Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Thermal control of a lidar laser system using a non-conventional ram air heat exchanger

This paper describes the analysis and performance testing of a uniquely designed external heat exchanger. The heat exchanger is attached externally to an aircraft and is used to cool a laser system within the fuselage. Estimates showed insufficient cooling capacity with a conventional staggered tube array in the limited space available. Thus, a non-conventional design wes developed with larger tube and fin area exposed to the ram air to increase the heat transfer performance. The basic design consists of 28 circular finned aluminum tubes arranged in two parallel banks. Wind tunnel tests were performed to simulate air and liquid flight conditions for the non-conventional parallel bank arrangement and the conventional staggered tube arrangement. Performance comparisons of each of the two designs are presented. Test results are used in a computer model of the heat exchanger to predict the operating performance for the entire flight profile. These analyses predict significantly improved performance over the conventional design and show adequate thermal control margins.

Killough, Brian D.↗

Investigations of a circulation control airfoil flowfield using an advanced laser velocimeter

The flowfield of a Circulation Control Airfoil was examined in detail through the use of a specially designed wind tunnel model and test program. Surface pressures on the model were obtained and the velocity field was surveyed in the trailing edge region of the model airfoil using the nonintrusive Laser Velocimetry technique. In this region mean flow and turbulence measurements indicate that, while the flowfield is similar to other wall-bounded jet flows, the external freestream plays an important role in the overall mixing and structure of the wall bounded flow. Finally, the turbulence measurements were used to compute eddy viscosities for the purpose of aiding computational fluid dynamics model development.

Novak, Charles J.↗

Laser velocimeter stand-alone controller

A distributed microprocessor network has been developed to position a laser-based velocity measurement package. Designed primarily for use inside the Ames 40 x 80-foot Subsonic Wind Tunnel, the instrument assembly is remotely operated. The mechanical system is reconfigurable for other test environments which necessitates an adaptive control approach. Three stepper motor drives provide two-dimensional positioning of the sampling point over 200/sq m of the test section, with a 5-mm resolution. Real-time multiprocessing provides fast response, fault detection, and parametric data acquisition. Manual tests are run from a dedicated control panel and automated tests are accomplished via an I.E.E.E 488 interface. The design approach and the progress to date are discussed.

Brown, R.↗

Digital laser-beam deflection sensor

Sensor automatically and accurately measures the two-dimensional deflection angles of a laser beam to provide closed-loop servomechanism control of laser beam directivity.

Fowler, V. J.↗

Longitudinal-mode control in integrated semiconductor laser phased arrays by phase velocity matching

The spectrum of semiconductor-laser arrays with separate contacts is investigated. It is demonstrated that the individual laser currents can be selected such that the array operates in a single longitudinal mode, in contrast to the multimode nature of its individual constituents. Moreover, it is possible to tune the lasing frequency by varying the laser currents. Wavelength tuning range of about 50 A, with tuning rate of about 5 A per milliampere, is demonstrated. It is suggested that these spectral features, characteristic of lasers which are coupled in parallel, result from the strong frequency dependence of their spatial mode pattern near the phase-matching frequency of their coupled waveguides.

Kapon, E.↗

Single mode wavelength control of modulated AlGaAs lasers with external and internal etalon feedback

Single mode lasing without mode hops has been obtained for VSIS and CSP laser diodes with an external etalon attached to the laser's front facet for up to an 8 C range CW and a 4 C range pulsed, with .07 nm/C tuning. Tests of thin tapered-thickness (TTT) laser diodes show CW and pulsed single mode lasing over 10 C and 2 C ranges, respectively, with .08 nm/C tuning. An analysis of the TTT structure reveals the equivalent of an internal etalon. The time-resolved pulsed behavior for both types of lasers show single mode lasing within the proper temperature ranges with minor modes present only early in the optical pulse, if at all. The external etalon produces noticeable interference fringes in the farfield pattern, while those of the TTT lasers are smooth. Ongoing CW lifetest results indicate stability to within one longitudinal mode after a few hundred hours of operation, along with at least several thousand hours lifetime.

Maynard, William L.↗

The Palomar Testbed Interferometer

The Palomar Testbed Interferometer (PTI) is a long-baseline infrared interferometer located at Palomar Observatory, California. It was built as a testbed for interferometric techniques applicable to the Keck Interferometer. First fringes were obtained in 1995 July. PTI implements a dual-star architecture, tracking two stars simultaneously for phase referencing and narrow-angle astrometry. The three fixed 40 cm apertures can be combined pairwise to provide baselines to 110 m. The interferometer actively tracks the white-light fringe using an array detector at 2.2 microns and active delay lines with a range of +/-38 m. Laser metrology of the delay lines allows for servo control, and laser metrology of the complete optical path enables narrow-angle astrometric measurements. The instrument is highly automated, using a multiprocessing computer system for instrument control and sequencing.

Colavita, M. M.↗

Computer processing of tunable diode laser spectra

A computer-controlled tunable diode laser spectrometer and spectral analysis software are described. The three-channel system records simultaneously the transmission of a subject gas, a temperature-stabilized etalon, and a calibration gas. The software routines are applied to diode laser spectra of HNO3 and NO2 to illustrate the procedures adopted for conversion of raw spectral data to useful transmission and harmonic spectra. Extraction of line positions, absorption intensities, collisional broadening coefficients, and gas concentrations from recorded spectra is also described.

May, Randy D.↗

A Method for Determining the Nominal Occular Hazard Zone for Gaussian Beam Laser Rangers with a Firmware Controlled Variable Focal Length

LIDAR systems that maintain a constant beam spot size on a retroreflector in order to increase the accuracy of bearing and ranging data must use a software controlled variable position lens. These systems periodically update the estimated range and set the position of the focusing lens accordingly. In order to precisely calculate the r NOHD for such a system, the software method for setting the variable position lens and gaussian laser propagation can be used to calculate the irradiance at any point given the range estimation. NASA s Space Shuttle LIDAR, called the Trajectory Control Sensor (TCS), uses this configuration. Analytical tools were developed using Excel and VBA to determine the radiant energy to the International Space Station (ISS) crewmembers eyes while viewing the shuttle on approach and departure. Various viewing scenarios are considered including the use of through-the-lens imaging optics and the window transmissivity at the TCS wavelength. The methodology incorporates the TCS system control logic, gaussian laser propagation, potential failure mode end states, and guidance from American National Standard for the Safe Use of Lasers (ANSI Z136.1-2007). This approach can be adapted for laser safety analyses of similar LIDAR systems.

Picco, C. E.↗

Laser Mode Behavior of the Cassini CIRS Fourier Transform Spectrometer at Saturn

The CIRS Fourier transform spectrometer aboard the NASA/ESA/ASI Cassini orbiter has been acquiring spectra of the Saturnian system since 2004. The CIRS reference interferometer employs a laser diode to trigger the interferogram sampling. Although the control of laser diode drive current and operating temperature are stringent enough to restrict laser wavelength variation to a small fraction of CIRS finest resolution element, the CIRS instrument does need to be restarted every year or two, at which time it may start in a new laser mode. By monitoring the Mylar absorption features in uncalibrated spectra due to the beam splitter Mylar substrate, it can be shown that these jumps are to adjacent modes and that most of the eight-year operation so far is restricted to three adjacent modes. For a given mode, the wavelength stability appears consistent with the stability of the laser diode drive curren.t and operating temperature.

Brasunas, John C.↗

Azimuthal Variation of Instabilities Generated on a Flared Cone by Laser Perturbations

To study the azimuthal development of boundary-layer instabilities, a controlled, laser-generated perturbation was created in the freestream of the Boeing/U.S. Air Force Office of Scientific Research Mach 6 Quiet Tunnel. The freestream perturbation convected downstream in the wind tunnel to interact with a flared-cone model. The flared cone is a body of revolution bounded by a circular arc with a 3 m radius. Pressure transducers were used to measure a wave packet generated in the cone boundary layer by the freestream perturbation. Nine of these sensors formed three stations of azimuthal arrays and were used to determine the azimuthal variation of the wave packets in the boundary layer. The freestream laser-generated perturbation was positioned upstream of the model in three different configurations: along the centerline axis, offset from the centerline axis by 1.5 mm, and offset from the centerline axis by 3.0 mm. When the freestream perturbation was offset from the centerline of a flared cone with a 1.0 mm nose radius, a larger wave packet was generated on the side toward which the perturbation was offset. As a result, transition occurred earlier on that side. The offset perturbation did not have as large of an effect on the boundary layer of a nominally sharp flared cone.

Chou, Amanda↗

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Spectral performance of monolithic holmium and thulium lasers

Fabry-Perot resonators have been used to demonstrate single-mode lasing of holmium and neodymium YAG. The previous demonstration in the holmium laser required TE cooling the crystal to -15 C in order to achieve threshold. The present study extends that result, demonstrating +25 C operation in a 1-mm thick plano/plano resonator. The experimental configuration of lasing both the holmium and thulium lasers used a 500-mW diode laser which was collimated, circularized, and focused into a beam radius of 60 microns. The single-frequency lasing spectrum of the holmium laser is shown. By adjusting the mirror reflectivity, the ability to control the laser's wavelength is demonstrated. This laser operated with 11 mW of optical power, a 57-percent slope efficiency, and 120-mW threshold vs absorbed diode power laser for the 60-micron beam radius. The thulium laser operated very efficiently at room temperature, but on seven longitudinal modes. The Tm:TAG laser exhibits typical characteristics of spatial hole burning not seen in the Ho:Tm:YAG for flat/flat resonators.

Storm, Mark E.↗

Quasi-perfect FIFO: Synchronous or asynchronous with application in controller design for the UNICON laser memory

The first-in-first-out memory buffer (FIFO), is an elastic digital memory whose main application is in data buffering between devices operating at different rates. Data written into the top is moved autonomously down toward the bottom of the FIFO to the lowest unoccupied location, and data read from the bottom of the FIFO will cause data from the top to move autonomously down toward the bottom. The FIFO is available in MOS LSI asynchronous form with data rate in the 1 MHz region. The FIFO described yields a simple high-speed iterative implementation, either synchronous of asynchronous. Because of this simple iterative structure, the FIFO is expandable in both number of words and bits per word, and it is attractive from the viewpoint of integrated-circuit production. For the synchronous FIFO, a model was built and successfully used in the controller for the UNICON laser memory. For the asynchronous FIFO, a model was built and also successfully used in a high-performance magnetic tape controller.

Lim, R. S.↗