Search NASA⌕ Search

SEARCH · Search NASA

Results for “light metals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Parameterization of Solid Metal-Liquid Metal Partitioning of Siderophile Elements

The composition of a metallic liquid can significantly affect the partitioning behavior of elements. For example, some experimental solid metal-liquid metal partition coefficients have been shown to increase by three orders of magnitude with increasing S-content of the metallic liquid. Along with S, the presence of other light elements, such as P and C, has also been demonstrated to affect trace element partitioning behavior. Understanding the effects of metallic composition on partitioning behavior is important for modeling the crystallization of magmatic iron meteorites and the chemical effects of planetary differentiation. It is thus useful to have a mathematical expression that parameterizes the partition coefficient as a function of the composition of the metal. Here we present a revised parameterization method, which builds on the theory of the current parameterization of Jones and Malvin and which better handles partitioning in multi-light-element systems.

Chabot, N. L.↗

Room-temperature bonding of thin plastic sheets

Thin sheets of plastic are bonded together, without heat, by depositing metal films on plastic and applying light pressure. Films are pressed together at room temperature, technique which makes it possible to join organic material without high temperatures necessary for conventional adhesive bonding.

Frazer, R. E.↗

Comet flyby sample return experiment

Dust from several comets can be returned to earth with minimum propulsion effort after a high-speed encounter. The collection concept involves the capture of individual dust particles by condensation in a cell after vaporization by a thin diaphragm. This collection concept has been validated in laboratory tests. To compensate for the slower laboratory velocities in a two-stage light-gas gun, higher-density metals (Zn and Cd) have been used for particles and diaphragms to simulate hypervelocity vaporization. Teflon has proved to be a suitable material for the collection cell; more than 50 percent of the vaporized projectile material has been recovered by chemical etching from such cells. Hypervelocity-impact parameters (such as diaphragm-to-projectile ratio, hole size, and plume angles) determined by tests permit the modification of existing analytical models. These new findings are necessary for flyby cometary experiments.

Tsou, P.↗

Black Carbon Measurements in SOLVE-2

Droplet Measurement Technologies (DMT), under funding from NASA s Radiation Sciences Program, participated in the SOLVE II field campaign with measurements of light absorbing particles (black carbon and metals). These measurements were made with the Single Particle Soot Photometer (SP-2) on the NASA DC-8. The SP-2 is a new measurement technique that was developed under the SBIR program with funding from the Office of Naval Research. The original instrument suite for the DC-8 did not include the SP-2 and its addition and operation during SOLVE II was intended solely as a means to test its functionality and prepare it for future flight operations. For this reason it required several flights in the early stages of the project to tune its operation and fix some problems that arose. During the flights of January 26, 29, and 30, and February 2, 4 and 6, however, it worked as designed and acquired credible data.

Kok, Gregory L.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted simultaneously with native fluorescence spectroscopy to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Compact Autonomous Hemispheric Vision System

Solar System Exploration camera implementations to date have involved either single cameras with wide field-of-view (FOV) and consequently coarser spatial resolution, cameras on a movable mast, or single cameras necessitating rotation of the host vehicle to afford visibility outside a relatively narrow FOV. These cameras require detailed commanding from the ground or separate onboard computers to operate properly, and are incapable of making decisions based on image content that control pointing and downlink strategy. For color, a filter wheel having selectable positions was often added, which added moving parts, size, mass, power, and reduced reliability. A system was developed based on a general-purpose miniature visible-light camera using advanced CMOS (complementary metal oxide semiconductor) imager technology. The baseline camera has a 92 FOV and six cameras are arranged in an angled-up carousel fashion, with FOV overlaps such that the system has a 360 FOV (azimuth). A seventh camera, also with a FOV of 92 , is installed normal to the plane of the other 6 cameras giving the system a > 90 FOV in elevation and completing the hemispheric vision system. A central unit houses the common electronics box (CEB) controlling the system (power conversion, data processing, memory, and control software). Stereo is achieved by adding a second system on a baseline, and color is achieved by stacking two more systems (for a total of three, each system equipped with its own filter.) Two connectors on the bottom of the CEB provide a connection to a carrier (rover, spacecraft, balloon, etc.) for telemetry, commands, and power. This system has no moving parts. The system's onboard software (SW) supports autonomous operations such as pattern recognition and tracking.

Pingree, Paula J.↗

Spectroscopic chemical analysis methods and apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. Chemical analysis instruments employed in some embodiments include capillary and gel plane electrophoresis, capillary electrochromatography, high performance liquid chromatography, flow cytometry, flow cells for liquids and aerosols, and surface detection instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

The Host Galaxies of Type Ia Supernovae Discovered by the Palomar Transient Factory

We present spectroscopic observations of the host galaxies of 82 low-redshift type Ia supernovae (SNe Ia) discovered by the Palomar Transient Factory (PTF). We determine star-formation rates, gas-phase stellar metallicities, and stellar masses and ages of these objects. As expected, strong correlations between the SN Ia light-curve width (stretch) and the host age mass metallicity are found: fainter, faster-declining events tend to be hosted by older massive metal-rich galaxies. There is some evidence that redder SNe Ia explode in higher metallicity galaxies, but we found no relation between the SN colour and host galaxy extinction based on the Balmer decrement, suggesting that the colour variation of these SNe does not primarily arise from this source. SNe Ia in higher-mass metallicity galaxies also appear brighter after stretch colour corrections than their counterparts in lower mass hosts, and the stronger correlation is with gas-phase metallicity suggesting this may be the more important variable. We also compared the host stellar mass distribution to that in galaxy targeted SN surveys and the high-redshift untargeted Supernova Legacy Survey (SNLS). SNLS has many more low mass galaxies, while the targeted searches have fewer. This can be explained by an evolution in the galaxy stellar mass function, coupled with a SN delay-time distribution proportional to t1. Finally, we found no significant difference in the mass--metallicity relation of our SN Ia hosts compared to field galaxies, suggesting any metallicity effect on the SN Ia rate is small.

host↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Vibration Characteristics Determined for Stainless Steel Sandwich Panels With a Metal Foam Core for Lightweight Fan Blade Design

The goal of this project at the NASA Glenn Research Center is to provide fan materials that are safer, weigh less, and cost less than the currently used titanium alloy or polymer matrix composite fans. The proposed material system is a sandwich fan construction made up of thin solid face sheets and a lightweight metal foam core. The stiffness of the sandwich structure is increased by separating the two face sheets by the foam layer. The resulting structure has a high stiffness and lighter weight in comparison to the solid facesheet material alone. The face sheets carry the applied in-plane and bending loads (ref. 1). The metal foam core must resist the transverse shear and transverse normal loads, as well as keep the facings supported and working as a single unit. Metal foams have ranges of mechanical properties, such as light weight, impact resistance, and vibration suppression (ref. 2), which makes them more suitable for use in lightweight fan structures. Metal foams have been available for decades (refs. 3 and 4), but the difficulties in the original processes and high costs have prevented their widespread use. However, advances in production techniques and cost reduction have created a new interest in this class of materials (ref. 5). The material chosen for the face sheet and the metal foam for this study was the aerospace-grade stainless steel 17-4PH. This steel was chosen because of its attractive mechanical properties and the ease with which it can be made through the powder metallurgy process (ref. 6). The advantages of a metal foam core, in comparison to a typical honeycomb core, are material isotropy and the ease of forming complex geometries, such as fan blades. A section of a 17-4PH sandwich structure is shown in the following photograph. Part of process of designing any blade is to determine the natural frequencies of the particular blade shape. A designer needs to predict the resonance frequencies of a new blade design to properly identify a useful operating range. Operating a blade at or near the resonance frequencies leads to high-cycle fatigue, which ultimately limits the blade's durability and life. So the aim of this study is to determine the variation of the resonance frequencies for an idealized sandwich blade as a function of its face-sheet thickness, core thickness, and foam density. The finite element method is used to determine the natural frequencies for an idealized rectangular sandwich blade. The proven Lanczos method (ref. 7) is used in the study to extract the natural frequency.

Ghosn, Louis J.↗

Demonstration of Advanced C/SiC Cooled Ramp

Under a NASA contract, SPS is evaluating its C/SiC to metal brazing technique for the development of light, composite, actively cooled panels. The program first consisted of defining a system applicable to the X-33 nozzle ramp. SPS then performed evaluation tests for tube, composite, and braze material selection, and for the adaptation of braze process parameters to the parts geometry. SPS is presently manufacturing a 250x60 millimeter squared specimen, including 10 metallic tubes, which will be cycled in the NASA/GRC-CELL-22 test bed under engine representative conditions.

Bouquet, Clement↗

A new analysis of beam waveguide antennas considering the presence of the metal enclosure

Large beam waveguide (BWG) type ground station antennas are generally designed using analysis which ignores the presence of the metallic tube enclosing the beam waveguide mirrors. The common analysis approaches are physical optics and Gaussian mode analyses. The weakness of these analyses is that they do not shed any light with regards to the effect of the metal tube. In this paper, the first known BWG analysis which considers the presence of the metal tube is presented. Numerical results of a two-mirror system using the new analysis are compared with experiments which have verified the new analysis.

Cha, Alan G.↗

The spectral effects of subsolidus reduction of olivine and pyroxene

The surfaces of atmosphereless bodies are subjected to a variety of chemical, thermal, accretionary, and shock processes related to their regolith environment. These processes are responsible for a number of alterations that occur in regoliths. Alterations include particle size commutation, implantation of solar wind gases, formation of agglutinates, spectral darkening, and, in the lunar case, the development of the very strong red continuum slope in the visible and near infrared spectra. A great deal of work has pointed to the role of agglutinates as the principal agent for darkening and reddening the lunar soil. The measures of regolith maturity are strongly linked to the accumulation of agglutinates. Recent work has suggested that the finest fractions of agglutinitic glass are major source of the spectral red slope. In particular, the red slope is most strongly associated with the agglutinitic glasses that are rich in blebs of sub-micron sized metal particles. It is thought that these metal particles, because of their size and scattering efficiently relative to the wavelength of light, are responsible for the red continuum slope. This fine fraction of metal particles is produced primarily by reduction of Fe(+2) from silicates. One mechanism for the reduction process is the reaction of solar implanted wind protons with the regolith soil during impact events. In this case the presence of hydrogen creates a reducing environment and the thermal pulse from the impact greatly speeds the reaction kinetics. To explore other reducing and thermal environments a series of experiments were done using samples in evacuated capsules buffered by Tantalum and heated to subsolidus temperatures.

Britt, D. T.↗

Fast, Large Area, Wide Band GAP UV Photodetector for Cherenkov Light Detection

A solid-state radiation detector includes a pattern of conductive metal on a zinc oxide substrate. The pattern provides an arrangement of interdigitated electrode fingers. The wide band gap substrate is sensitive to UV light, which can cause a conductivity change in the substrate. The electrode fingers are configured to sense a difference in substrate conductivity resulting from UV light. The detector has a fast response time, which enables it to detect Cherenkov light. The compact detector provides savings on size, weight, and required power. Thus, the solid-state detector can be used to replace photomultiplier tubes in Cherenkov detectors. The features of the novel detector allow for an improved system to detect and monitor UV radiation, especially during deep space missions.

Wrbanek, John D.↗

Pallasites - Metal composition, classification and relationships with iron meteorites

A comparative study was conducted of the metal composition of 34 pallasites in order to shed further light on the origin of these meteorites. Concentrations of Au, As, Co, Ga, Ge, Ir, Ni, and W in pallasitic metal were determined. Most pallasites are found to have similar compositions indicating a close genetic relationship, and are designated as main group. The Eagle Station Trio is unrelated to the main group as indicated by higher Ni, Ge, and Ir and lower As, Au, and Ga contents in the metal, and olivine richer in Fe and Sc and poorer in Mg and Mn. The trio of Springwater, Rawlinna and Phillips County have metal compositions appropriate to high-Ni main group members, but their fayalite contents suggest they are not closely related to it. Pavlodar and Glorieta Mountain appear to be unique pallasites, and Brenham an anomalous main group member. Krasnoyarsk is classified as a main group member. Main group pallasites have metal compositions which overlap those of IIIAB iron meteorites on a Ga-Ge plot, and they have similar Au, As, Cr, Ir, Ni and W contents to high-Ni IIIAB irons.

Scott, E. R. D.↗

Process Development and Testing for Lunar Habitats

Non-metallic solutions for Lunar bases are appealing due to their light weight and ability to block many forms of radiation. Composite materials made from different combinations of these non-metallic materials enable effective mating of dissimilar materials for strong structures such as pressurized habitats. Inserting and manufacturing composite structural materials on the Moon presents several challenges, however: the oxygen levels inside pressurized habitats will be relatively high, radiation that is blocked causes damage and the lack of atmosphere results in a high-magnitude negative pressure environment. In the past two years, the Materials and Processes Lab (EM01) invested in two internal research and development (IRAD) proposals for testing and procurement of composite materials. One proposal endeavors to determine flammability and radiation damage of various composite materials with a focus on carbon fiber and ultra-high molecular weight polyethylene (UHWMPE). The other proposal enables procurement of chopped fiber spray equipment materials which will be used to develop a novel technique for chopped UHMWPE fiber layup, similar to the chopped fiberglass layups used for making large structures such a boat hulls and hot tubs.

Composite↗