinforced that the effect of NIV on the intubation rate might partly be attributed to the other impact factors. The ensemble AdaBoost decision tree model may assist clinicians in making clinical decisions, and early organ function support to improve patients’ SOFA, APSIII, GCS, PaCO 2 , PaO 2 , PH, PaO 2 /FiO 2 ratio, and lactate values can reduce the early failure rate and improve patient prognosis.

Fu, Wei↗

Chemistry in Retrieved Ryugu Asteroid Samples Revealed by Non-Invasive X-ray Microanalyses: Pink-Beam Fluorescence CT and Tender-Energy Absorption Spectroscopy

The Hayabusa2 space mission recently retrieved 5.4 g of material from asteroid Ryugu, providing the first direct access to pristine material from a carbonaceous asteroid. This study employs a novel combination of non-invasive synchrotron X-ray techniques to examine microscale chemistry (elemental distributions and element-specific chemical speciation and local structure) inside Ryugu grains without physically cutting the samples. Manganese primarily occurs in carbonate: Mn-bearing dolomite with minor earlier ankerite. Iron sulfides present as large single grains and as smaller particles in the finer-grained matrix are both predominantly pyrrhotite. At the 5 μm scale, Fe sulfides do not show the mineralogical heterogeneity seen in many carbonaceous meteorites but exhibit some heterogeneous localized oxidation. Iron is present often as intergrowths of oxide and sulfide, indicating incomplete replacement. Trace selenium substitutes for S in pyrrhotite. Copper is present as Fe-poor Cu sulfide. These results demonstrate multiple episodes of fluid alteration on the parent body, including partial oxidation, and help constrain the sequence or evolution of fluids and processes that resulted in the current grain-scale mineralogical composition of Ryugu materials.

36 MATERIALS SCIENCE↗

Non-invasive mid-circuit measurement and reset on atomic qubits

Mid-circuit measurement and reset of subsets of qubits is a crucial ingredient of quantum error correction and many quantum information applications. Measurement of atomic qubits is accomplished through resonant fluorescence, which typically disturbs neighboring atoms due to photon scattering. We propose and prototype a new scheme for measurement that provides both spatial and spectral isolation by using tightly-focused individual laser beams and narrow atomic transitions. The unique advantage of this scheme is that all operations are applied exclusively to the read-out qubit, with negligible disturbance to the other qubits of the same species and little overhead. In this letter, we pave the way for non-invasive and high fidelity mid-circuit measurement and demonstrate all key building blocks on a single trapped barium ion.

Atomic Physics (physics.atom-ph)↗

Non-invasive method and apparatus for measuring pressure within a pliable vessel

A non-invasive method and apparatus is disclosed for measuring pressure within a pliable vessel such as a blood vessel. The blood vessel is clamped by means of a clamping structure having a first portion housing a pressure sensor and a second portion extending over the remote side of the blood vessel for pressing the blood vessel into engagement with the pressure sensing device. The pressure sensing device includes a flat deflectable diaphragm portion arranged to engage a portion of the blood vessel flattened against the diaphragm by means of the clamp structure. In one embodiment, the clamp structure includes first and second semicylindrical members held together by retaining rings. In a second embodiment the clamp structure is of one piece construction having a solid semicylindrical portion and a hollow semicylindrical portion with a longitudinal slot in the follow semicylindrical portion through which a slip the blood vessel. In a third embodiment, an elastic strap is employed for clamping the blood vessel against the pressure sensing device.

Shimizu, M.↗

Method and apparatus for non-invasive evaluation of diaphragmatic function

A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.

Yost, William T.↗

Method and apparatus for non-invasive evaluation of diaphragmatic function

A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.

Yost, William T.↗

Development and Applications of a Self-Contained, Non-Invasive EVA Joint Angle and Muscle Fatigue Sensor System

The University of Maryland Space Systems Laboratory, as a participant in NASA's INSTEP program, is developing a non-invasive, self-contained sensor system which can provide quantitative measurements of joint angles and muscle fatigue in the hand and forearm. The goal of this project is to develop a system with which hand/forearm motion and fatigue metrics can be determined in various terrestrial and zero-G work environments. A preliminary study of the prototype sensor systems and data reduction techniques for the fatigue measurement system are presented. The sensor systems evaluated include fiberoptics, used to measure joint angle, surface electrodes, which measure the electrical signals created in muscle as it contracts; microphones, which measure the noise made by contracting muscle; and accelerometers, which measure the lateral muscle acceleration during contraction. The prototype sensor systems were used to monitor joint motion of the metacarpophalangeal joint and muscle fatigue in flexor digitorum superficialis and flexor carpi ulnaris in subjects performing gripping tasks. Subjects were asked to sustain a 60-second constant-contraction (isometric) exercise and subsequently to perform a repetitive handgripping task to failure. Comparison of the electrical and mechanical signals of the muscles during the different tasks will be used to evaluate the applicability of muscle signal measurement techniques developed for isometric contraction tasks to fatigue prediction in quasi-dynamic exercises. Potential data reduction schemes are presented.

Ranniger, C. U.↗

Microinvertebrates in CELSS Hydroponic Rhizosphere: Experimental Invasion as a Test of Community Stability and a Test of a Method to Measure Bacterivory

This report consists of two separate draft manuscripts, each prepared for submittal to a peer-reviewed journal after Kennedy Space Center (KSC) colleague editorial review and final revision. References for the two papers have been combined in this report. The two manuscripts are: (1) Experimental invasion of aquatic rhizosphere habitat and invertebrate communities, and (2) Lysozyme analysis is neither protistan- or bacteriore-specific.

Sager, John↗

Development of Minimally-Invasive Aortic Pressure and Flow Instrumentation

To better understand the mechanisms underlying the effects of microgravity on the cardiovascular system, cardiovascular models have been developed. These computational models estimate changes in cardiovascular parameters such as total peripheral resistance and systemic arterial compliance, and require high quality aortic pressure and flow measurements as their input. Many of these measurements are obtained in experimental animals and therefore the invasiveness of the instrumentation must be as kept to a minimum. These considerations are the primary motivation behind this work.

Ewert, Dan↗