Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

FGMS-poster

Idaho National Laboratory (INL) performs post irradiation examination (PIE) of tri-structural isotropic (TRISO)-coated particle fuel to help qualify it for high temperature gas cooled reactors. TRISO fuel compacts are re-irradiated in the Neutron Radiography Reactor (NRAD) to generate the short lived fission products needed for fission product release testing. The Fuel Accident Condition Simulator (FACS) furnace and newly added Screen Neutron Irradiated Fuel for Failure (SNIFF) furnace heat the compacts in helium to temperatures of up to 2,000°C, prompting fission product release—predominantly gaseous xenon and krypton isotopes and condensable products such as cesium—from failed particles. These released isotopes are transported to a fission gas monitoring system (FGMS 1 or FGMS 3), where they accumulate in cryogenic cold traps and are quantified using high-purity germanium (HPGe) detectors. The addition of SNIFF and FGMS 3 increases throughput by enabling simultaneous testing of multiple compacts. Furthermore, automated INL developed software provides continuous, near-real time monitoring of fission product inventories and manages the liquid nitrogen cooling of the traps. These system enhancements improve the efficiency, data quality, and testing capacity of TRISO fuel performance evaluations.

07 - ISOTOPES AND RADIATION SOURCES↗

Liquid pump for astronaut cooling

The Apollo portable life support system water-recirculation pump used for astronaut cooling is described. The problems associated with an early centrifugal pump and how these problems were overcome by the use of a new diaphragm pump are discussed. Performance comparisons of the two pump designs are given. Developmental problems and flight results with the diaphragm pump are discussed.

Carson, M. A.↗

Fail-safe system for activity cooled supersonic and hypersonic aircraft

A fail-safe-system concept was studied as an alternative to a redundant active cooling system for supersonic and hypersonic aircraft which use the heat sink of liquid-hydrogen fuel for cooling the aircraft structure. This concept consists of an abort maneuver by the aircraft and a passive thermal protection system (TPS) for the aircraft skin. The abort manuever provides a low-heat-load descent from normal cruise speed to a lower speed at which cooling is unnecessary, and the passive TPS allows the aircraft skin to absorb the abort heat load without exceeding critical skin temperature. On the basis of results obtained, it appears that this fail-safe-system concept warrants further consideration, inasmuch as a fail-safe system could possibly replace a redundant active cooling system with no increase in weight and would offer other potential advantages.

Jones, R. A.↗

SAM Finite Volume Method Development Status Update: GCR Application, Restart, and MultiApp

The System Analysis Module (SAM) is being developed as a modern system analysis code for advanced non-light-water-reactor safety analysis under the U.S. DOE NEAMS program. Previous feasibility studies have demonstrated that a staggered-grid finite volume method (SG-FVM), implemented under the MOOSE framework, can deliver more than an order of magnitude speedup over the existing continuous Galerkin finite element method (CG-FEM) solver for liquid-cooled, incompressible but thermally expandable flow systems. This work extends the previous effort to compressible, gas-cooled reactor applications, where pressure couples directly into the mass equation adding additional nonlinearity into the equation system. New code capabilities are implemented for pebble bed high-temperature gas-cooled reactor (PB-HTGR) analysis, including a pebble bed CoreChannel component, built-in pebble bed effective thermal conductivity model and channel-to-channel crossflow model. The capabilities are tested, benchmarked, and demonstrated for problems with increased level of model and physical complexities, including the HTTU effective thermal conductivity test, the SANA passive cooling test, and a demonstration case using the GPBR200 reactor design covering steady-state operation, DLOFC and PLOFC transients. Across all cases, the SG-FVM solver demonstrated strong robustness and efficiency, and the solutions agree well with reference results and data. The finding of this work proves that SG-FVM is a viable and efficient solver pathway for compressible, gas-cooled reactor system analysis in SAM. In addition, work has been done to successfully support SAM-FVM recover/restart code feature that is essential to reactor safety analysis applications, and MultiApp code feature that is essential to multi-scale and multi-physics simulations. In summary, this work continued from previous feasibility studies, and further demonstrated that the SG-FVM will serve as a strong foundation for SAM’s advanced solver algorithm for future deployment.

Zou, Ling↗

Antimicrobials for Water Systems in Manned Spaceflight - Past, Present, and Future Applications and Challenges

The use of antimicrobials to control microbiological growth in manned spaceflight water-based systems has and will continue to have a unique set of challenges and needs. The challenges are varied, and include antimicrobial effectiveness, crew health and safety, materials compatibility, optimal system functionality, antimicrobial shelf life, means to monitor antimicrobial concentration, and means to re-introduce biocides periodically in the case of depletion. Needs vary from application to application, and include control of pathogens for crew health, control of biofilm formation for optimal system functionality, inhibition and prevention of microbiologically influenced corrosion, optimization of wetted metallic material life, and general living quarter and consumable aesthetics with respect to odor and taste. This paper outlines and discusses the various antimicrobials used in prior and current manned spaceflight water-based applications with focus on pros, cons and lessons learned. Design factors such as minimum inhibitory concentration, minimum lethal concentration, required circulated concentrations, materials selection, means to introduce, means to monitor real-time, and concentration maintenance are discussed. The challenges associated with longer term missions, as well as long-term system dormancy as envisioned for exploration missions, lunar habitats, and a manned Mars mission are outlined with respect to anticipated needs and potential design solutions.

potable water↗

Cryogenic probe station for use in automated microwave and noise figure measurements

A cryogenic measurement system capable of performing on-wafer RF testing of semiconductor devices and circuits has been developed. This 'CryoProbe Station' can wafer-probe devices and circuits at cryogenic temperatures, thus eliminating the need for wire bonds. The system operates under vacuum created by a sorption pump. It uses an open cycle cooling system that can be cooled with either liquid nitrogen or liquid helium. Presently, it can reach temperatures, as low as 80 K and 37 K for each of the coolants, respectively. The temperature can be raised using a heater and it is stabilized to within 0.2 K by use of a temperature controller. The CryoProbe Station features a 1 by 2 inch stage that can hold large circuits and calibration standards simultaneously. The system is used with a Hewlett Packard 8510C Automatic Network Analyzer (ANA) to obtain S-parameter data over the frequency range 0.045-26.5 GHz. S-parameter data on HEMT (high electron mobility transistors) devices has been obtained with this station. With the use of DEEMBED software from NIST, detailed transmission line studies have been performed. Although the CryoProbe Station is designed for frequencies up to 26.5 GHz, useful transmission line data has been obtained for frequencies as high as 40 GHz. The CryoProbe station has also been used with the ATN noise figure measurement system to perform automatic, temperature dependent noise figure measurements.

Taub, Susan R.↗

NASA Tech Briefs, August 2005

Topics include: Hidden Identification on Parts: Magnetic Machine-Readable Matrix Symbols; System for Processing Coded OFDM Under Doppler and Fading; Multipurpose Hyperspectral Imaging System; Magnetic-Flux-Compensated Voltage Divider; High-Performance Satellite/Terrestrial-Network Gateway; Internet-Based System for Voice Communication With the ISS; Stripline/Microstrip Transition in Multilayer Circuit Board; Dual-Band Feed for a Microwave Reflector Antenna; Quadratic Programming for Allocating Control Effort; Range Process Simulation Tool; Simulator of Space Communication Networks; Computing Q-D Relationships for Storage of Rocket Fuels; Contour Error Map Algorithm; Portfolio Analysis Tool; Glass Frit Filters for Collecting Metal Oxide Nanoparticles; Anhydrous Proton-Conducting Membranes for Fuel Cells; Portable Electron-Beam Free-Form Fabrication System; Miniature Laboratory for Detecting Sparse Biomolecules; Multicompartment Liquid-Cooling/Warming Protective Garments; Laser Metrology for an Optical-Path-Length Modulator; PCM Passive Cooling System Containing Active Subsystems; Automated Electrostatics Environmental Chamber; Estimating Aeroheating of a 3D Body Using a 2D Flow Solver; Artificial Immune System for Recognizing Patterns; Computing the Thermodynamic State of a Cryogenic Fluid; Safety and Mission Assurance Performance Metric; Magnetic Control of Concentration Gradient in Microgravity; Avionics for a Small Robotic Inspection Spacecraft; and Simulation of Dynamics of a Flexible Miniature Airplane.

Source record↗

Thermal Analysis of a 100 kW Polyphase Wireless Power Transfer System

Charging Electric Vehicles (EVs) fast and safely has a crucial role in the future of the EV technology. High-power Wireless Power Transfer (WPT) helps to significantly decrease the charging time. However, when the power transfer levels increase, thermal management becomes a significant challenge. The thermal design of the WPT systems needs more consideration in the design and implementation steps. This paper presents a thermal analysis of a 100 kW high-power WPT system. The thermal performance of the proposed design was evaluated at different power levels by considering the magnetic design and loss analysis. Finite Element Analysis (FEA) of the proposed design was performed and the thermal images of the implemented system were taken to prove the simulation results. The results show that, a liquid cooling design is needed for a high-power WPT systems for the long-time continuous operations of the charging pads.

Aydin, Emrullah↗

A Comparison of Fission Power System Options for Lunar and Mars Surface Applications

This paper presents a comparison of reactor and power conversion design options for 50 kWe class lunar and Mars surface power applications with scaling from 25 to 200 kWe. Design concepts and integration approaches are provided for three reactor-converter combinations: gas-cooled Brayton, liquid-metal Stirling, and liquid-metal thermoelectric. The study examines the mass and performance of low temperature, stainless steel based reactors and higher temperature refractory reactors. The preferred system implementation approach uses crew-assisted assembly and in-situ radiation shielding via installation of the reactor in an excavated hole. As an alternative, self-deployable system concepts that use earth-delivered, on-board radiation shielding are evaluated. The analyses indicate that among the 50 kWe stainless steel reactor options, the liquid-metal Stirling system provides the lowest mass at about 5300 kg followed by the gas-cooled Brayton at 5700 kg and the liquid-metal thermoelectric at 8400 kg. The use of a higher temperature, refractory reactor favors the gas-cooled Brayton option with a system mass of about 4200 kg as compared to the Stirling and thermoelectric options at 4700 and 5600 kg, respectively. The self-deployed concepts with on-board shielding result in a factor of two system mass increase as compared to the in-situ shielded concepts.

Mason, Lee S.↗

Testing of Liquid Metal Components for Nuclear Surface Power Systems

The Early Flight Fission Test Facility (EFF-TF) was established by the Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a non-nuclear test methodology. This includes fabrication and testing at both the module/component level and near prototypic reactor configurations. The EFF-TF is currently supporting an effort to develop an affordable fission surface power (AFSP) system that could be deployed on the Lunar surface. The AFSP system is presently based on a pumped liquid metal-cooled (Sodium-Potassium eutectic, NaK-78) reactor design. This design was derived from the only fission system that the United States has deployed for space operation, the Systems for Nuclear Auxiliary Power (SNAP) 10A reactor, which was launched in 1965. Two prototypical components recently tested at MSFC were a pair of Stirling power conversion units that would be used in a reactor system to convert heat to electricity, and an annular linear induction pump (ALIP) that uses travelling electromagnetic fields to pump the liquid metal coolant through the reactor loop. First ever tests were conducted at MSFC to determine baseline performance of a pair of 1 kW Stirling convertors using NaK as the hot side working fluid. A special test rig was designed and constructed and testing was conducted inside a vacuum chamber at MSFC. This test rig delivered pumped NaK for the hot end temperature to the Stirlings and water as the working fluid on the cold end temperature. These test were conducted through a hot end temperature range between 400 to 550C in increments of 50 C and a cold end temperature range from 30 to 70 C in 20 C increments. Piston amplitudes were varied from 6 to 1 1mm in .5 mm increments. A maximum of 2240 Watts electric was produced at the design point of 550 hot end, 40 C cold end with a piston amplitude of 10.5mm. This power level was reached at a gross thermal efficiency of 28%. A baseline performance map was established for the pair of 1kW Stirling convertors. The performance data will then be used for design modification to the Stirling convertors. The ALIP tested at MSFC has no moving parts and no direct electrical connections to the liquid metal containing components. Pressure is developed by the interaction of the magnetic field produced by the stator and the current which flows as a result of the voltage induced in the liquid metal contained in the pump duct. Flow is controlled by variation of the voltage supplied to the pump windings. Under steady-state conditions, pump performance is measured for flow rates from 0.5-4.3 kg/s. The pressure rise developed by the pump to support these flow rates is roughly 5-65 kPa. The RMS input voltage (phase-to-phase voltage) ranges from 5-120 V, while the frequency can be varied arbitrarily up to 60 Hz. Performance is quantified at different loop temperature levels from 50 C up to 650 C, which is the peak operating temperature of the proposed AFSP reactor. The transient response of the pump is also evaluated to determine its behavior during startup and shut-down procedures.

Polzin, Kurt A.↗

Green Propellant Test Capabilities of the Altitude Combustion Stand at the NASA Glenn Research Center

The NASA Glenn Research Center (GRC) is committed to providing simulated altitude rocket test capabilities to NASA programs, other government agencies, private industry partners, and academic partners. A primary facility to support those needs is the Altitude Combustion Stand (ACS). ACS provides the capability to test combustion components at a simulated altitude up to 100,000 ft. (approx.0.2 psia/10 Torr) through a nitrogen-driven ejector system. The facility is equipped with an axial thrust stand, gaseous and cryogenic liquid propellant feed systems, data acquisition system with up to 1000 Hz recording, and automated facility control system. Propellant capabilities include gaseous and liquid hydrogen, gaseous and liquid oxygen, and liquid methane. A water-cooled diffuser, exhaust spray cooling chamber, and multi-stage ejector systems can enable run times up to 180 seconds to 16 minutes. The system can accommodate engines up to 2000-lbf thrust, liquid propellant supply pressures up to 1800 psia, and test at the component level. Engines can also be fired at sea level if needed. The NASA GRC is in the process of modifying ACS capabilities to enable the testing of green propellant (GP) thrusters and components. Green propellants are actively being explored throughout government and industry as a non-toxic replacement to hydrazine monopropellants for applications such as reaction control systems or small spacecraft main propulsion systems. These propellants offer increased performance and cost savings over hydrazine. The modification of ACS is intended to enable testing of a wide range of green propellant engines for research and qualification-like testing applications. Once complete, ACS will have the capability to test green propellant engines up to 880 N in thrust, thermally condition the green propellants, provide test durations up to 60 minutes depending on thrust class, provide high speed control and data acquisition, as well as provide advanced imaging and diagnostics such as infrared (IR) imaging.

Testing↗

Transient radiative cooling of a layer filled with solidifying drops

An analysis is carried out for radiative cooling of a plane layer initially filled with liquid drops that solidify and then continue to cool by loss of sensible heat. This is in connection with a proposed lightweight radiator system for heat dissipation in space. Hot liquid drops would be ejected and then cooled by direct exposure in space; they would then pass into a collector for reuse. The cooling analysis contains three transient zones. In the first, the drops cool by losing latent heat until the outermost drops become solid. Then the cooling continues by loss of both latent and sensible heat. A similarity behavior is eventually achieved in which the transient emittance of the layer depends only on the optical thickness.

Siegel, R.↗

Helium technology issues

A number of future space missions require liquid helium for cooling scientific payloads. These missions will require the long term storage and resupply of liquid helium at temperatures of 1.4 - 2.1 Kelvin. In addition, some of the proposed instruments will require refrigeration to temperatures as low as 50 mK. A variety of liquid helium based refrigerator systems could provide this subkelvin cooling. The status of helium storage and refrigeration technologies and of several alternative technologies is presented here along with areas where further research and development are needed. (Helium resupply technologies are the topic of another presentation at this symposium). The technologies covered include passive and dynamic liquid helium storage, alternatives to liquid helium storage, He -3 refrigerators, He -3/He -4 dilution refrigerators, and alternative sub-kelvin coolers.

Kittel, Peter↗

Magnetic refrigeration for low-temperature applications

The application of refrigeration at low temperatures ranging from production of liquid helium for medical imaging systems to cooling of infrared sensors on surveillance satellites is discussed. Cooling below about 15 K with regenerative refrigerators is difficult because of the decreasing thermal mass of the regenerator compared to that of the working material. In order to overcome this difficulty with helium gas as the working material, a heat exchanger plus a Joule-Thomson or other exponder is used. Regenerative magnetic refrigerators with magnetic solids as the working material have the same regenerator problem as gas refrigerators. This problem provides motivation for the development of nonregenerative magnetic refrigerators that span approximately 1 K to approximately 0 K. Particular emphasis is placed on high reliability and high efficiency. Calculations indicate considerable promise in this area. The principles, the potential, the problems, and the progress towards development of successful 4 to 20 K magnetic refrigerators are discussed.

Barclay, J. A.↗

A potassium Rankine multimegawatt nuclear electric propulsion concept

Multimegawatt nuclear electric propulsion (NEP) has been identified as a potentially attractive option for future space exploratory missions. A liquid-metal-cooled reactor, potassium Rankine power system that is being developed is suited to fulfill this application. The key features of the nuclear power system are described, and system characteristics are provided for various potential NEP power ranges and operational lifetimes. The results of recent mission studies are presented to illustrate some of the potential benefits to future space exploration to be gained from high-power NEP. Specifically, mission analyses have been performed to assess the mass and trip time performance of advanced NEP for both cargo and piloted missions to Mars.

Baumeister, E.↗

Growth of samarskite crystal under microgravity conditions (M-20)

The purpose of the experiment was to grow single crystals of samarskite under microgravity conditions by the traveling solvent float zone (TSFZ) method, and to study the phase relations in the samarskite-related systems involving liquid phases by the slow cooling float zone (SCFZ) method. Samarskite is one of the minerals in a metamict state and is composed of Ca, Fe, Y, U, Th, Nb, Ta, O, etc. Alpha-particles radiating from uranium and/or thorium in the samarskite itself has destroyed its original structure without damaging its chemical composition and its external form. Consequently its structure was converted into a vitreous structure.

Takekawa, S.↗

Thermal Performance Testing of EMU and CSAFE Liquid Cooling Garments

Future exploration missions require the development of a new liquid cooling garment (LCG) that offers greater system reliability, is more comfortable, and maximizes thermal performance. To inform the development of a future LCG a thermal performance test was conducted to evaluate three factors: (1) the effect of the thermal comfort undergarment (TCU) on tactile and thermal comfort, (2) the comparable thermal performance of an CSAFE developed engineering evaluation unit (EEU) LCG, which uses a commercial-off-the-shelf (COTS) wicking garment as the base, and (3) the performance of a torso or upper body only LCG configuration to evaluate a proposed auxiliary loop configuration. To evaluate the thermal performance of each configuration a metabolic suit test was conducted, utilizing suited subjects to generate metabolic heat by walking on a treadmill at various speeds. Three (3) test subjects of similar height and weight produced a metabolic load for five tests by either resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). During the test, data was collected that would allow us to track the heat transfer to the LCG and ventilation system to determine the thermal performance of the LCG configurations. Four different test configurations were tested, with one configuration tested twice. The test results show that the CSAFE EEU LCG and EMU LCG had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed the previous analysis that assumed a UA deterioration from the TCU was too conservative and the TCU may prove to be acceptable for future development with additional analysis and testing.

Rhodes, Richard↗