Search NASA⌕ Search

SEARCH · Search NASA

Results for “latent load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

138 records · Page 8

Mini-Channel Flow Boiling in 1g and μg

Subcooled flow boiling combines complex processes governed by a strong coupling of heat and mass transfer, hydrodynamics, and liquid-vapor transitions. The gravitational body force plays an important role in these processes. By exploiting the latent heat of vaporization, subcooled flow boiling can transfer up to several orders-of-magnitude more heat compared to forced liquid flow. It is widely used in Earth-based thermal equipment to reduce the cost, size, and power required to move heat. Subcooled flow boiling is now considered a promising technology for space applications since it offers a means to control the motion of bubbles near the heated surface and thereby enhance nucleate boiling. However, a lack of data and predictive models on the role that gravity plays in these phenomena hinders the use of flow boiling in a microgravity environment. We will present results of experiments on transients in nucleate boiling that were carried out in the Flow Boiling Module (FBM) on the International Space Station (ISS). The unique ISS FBM ability is to couple large heat loads with flow visualization in testing flow boiling under strict control of experimental conditions in long-duration microgravity. Comparison of results of microgravity experiments with data obtained in a similar setup on the NASA GRC demonstrates the role of gravity in nucleate boiling. The work is supported by the NASA Flight Opportunities program (grant 80NSSC21K0501) and NSF/CASIS program (NSF CBET grants 1832260, 2126461, 2126462).

Two-phase flow and phase transition↗

Development Status of the Carbon Dioxide and Moisture Removal Amine Swing-Bed System (CAMRAS)

Under a cooperative agreement with NASA, Hamilton Sundstrand has successfully designed, fabricated, tested and delivered three, state-of-the-art, solid amine prototype systems capable of continuous CO2 and humidity removal from a closed, habitable atmosphere. Two prototype systems (CAMRAS #1 and #2) incorporated a linear spool valve design for process flow control through the sorbent beds, with the third system (CAMRAS #3) employing a rotary valve assembly that improves system fluid interfaces and regeneration capabilities. The operational performance of CAMRAS #1 and #2 has been validated in a relevant environment, through both simulated human metabolic loads in a closed chamber and through human subject testing in a closed environment. Performance testing at Hamilton Sundstrand on CAMRAS #3, which incorporates a new valve and modified canister design, showed similar CO2 and humidity removal performance as CAMRAS #1 and #2, demonstrating that the system form can be modified within certain bounds with little to no effect in system function or performance. Demonstration of solid amine based CO2 and humidity control is an important milestone in developing this technology for human spaceflight. The systems have low power requirements; with power for air flow and periodic valve actuation and indication the sole requirements. Each system occupies the same space as roughly four shuttle non-regenerative LiOH canisters, but have essentially indefinite CO2 removal endurance provided a regeneration pathway is available. Using the solid amine based systems to control cabin humidity also eliminates the latent heat burden on cabin thermal control systems and the need for gas/liquid phase separation in a low gravity environment, resulting in additional simplification of vehicle environmental control and life support system process requirements.

Papale, William↗

Non-Venting Thermal and Humidity Control for EVA Suits

Future EVA suits need processes and systems to control internal temperature and humidity without venting water to the environment. This paper describes an absorption-based cooling and dehumidification system as well as laboratory demonstrations of the key processes. There are two main components in the system: an evaporation cooling and dehumidification garment (ECDG) that removes both sensible heat and latent heat from the pressure garment, and an absorber radiator that absorbs moisture and rejects heat to space by thermal radiation. This paper discusses the overall design of both components, and presents recent data demonstrating their operation. We developed a design and fabrication approach to produce prototypical heat/water absorbing elements for the ECDG, and demonstrated by test that these elements could absorb heat and moisture at a high flux. Proof-of-concept tests showed that an ECDG prototype absorbs heat and moisture at a rate of 85 W/ft under conditions that simulate operation in an EVA suit. The heat absorption was primarily due to direct absorption of water vapor. It is possible to construct large, flexible, durable cooling patches that can be incorporated into a cooling garment with this system. The proof-of-concept test data was scaled to calculate area needed for full metabolic loads, thus showing that it is feasible to use this technology in an EVA suit. Full-scale, lightweight absorber/radiator modules have also been built and tested. They can reject heat at a flux of 33 W/ft while maintaining ECDG operation at conditions that will provide a cool and dry environment inside the EVA suit.

Izenson, Mike↗

Quantifying energy and mass transfer in crop canopies: sensors for measurement of temperature and air velocity

Here we report on the in situ performance of inexpensive, miniature sensors that have increased our ability to measure mass and energy fluxes from plant canopies in controlled environments: 1. Surface temperature. Canopy temperature measurements indicate changes in stomatal aperture and thus latent and sensible heat fluxes. Infrared transducers from two manufacturers (Exergen Corporation, Newton, MA; and Everest Interscience, Tucson, AZ, USA) have recently become available. Transducer accuracy matched that of a more expensive hand-held infrared thermometer. 2. Air velocity varies above and within plant canopies and is an important component in mass and energy transfer models. We tested commercially-available needle, heat-transfer anemometers (1 x 50 mm cylinder) that consist of a fine-wire thermocouple and a heater inside a hypodermic needle. The needle is heated and wind speed determined from the temperature rise above ambient. These sensors are particularly useful in measuring the low wind speeds found within plant canopies. 3. Accurate measurements of air temperature adjacent to plant leaves facilitates transport phenomena modeling. We quantified the effect of radiation and air velocity on temperature rise in thermocouples from 10 to 500 micrometers. At high radiation loads and low wind speeds, temperature errors were as large as 7 degrees C above air temperature.

NASA Program CELSS↗

Tailoring the Interfacial Interactions of Porous Polymer Membranes to Accelerate Atomic Layer Deposition: The Latent Path to Antifouling Membranes

Atomic layer deposition (ALD) is a powerful strategy to engineer hybrid organic-inorganic membranes with emergent functionalities. The combination of atomic-level thickness control, a wide materials palette, and unprecedented conformality allows the physiochemical properties (e.g., hydrophilicity) of mesoporous polymer membranes to be precisely tuned. The nucleation of ALD material growth on polymer surfaces relies on Lewis acid-base interactions and remains an overlooked motif with tremendous potential to accelerate ALD nucleation and growth. Strategies to enhance these interactions could enable desirable properties such as antifouling behavior to be imparted on inert polymer surfaces that lack the necessary functional groups for ALD nucleation. Here, in this study, we demonstrate that the reactivity of polyacrylonitrile (PAN) membranes toward ALD metal oxide (MO) precursors with Lewis acid characteristics is enhanced by introducing strong Lewis base functional groups (amidoxime: Am) on the PAN backbone (Am-PAN). The resulting Lewis acid-base interactions accelerate the MO nucleation in Am-PAN and reduce the number of deposition cycles required to achieve hydrophilicity compared with the untreated PAN membrane. Unveiling the reaction mechanism, in situ Fourier transform infrared (FTIR) spectroscopy measurements established enhanced interaction dynamics between the ALD MO precursors and the Am-PAN membrane, unlike the PAN membrane. Spectroscopic ellipsometry and thermogravimetric analysis measurements revealed higher MO loadings in Am-PAN membranes compared to PAN membranes for the same number of ALD cycles. We found that strong Lewis acid-base interactions accelerated the ALD for a range of materials including Al 2 O 3 , TiO 2 , SnO 2 , and ZnO. More broadly, our work demonstrates that tailoring metal-precursor-polymer interactions is a powerful strategy to accelerate and modulate the ALD. We used this design strategy to fabricate Al 2 O 3 -Am-PAN hybrid membranes that showed 2-fold higher antifouling capability compared to pristine PAN membranes prepared with an equivalent number of Al 2 O 3 ALD cycles. Our approach expands the scope of design options for fouling-resistant porous hybrid inorganic-organic membranes and may ultimately reduce the operational costs of water treatment.

36 MATERIALS SCIENCE↗

Glauber’s Salt Composites for HVAC Applications: A Study on the Use of the T-History Method with a Modified Data Evaluation Methodology

Phase change materials (PCMs) can be utilized in buildings for peak load shifting in air conditioning systems, and the use of salt hydrate-based PCMs can reduce the cost of thermal energy storage devices. Glauber’s salt is an economical salt hydrate PCM with a melting point of around 32 °C. However, the desired melting range typically falls between 18 and 22 °C for building air conditioning applications. Although many researchers have characterized Glauber’s salt and its composites with modified melting points, enthalpy–temperature curves for composites of Glauber’s salt and NaCl are unavailable. In this study, we report the melting and solidification enthalpy–temperature curves for two different composites of Glauber’s salt and NaCl with a melting point of 21 °C obtained by the T-history method. Both composites contain NaCl to suppress the melting point, borax to reduce supercooling, and sodium polyacrylate as a thickener to enhance cyclic stability. The first composite with 12 wt.% NaCl demonstrated 139 kJ·kg−1 of latent heat of fusion, and the second composite with 9 wt.% NaCl demonstrated 171 kJ·kg−1. Both the composites have high volumetric energy densities compared to their organic counterparts with similar melting points.

Chemistry↗

Performing k eff Validation of As-Loaded Criticality Safety Calculations Using UNF-ST&DARDS: Sensitivity Calculations

The general method for performing validation of as loaded criticality safety calculations using UNF ST&DARDS is presented in a paper by Clarity, which includes a description of the UNF-ST&DARDS system. Proof-of-principle analyses were performed in the summer of 2019 for MPC-32 dual purpose canisters (DPCs) containing pressurized water reactor (PWR) fuel assemblies. Summaries of these results are presented in this and a companion paper for this conference. The current paper describes the TSUNAMI-3D calculations performed to generate sensitivity data, and the companion paper discusses the selection of critical experiments applicable for validation of the 11 MPC-32 DPCs considered. The generation of sensitivity data for as-loaded spent nuclear fuel (SNF) DPCs is a challenge given the detailed model of the fuel compositions generated by UNF ST&DARDS. Each fuel assembly is modeled with its own irradiation history in 18 axial nodes, unless the fuel assembly is damaged and thus considered as fresh by design basis. This results in a set of 576 fuel compositions, each of which must be processed separately in a multigroup (MG) calculation. Therefore, a continuous-energy (CE) TSUNAMI-3D method was chosen to alleviate this challenge. Two CE TSUNAMI-3D methods are available in SCALE 6.2.3: the iterated fission probability (IFP) and contribution-linked eigenvalue sensitivity/uncertainty estimation via track-length importance characterization (CLUTCH). Since the IFP method is not feasible because of memory requirements associated with its implementation in SCALE, the CLUTCH method was selected for these calculations. CLUTCH has been implemented in SCALE in parallel, allowing long calculations to be performed in reasonable timeframes. The two primary user inputs necessary for CLUTCH calculations are the F*(r) mesh and the number of latent generations used in determining the F*(r) function. This F*(r) function is used as the importance function for fission chains originating in a given volume element (voxel), and it is calculated using the IFP method in the skipped generations. A large number of skipped generations is thus required to ensure accurate calculation of this importance function. In these calculations, 500 generations were used to calculate the F*(r) function. For more information regarding the calculation of F*(r), see Jones [4]. The remainder of this paper is focused on the selection of the F*(r) mesh and the number of latent generations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Possible Influences of Air Pollution, Dust and Sandstorms on the Indian Monsoon

In Asian monsoon countries, such as China and India, human health and safety problems caused by air pollution are becoming increasingly serious, due to the increased loading of atmospheric pollutants from waste gas emissions and from rising energy demand associated with the rapid pace of industrialization and modernization. Meanwhile, uneven distribution of monsoon rain associated with flash floods or prolonged drought, has caused major loss of human life and damage to crops and.property with devastating societal impacts. Historically, air-pollution and monsoons research are treated as separate problems. However recent studies have suggested that the two problems may be intrinsically linked and need to be studied jointly. Fundamentally, aerosols can affect precipitation through radiative effects cif suspended particles in the atmosphere (direct effect) and/or by interfering and changing: the cloud and precipitation formation processes (indirect effect). Based on their optical properties, aerosols can be classified into two types.: those that absorb solar radiation, and those that do not. Both types of aerosols scatter sunlight and reduce the amount of solar radiation from reaching the Earth's surface, causing it to cool. The surface cooling increases atmospheric stability and reduces convection potential, Absorbing aerosols, however, in addition to cooling the surface, can heat the atmosphere. The heating of the atmosphere may reduce the amount of low clouds by increased evaporation in cloud drops. The heating, however, may induce rising motion, enhance low-level moisture, convergence and, hence, increases rainfall, The latent heating from enhanced rainfall may excite feedback processes in the large-scale circulation, further amplify.the initial response to aerosol heating and producing more rain. Additionally, aerosols can increase the concentration of cloud condensation nuclei (CCN), increase cloud amount and decrease coalescence and collision rates, leading to reduced precipitation. However, in the presence of increasing moist and warm air, the reduced coalescence/collision may lead to supercooled drops at higher altitudes where ice precipitation falls and melts. The latent heat release from freezing aloft and melting below implies greater upward heat transport in polluted clouds and invigorate deep convection. In this way, aerosols may lead to increased local convection. Hence, depending on the ambient large-scale conditions and dynamical feedback processes, aerosols' effect on precipitation can be positive, negative or mixed. In the Asian monsoon and adjacent regions, the aerosol forcing and responses of the water cycle are even more complex, Both direct and indirect effects may take place locally and simultaneously, interacting with each other. in addition to local effects, monsoon rainfall may be affected by aerosols transported from other regions and intensified through large-scale circulation and moisture feedback. Thus, dust transported by the large-scale circulation from the adjacent deserts to northern India may affect rainfall over the Bay of Bengal; sulphate and black carbon front industrial pollution in central, southern China and northern India may affect the rainfall regime over the Korean peninsula and Japan; organic and black carbon front biomass burning from Indo-China may modulate the pre-monsoon rainfall regime over southern China and coastal regions, contributing to variability in differential heating and cooling of the atmosphere and to the land-sea thermal contrast. During the pre-monsoon season and monsoon breaks, it has been suggested that radiative forcing by absorbing aerosols have nearly the same order of magnitude as the forcing due to latent heating from convection and surface fluxes. The magnitude of the total aerosol radiative cooling due to sulphates and soot is of the order of 20-40 W/m2 over the Asian monsoon land region in the pre-monsoon season, compared to about 1-2 W/m2 for global warng. However, the combined forcing at the surface and in the atmosphere, including all species. if aerosols, and details of aerosol mixing, and impacts on the energy and water cycles in the monsoon land regions, are not well known.

Lau, William K. M.↗

Immune System Dysregulation and Herpesvirus Reactivation Persist During Long-Duration Spaceflight

Background: Immunity, latent herpesvirus reactivation, physiological stress and circadian rhythms were assessed during six month spaceflight onboard ISS. Blood and saliva samples were collected early, mid and late in-flight and returned for immediate analysis. Mid-point study data (10 of 17 planned subjects) will be presented. Results: Some shifts in leukocyte distribution occurred during flight, including alterations in CD8+ T cell maturation. General T cell function was consistently reduced early in-flight. Levels CD8+/IFNg+ producing T cells were depressed early in-flight, and immediately upon landing. Persistent mitogen-dependant reductions were observed in IFNg, IL-17a, IL-10, TNFa and IL-6 production. Monocyte production of IL-10 was reduced, whereas IL-8 levels were increased. Levels of mRNA for the TNFa, IL-6 and IFNg were transiently elevated early in-flight, and the dynamics of TNF and IL-6 gene expression were somewhat antagonistic to their corresponding receptors during flight. The number of virus-specific CD8+ T-cells was measured using MHC tetramers, while their function was measured using intracellular cytokine analysis following peptide stimulation. Both the number and function of EBV-specific cells decreased during flight as compared to preflight levels. The number of CMV-specific T-cells generally increased as the mission progressed while their function was variable. Viral (EBV) load in blood was elevated postflight. Anti-EBV VCA antibodies were significantly elevated by R+0; anti-EA antibodies were not significantly elevated at landing; and anti-CMV antibodies were somewhat elevated during flight. Higher levels of salivary EBV DNA were found during flight. VZV DNA reactivation occurred in ~50 % of astronauts during flight, continuing for up to 30 days post-flight. CMV was shed in 35 % the in-flight and 30% of postflight urine samples of the crewmembers. There was generally a higher level of cortisol as measured in urine and saliva in the astronauts during flight, but plasma cortisol was relatively unchanged during flight. Circadian rhythm of salivary cortisol was altered during flight. Conclusion. Some alterations in immunity do not resolve during six month spaceflight, consequentially resulting in persistent herpesvirus reactivation. Ongoing immune dysregulation may represent specific clinical risks for exploration-class space missions.

Crucian, B. E.↗

Assessment of climate variability of the Greenland ice sheet: Integration of in situ and satellite data

The proposed research involves the application of multispectral satellite data in combination with ground truth measurements to monitor surface properties of the Greenland ice sheet which are essential for describing the energy and mass of the ice sheet. Several key components of the energy balance are parameterized using satellite data and in situ measurements. The analysis will be done for a ten year time period in order to get statistics on the seasonal and interannual variations of the surface processes and the climatology. Our goal is to investigate to what accuracy and over what geographic areas large scale snow properties and radiative fluxes can be derived based upon a combination of available remote sensing and meterological data sets. Data analysis showed the following results: (1)cloud classification based on longwave sky radiation revealed that overcast sky occurred for 25% of the time in winter, and for 15% in spring and summer respectively (winter and summer both show the same occurrence of clear sky of approximately 26%); (2) comparison of aerodynamic profile method with eddy correlation method to derive sensible and latent heat flux showed good agreement in the diurnal cycle and the turbulent fluxes were underestimated with the aerodynamic method by 10 - 30% as compared to the in situ eddy flux method; (3) the katabatic wind shows a distinct diurnal cycle with a maximum in the morning (7-9 h solar time) and a minimum in the later afternoon (18 h solar time); (4) snow grain size was modeled with a surface energy balance model (SNTHERM) and compared with in situ measurements. Sharp decreases in the modeled snow grain size, caused by accumulation events such as precipitation and deposition, could be verified with observational data; (4) radiative transfer modeling of firn supports our beliefs that the observed trends in 18 and 19 GHz passive microwave brightness temperatures are attributable to accumulation rate changes (modeling also indicates the above relationship is detectable because of the presence of depth hoar; (5) snow melt can be detected by a distinct signal in the passive microwave cross-polarized gradient ratio (19h-37v)/(19h+37v) and has been used for wet/dry snow classification; (6) top of the atmosphere (TOA) broadband albedos were derived from AVHRR visible and near infrared reflectances for the entire ice sheet from May 1990 - June 1991, and the highest albedo values are found along the southeast coast of the ice sheet which is consistent with the summer peak of precipitation due to onshore flow loaded with high water vapor content (TOA albedo values dropped to around 40% along the south-western coast during July and August due to bare ice surfaces); and (7) the net all-wave radiation balance at the top of the atmosphere is negative over the entire ice sheet except for the summer months - June-July-August (in June, the net radiation balance is slightly positive over the dry snow areas--15 W/m2).

Steffen, K.↗

Additive Manufacturing of Thermal Energy Storage Composites with Microencapsulated Phase Change Materials Supported in a Multipolymer Matrix

Additive manufacturing (AM) techniques to directly integrate phase change materials (PCMs) are of interest for efficient thermal energy storage (TES) architectures. Complex, high surface-to-volume ratio composites embedded with PCM can improve thermal management with reduced material waste for customizable device fabrication. Reducing feature sizes of TES-integrated heat exchangers using AM can increase heat transfer without thermal conductivity enhancement. Here, composite AM materials containing 60 wt% microencapsulated phase change materials (MEPCM) are fabricated using off-the-shelf printers at common speeds and resolutions. High MEPCM loading in filaments is achieved with powder extrusion using two polymers, thermoplastic-polyurethane (TPU) and polycaprolactone (PCL), that mediate flexibility and rigidity for effective extrusion and printing without filament fracture or buckling. Furthermore, with PCL and TPU at 20 wt% each and 60 wt% MEPCM (P 20 T 20 M 60 ), smooth, form-stable filaments are consistently printed. Powder-based extrusion displays negligible damaging effects on the MEPCM. Printed P 20 T 20 M 60 demonstrates 105 J/g of energy storage with no degradation through 250 thermal cycles, within 5% of the theoretical storage enthalpy. Combining PCL/TPU shows good interfacial adhesion between print layers and produces high surface area objects, like 15% gyroids, and dense, 100% infilled pucks. Prints are also scalable to a 900 cm 3 honeycomb heat exchanger with an estimated 9 Wh energy storage.

25 ENERGY STORAGE↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗