Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear programming”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

PSC algorithm description

An overview of the performance seeking control (PSC) algorithm and details of the important components of the algorithm are given. The onboard propulsion system models, the linear programming optimization, and engine control interface are described. The PSC algorithm receives input from various computers on the aircraft including the digital flight computer, digital engine control, and electronic inlet control. The PSC algorithm contains compact models of the propulsion system including the inlet, engine, and nozzle. The models compute propulsion system parameters, such as inlet drag and fan stall margin, which are not directly measurable in flight. The compact models also compute sensitivities of the propulsion system parameters to change in control variables. The engine model consists of a linear steady state variable model (SSVM) and a nonlinear model. The SSVM is updated with efficiency factors calculated in the engine model update logic, or Kalman filter. The efficiency factors are used to adjust the SSVM to match the actual engine. The propulsion system models are mathematically integrated to form an overall propulsion system model. The propulsion system model is then optimized using a linear programming optimization scheme. The goal of the optimization is determined from the selected PSC mode of operation. The resulting trims are used to compute a new operating point about which the optimization process is repeated. This process is continued until an overall (global) optimum is reached before applying the trims to the controllers.

Nobbs, Steven G.↗

Bi-Level Adaptive Storage Expansion Strategy for Microgrids Using Deep Reinforcement Learning

Battery energy storage (BES) is a versatile resource for the secure and economic operation of microgrids (MGs). Prevailing stochastic optimization-based approaches for BES expansion planning for MGs are computationally complicated. This work proposes a data-driven bi-level multi-period BES expansion planning framework to determine the siting, sizing, and timing of BES installations. The proposed planning framework unifies deep reinforcement learning (DRL) and linear programming, thereby decoupling the determinations for the integer and continuous decision variables in two time scales, respectively. In the upper level, a rainbow DRL agent with quantile regression is trained to provide dynamic planning policies to accommodate stochastic renewable energy resources (RESs), load, and battery price changes efficiently. Further, the lower level computes the optimal operation of MGs with frequency constraints to hedge the islanding contingency. The two levels communicate with one another by exchanging storage configuration and operating expenses in order to accomplish the shared goal of minimizing investment and operation costs. Comparative case studies on an MG are carried out to demonstrate the superiority of the proposed DRL-based solution to the mixed-integer linear programming counterpart on efficiency, scalability, and adaptability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Strategies for Hybrid Battery‐Storage Systems Design

As stationary hybrid energy‐storage systems (HESS) for power systems applications have recently drawn interest due to their enhanced performance and decreasing cost, developing systematic approaches for HESS design while considering controls is gaining traction. Herein, a method is presented to optimally design hybrid battery storage by proposing a mathematical modeling framework, formulated as a mixed integer linear programming model. The optimization is capable of handling multiple subsystems of batteries, considering their economic and technological performance. Decisions involve sizing of the batteries, optimal temporal and strategic dispatch to end uses, and energy sources for charging each battery. The applicability of the model is tested on four case studies for three battery chemistries representing distinct objectives: high‐power, high‐energy, and second life. Compared to traditionally designed battery storage with a homogeneous battery, optimally designed hybrid systems can save 12%–26% of system costs, depending on the nature of the dispatch profile. Findings point to design preference toward the second life battery supplemented with some high‐power or high‐energy battery capacity, or both. With the utilized electricity price structure, customers can experience approximately 10%–35% reduction in their bills.

Koleva, Mariya↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Indirect synthesis of multi-degree of freedom transient systems

An indirect synthesis method is used in the efficient optimal design of multi-degree of freedom, multi-design element, nonlinear, transient systems. A limiting performance analysis which requires linear programming for a kinematically linear system is presented. The system is selected using system identification methods such that the designed system responds as closely as possible to the limiting performance. The efficiency is a result of the method avoiding the repetitive systems analyses accompanying other numerical optimization methods.

Pilkey, W. D.↗

Computer Program For Linear Algebra

Collection of routines provided for basic vector operations. Basic Linear Algebra Subprogram (BLAS) library is collection from FORTRAN-callable routines for employing standard techniques to perform basic operations of numerical linear algebra.

Krogh, F. T.↗

Structural optimization with approximate sensitivities

Computational efficiency in structural optimization can be enhanced if the intensive computations associated with the calculation of the sensitivities, that is, gradients of the behavior constraints, are reduced. Approximation to gradients of the behavior constraints that can be generated with small amount of numerical calculations is proposed. Structural optimization with these approximate sensitivities produced correct optimum solution. Approximate gradients performed well for different nonlinear programming methods, such as the sequence of unconstrained minimization technique, method of feasible directions, sequence of quadratic programming, and sequence of linear programming. Structural optimization with approximate gradients can reduce by one third the CPU time that would otherwise be required to solve the problem with explicit closed-form gradients. The proposed gradient approximation shows potential to reduce intensive computation that has been associated with traditional structural optimization.

Patnaik, S. N.↗

Modeling the AC Power Flow Equations with Optimally Compact Neural Networks: Application to Unit Commitment

Nonlinear power flow constraints render a variety of power system optimization problems computationally intractable. Emerging research shows, however, that the nonlinear AC power flow equations can be successfully modeled using neural networks. These neural networks can be exactly transformed into mixed integer linear programs and embedded inside challenging optimization problems, thus replacing nonlinearities that are intractable for many applications with tractable piecewise linear approximations. Such approaches, though, suffer from an explosion of the number of binary variables needed to represent the neural network. Accordingly, this paper develops a technique for training an "optimally compact'' neural network, i.e., one that can represent the power flow equations with a sufficiently high degree of accuracy while still maintaining a tractable number of binary variables. We demonstrate the use of this neural network as an approximator of the nonlinear power flow equations by embedding it in the AC unit commitment problem, transforming the problem from a mixed integer nonlinear program into a more manageable mixed integer linear program. We use the 14-, 57-, and 89-bus networks as test cases and compare the AC-feasibility of commitment decisions resulting from the neural network, DC, and linearized power flow approximations. Our results show that the neural network model outperforms both the DC and linearized power flow approximations when embedded in the unit commitment problem. The neural network formulation most often selects a feasible unit commitment schedule, and furthermore, it only s

AC power flow↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Peak Power Reduction for HVAC Operations in Multi-unit Commercial Buildings

The load profiles of most commercial consumers are characterized by brief periods of very high power consumption followed by intervals of relatively lower demand. In order to flatten commercial load profiles, several power utilities in addition to billing energy consumption, levy a demand charge (DC) on the monthly peak demand. In this work, we consider the problem of joint optimization of energy costs (EC) and DC incurred by a multi-unit building which follows a demand response (DR) program. Despite the non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using linear programming. We evaluate the performance of the proposed power control scheme for various climate zones in the US. We show that depending on the ambient conditions and the prescribed tariff structure, our strategy can result in savings of up to nearly 19% compared to the baseline.

Raza Naqvi, Syed A.↗

A Multi-Parametric optimization approach for bilevel mixed-integer linear and quadratic programming problems

Optimization problems involving two decision makers at two different decision levels are referred to as bi-level programming problems. Herein, we present novel algorithms for the exact and global solution of two classes of bi-level programming problems, namely (i) bi-level mixed-integer linear programming problems (B-MILP) and (ii) bi-level mixed-integer convex quadratic programming problems (B-MIQP) containing both integer and bounded continuous variables at both optimization levels. Based on multi-parametric programming theory, the main idea is to recast the lower level problem as a multi-parametric programming problem, in which the optimization variables of the upper level problem are considered as bounded parameters for the lower level. The resulting exact multi-parametric mixed-integer linear or quadratic solutions are then substituted into the upper level problem, which can be solved as a set of single-level, independent, deterministic mixed-integer optimization problems. Extensions to problems including right-hand-side uncertainty on both lower and upper levels are also discussed. Finally, computational implementation and studies are presented through test problems.

42 ENGINEERING↗

Software For Integer Programming

Improved Exploratory Search Technique for Pure Integer Linear Programming Problems (IESIP) program optimizes objective function of variables subject to confining functions or constraints, using discrete optimization or integer programming. Enables rapid solution of problems up to 10 variables in size. Integer programming required for accuracy in modeling systems containing small number of components, distribution of goods, scheduling operations on machine tools, and scheduling production in general. Written in Borland's TURBO Pascal.

Fogle, F. R.↗

LFSPMC: Linear feature selection program using the probability of misclassification

The computational procedure and associated computer program for a linear feature selection technique are presented. The technique assumes that: a finite number, m, of classes exists; each class is described by an n-dimensional multivariate normal density function of its measurement vectors; the mean vector and covariance matrix for each density function are known (or can be estimated); and the a priori probability for each class is known. The technique produces a single linear combination of the original measurements which minimizes the one-dimensional probability of misclassification defined by the transformed densities.

Guseman, L. F., Jr.↗

The role of service areas in the optimization of FSS orbital and frequency assignments

A relationship is derived, on a single-entry interference basis, for the minimum allowable spacing between two satellites as a function of electrical parameters and service-area geometries. For circular beams, universal curves relate the topocentric satellite spacing angle to the service-area separation angle measured at the satellite. The corresponding geocentric spacing depends only weakly on the mean longitude of the two satellites, and this is true also for alliptical antenna beams. As a consequence, if frequency channels are preassigned, the orbital assignment synthesis of a satellite system can be formulated as a mixed-integer programming (MIP) problem or approximated by a linear programming (LP) problem, with the interference protection requirements enforced by constraints while some linear function is optimized. Possible objective-function choices are discussed and explicit formulations are presented for the choice of the sum of the absolute deviations of the orbital locations from some prescribed ideal location set. A test problem is posed consisting of six service areas, each served by one satellite, all using elliptical antenna beams and the same frequency channels. Numerical results are given for the three ideal location prescriptions for both the MIP and LP formulations. The resulting scenarios also satisfy reasonable aggregate interference protection requirements.

Levis, C. A.↗