Search NASA⌕ Search

SEARCH · Search NASA

Results for “load control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Overview of the ICRF heating system in SPARC

Ion Cyclotron Range of Frequencies (ICRF) heating is a critical system for the SPARC mission of demonstrating net positive fusion gain. In the first campaign, 20 MW of installed power at 120 MHz will be supplied to 10 four-strap antennas, arranged in poloidal pairs. The matching network is designed to accommodate for a range of loading conditions and a fast controller adjusts the matching during a pulse with frequency modulation of ±1 MHz. For the main L-mode scenario of the first experimental campaign, the power coupling and absorption is analysed in this work. Several feeding schemes are compared and limits on the amount of the total coupled power are evaluated. Coupling of the full 20 MW power is possible well within the limit of the peak electric field in the transmission line of 15 kV/cm. The 3 He minority and 2 nd harmonic T heating scheme is validated in full-wave modelling to be efficient for heating plasma in the SPARC L-mode Q>1 scenario, with dominant ion heating and efficient single-pass absorption. A range of ICRF wave parameters and minority concentration would be suitable for operation and allow tailoring the heating properties for plasma conditions and experimental objectives.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tokamak level performance in the optimized stellarator Wendelstein 7-X with stable peaked density profiles

Progress towards achieving net gain from nuclear fusion is typically characterized by the triple product 𝑛⁢𝑇⁢𝜏. Although stellarators have several benefits for a reactor, such as the inherent steady-state capability and the lack of disruptions, the maximum achieved triple product has historically lagged behind that of tokamaks. In the large optimized stellarator Wendelstein 7-X, a triple product of (1.10 ± 0.15) × 10 20 m −3 ⁢ keVs has recently been achieved and held stable for 1.9 s. This marks an important step in stellarator core plasma performance and puts it in line with 𝐻-mode performance in similar sized tokamaks. The progress in Wendelstein 7-X performance is due to the suppression of ion-temperature-gradient turbulence by strong density gradients. In the record case, these are maintained by a fine balance of the core particle transport and central fueling using neutral beam injection. The duration of the scenario was limited in time only by technical restrictions of the neutral beam injectors and control of the divertor heat loads. This paper presents the result in the context of the leading magnetic confinement devices along with details of the scenario.

Bannmann, Sebastian [Max Planck Institute for Plas↗

Environmental Validation of Materials and Design Concepts to Enable Operational Flexibility of Existing Coal Power Plants

Increasingly, coal-fired power plants are required to balance power grids by compensating for the variable electricity supply from renewable energy sources. Fossil-fueled power plants, originally designed to be base loaded, will increasingly need to operate on a load following or cyclic basis. This demanding requirement for operational flexibility will need to be evaluated for resilience to frequent start-ups, meeting major and rapid load changes, and providing frequency control duties. Our research objective was to evaluate and improve flexibility of existing power plants by improving and redesigning components and defining new operational strategies, with acceptable impacts on component life, efficiency and emissions.

20 FOSSIL-FUELED POWER PLANTS↗

Cellulose molecular weight of corn stover with cotreatment

Here we present a dataset of cellulose molecular weights from corn stover after a cotreatment process. The corn stover sample was subjected to a combination of mechanical disruption (ball milling) and consolidated bioprocessing (CBP) process using the bacterium C. thermocellum at 60 grams/L solids loadings. Cellulose was isolated from control, no cotreatment control, and cotreatment corn stover. Cellulose was then derivatized using anhydrous pyridine and phenyl isocyanate over 48 h at 70 ºC. The reaction was quenched by anhydrous methanol. Methanol and water mixture (7:3, v/v) was added dropwise to promote precipitation of the cellulose derivative. The solids were collected by filtration and thoroughly washed with the methanol and water mixture followed by water. The cellulose derivative was dried overnight under vacuum at 40°C. The obtained cellulose tricarbanilates was then dissolved in tetrahydrofuran (THF) at 1.0 mg/mL and the solution was filtered through a 0.45 µm PTFE filter and placed in an auto-sampler vial. The molecular weight of cellulose was measured by Agilent GPC SECurity 1200 system equipped with four Waters Styragel columns (i.e., HR0.5, HR2, HR4, and HR6) and a UV detector (270 nm). THF was used as the mobile phase. Data collection and processing was performed by Polymer Standards Service WinGPC Unity software (Build 6807). The molecular weight was calculated relative to the polystyrene calibration curve. The data on molecular weights provided information about the effects of cotreatment on corn stover cellulose molecular changes.

Cellulose, molecular weights, corn stover, cotreat↗

Impact of Selenium and Vitamin E Deficiency on Zika Virus Pathogenesis and Immune Response in Mice

Micronutrient status is recognized to influence host susceptibility to viral infections, yet its impact on Zika virus (ZIKV) pathogenesis remains incompletely understood. We investigated the effects of dietary selenium and combined selenium plus vitamin E deficiency on ZIKV infection outcomes in a type I interferon α/β receptor knockout (Ifnar1 −/− ) murine model. Mice maintained on deficient diets exhibited significantly lower neutralizing antibody titers and reduced levels of key antiviral cytokines (IFN-γ, TNF-α, IFN-α, IFN-β, IL-12p70, CCL5) compared to controls. Correspondingly, higher viral RNA loads were detected in the brains of double-deficient mice, which also experienced greater weight loss and increased mortality. Deep sequencing revealed no major differences in overall viral genome diversity across diet groups; however, specific mutations, including V330L and D67E in the E gene, and V360I in the NS3 gene, were enriched or detected in nutritionally deficient animals. These findings suggest that antioxidant micronutrient deficiency impairs both humoral and cellular immune responses to ZIKV, potentially facilitating enhanced neuroinvasion. While the functional consequences of the identified mutations warrant further investigation, our results underscore the importance of adequate micronutrient intake for optimal antiviral defense. Further studies are needed to clarify the epidemiological significance of these observations.

Biological and medical sciences↗

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular DC circuit breaker with integrated energy storage for future DC networks

A T-breaker is an all-in-one solution for dc microgrid fault protection, power flow control, and power quality improvement. A T-breaker features a modular multilevel “T” structure with integrated energy storage devices. The two horizontal arms of the T-breaker realize fault current breaking, load voltage compensation, and power flow control; and the vertical arm of the T-breaker realizes shunt compensation. The configuration provides excellent voltage scalability and relaxes the requirements on the switching signal synchronization during fault transients. The local energy storage in sub-modules eases the fault energy dissipation requirement placed on the traditionally-adopted surge arrestors. The modular multilevel structure also offers immense control flexibility for all types of targeted functions of the provided T-breaker.

Wang, Jin↗

Precise Motion Control of Hybrid Hydraulic Electric Architecture (HHEA)

Off-highway heavy-duty vehicles have been long-standing users of hydraulic systems for power transmission and control. However, traditional hydraulic systems suffer from significant energy losses which lead to increased operating costs and a larger carbon footprint due to higher CO2 emissions. Improving the efficiency of these mobile machines is crucial not only for reducing their environmental impact but also for saving billions of dollars in operating costs. Currently, the state-of-the-art Load Sensing Architecture uses throttling valves for control, which significantly reduces its efficiency and does not recuperate energy from over-running loads. Researchers have developed several architectures such as Common Pressure Rail systems, Displacement Control, STEAM, and Electrohydraulic Architecture to improve the efficiency of off-road mobile machines. However, each of these architectures has its drawbacks. To increase system efficiency and take advantage of electrification benefits, our research group has developed a novel Hybrid Hydraulic-Electric Architecture (HHEA). The HHEA can significantly improve efficiency, decrease the size of electrical components, and maintain control performance. This new architecture has the potential to revolutionize the off-highway mobile machine industry and lead to a more sustainable future. The HHEA uses a set of common pressure rails to provide the majority of power to the actuators via power-dense hydraulics and uses electric motors for precise control and power modulation. In the context of off-road mobile machines, energy savings are undoubtedly important but it is equally important to consider the machines’ ability to perform tasks with precision and accuracy according to given commands. Therefore, precise motion control is of utmost importance to maintain the utility of Hybrid Hydraulic-Electric Architecture (HHEA). The HHEA presents a unique challenge to motion control due to the discrete pressure changes that occur when the system switches between selected pressure rails. These changes are made to minimize system inefficiencies or to keep the system within the torque capability of the electric motor. Hence, it is important to solve the motion control challenges for HHEA. This thesis aims at developing an effective motion control strategy for HHEA. The dissertation presents a two-tiered control strategy for HHEA, comprising a high-level and a low-level controller. The primary responsibility of the high- level controller is to optimize energy efficiency by making informed pressure rail selections. On the other hand, the low-level controller is focused on achieving precise motion control of the HHEA, which is crucial for realizing the desired reference trajectories. To achieve this, the low-level controller utilizes a passivity-based backstepping integral controller as the nominal control, which handles the motion control between two pressure rail switches. Additionally, a separate least norm controller is utilized as a transition controller to manage motion control during pressure rail transitions. The effectiveness of the combined control strategy is demonstrated through experiments conducted on two hardware-in-the-loop testbeds. Furthermore, the HHEA is installed on the boom and stick actuators of a backhoe arm to build a Human-in-the-Loop system that a human operator can control. A real-time rail switching algorithm is developed to determine pressure rail switching based on present duty cycle information from the operator. Modifications have been made to the human-machine interface to achieve more intuitive control. Modifications include performing control in the task-oriented coordinates, incorporating pressure feedback to enhance control with physical interaction, and using velocity field control to simplify multi-degree-of-freedom tasks and to enable novice operators to perform them with reduced risk, improved efficiency, and productivity. The research in this dissertation makes significant contributions to the field of off-road mobile machine control, providing a novel and effective control strategy for the HHEA, and demonstrating the potential for simplified machine operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Development of near-optimal advanced control sequences for chiller plants with water-side economizers in U.S. Climates (ASHRAE RP-1661)

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.

42 ENGINEERING↗

Subsurface hydrological controls on the short-term effects of hurricanes on nitrate–nitrogen runoff loading: a case study of Hurricane Ida using the Energy Exascale Earth System Model (E3SM) Land Model (v2.1)

When the nutrient level in the soil surpasses vegetation demand, nutrient losses due to surface runoff and subsurface leaching are the major reasons for the deterioration of water quality. The lower Mississippi River basin (LMRB) is one of the sub-basins that deliver the highest nitrogen loads to the Gulf of Mexico. Potential changes in episodic events induced by hurricanes may exacerbate water quality issue in the future. However, uncertainties in modeling the hydrologic response to hurricanes may limit the modeling of nutrient losses during such events. Using a machine learning approach, we calibrated the land component of the Energy Exascale Earth System Model (E3SM), or ELM, version 2.1, based on the water table depth (WTD) of a calibrated 3D subsurface hydrology model. While the overall performance of the calibrated ELM is satisfactory, some discrepancies in WTD remain in slope areas with low precipitation due to the missing lateral flow process in ELM. Simulations including biogeochemistry performed using ELM with and without model calibration showed important influences of soil hydrology, precipitation intensity, and runoff parameterization on the magnitude of nitrogen runoff loss and the leaching pathway. Despite such sensitivities, both ELM simulations produced reduced WTD and increased runoff and accelerated nitrate–nitrogen runoff loading during Hurricane Ida in August 2021, consistent with the observations. With observations suggesting more pronounced effects of Hurricane Ida on nitrogen runoff than the simulations, we identified factors for model improvement to provide a useful tool for studying hurricane-induced nutrient losses in the LMRB region.

54 ENVIRONMENTAL SCIENCES↗

Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Modeling, Validation, and Control of the IEA‐15 MW Reference Wind Turbine and VolturnUS‐S Platform

This paper presents the acausal modeling, validation, and control of floating offshore wind turbines (FOWTs). The model simulates the IEA‐15 MW reference turbine and the semi‐submersible VolturnUS‐S platform utilizing a Control‐oriented, Reconfigurable, and Acausal Floating Turbine Simulator (CRAFTS), which integrates the key coupled aero‐hydro‐elasto‐servo dynamics and is being developed by authors at the University of Central Florida. Verification and validation are conducted using numerical data from the industry‐standard simulation platform OpenFAST and experimental data from the Floating Offshore‐wind and Controls Advanced Laboratory (FOCAL) project, in which the authors were involved. Numerical results demonstrate the model's ability to qualitatively capture loads and responses across various load cases, highlighting the impact of the control system under different wind and wave conditions and opening new opportunities for optimizing FOWT designs. This paper provides wind turbine researchers with valuable insights into system characteristics, system frequencies, damping effects, and internal reaction forces, serving as a reference for future studies in FOWT modeling and control.

17 WIND ENERGY↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be time-consuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the tower-base damage equivalent loading and better tracking of the rated generator speed and power.

axial flow↗

Real time computations of cryogenic He properties

The Fermilab PIP-II (proton improvement plan - II) project is being constructed at Fermilab to deliver $800\,MeV$ protons of $>1\,MW$ beam power to replace the present LINAC and provide protons to the remainder of the existing accelerator complex. The new LINAC consists of a warm front end, 23 superconducting RF cryomodules, and a beam transfer line to the existing complex. The cryomodules (CMs) are to be tested at Fermilab's CryoModule Test Facility (CMTF).An important measurement in cryogenic testing is the heat load of each CM. Traditionally, at Fermilab, these measurements were made collecting archived data offline and analyzing it. The new control system for PIP-II is being developed with the EPICS (Experimental Physics and Industrial Control System) framework, which allows us to compute the heat load in real time using the HePak library.We are exploring other $He$ properties, such as flow, where flow meters are not available, which can also be calculated in real time and fed back to the cryogenics engineers.This paper details the real time heat load calculation and $He$ flow software developed for CM testing at CMTF, as well as the first results from the prototype HB650 CM. Future plans for 2-phase $LHe$ flow will also be outlined.

Hanlet, Pierrick [Fermilab]↗

LLM-Based Adaptive Distribution Voltage Regulation Under Frequent Topology Changes: An In-Context MPC Framework

This paper proposes a large language model (LLM) based adaptive inverter control for distribution voltage regulation under frequent topology changes. We leverage the ability of the LLM to perform in-context learning and create a topology-adaptive surrogate model for power flow calculation. The surrogate model is then integrated with a long short-term memory-based load forecaster and a model predictive control (MPC) scheme to achieve the optimal inverter control that adapts to frequent topology changes. Unlike many existing works that assume fixed-topology grids or require the knowledge of all possible topologies when training a model, the proposed in-context MPC method tackles the distribution voltage control problem under various topologies and adapts to unknown topologies with limited data requirement for fine-tuning. The effectiveness of our method is demonstrated on a modified IEEE 123-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗