Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fundamental Properties of Confined Enzymes

We recently developed an enzymatically active, ultra-thin, nano-stabilized liquid membrane for CO 2 separation from a mixture of gases, which was recognized by an international R&D 100 Award in 2015. The separation membrane is an approximately 18-nm thick water layer stabilized by capillary condensation within a hydrophilic mesoporous silica film and embedded with the metallo-enzyme carbonic anhydrase. The enzyme speeds CO 2 uptake and release from the membrane by catalyzing the rapid inter-conversion of carbon dioxide and water to bicarbonate and a proton. The membrane separates CO 2 from 1:1 gas mixtures at a rate of 2600 GPU with CO 2 /N 2 and CO 2 /H 2 selectivities exceeding 788 and 1500, the highest combined flux and selectivity yet reported. That membrane performance exceeds, for the first time, the U.S. Department of Energy standards for CO 2 capture technology. CO 2 flux depends sensitively on nanopore surface chemistry in the active region. To understand that dependence, we applied molecular simulations to interrogate enzyme behavior in the presence of varied surface chemistries. The results indicate that a polar surface chemistry within the membrane nanopores prevents aggregation of enzymes that would otherwise occur in both bulk liquid solution and non-polar nanopores. Additionally, the enzyme active site maintains a stable structure, even when the overall protein structure deforms within the nanopores. In summary, confinement in the ultra-thin layer of water within mesoporous silica nanopores facilitates a 15x higher enzyme concentration than in bulk conditions, without affecting the structure of the enzyme active site, when the nanopore surfaces are covered with polar functional groups. Thus, confinement of the carbonic enzymes in the membrane water-filled nanopores facilitates higher rates of CO 2 uptake and release than achievable in bulk solutions.

59 BASIC BIOLOGICAL SCIENCES↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

Post-Marcus Theory and Simulation of Interfacial Charge Transfer Dynamics in Organic Semiconducting Materials (Final Report)

The research program developed, validated and applies predictive computational protocols for calculating charge transfer (CT) rates in complex molecular systems, including molecular dyads and triads in liquid solution and solid-state organic semiconducting (OSC) materials. We have established a transformative computational scheme that goes beyond widely used simplifications, to achieve realistic descriptions of CT processes. The approach properly addresses the contribution of molecular environment at ambient conditions to CT processes. Our approach achieves unique insight on investigated CT processes in relevant experimental efforts. The collaborative team included three principal investigators (PIs), with complimentary expertise in classical molecular dynamics simulations and data science (Cheung), state-of-the-art electronic structure calculations (Dunietz), and cutting-edge theory and simulation techniques for modeling energy, charge and coherence transfer dynamics in molecular systems (Geva).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Molecular Structure and Dynamics of Molten Salts by Advanced Neutron and X-ray Scattering Measurements and Computer Modeling

The design and development of fully functional Molten-Salt Reactors (MSR) require detailed knowledge of the molten salt properties in order to understand and predict the salt’s behavior. Fundamental properties of interest include molecular structure, speciation, and dynamics (such as diffusion coefficients) of salt components and dissolved corrosion and fission products. Computer modeling is necessary to predict changes in physical and chemical properties due to irradiation, burning of dissolved fuel, and corrosion. The modeling requires experimental data, and advanced neutron and x-ray scattering and spectroscopy provide the most reliable and direct determination of the structure (Pair-Distribution Functions, PDF), and dynamics of ions in the melt. This project dealt with both fluoride and chloride salts. The PDFs have been measured by a combination of neutron and x-ray diffraction. We utilized the techniques of isotope substitutions, a very powerful tool available for neutron-scattering, to extract the details of the liquid structure. Although similar measurements have been done before, modern advanced neutron and x-ray-scattering techniques allow collecting the data at much higher resolution and in a wider range of temperatures. Importantly, we were among the first to study fluoride salts by neutron scattering. The importance of impurities and their effects on salt properties have become apparent recently and so new methods of salt purification were developed. We took advantage of these developments to produce reliable data, which have been used for computer simulations of both clean salts and those with added fission and corrosion products most relevant for MSRs. Ab initio molecular dynamics simulations have been performed to understand the multi-component liquid solution, in particular solubility of impurities and thermodynamic interactions in relation to the ionic-cluster structure of the fluid. We applied machine learning to regress from the simulation and experimental data in order to develop a fast-acting model that can handle molten salt with an arbitrary (≥ 10) number of chemical elements and be able to predict chemical potential as a function of composition and temperature. This project resulted in a number of experimental and computer-simulation publications, a patent application, and numerous conference presentations (American Physical Society, American Chemical Society, and The Electrochemical Society among others). Multiple students and postdocs participated and collaborated on aspects of this project. This project seeded new collaborations between MIT and other institutions, such as the University of Massachusetts Lowell, the University of Illinois Urbana-Champaign, the University of California Berkeley, and Oak Ridge and Los Alamos National Labs. As such, this project has had a broad and lasting impact beyond its original scientific scope.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Health Hazards of Exposures to Radioiodine

Iodine is a chemical element with atomic number 53. Iodine-127 is stable (non-radioactive) and commonly found in nature. Elemental iodine is a purple-colored solid at room temperature and pressure, but spontaneously sublimates (turns into vapor). Iodine is an essential element for life, and is required for proper functioning of the thyroid. Iodine is present in many foods, and is readily absorbed by the body and concentrated in the thyroid gland. A fraction of iodine ingested or inhaled is rapidly removed by the kidneys. The rest of the inhaled or ingested iodine is absorbed the by thyroid and retained for many months. Iodine has a biological half-life of approximately 120 days in health individuals. The biological half-life can be shorter in individuals with hyperthyroidism, and longer in individuals with hypothyroidism. Iodine has a number of radioactive isotopes, most of which have relatively short half-lives (days or weeks). Short half-life iodine isotopes are useful for a variety of medical applications, including imaging and cancer therapy. For example, Iodine-123 (half-life 13 hours) is commonly used for medical imaging of the thyroid, while iodine-131 (half-life 8 days) is used for suppressing thyroid function in individuals with hyperthyroidism or ablating (killing) thyroid cells to treat thyroid cancer. Iodine-125 (half-life 59 days) is produced in nuclear reactors, and has medical uses. Although iodine-125 can be used for thyroid imaging, Iodine-123 is more commonly used for that purpose because of its shorter half-life and higher-energy emissions. Iodine-125 is more commonly used for cancer treatment, and can be processed into small metal pellets (seeds) inserted directly into a tumor. Iodine-125 emits low-energy x-rays which can kill tumor cells and generally cannot escape the tumor, sparing other tissues. Medical iodine for imaging or treatment is typically administered orally in the form a pill or liquid solution. A typical adult thyroid scan using iodine-123 involves having the patient swallow between one and four 0.1 millicuries pills, with the exact dose dependent on the patient’s weight. This results in a whole-body committed effective dose of 80 – 320 mrem, and a thyroid equivalent dose of 1443 – 5772 mrem. Note that the whole-body effective dose relates to the overall cancer risk, while the larger equivalent dose to the thyroid only indicates that most of this risk is the result of exposure to the thyroid. These doses are considered safe, although the procedure is not recommended for pregnant or breastfeeding women. In contrast, the quantities of iodine-131 used for treatment of hyperthyroidism and thyroid cancers are much higher. For treatment of hyperthyroidism, 4 – 10 millicuries are administered, while for thyroid cancer the administration can range from 50 – 150 millicuries of I-131. In addition to medical exposures, large populations were exposed to radioiodine as result of the atomic bombings of Hiroshima and Nagasaki in Japan, and the Chernobyl nuclear accident. These populations have been carefully followed for many years to assess the effect of their radiation exposures on cancer risk. As a result, a great deal is known about the cancer risks associated with radioiodine exposure. Because iodine is concentrated in the thyroid, the principal risk of exposure to radioiodine is thyroid cancer. Children have the highest risk of thyroid cancer after exposure to radioactive iodine. According to a large study of Japanese atomic bomb survivors, an effective dose of one Sievert (100,000 mrem) has been observed to increase the risk of thyroid cancer by a factor of 9.5 in children aged zero to nine years old, by a factor of 3 in children aged 10 to 19 years old, and by barely detectable amounts in adults. Another way of quantifying the risk from radioiodine exposure is from risk coefficients, which provide the risk per unit intake of radionuclides in terms of both morbidity (any cancer) and mortality (death). Both morbidity (risk of cancer) and mortality (death) risks are shown in the table below. Note that because thyroid cancer is almost never fatal, the morbidity coefficients are much larger than the mortality coefficients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Direct Laser Writing of Magneto-Photonic Sub-Microstructures for Prospective Applications in Biomedical Engineering

Here, we report on the fabrication of desired magneto-photonic devices by a low one-photon absorption (LOPA) direct laser writing (DLW) technique on a photocurable nanocomposite consisting of magnetite ( Fe 3 O 4 ) nanoparticles and a commercial SU-8 photoresist. The magnetic nanocomposite was synthesized by mixing Fe 3 O 4 nanoparticles with different kinds of SU-8 photoresists. We demonstrated that the degree of dispersion of Fe 3 O 4 nanoparticles in the nanocomposite depended on the concentration of Fe 3 O 4 nanoparticles, the viscosity of SU-8 resist, and the mixing time. By tuning these parameters, the most homogeneous magnetic nanocomposite was obtained with a concentration of about 2 wt % of Fe 3 O 4 nanoparticles in SU-8 2005 photoresist for the mixing time of 20 days. The LOPA-based DLW technique was employed to fabricate on demand various magneto-photonic submicrometer structures, which are similar to those obtained without Fe 3 O 4 nanoparticles. The magneto-photonic 2D and 3D structures with sizes as small as 150 nm were created. Finally, we demonstrated the strong magnetic field responses of the magneto-photonic nanostructures and their use as micro-actuators when immersed in a liquid solution. View Full-Text

36 MATERIALS SCIENCE↗

Pyrophoric metal-carbon foam composites and methods of making the same

A method for creating a pyrophoric material according to one embodiment includes thermally activating a carbon foam for creating micropores therein; contacting the activated carbon foam with a liquid solution comprising a metal salt for depositing metal ions in the carbon foam; and reducing the metal ions in the foam to metal particles. A pyrophoric material in yet another embodiment includes a pyrophoric metal-carbon foam composite comprising a carbon foam having micropores and mesopores and a surface area of greater than or equal to about 2000 m.sup.2/g, and metal particles in the pores of the carbon foam. Additional methods and materials are also disclosed.

36 MATERIALS SCIENCE↗

Microfluidic sieve valves

Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of mixed sources with an organic scintillator-based radiation portal monitor

We have developed radionuclide identification algorithms for radiation portal monitor applications. One algorithm uses a spectral angle mapper to match the power spectral density of modified cumulative distribution functions of measured pulse height distributions to reference spectra, while the others rely on the decomposition of the observed spectrum as a linear mixture of known radionuclide spectra. Three algorithms were then tested for their ability to perform on-the-fly radionuclide identification on datasets acquired with a liquid organic scintillator-based pedestrian radiation portal monitor on moving special nuclear material and industrial radiological sources, as well as common medical isotopes. We quantified and compared the relative efficacies of the algorithms considered using F-score analysis. Measured radiation sources included 51 g of highly enriched uranium, 6.6 g of weapons grade plutonium, 241 Am, 133 Ba, 57 Co and 137 Cs sources with activities of several hundred kBq, as well as 260 kBq liquid solution samples of the medical isotopes 99m Tc, 111 In, 67 Ga, 123 I, 131 I, and 201 Tl. We achieved 100% positive identification, for three-second measurements of single sources moving at a source-transit speed of 1.2 m/s. For mixed sources with strongest and weakest sources having no more than a 5:1 ratio of detected counts, encouraging positive identification results were achieved with the un-mixing algorithms. Current radiation portal monitor designs suffer from a high incidence rate of nuisance radiation alarms caused in radiation portal monitor primary screenings by recent nuclear medicine patients and cargo containing large amounts of naturally occurring radioactive materials. Integrating reliable on-the-fly radionuclide identification into the radiation portal monitors could lower the number of nuisance alarms requiring time-consuming secondary inspections.

47 OTHER INSTRUMENTATION↗

Material deposition techniques for control of solid state aperture surface properties

The invention provides a method for molecular analysis. In the method, sidewalls are formed extending through a structure between two structure surfaces, to define an aperture. A layer of material is deposited on the aperture sidewalls and the two structure surfaces. The aperture with the deposited material layer is then configured in a liquid solution with a gradient in a chemical potential, between the two structure surfaces defining the aperture, that is sufficient to cause molecular translocation through the aperture.

Branton, Daniel↗

Enhanced microfabrication using electrochemical techniques

A method is provided for subtractively processing a layer of etchable material formed over an electrically conductive surface region of a workpiece. The workpiece is immersed in a liquid solution, generally but not exclusively a conductive solution, that comprises an etchant for the etchable material, so that etching of the etchable material is initiated. An electric circuit is connected to include a control electrode, a reference electrode, and the electrically conductive surface region of the workpiece. The electric circuit is used to monitor the development process dynamically at each of a plurality of intervals during the etching. The etching is terminated when the electrochemical signal satisfies a criterion indicating that the etching is complete.

Arrington, Christian↗

New exact spatial and periodic-singular soliton solutions in nematic liquid crystal

The enterprising of nematicons has procured considerable recognition during the last few years due to its utilization in crystal technology. This research work contains some new exact traveling waves solutions in nematic liquid crystals. The modified simple equation method is employed to extract new traveling wave solutions. Two types of nonlinear mediums are investigated in this paper. New singular, periodic-singular and spatial solitons in liquid crystal are obtained by using analytical approach. The constraints fall out as the byproduct that guarantee their existence. The solutions are also highlighted graphically. This paper is leading to explore some unaccustomed results into this area of research.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionic Liquid versus Li+ Aqueous Solutions: Water Dynamics near Bistriflimide Anions

In this work, the ultrafast dynamics of concentrated aqueous solutions of the salt lithium bistriflimide and the ionic liquid 1-ethyl-3-methylimidazolium bistriflimide (EmimNTf 2 ) were studied using two-dimensional infrared (2D IR) vibrational echo and polarization-selective IR pump-probe techniques to monitor water’s hydroxyl stretch. Two distinct populations of hydroxyl groups, with differing vibrational lifetimes, are detected in solution – those engaged in hydrogen bonds to other water molecules or to the bistriflimide anion. Water molecules with the same hydrogen bond partner exhibit similar vibrational lifetimes in the two solutions. The reorientation dynamics of the anion-associated waters are also similar in form in the two solutions, showing a restricted wobbling-in-a-cone motion followed by a slower diffusive orientational randomization. However, the wobbling motions are much more angularly restricted in the ionic liquid solution. Spectral diffusion dynamics, which track the structural fluctuations of water’s hydrogen bonds, are very different in the two solutions. Water in the ionic liquid solution experiences much faster fluctuations overall and shows a greater extent of motional narrowing, resulting in a larger homogeneously broadened component in the spectral line, compared to the aqueous lithium salt. Thus, even when the hydroxyls of water associate with the same anion in solution, the cation identity and extent of ionic ordering (i.e., salt solution versus ionic liquid) can play an important role in determining the structural fluctuations experienced by a small hydrogen bonded solute.

14 SOLAR ENERGY↗

Phase Behavior and Ionic Conductivity of Concentrated Solutions of Polystyrene-Poly(ethylene oxide) Diblock Copolymers in an Ionic Liquid

Concentrated solutions of poly(styrene-b-ethylene oxide) (PS-PEO) diblock copolymers were prepared using the ionic liquid 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide [EMI][TFSI] as the solvent. The self-assembled microstructures adopted by the copolymer solutions have been characterized using small-angle X-ray scattering. Lyotropic mesophase transitions were observed, with a progression from hexagonally packed cylinders of PEO, to lamellae, to hexagonally packed cylinders of PS upon increasing [EMI][TFSI] content. The change in lamellar domain spacing with ionic liquid concentration was found to be comparable to that reported for other block copolymers in strongly selective solvents. The ionic conductivity of the concentrated PS-PEO/[EMI][TFSI] solutions was measured via impedance spectroscopy, and ranged from 1 x 10{sup -7} to 1 x 10{sup -3} S/cm at temperatures from 25-100 C. Additionally, the ionic conductivity of the solutions was found to increase with both ionic liquid concentration and molecular weight of the PEO blocks. The ionic conductivity of PEO homopolymer/[EMI][TFSI] solutions was also measured in order to compare the conductivity of the PS-PEO solutions to the expected limit for a lamellar sample with randomly oriented microstructure grains.

36 MATERIALS SCIENCE↗

Sodium-halogen secondary cell

A sodium-halogen secondary cell that includes a negative electrode compartment housing a negative, sodium-based electrode and a positive electrode compartment housing a current collector disposed in a liquid positive electrode solution. The liquid positive electrode solution includes a halogen and/or a halide. The cell includes a sodium ion conductive electrolyte membrane that separates the negative electrode from the liquid positive electrode solution. Although in some cases, the negative sodium-based electrode is molten during cell operation, in other cases, the negative electrode includes a sodium electrode or a sodium intercalation carbon electrode that is solid during operation.

Bhavaraju, Sai↗

Extraction of Uranium from Aqueous Solutions Using Ionic Liquid and Supercritical Carbon Dioxide in Conjunction

Uranyl ions (UO2)2+ in aqueous nitric acid solutions can be extracted into supercritical CO2 (sc-CO2) via an imidazolium-based ionic liquid using tri-n-butylphosphate (TBP) as a complexing agent. The transfer of uranium from the ionic liquid to the supercritical fluid phase was monitored by UV/Vis spectroscopy using a high-pressure fiberoptic cell. The form of the uranyl complex extracted into the supercritical CO2 phase was found to be UO2(NO3)2(TBP)2. The extraction results were confirmed by UV/Vis spectroscopy and by neutron activation analysis. This technique could potentially be used to extract other actinides for applications in the field of nuclear waste management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for treating a liquid using draw solutions

Draw solutions comprising at least one N-cyclicalkyl-cycloalkylamine and a secondary solvent. The N-cyclicalkyl-cycloalkylamine comprises the chemical structure: ##STR00001## wherein n is 0, 1, or 2, n' is 0, 1, or 2, and each of R.sup.1-R.sup.6 is independently selected from the group consisting of an alkyl group, an alkoxy group, an acetyl group, an aryl group, a hydrogen group, a hydroxyl group, and a phosphorus-containing group. Methods of treating a liquid using the draw solution are also disclosed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method for assaying radiation

A system for assaying radiation includes a sample holder configured to hold a liquid scintillation solution. A photomultiplier receives light from the liquid scintillation solution and generates a signal reflective of the light. A control circuit biases the photomultiplier and receives the signal from the photomultiplier reflective of the light. A light impermeable casing surrounds the sample holder, photomultiplier, and control circuit. A method for assaying radiation includes placing a sample in a liquid scintillation solution, placing the liquid scintillation solution in a sample holder, and placing the sample holder inside a light impermeable casing. The method further includes positioning a photomultiplier inside the light impermeable casing and supplying power to a control circuit inside the light impermeable casing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗