Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Ocular Counter-Rolling During Centrifugation and Static Tilt

Activation of the gravity sensors in the inner ear-the otoliths-generates reflexes that act to maintain posture and gaze. Ocular counter-rolling (OCR) is an example of such a reflex. When the head is tilted to the side, the eyes rotate around the line of sight in the opposite direction (i.e., counter-rolling). While turning comers, undergoing centrifugation, or making side-to-side tilting head movements, the OCR reflex orients the eyes towards the sum of the accelerations from body movements and gravity. Deconditioning of otolith-mediated reflexes following adaptation to microgravity has been proposed as the basis of many of the postural, locomotor, and gaze control problems experienced by returning astronauts. Evidence suggests that OCR is reduced postflight in about 75% of astronauts tested; but the data are sparse, primarily due to difficulties in recording rotational eye movements. During the Neurolab mission, a short-arm human centrifuge was flown that generated sustained sideways accelerations of 0.5-G and one-G to the head and upper body. This produces OCR; and so for the first time, the responses to sustained centrifugation could be studied without the influence of Earth's gravity on the results. This allowed us to determine the relative importance of sideways and vertical acceleration in the generation of OCR. This also provided the first test of the effects of exposure to artificial gravity in space on postflight otolith-ocular reflexes. There was little difference between the responses to centrifugation in microgravity and on Earth. In both conditions, the induced OCR was roughly proportional to the applied acceleration, with the OCR magnitude during 0.5-G centrifugation approximately 60% of that generated during one-G centrifugation. The overall mean OCR from the four payload crewmembers in response to one-G of sideways acceleration was 5.7 plus or minus 1.1 degree (mean and SD) on Earth. Inflight one-G centrifugation generated 5.7 plus or minus 1.1 degree of OCR, which was a small but significant decrease in OCR magnitude. The postflight OCR was 5.9 plus or minus 1.4 degree, which was not significantly different from preflight values. During both 0.5-G and one-G centrifugation in microgravity, where the head vertical gravitational component was absent, the OCR magnitude was not significantly different from that produced by an equivalent acceleration during static tilt on Earth. This suggests that the larger OCR magnitude observed during centrifugation on Earth was due to the larger body vertical linear acceleration component, which may have activated either the otoliths or the body tilt receptors. In contrast to previous studies, there was no decrease in OCR gain postflight. Our findings raise the possibility that inflight exposure to artificial gravity, in the form of intermittent one-G and 0.5-G centripetal acceleration, may have been a countermeasure to deconditioning of otolith-based orientation reflexes.

Cohen, Bernard↗

Vertical Axis Rotational Motion Cues in Hovering Flight Simulation

A previous study that examined how yaw motion affected a pilot's ability to perform realistic hovering flight tasks indicated that any amount of pure yaw motion had little-to-no effect on pilot performance or opinion. In that experiment, pilots were located at the vehicle's center of rotation; thus lateral or longitudinal accelerations were absent. The purpose of the new study described here was to investigate further these unanticipated results for additional flight tasks, but with the introduction of linear accelerations associated with yaw rotations when the pilot is not at the center of rotation. The question of whether a yaw motion degree-of-freedom is necessary or not is important to government regulators who specify what simulator motions are necessary according to prescribed levels of simulator sophistication. Currently, specifies two levels of motion sophistication for flight simulators: full 6-degree-of-freedom and 3-degree-of-freedom. For the less sophisticated simulator, the assumed three degrees of freedom are pitch, roll, and heave. If other degrees of freedom are selected, which are different f rom these three, they must be qualified on a case-by-case basis. Picking the assumed three axes is reasonable and based upon experience, but little empirical data are available to support the selection of critical axes. Thus, the research described here is aimed at answering this question. The yaw and lateral degrees of freedom were selected to be examined first, and maneuvers were defined to uncouple these motions from changes in the gravity vector with respect to the pilot. This approach simplifies the problem to be examined. For this experiment, the NASA Ames Vertical Motion Simulator was used in a comprehensive investigation. The math model was an AH-64 Apache in hover, which was identified from flight test data and had previously been validated by several AH-64 pilots. The pilot's head was located 4.5 ft in front of the vehicle center of gravity, which is representative of the AH-64 pilot location. Six test pilots flew three tasks that were specifically designed to represent a broad class of situations in which both lateral and yaw motion cues may be useful. For the first task, the pilot controlled only the yaw axis and was required to rapidly acquire a North heading from 15 deg yaw offsets to either the East or West. This task allowed for full, or 1:1, motion to be used in all axes (yaw, lateral, and longitudinal). The second task was a 10 sec., 180 deg. pedal turn over a runway, but with the pilot only controlling the yaw degree-of-freedom. The position of the vehicle's center-of-mass remained fixed. This maneuver was taken from a current U.S. Army rotary wing design standard5 and is representative of a maneuver performed for acceptance of military helicopters; however, it does not allow for full 1:1 motion, since the simulator cab cannot rotate 180 deg. The third task required the pilot to perform a rapid 9 ft climb at a constant heading. This task was challenging, because rapid collective lever movement in the unaugmented AH64 results in a substantial yawing moment (due to engine torque) that must be countered by the pilot. This task also had full motion in all axes, but, in this case, the pilot had two axes to control simultaneously, rather than one as in the previous tasks. Four motion configurations were examined for each task: full motion (except for the 180 deg turn, for which the motion system was configured to provide as much motion as possible), full linear with no yaw motion, full yaw with no linear motion, and no motion. Each configuration was flown four times in a randomized test matrix, and the pilots were not informed of the configuration given. Vehicle state data were recorded for objective performance comparisons, and pilots provided subjective comments and ratings. As part of the pilots' evaluation, they were asked to rate the compensation required, the overall fidelity of the motion as compared to real flight, and whether motion was detected or not in each of the six degrees of freedom. In addition, the pilots provided a numerical level-of confidence rating, between 1 and 7, corresponding to how sure they were whether or not motion was present in each degree-of-freedom. The latter rating allow classical signal detection analysis to be performed.

Schroeder, Jeffrey A.↗

Accelerated complete-linearization method for calculating NLTE model stellar atmospheres

Two approaches to accelerating the method of complete linearization for calculating NLTE model stellar atmospheres are suggested. The first one, the so-called Kantorovich variant of the Newton-Raphson method, consists of keeping the Jacobi matrix of the system fixed, which allows us to calculate the costly matrix inversions only a few times and then keep them fixed during the subsequent computations. The second method is an application of the Ng acceleration. Both methods are extremely easy to implement with any model atmosphere code based on complete linearization. It is demonstrated that both methods, and especially their combination, yield a rapidly and globally convergent algorithm, which takes 2 to 5 times less computer time, depending on the model at hand and the required accuracy, than the ordinary complete linearization. Generally, the time gain is more significant for more complicated models. The methods were tested for a broad range of atmospheric parameters, and in all cases they exhibited similar behavior. Ng acceleration applied on the Kantorovich variant thus offers a significant improvement of the standard complete-linearization method, and may now be used for calculating relatively involved NLTE model stellar atmospheres.

Hubeny, I.↗

Centrifuge Study of Pilot Tolerance to Acceleration and the Effects of Acceleration on Pilot Performance

A research program the general objective of which was to measure the effects of various sustained accelerations on the control performance of pilots, was carried out on the Aviation Medical Acceleration Laboratory centrifuge, U.S. Naval Air Development Center, Johnsville, PA. The experimental setup consisted of a flight simulator with the centrifuge in the control loop. The pilot performed his control tasks while being subjected to acceleration fields such as might be encountered by a forward-facing pilot flying an atmosphere entry vehicle. The study was divided into three phases. In one phase of the program, the pilots were subjected to a variety of sustained linear acceleration forces while controlling vehicles with several different sets of longitudinal dynamics. Here, a randomly moving target was displayed to the pilot on a cathode-ray tube. For each combination of acceleration field and vehicle dynamics, pilot tracking accuracy was measured and pilot opinion of the stability and control characteristics was recorded. Thus, information was obtained on the combined effects of complexity of control task and magnitude and direction of acceleration forces on pilot performance. These tests showed that the pilot's tracking performance deteriorated markedly at accelerations greater than about 4g when controlling a lightly damped vehicle. The tentative conclusion was also reached that regardless of the airframe dynamics involved, the pilot feels that in order to have the same level of control over the vehicle, an increase in the vehicle dynamic stability was required with increases in the magnitudes of the acceleration impressed upon the pilot. In another phase, boundaries of human tolerance of acceleration were established for acceleration fields such as might be encountered by a pilot flying an orbital vehicle. A special pilot restraint system was developed to increase human tolerance to longitudinal decelerations. The results of the tests showed that human tolerance of longitudinal deceleration forces was considerably improved through use of the special restraint system.

Creer, Brent Y.↗

Vestibular compensation and orientation during locomotion

Body, head, and eye movements were studied in three dimensions while walking and turning to determine the role of the vestibular system in directing gaze and maintaining spatial orientation. The body, head, and eyes were represented as three-dimensional coordinate frames, and the movement of these frames was related to a trajectory frame that described the motion of the body on a terrestrial plane. The axis-angle of the body, head, and eye rotation were then compared to the axis-angle of the rotation of the gravitoinertial acceleration (GIA). We inferred the role of the vestibular system during locomotion and the contributions of the VCR and VOR by examining the interrelationship between these coordinate frames. Straight walking induced head and eye rotations in a compensatory manner to the linear accelerations, maintaining head pointing and gaze along the direction of forward motion. Turning generated a combination of compensation and orientation responses. The head leads and steers the turn while the eyes compensate to maintain stable horizontal gaze in space. Saccades shift horizontal gaze as the turn is executed. The head pitches, as during straight walking. It also rolls so that the head tends to align with the orientation of the GIA. Head orientation changes anticipate orientation changes of the GIA. Eye orientation follows the changes in GIA orientation so that the net orientation gaze is closer to the orientation of the GIA. The study indicates that the vestibular system utilizes compensatory and orienting mechanisms to stabilize spatial orientation and gaze during walking and turning.

Non-NASA Center↗

Motion sickness in the squirrel monkey

In this study of susceptibility to motion sickness the specific aims were to examine the effects of combined vertical rotation and horizontal acceleration, phenotype, sex, visual cues, morning and afternoon testing, and repeated test exposures on incidence, frequency, and latency of emetic responses. The highest emetic incidence of 89% with an emetic frequency of 2.0 during 60 min and a latency of 19 min from onset of testing occurred at 25 rpm and 0.5 Hz linear acceleration. Since the emetic responses were quite similar to man in eliciting motion stimuli it was concluded that the squirrel monkey represents a very suitable primate model for studies of motion and space sickness.

Ordy, J. M.↗

Ground-Based Reduced-Gravity Facilities

For the past 30 years, NASA Lewis Research Center's ground-based reduced-gravity facilities have supported numerous investigations for several research disciplines. Lewis' two drop towers and its DC-9 aircraft have provided a low-gravity environment (gravitational levels that range from 1 percent of Earth's gravitational acceleration to onemillionth of that measured at the Earth's surface) for brief periods of time. "Zero gravity," the weightless condition also known as microgravity, can be produced in these facilities by creating a free-fall or semi-free-fall condition where the force of gravity on an experiment is offset by its linear acceleration during a "fall" (a drop in a tower or a parabolic maneuver by an aircraft). The low-gravity environment obtained "on the ground" in NASA facilities is the same as that of a spacecraft in orbit around the Earth.

Lekan, Jack F.↗

Conceptual Design of an Experiment to Study Dust Destruction by Astrophysical Shock Waves

A novel laboratory experimental design is described that will investigate the processing of dust grains in astrophysical shocks. Dust is a ubiquitous ingredient in the interstellar medium (ISM) of galaxies; however, its evolutionary cycle is still poorly understood. Especially shrouded in mystery is the efficiency of grain destruction by astrophysical shocks generated by expanding supernova remnants. While the evolution of these remnants is fairly well understood, the grain destruction efficiency in these shocks is largely unknown. The experiments described herein will fill this knowledge gap by studying the dust destruction efficiencies for shock velocities in the range of approximately 10-30 kilometers per second (microns per nanosecond), at which most of the grain destruction and processing in the ISM takes place. The experiments focus on the study of grain-grain collisions by accelerating small (1 millimeter) dust particles into a large (approximately 5-10 millimeter diameter) population; this simulates the astrophysical system well in that the more numerous, small grains impact and collide with the large population. Facilities that combine the versatility of high-power optical lasers with the diagnostic capabilities of X-ray free-electron lasers, e.g., the Matter in Extreme Conditions instrument at the SLAC (originally named Stanford Linear Accelerator Center) National Accelerator Laboratory, provide an ideal laboratory environment to create and diagnose dust destruction by astrophysically relevant shocks at the micron scale.

Manuel, M. J.-E.↗

Context-Specific Adaptation of Gravity-Dependent Vestibular Reflex Responses

Stabilization of the eyes and head during body movements is important for maintaining balance and keeping the images of objects stationary on our retinas. Impairment of this ability can lead to disorientation and reduced performance in sensorimotor tasks such as piloting of spacecraft. In the absence of a normal earth gravity field, the dynamics of head stabilization, and the interpretation of vestibular signals that sense gravity and linear acceleration, are subject to change. Transitions between different gravitoinertial force environments - as during different phases of space flight - provide an extreme test of the adaptive mechanisms that maintain these reflexive abilities. It is vitally important to determine human adaptive capabilities in such a circumstance, so that we can know to what extent the sensorimotor skills acquired in one gravity environment will transfer to others. Our work lays the foundation for understanding these capabilities, and for determining how we can aid the processes of adaptation and readaptation. An integrated set of experiments addresses this issue. We use the general approach of adapting some type of reflexive eye movement (saccades, the angular vestibulo-ocular reflex (AVOR), the linear vestibulo-ocular reflex (LVOR)), or the vestibulo-collic reflex (VCR), to a particular change in gain or phase in one condition of gravitoiner-tial force, and adapting to a different gain or phase (or asking for no change) in a second gravitoinertial force condition, and then seeing if the gravitoinertial force itself - the context cue - can recall the previously learned adapted responses. The majority of the experiments in the laboratory use the direction of vertical gaze or the direction of gravity (head tilt) as the context cue. This allows us to study context-specificity in a ground-based setting. One set of experiments, to be performed in parabolic flight, specifically uses the magnitude of gravitoinertial force as a context cue. This is a much better analog of the situation encountered in space flight. Various experiments investigate the behavioral properties, neurophysiological basis, and anatomical substrate of context-specific learning mechanisms. We use otolith (gravity) signals as the contextual cue for switching between adapted states of the saccadic system, the angular and linear vestibulo-ocular reflexes, and the VCR. (By LVOR we mean the oculomotor response - horizontal, vertical, and torsional - to linear translation of the head and body.) We are studying the effect of context on adaptation of saccade gain, phase and gain of the AVOR and LVOR, on ocular counterrolling (OCR) in response to static head tilt, and on head/neck reflexes (VCR) in response to rotation in different orientations. Such research is particularly germane to potential problems of postural and oculomotor control upon exposure to different gravitational environments.

Shelhamer, Mark J.↗

Modification of Eccentric Gaze-Holding

Clear vision and accurate localization of objects in the environment are prerequisites for reliable performance of motor tasks. Space flight confronts the crewmember with a stimulus rearrangement that requires adaptation to function effectively with the new requirements of altered spatial orientation and motor coordination. Adaptation and motor learning driven by the effects of cerebellar disorders may share some of the same demands that face our astronauts. One measure of spatial localization shared by the astronauts and those suffering from cerebellar disorders that is easily quantified, and for which a neurobiological substrate has been identified, is the control of the angle of gaze (the "line of sight"). The disturbances of gaze control that have been documented to occur in astronauts and cosmonauts, both in-flight and postflight, can be directly related to changes in the extrinsic gravitational environment and intrinsic proprioceptive mechanisms thus, lending themselves to description by simple non-linear statistical models. Because of the necessity of developing robust normal response populations and normative populations against which abnormal responses can be evaluated, the basic models can be formulated using normal, non-astronaut test subjects and subsequently extended using centrifugation techniques to alter the gravitational and proprioceptive environment of these subjects. Further tests and extensions of the models can be made by studying abnormalities of gaze control in patients with cerebellar disease. A series of investigations were conducted in which a total of 62 subjects were tested to: (1) Define eccentric gaze-holding parameters in a normative population, and (2) explore the effects of linear acceleration on gaze-holding parameters. For these studies gaze-holding was evaluated with the subjects seated upright (the normative values), rolled 45 degrees to both the left and right, or pitched back 30 and 90 degrees. In a separate study the further effects of acceleration on gaze stability was examined during centrifugation (+2 G (sub x) and +2 G (sub z) using a total of 23 subjects. In all of our investigations eccentric gaze-holding was established by having the subjects acquire an eccentric target (+/-30 degrees horizontal, +/- 15 degrees vertical) that was flashed for 750 msec in an otherwise dark room. Subjects were instructed to hold gaze on the remembered position of the flashed target for 20 sec. Immediately following the 20 sec period, subjects were cued to return to the remembered center position and to hold gaze there for an additional 20 sec. Following this 20 sec period the center target was briefly flashed and the subject made any corrective eye movement back to the true center position. Conventionally, the ability to hold eccentric gaze is estimated by fitting the natural log of centripetal eye drifts by linear regression and calculating the time constant (G) of these slow phases of "gaze-evoked nystagmus". However, because our normative subjects sometimes showed essentially no drift (tau (sub c) = m), statistical estimation and inference on the effect of target direction was performed on values of the decay constant theta = 1/(tau (sub c)) which we found was well modeled by a gamma distribution. Subjects showed substantial variance of their eye drifts, which were centrifugal in approximately 20 % of cases, and > 40% for down gaze. Using the ensuing estimated gamma distributions, we were able to conclude that rightward and leftward gaze holding were not significantly different, but that upward gaze holding was significantly worse than downward (p<0.05). We also concluded that vertical gaze holding was significantly worse than horizontal (p<0.05). In the case of left and right roll, we found that both had a similar improvement to horizontal gaze holding (p<0.05), but didn't have a significant effect on vertical gaze holding. For pitch tilts, both tilt angles significantly decreased gaze-holding ility in all directions (p<0.05). Finally, we found that hyper-g centrifugation significantly decreased gaze holding ability in the vertical plane. The main findings of this study are as follows: (1) vertical gaze-holding is less stable than horizontal, (2) gaze-holding to upward targets is less stable than to downward targets, (3) tilt affects gaze holding, and (4) hyper-g affects gaze holding. This difference between horizontal and vertical gaze-holding may be ascribed to separate components of the velocity-to-position neural integrator for eye movements, and to differences in orbital mechanics. The differences between upward and downward gaze-holding may be ascribed to an inherent vertical imbalance in the vestibular system. Because whole body tilt and hyper-g affects gaze-holding, it is implied that the otolith organs have direct connections to the neural integrator and further studies of astronaut gaze-holding are warranted. Our statistical method for representing the range of normal eccentric gaze stability can be readily applied to normals who maybe exposed to environments which may modify the central integrator and require monitoring, and to evaluate patients with gaze-evoked nystagmus by comparing to the above established normative criteria.

Reschke, M. F.↗

Otoliths developed in microgravity

Little is known about mechanisms that regulate the development of the otoliths in the gravity-sensing organs. Several reported experiments suggest that the growth of the otoliths is adjusted to produce a test mass of the appropriate weight. If this is the case, larger than normal otoliths would be expected in animals reared in reduced gravity and a reduced mass, relative to 1-g controls, would be expected in animals reared at elevated g. In gastropod mollusks, the gravity-sensing organ is the statocyst, a spherical organ whose wall is made largely of sensory receptor cells with motile cilia facing the lumen. Dense statoconia in the cyst lumen interact with cilia of receptor cells at the bottom of the cyst and action potentials in their axons carry information on direction and magnitude of gravity and linear acceleration. In the marine mollusk, Aplysia californica, larvae reared at 2 to 5-g, the volume of statoconia was reduced in a graded manner, compared to 1-g control animals. In the statocyst of the fresh-water pond snail, Biomphalaria glabrata, reared in space in the Closed Equilibrated Biological Aquatic System (CEBAS), the number and total volume of statoconia was increased approximately 50%, relative to ground-reared controls. Lychakov found the utricular otolith to be 30% larger in space-reared Xenopus, whereas we found the saccular otolith to be significantly larger in newt larvae reared in space. In cichlid fish reared on a centrifuge, the saccular otolith was smaller than in 1-g controls. Here, we demonstrate that the otoliths of late-stage embryos of the swordtail fish, Xiphophorus helleri, reared in space on STS-89 and STS-90 (Neurolab) were significantly larger than those of ground-controls reared in functionally identical hardware.

short duration↗