Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Baseline Calibration of the GeoSAR Interferometric Mapping Instrument

GeoSAR is a dual frequency, X-Band and P-Band, interferometric mapping radar flown on a Gulfstream II with a nominal flying altitude of 10000 and a swath width of 10 km on both left and right sides of the aircraft. The radar is designed to generate high resolution and high accuracy digital elevation maps both above and below the vegetation canopy. In order to generate the high accuracy digital elevations models it is necessary to have extremely precise knowledge of the interferometric baseline, approximately .1 mm for the X-band system and 3 mm for the P-band system. Baseline knowledge to this level of accuracy is achieved through a combination of active baseline measurement using a Laser Baseline Metrology System (LBMS) and baseline calibration using an accurately surveyed array of corner reflectors. In this paper, we describe the LBMS system used to measure the dynamic component of the interferometric baseline and the least squares procedure used to estimate all three components of the interferometric baseline based on differences between calculated and surveyed corner reflector locations.

Hensley, Scott↗

Calibration of the Geosar Dual Frequency Interferometric SAR

GeoSAR is an airborne, interferometric Synthetic Aperture Radar (INSAR) system for terrain mapping, currently under development by a consortium including NASA's Jet Propulsion Laboratory (JPL), Calgis, Inc., and the California Department of Conservation (CalDOC) with funding provided by the Topographic Engineering Center (TEC) of the U.S. Army Corps of Engineers and the Defense Advanced Research Projects Agency (DARPA). The radar simultaneously maps swaths on both sides of the aircraft at two frequencies, X-Band and P-Band. For the P-Band system, data is collected for two across track interferometric baselines and at the crossed polarization. The aircraft position and attitude are measured using two Honeywell Embedded GPS Inertial Navigation Units (EGI) and an Ashtech Z12 GPS receiver. The mechanical orientation and position of the antennas are actively measured using a Laser Baseline Metrology System (LBMS). In the GeoSAR motion measurement software, these data are optimally combined with data from a nearby ground station using Ashtech PNAV software to produce the position, orientation, and baseline information are used to process the dual frequency radar data. Proper calibration of the GeoSAR system is essential to obtaining digital elevation models (DEMS) with the required sub-meter level planimetric and vertical accuracies. Calibration begins with the determination of the yaw and pitch biases for the two EGI units. Common range delays are determined for each mode, along with differential time and phase delays between channels. Because the antennas are measured by the LBMS, baseline calibration consists primarily of measuring a constant offset between mechanical center and the electrical phase center of the antennas. A phase screen, an offset to the interferometric phase difference which is a function of absolute phase, is applied to the interferometric data to compensate for multipath and leakage. Calibration parameters are calculated for each of the ten processing modes, each of the operational bandwidths (80 and 160 MHZ), and each aircraft altitude. In this talk we will discuss the layout calibration sites, the synthesis of data from multiple flights to improve the calibration, methods for determining time and phase delays, and techniques for determining radiometric and polarimetric quantities. We will describe how calibration quantities are incorporated into the processor and pre-processor. We will demonstrate our techniques applied to GeoSar data and assess the stability and accuracy of the calibration. This will be compared to the modeled performance determined from calibrating the output of a point target simulator. The details of baseline determination and phase screen calculation are covered in related talks.

Chapine, Elaine↗

Demonstration of Imaging Fourier Transform Spectrometer (FTS) Performance for Planetary and Geostationary Earth Observing

The combination of massively parallel spatial sampling and accurate spectral radiometry offered by imaging FTS makes it extremely attractive for earth and planetary remote sensing. We constructed a breadboard instrument to help assess the potential for planetary applications of small imaging FTS instruments in the 1 - 5 micrometer range. The results also support definition of the NASA Geostationary Imaging FTS (GIFTS) instrument that will make key meteorological and climate observations from geostationary earth orbit. The Planetary Imaging FTS (PIFTS) breadboard is based on a custom miniaturized Bomen interferometer that uses corner cube reflectors, a wishbone pivoting voice-coil delay scan mechanism, and a laser diode metrology system. The interferometer optical output is measured by a commercial infrared camera procured from Santa Barbara Focalplane. It uses an InSb 128x128 detector array that covers the entire FOV of the instrument when coupled with a 25 mm focal length commercial camera lens. With appropriate lenses and cold filters the instrument can be used from the visible to 5 micrometers. The delay scan is continuous, but slow, covering the maximum range of +/- 0.4 cm in 37.56 sec at a rate of 500 image frames per second. Image exposures are timed to be centered around predicted zero crossings. The design allows for prediction algorithms that account for the most recent fringe rate so that timing jitter produced by scan speed variations can be minimized. Response to a fixed source is linear with exposure time nearly to the point of saturation. Linearity with respect to input variations was demonstrated to within 0.16% using a 3-point blackbody calibration. Imaging of external complex scenes was carried out at low and high spectral resolution. These require full complex calibration to remove background contributions that vary dramatically over the instrument FOV. Testing is continuing to demonstrate the precise radiometric accuracy and noise characteristics.

Revercomb, Henry E.↗

Shape Validation and RF Performance of Inflatable Antennas

Inflatable aperture antennas are an emerging technology that is being investigated for potential use in science and exploration missions. In particular, for missions to Mars and beyond, large deployable aperture antennas can provide the antenna gain required for high data rate communications, where the necessary antenna diameter exceeds the available volume of typical launch vehicle platforms. As inflatable aperture antennas have not been proven fully qualified for space missions, the author's Master's Thesis assessed the Ruze equation in characterizing this antenna technology. Inflatable aperture antennas do not follow a parabolic shape, and so the Ruze equation is not applicable due to the macroscopic shape errors of this technology. Therefore, geometric evaluations of the surface profile cannot simply correlate antenna gain degradation with the root-mean-square shape error with a parabolic surface. Consequently, the focus of this work was to derive an accurate mathematical model of an inflatable aperture antenna in order to characterize its Radio Frequency (RF) performance. Calculus of Variations methodologies were used to derive the surface profile shape of the inflatable aperture antenna. Physical Optics techniques were used to generate the antenna pattern profile. Validation testing of the predicted inflatable antenna shape model was performed through use of Laser Radar metrology measurements on an inflatable test article. Assessments of the RF performance of the inflatable aperture antenna, compared with nominally shaped paraboloidal antennas, were obtained through simulations of both technologies using a common diameter, depth, and arc length. Assessments of the RF performance of the inflatable aperture antenna was also performed against itself for changes in distance of the antenna feed location in the axial direction. Whereas the Ruze equation is limited to assessing gain reduction, this effort will also assess beam spreading and first side lobe angle and magnitude. The ability to characterize the RF response of this antenna will provide for an improved understanding of this technology. The accurate representation of the shape of this type of antenna technology will help to identify the most appropriate ways in which this technology could be utilized in planning future communication architectures for NASA missions to Mars and beyond.

Welch, Bryan W.↗

Shape Validation and RF Performance of Inflatable Antennas

Inflatable aperture antennas are an emerging technology that is being investigated for potential use in science and exploration missions. In particular, for missions to Mars and beyond, large deployable aperture antennas can provide the antenna gain required for high data rate communications, where the necessary antenna diameter exceeds the available volume of typical launch vehicle platforms. As inflatable aperture antennas have not been proven fully qualified for space missions, the author's Master's Thesis assessed the Ruze equation in characterizing this antenna technology. Inflatable aperture antennas do not follow a parabolic shape, and so the Ruze equation is not applicable due to the macroscopic shape errors of this technology. Therefore, geometric evaluations of the surface profile cannot simply correlate antenna gain degradation with the root-mean square shape error with a parabolic surface. Consequently, the focus of this work was to derive an accurate mathematical model of an inflatable aperture antenna to in order to characterize its Radio Frequency (RF) performance. Calculus of Variations methodologies were used to derive the surface profile shape of the inflatable aperture antenna. Physical Optics techniques were used to generate the antenna pattern profile. Validation testing of the predicted inflatable antenna shape model was performed through use of Laser Radar metrology measurements on an inflatable test article. Assessments of the RF performance of the inflatable aperture antenna, compared with nominally shaped paraboloidal antennas, were obtained through simulations of both technologies using a common diameter, depth, and arc length. Assessments of the RF performance of the inflatable aperture antenna was also performed against itself for changes in distance of the antenna feed location in the axial direction. Whereas the Ruze equation is limited to assessing gain reduction, this effort will also assess beam spreading and first side lobe angle and magnitude. The ability to characterize the RF response of this antenna will provide for an improved understanding of this technology. The accurate representation of the shape of this type of antenna technology will help to identify the most appropriate ways in which this technology could be utilized in planning future communication architectures for NASA missions to Mars and beyond.

Welch, Bryan↗

SIM vs. SOS: A Space Interferometry Trade Study

This study was undertaken at the Jet Propulsion Laboratory to identify salient features of two competing instrument designs and to select the design that best meets the goals of the Space Interferometry Mission.

trade-study↗

Novel Wide Field-of-view Laser Retroreflector for the Space Interferometry Mission

A new type of laser retroreflector has been developed for JPL's future Space Interferometry Mission. The retroreflector consists of an assembly of prisms to form multiple hollow cornercubes. This way the limited field of view (FOV) of about 60deg of a single corner can be overcome, to comply with the geometry of an optical truss.

interferometry↗

Qualification and Selection of Flight Diode Lasers for Space Applications

The reliability and lifetime of laser diodes is critical to space missions. The Nuclear Spectroscopic Telescope Array (NuSTAR) mission includes a metrology system that is based upon laser diodes. An operational test facility has been developed to qualify and select, by mission standards, laser diodes that will survive the intended space environment and mission lifetime. The facility is situated in an electrostatic discharge (ESD) certified clean-room and consist of an enclosed temperature-controlled stage that can accommodate up to 20 laser diodes. The facility is designed to characterize a single laser diode, in addition to conducting laser lifetime testing on up to 20 laser diodes simultaneously. A standard laser current driver is used to drive a single laser diode. Laser diode current, voltage, power, and wavelength are measured for each laser diode, and a method of selecting the most adequate laser diodes for space deployment is implemented. The method consists of creating histograms of laser threshold currents, powers at a designated current, and wavelengths at designated power. From these histograms, the laser diodes that illustrate a performance that is outside the normal are rejected and the remaining lasers are considered spaceborne candidates. To perform laser lifetime testing, the facility is equipped with 20 custom laser drivers that were designed and built by California Institute of Technology specifically to drive NuSTAR metrology lasers. The laser drivers can be operated in constant-current mode or alternating-current mode. Situated inside the enclosure, in front of the laser diodes, are 20 power-meter heads to record laser power throughout the duration of lifetime testing. Prior to connecting a laser diode to the current source for characterization and lifetime testing, a background program is initiated to collect current, voltage, and resistance. This backstage data collection enables the operational test facility to have full laser diode traceablity.

Liebe, Carl C.↗

Analysis of two-color photoelectron spectroscopy for attosecond metrology at seeded free-electron lasers

The generation of attosecond pulse trains at free-electron lasers opens new opportunities in ultrafast science, as it gives access, for the first time, to reproducible, programmable, extreme ultraviolet (XUV) waveforms with high intensity. In this work, we present a detailed analysis of the theoretical model underlying the temporal characterization of the attosecond pulse trains recently generated at the free-electron laser FERMI. In particular, the validity of the approximations used for the correlated analysis of the photoelectron spectra generated in the two-color photoionization experiments are thoroughly discussed. The ranges of validity of the assumptions, in connection with the main experimental parameters, are derived.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical Testing of Retroreflectors for Cryogenic Applications

A laser tracker (LT) is an important coordinate metrology tool that uses laser interferometry to determine precise distances to objects, points, or surfaces defined by an optical reference, such as a retroreflector. A retroreflector is a precision optic consisting of three orthogonal faces that returns an incident laser beam nearly exactly parallel to the incident beam. Commercial retroreflectors are designed for operation at room temperature and are specified by the divergence, or beam deviation, of the returning laser beam, usually a few arcseconds or less. When a retroreflector goes to extreme cold (.35 K), however, it could be anticipated that the precision alignment between the three faces and the surface figure of each face would be compromised, resulting in wavefront errors and beam divergence, degrading the accuracy of the LT position determination. Controlled tests must be done beforehand to determine survivability and these LT coordinate errors. Since conventional interferometer systems and laser trackers do not operate in vacuum or at cold temperatures, measurements must be done through a vacuum window, and care must be taken to ensure window-induced errors are negligible, or can be subtracted out. Retroreflector holders must be carefully designed to minimize thermally induced stresses. Changes in the path length and refractive index of the retroreflector have to be considered. Cryogenic vacuum testing was done on commercial solid glass retroreflectors for use on cryogenic metrology tasks. The capabilities to measure wavefront errors, measure beam deviations, and acquire laser tracker coordinate data were demonstrated. Measurable but relatively small increases in beam deviation were shown, and further tests are planned to make an accurate determination of coordinate errors.

Ohl, Raymond G.↗