Search NASA⌕ Search

SEARCH · Search NASA

Results for “lasers']”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Greater than 1000-fold Gain in a Free-Electron Laser Driven by a Laser-Plasma Accelerator with High Reliability

Compact free-electron lasers (FELs) based on plasma-based accelerators have been envisioned for many years. While recent milestone experiments have demonstrated feasibility, further progress is needed to establish laser-plasma-accelerator-driven FELs as reliable light sources. Demonstrating both full FEL saturation and reliable operation commensurate with conventional FEL facilities is critical. We report progress on both of these fronts. FEL gain exceeding 1000 at a wavelength of 420 nm in the self-amplified spontaneous emission regime has been measured. Lower and upper bounds for the characteristic exponential gain length were measured at 16.7-22.5 cm. Additionally, reliability of the laser-plasma-accelerator-driven FEL, defined here as the percentage of shots displaying FEL gain, reached an unprecedented level of greater than 90% over the course of an hour while operating at 1 Hz repetition rate.

Barber, S K↗

Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers

High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.

36 MATERIALS SCIENCE↗

Residual stresses in Cu matrix composite surface deposits after laser melt injection

Abstract Tungsten carbide particles reinforced metal matrix composite (MMC) coatings can significantly improve surface wear resistance owing to their increased surface hardness. However, the presence of macro‐ and micro‐residual stresses in MMC coatings can have detrimental effects, such as reducing service life. In this study, neutron diffraction was used to determine the residual stresses in spherical fused tungsten carbide (sFTC) reinforced Cu matrix composite surface deposits after laser melt injection. We also developed a thermo‐mechanical coupled finite element model to predict residual stresses. Our findings reveal that sFTC/Cu composite deposits produced with a preheating temperature of 400°C have low residual stresses, with a maximum tensile residual stress of 98 MPa in the Cu matrix on the top surface. In contrast, the sFTC/bronze (CuAl10Ni5Fe4) composite deposit exhibits very high residual stresses, with a maximum tensile residual stress in the Cu matrix on the top surface reaching 651 MPa. These results provide a better understanding of the magnitudes and distributions of residual stresses in sFTC‐reinforced Cu matrix composite surface deposits manufactured via laser melt injection.

Zhang, Xingxing↗

Laser micro-machining and damage testing of rounded shadow cone blockers on silica glass for arresting laser damage growth by redirection of light

Structured conical blockers manufactured on optical input surfaces are being used to shadow, and thereby, arrest growth of exit surface damage on large optics for applications in high-energy laser systems to extend their lifetime usage. However, as the size of the Shadow Cone Blocker (SCB) is increased, the deflected light must be carefully managed to prevent consequential damage from downstream intensification. Here, we design and fabricate a distinct input SCB geometry to alleviate this problem, enabling larger damage site mitigation. The demonstrated ~1 mm diameter SCB was manufactured with a convergent approach using a CO 2 pulsed laser ablative scanning sequence on a fused silica window. The SCB design was refined to maximize resistance to both input and exit surface damage initiations on 1 cm thick fused silica windows when exposed to 351 nm irradiation and validated with laser damage testing. The design showed to prevent damage onset to the exit surface for incident fluences on the SCB of 10.7 ± 1.3 J·cm -2 and is resistant to damage on the input surface exceeding 30 J·cm -2 input fluence.

36 MATERIALS SCIENCE↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

System and method for large-area pulsed laser melting of metallic powder in a laser powder bed fusion application

The present disclosure relates to systems and methods for performing large area laser powder bed fusion (LBPF) to form a plurality of layers of a 3D part in a layer-by-layer fashion using meltable powder particles. In one implementation the system makes use of a first light source, which may be a diode laser subsystem, for generating a first light pulse of a first duration. The first light is used to preheat a substrate underneath a new layer of powder particles, wherein the substrate is formed from a previously fused quantity of the powder particles. A second light source, which may be a pulse laser, generates a second light pulse subsequent to the first light pulse. The second light pulse has a second duration shorter than the first duration by a factor of at least about 10, and fully melts the new layer of powder particles in addition to the substrate, to achieve a smooth printed layer. The wavelength of the first light pulse also differs from a wavelength of the second light pulse.

Khairallah, Saad A.↗

Active control of laser beam pointing for the Zettawatt-Equivalent Ultrashort pulse laser System: a proof-of-principle study with 16-inch optics

We present a proof-of-principle study of active beam-pointing control for the Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) using a piezo-actuated 16-inch mirror. To the best of our knowledge, this is the largest actively controlled mirror reported in a high-power laser system. A simple proportional feedback control was implemented based on a field-programmable gate array, which reduced the standard deviation of beam-pointing fluctuations by 91% to 0.075 μrad in the horizontal direction and by 78% to 0.25 μrad in the vertical direction. We also demonstrated the elimination of long-term pointing jitter caused by temperature drift using the same apparatus.

laser pointing control↗

Colloidal Semiconductor Nanocrystal Lasers and Laser Diodes

Lasers and optical amplifiers based on solution-processable materials have been long-desired devices for their compatibility with virtually any substrate, scalability, and ease of integration with on-chip photonics and electronics. These devices have been pursued across a wide range of materials including polymers, small molecules, perovskites, and chemically prepared colloidal semiconductor nanocrystals, also commonly referred to as colloidal quantum dots. The latter materials are especially attractive for implementing optical-gain media as in addition to being compatible with inexpensive and easily scalable chemical techniques, they offer multiple advantages derived from a zero-dimensional character of their electronic states. These include a size-tunable emission wavelength, low optical gain thresholds, and weak sensitivity of lasing characteristics to variations in temperature. Here we review the status of colloidal nanocrystal lasing devices, most recent advances in this field, outstanding challenges, and the ongoing progress toward technological viable devices including colloidal quantum dot laser diodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of neutron-yield enhancement by laser preheating and magnetization of laser-driven cylindrical implosions

Magnetized liner inertial fusion (MagLIF) is a fusion concept that uses magnetized, preheated fuel to reduce the implosion velocities and convergence ratios required for ignition. A scaled, laser-driven experimental platform to study MagLIF has been demonstrated on the OMEGA laser system, providing comprehensive experimental data on MagLIF scaling, utilizing the higher shot rate on OMEGA compared to the Z machine. Using this platform, a broader experimental space for MagLIF has been studied. Presented in this article are experimental results that demonstrate that the combination of preheat and magnetization enhances the neutron yield by 470% compared to a reference implosion, significantly more than the yield enhancement by the field or preheat alone. These results are achieved while maintaining a relatively low convergence ratio (<20). Here, the experiments were supported by one-, two-, and three-dimensional radiation-hydrodynamics simulations, all of which suggest that multiple sources of mix play different key roles depending on the scale of the MagLIF experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat transfer in water under laser heating through fibres for endovenous laser coagulation

We report the results of studying heat transfer in water heated by a cw laser with wavelengths of 1.55 and 1.94 μm through optical fibres with end-face and radial outputs. It is shown that, depending on the power and wavelength of the radiation, heat transfer is implemented via convection, bubble boiling, or explosive boiling and occurs asymmetrically, mainly in the forward − upward direction for the fibre with the end-face output and upward for the radial output. (laser medicine)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Decay of a laser beam under stimulated temperature scattering in toluene as a result of two-photon pump absorption and nonsteady-state laser pulse interaction with matter

The decay of the pump-beam spatial structure under conditions of stimulated temperature scattering of a pulsed laser beam in toluene as a result of two-photon absorption of pump radiation and time-dependent interaction of a laser pulse with a medium is considered. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing shock dynamics inside micro-wire targets after high-intensity laser irradiation using small angle x-ray scattering of a free-electron laser

In this paper, we present an experiment that explores the plasma dynamics of a 7μm diameter carbon wire after being irradiated with a near-relativistic-intensity short pulse laser. Using an x-ray free electron laser pulse to measure the small angle x-ray scattering signal, we observe that the scattering surface is bent and prone to instability over tens of picoseconds. The dynamics of this process are consistent with the presence of a sharp, propagating shock front inside the wire, moving at a speed close to the hole boring velocity or that expected from a thermal shock at a few tens of Mbar.

47 OTHER INSTRUMENTATION↗

Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. Furthermore, this approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.

Free-electron lasers↗

Two-color x-ray free-electron laser by photocathode laser emittance spoiler

Multispectral x-ray pump-probe experiments call for synchronized two-color free-electron lasers (FEL). This mode often implies a laborious setup or an inefficient use of the undulator. We report on a simple and noninvasive approach tested at SwissFEL for a two-color x-ray delivering almost 60% of the pulse energy compared with a single color. In this new method, a ps UV pulse is overlapped to the photocathode drive laser increasing the beam emittance, which locally inhibits the FEL process. This scheme permits high-stability in energy and spectrum and the control of the two-color duration and intensity ratio. It enables shot-to-shot switching between one and two-color FEL and, since not associate to beam losses, it is compatible with high repetition-rate and high average-power FELs.

43 PARTICLE ACCELERATORS↗

Extraction of the electron excess temperature in terahertz quantum cascade lasers from laser characteristics

Abstract We propose a method to extract the upper laser level’s (ULL’s) excess electronic temperature from the analysis of the maximum light output power ( P max ) and current dynamic range Δ J d = ( J max − J th ) of terahertz quantum cascade lasers (THz QCLs). We validated this method, both through simulation and experiment, by applying it on THz QCLs supporting a clean three-level system. Detailed knowledge of electronic excess temperatures is of utmost importance in order to achieve high temperature performance of THz QCLs. Our method is simple and can be easily implemented, meaning an extraction of the excess electron temperature can be achieved without intensive experimental effort. This knowledge should pave the way toward improvement of the temperature performance of THz QCLs beyond the state-of-the-art.

47 OTHER INSTRUMENTATION↗

w22_laser-radiography: Laser-Based MeV Radiography [Slides]

X-ray sources based on high-power short pulse lasers have unique advantages over conventional sources, like small spot size, flexible configuration, and tailorable spectra. Development of these sources will allow LANL to fulfill an urgent need to deploy flexible, compact, x-ray sources for static and dynamic radiography at our firing sites and facilities such as pRad and U1a. Our IC allocation supports the development of a predictive modeling capability of these laser-based sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗