Search NASA⌕ Search

SEARCH · Search NASA

Results for “linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]↗

Extraction scheme for future CEBAF FFA based energy upgrade

Jefferson lab is considering an energy increase from current 12 GeV to 22 GeV for its CEBAF accelerator. This will be accomplished by recirculating 5-6 additional turns through two parallel CEBAF LINACs using an FFA arc at each end of the racetrack. The total recirculation turns would be 10 times, the first four turns use present conventional arcs to make the 180-degree bends from one LINAC to the other. However, the last 5-6 turns will all share a single beam line inside two FFA arcs. This reduces the footprint and the cost of the project significantly. On the other hand, having the trajectories of last 5-6 recirculating beams close to each other makes it challenging to extract beams from different passes with different energies. In this paper we will explain our present extraction system for 12 GeV, our challenges and limitations, and a possible extraction solution for the 22 GeV upgrade with the goal of extracting beam at different turns/energies to different experimental halls.

Kazimi, Reza↗

Compensating for Amplifier Non-Linearity in a SEL Controller

The SEL architecture used commonly in CW superconducting linacs is a positive feedback system that requires determining the correct limits for the operating conditions to ensure stable operation. These limits are determined from the results of the amplifier calibration which characterizes the dac drive(forward power) against the cavity field. When the amplifier non-linearity precludes a simple linear fit for this characteristic, its modification to account for the amplifiers non-linearity is essential to operate the system in the SEL architecture. This process is described with test data from a 32kW SSA for the PIP-II linac.

Sankar Raman, Shrividhyaa [Fermilab]↗

Time-of-Flight Energy Measurements With BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed at Fermilab. The case when the flight time between BPMs is longer than the period of BPM frequency is considered in more detail. When absolute BPM phase calibration is not available, the BPM phase information can be used to track deviations of the beam energy from the de-sired value. Such energy deviation parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander V. [Fermilab] (ORCID:00000001↗

Estimation of the Required Dipole Corrector Magnetic Field for PIP-II Injection Based on Beam Studies

The Fermilab Booster will accept a 600 µs beam pulse from the new superconducting Linac for PIP-II operations. The Booster is a rapid-cycling synchrotron that uses a resonant magnet circuit ramping at 15 Hz. For PIP-II, the cycle rate will increase to 20 Hz, and the injection pulse length will expand from 40 µs to 600 µs due to the lower output current from the new Linac. Because the Booste main bending field follows a sinusoidal waveform, the magnetic field is not constant during the extended injection window. The longer pulse length and higher repetition rate modify the beam orbit and can lead to increased beam losses. The Booster contains 48 dipole-corrector packages distributed across its 24 periods. Each package includes horizontal and vertical dipoles, quadrupole, sextupole, skew-quadrupole, and skew-sextupole elements. By driving the dipole correctors with an appropriately shaped sinusoidal waveform during injection, we can compensate the changing main field and create an effectively flat bending field—referred to as flat injection. Over the past several years, machine studies have been performed to characterize the required correction fields and to determine the corresponding power-supply specifications needed for PIP-II operation. In this presentation, we will summarize the study results and discuss the estimated magnetic field requirements and power supply parameters for achieving flat injection in the Booster.

Seiya, K. [Fermilab] (ORCID:0000000250576943)↗

Accelerator Upgrades Required for Beam Operation at Fermilab in the PIP-II/DUNE Era

The Proton Improvement Plan - II (PIP-II) injector linac is an 800 MeV superconducting H⁻ linac, christened Linac2, that will replace the existing 400 MeV injector to the accelerator complex at Fermilab. The higher energy, intensity and repetition rate require various upgrades to the existing accelerator complex consisting of the Booster, the Recycler Ring and the Main Injector, in order to be able to accept and accelerate beam from PIP-II. In this paper we discuss various upgrades that are required and steps being taken to implement them.

Krishnagopal, S. [Fermilab]↗

Hofmann Stability Charts Revisited for PIP-II: From Classical Theory to Assumption-Free and ML-Driven Maps

The Hofmann stability chart remains a standard for visualizing parametric resonances in space-charge–dominated linacs, but its use typically relies on non-oscillatory Vlasov dispersion relations with simplifying assumptions (continuous focusing, KV phase space, linear optics, limited transverse–longitudinal coupling). We revisit the chart for the PIP-II linac along three tracks. (1) We reproduce the conventional maps in the (νz/νx, νx/ν0x) plane for relevant εz/εx, providing a validated reference. (2) We remove key assumptions by deriving stability surfaces directly from multi-particle tracking with realistic lattice discreteness, RF defocusing, solenoid/quad optics, and bunched-beam dynamics; local tunes and early-time growth rates are estimated from envelope oscillations and projected to the same coordinates. These assumption-reduced maps recover the canonical stopbands while revealing shifts and broadenings driven by tune modulation, non-KV distributions, and transverse–longitudinal coupling at PIP-II intensities. (3) We train a compact machine-learning surrogate that emulates the growth surface from zero-current optics, tune depression, emittance ratio, bunching factor, and selected lattice descriptors, enabling rapid scans and online working-point selection. We compare the three representations on representative PIP-II sections and discuss implications for commissioning guard bands, resonance avoidance, and routine operations.

Pathak, Abhishek [Fermilab] (ORCID:000000021704208↗

Measurements of the UV and VUV transmission of optical materials during high energy electron irradiation

An experimental program was conducted in which the optical transmission of several transparent materials was measured during high energy electron irradiation. These experiments were conducted using the Dynamitron electron accelerator as a continuous source of 1.5 MeV electrons and the LINAC electron accelerator as a pulsed source of 5-7 MeV electrons. The experimental program consisted of three major portions. The first portion, the optical transmission of fused silica, BeO, MgF2, and LiF was measured at vacuum ultraviolet wavelengths in the range 1550-2000 A during ambient temperature, 1.5 MeV electron irradiation at ionizing dose rates to 0.5 Mrad/sec. In the second portion of the program, the optical transmission of fused silica and BeO was measured in the range 2000-3000 A during high dose rate, elevated temperature 1.5 MeV electron irradiation. In particular, accurate measurements of the optical transmission were made at ionizing dose rates as high as 10 Mrad/sec. In the final portion of the program, the optical transmission of fused silica and BeO was measured in the wavelength range 2000-3000 A during pulsed 5 and 7 MeV electron irradiation from the LINAC accelerator. The maximum time averaged ionizing dose rate was limited to 0.75 Mrad/sec due to accelerator limitations.

Palma, G. E.↗

Adaptation of the Fermilab proton source to support new muon facilities

The PIP-II proton accelerator will provide the intensity sufficient to power a new generation of high energy facilities at Fermilab. Extension of that linac to higher energy with following acceleration and bunching rings could provide the intensity needed to feed a muon production target for a high-energy $\mu^{+} - \mu^{-}$ collider. Scenarios using a rapid-cycling synchrotron or an $\sim$8 GeV Linac are presented and discussed. Some near-term opportunities at Fermilab for muon collider R\&D are introduced.

43 PARTICLE ACCELERATORS↗

Compensating for Amplifier Non-Linearity in a SEL Controller

The Self-Excited Loop (SEL) architecture, used in some continuous-wave (CW) superconducting linacs, relies on a positive feedback mechanism that requires carefully defined operating limits to ensure stable operation. These limits are typically derived from amplifier calibration, which characterizes the relationship between forward power and DAC drive. However, amplifier non-linearity often prevents a simple linear fit of this characteristic, introducing errors that can compromise stability. To address this, we present a modified calibration procedure that incorporates amplifier non-linearity into the SEL framework. The approach is validated with test data from a 32 kW solid-state amplifier (SSA) and a cavity emulator developed for the Fermilab PIP-II linac.

Raman, S. [Fermilab] (ORCID:0009000735937206)↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign, an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real-time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB650 CM.

Yoon, S. [Fermilab]↗

Accelerator Upgrades Required for Beam Operation at Fermilab in the PIP-II/DUNE Era

The Proton Improvement Plan - II (PIP-II) injector linac is an 800 MeV superconducting H$^-$ linac, christened Linac2, that will replace the existing 400 MeV injector to the accelerator complex at Fermilab. The higher energy, intensity and repetition rate require various upgrades to the existing accelerator complex consisting of the Booster, the Recycler Ring and the Main Injector, in order to be able to accept and accelerate beam from PIP-II. In this paper we discuss various upgrades that are required and steps being taken to implement them.

Krishnagopal, S. [Fermilab]↗

Stability of the fcc phase in shocked nickel up to 332 GPa

Despite making up 5-20 wt.% of Earth’s predominantly iron core, the melting properties of elemental nickel at core conditions remain poorly understood, due largely to a dearth of experimental data. We present here an in situ X-ray diffraction study performed on laser shock-compressed samples of bulk nickel, reaching pressures up to ~ 500 GPa. Hugoniot states of nickel were targeted using a flat-top laser drive, with in situ X-ray diffraction data collected using the Linac Coherent Light Source. Rietveld methods were used to determine the densities of the shocked states from the measured diffraction data, while peak pressures were determined using a combination of measured particle velocities, shock transit times, hydrodynamic simulations, and laser intensity calibrations. We observed solid compressed face-centered cubic (fcc) Ni up to at least 332 ± 30 GPa along the Hugoniot—significantly higher than expected from the majority of melt lines that have been proposed for nickel. We also bracket the partial melting onset to between 377 ± 38 GPa and 486 ± 35 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗

Control of microphonics for a superconducting radio-frequency photo-injector cryomodule

A superconducting radio-frequency photo-injector cryomodule is being developed for the high-energy upgrade of the Linac Coherent Light Source (LCLS-II-HE). This effort is a collaboration between the Facility for Rare Isotope Beams at Michigan State University (MSU), Argonne National Laboratory, Helmholtz-Zentrum Dresden-Rossendorf, and SLAC National Accelerator Laboratory. The cryomodule features a 185.7 MHz superconducting quarter-wave resonator (QWR) designed to operate with an RF electric field of 30 MV/m at the photo-cathode. Mechanical vibrations must be controlled for operation with stable amplitude and phase. The first prototype cryomodule was cold-tested at MSU with a QWR, fundamental power coupler, tuner, and cathode stalk. In the cold test, we observed microphonics that made it difficult to control the RF phase at high gradient. The cryogenic circuit was identified as a likely culprit. This paper presents our studies of microphonics during the cryomodule cold test and follow-up investigations at room temperature. Our findings provided valuable feedback for modifications to the cryogenic circuit and a successful second cold test of the cryomodule.

Accelerator Physics↗

Demagnetization analysis of an 18 GHz electron cyclotron resonance ion source permanent magnet hexapole

An upgrade of ECR2 at the Argonne Tandem Linac Accelerator System is under way, focusing on increasing the intensity capabilities of the facility. ECR2 is a room temperature electron cyclotron resonance ion source, and the upgrade has strict requirements to retain radial access to the plasma chamber and keep the ion source operating without the use of superconducting magnets. The upgrade design with respect to the magnet arrangement and magnetization vectors has recently been presented [R. C. Vondrasek, J. McLain, and R. H. Scott, J. Phys.: Conf. Ser. 2743 , 012044 (2024)] using the same magnetic material as the current ECR2 hexapole. A thorough exploration of the demagnetization potential of this hexapole was carried out, and the risk of demagnetization was deemed too high, despite the magnetic performance meeting the requirements for the upgrade. Additional permanent magnet materials are considered with their respective performance evaluated. Magnet strength and demagnetization resistance are investigated and optimized with the final room temperature design demonstrating a high temperature transient demagnetization resistance and a radial magnetic field of 1.18 T at the plasma chamber wall. Finally, the simulations of this hexapole suggest that it will be sufficient to optimize intensity with a 14.5 GHz driving frequency and will allow 18 GHz operation, while keeping a high safety margin for maintaining magnet performance.

Argonne Tandem Linac Accelerator System↗

LAMP DTL Scoping Studies (Technical Report)

The present studies are based on the preliminary design efforts, and on the Scoping Studies of the “Strawman” design of LAMP front-end upgrade, referred in the text below to as “Feb.2024 Iteration”, presented in. The main accomplishment of present studies was substantial increase of the fidelity of the beam dynamics simulations in the proposed drift tube linac (DTL). The main accent was on development of the methodology for calculation of the longitudinal (synchrotron) and transverse (betatron) oscillations frequencies (phase advance per focusing period) values and providing the accelerating structure focusing lattice that has safe parameters of such oscillations to avoid unwanted emittance growth and possible beam halo formation. The resulting values of the oscillations phase advances are presented in Table 1, and in Figure 5 in the main body of the report. Special efforts were made to achieve the RF power consumption within limits of the existing RF power system and make sure that DTL fits in the existing tunnel. The LAMP scope does not suggest any additional building and/or tunnel construction. Table 1 summarizes some of these results, as well as Table 3 in the main body of the report.

43 PARTICLE ACCELERATORS↗