Search NASA⌕ Search

SEARCH · Search NASA

Results for “local control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Bioinspired mineralizing microenvironments generated by liquid-liquid phase coexistence

Biominerals such as bones, teeth and shells exhibit improved mechanical properties and intricate morphologies not seen in nonbiologically-produced minerals of ostensibly the same composition. These remarkable properties of biogenic minerals are thought to arise due to precise local control over the mineral deposition process, including organic and inorganic inclusions. Understanding how Biology controls the local reaction environment during formation of these materials to control their composition, structure, and properties is a grand challenge that promises to enable new routes to high-performance materials. This project developed multi-compartment bioinspired microreactors as artificial mineralizing vesicles, and used them to understand and control formation of inorganic/organic composite solid materials. A major emphasis was on developing all-aqueous emulsions in which each droplet was a structured microreactor with two or more adjacent phases. This approach provided local control over reaction environment including availability of inclusions such as polypeptides and metal ions, while being sufficiently simple to produce large populations of essentially identical multiphase reactor droplets simultaneously within a batch. Organic/inorganic composite materials could be produced with very high organic content that stabilized the inorganic portions as amorphous materials (e.g., amorphous calcium carbonate) by preventing the typical conversion to more thermodynamically crystalline forms (e.g., calcite). These stabilized amorphous composites could be stored indefinitely and converted to crystalline forms later by removal of the organic inclusions via, for example, heating. Compositional gradients in the organic and inorganic components were embedded during synthesis due to the evolution of the reaction microenvironment, and despite the complexity of this process it occurred similarly across the population of reactive droplets and was hence encoded into the population of resulting composite particles. The approach developed here allows pre-structuring of reactive microenvironments to control the spatiotemporal reaction environment, which is an important step towards rational design and on-demand production of complex functional materials with desired composition, optical properties, and mechanical response.

36 MATERIALS SCIENCE↗

Beneficial Integration of Energy Storage and Load Management with Photovoltaic (PV)

In recent years, a number of industry activities have aimed at addressing the integration challenges posed by the variability and uncertainty of higher penetration of renewable generation sources, like solar photovoltaic (PV) – one of the key objectives of the Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) program launched by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). This EPRI led Beneficial Integration of Energy Storge, and Load Management with PV project aimed to design, develop, and demonstrate end-to-end distributed energy resource (DER) integration solution to build on these activities. EPRI led project team designed and implemented a local controller that uses model predictive control (MPC) algorithm to optimally manage DERs on site by planning for a receding horizon while executing the control settings for the first step of its plan. The team has also developed a system controller to interface with the local controller to demonstrate the hierarchical control and how it can leverage DER capabilities to address challenges like over voltage and thermal limit violations which typically limits the DER hosting capacity of distribution feeders. Team has demonstrated how the local controller with optimization algorithm can effectively manage controllable loads like HVAC, water heater, and pool pumps to allow for greater integration of PV with relatively smaller energy storage system requirements. Optimal utilization of the load control can also reduce the depth of discharge of batteries to meet grid export/import limit from behind-the-meter (BTM) DERs. Proper utilization of DER capabilities via local control intelligence, like the one developed and demonstrated in this project can help the industry to address integration challenges of higher penetration of solar PV in economically efficient manner. This can help to accelerate deployment of clean renewable energy systems at lower societal cost.

14 SOLAR ENERGY↗

Reverse and Forward Engineering of Local Voltage Control in Distribution Networks

The increasing penetration of renewable and distributed energy resources in distribution networks calls for real-time and distributed voltage control. As such, in this paper we investigate local Volt/VAR control with a general class of control functions, and show that the power system dynamics with non-incremental local voltage control can be seen as a distributed algorithm for solving a well-defined optimization problem (reverse engineering). The reverse engineering further reveals a fundamental limitation of the non-incremental voltage control: the convergence condition is restrictive and prevents better voltage regulation at equilibrium. This motivates us to design two incremental local voltage control schemes based on the subgradient and pseudo-gradient algorithms respectively for solving the same optimization problem (forward engineering). The new control schemes decouple the dynamical property from the equilibrium property, and have much less restrictive convergence conditions. This work presents another step towards developing a new foundation—network dynamics as optimization algorithms—for distributed real-time control and optimization of future power networks.

42 ENGINEERING↗

Constraints on OPF Surrogates for Learning Stable Local Volt/Var Controllers

We consider the problem of learning local Volt/Var controllers in distribution grids (DGs). Our approach starts from learning separable surrogates that take both local voltages and reactive powers as arguments and predict the reactive power setpoints that approximate optimal power flow (OPF) solutions. We propose an incremental control algorithm and identify two different sets of slope conditions on the local surrogates such that the network is collectively steered toward desired configurations asymptotically. Our results reveal the trade-offs between each set of conditions, with coupled voltage-power slope constraints allowing an arbitrary shape of surrogate functions but risking limitations on exploiting generation capabilities, and reactive power slope constraints taking full advantage of generation capabilities but constraining the shape of surrogate functions. AC power flow simulations on the IEEE 37-bus feeder illustrate their guaranteed stability properties and respective advantages in two DG scenarios.

asymptotic stability↗

A fuzzy controller with nonlinear control rules is the sum of a global nonlinear controller and a local nonlinear PI-like controller

The fuzzy controllers studied in this paper are the ones that employ N trapezoidal-shaped members for input fuzzy sets, Zadeh fuzzy logic and a centroid defuzzification algorithm for output fuzzy set. The author analytically proves that the structure of the fuzzy controllers is the sum of a global nonlinear controller and a local nonlinear proportional-integral-like controller. If N approaches infinity, the global controller becomes a nonlinear controller while the local controller disappears. If linear control rules are used, the global controller becomes a global two-dimensional multilevel relay which approaches a global linear proportional-integral (PI) controller as N approaches infinity.

Ying, Hao↗

Intensity-Modulated Radiation Therapy in Childhood Ependymoma

Purpose: To determine the patterns of failure after intensity-modulated radiation therapy (IMRT) for localized intracranial ependymoma. Methods and Materials: From 1994 to 2005, 22 children with pathologically proven, localized, intracranial ependymoma were treated with adjuvant IMRT. Of the patients, 12 (55%) had an infratentorial tumor and 14 (64%) had anaplastic histology. Five patients had a subtotal resection (STR), as evidenced by postoperative magnetic resonance imaging. The clinical target volume encompassed the tumor bed and any residual disease plus margin (median dose 54 Gy). Median follow-up for surviving patients was 39.8 months. Results: The 3-year overall survival rate was 87% {+-} 9%. The 3-year local control rate was 68% {+-} 12%. There were six local recurrences, all in the high-dose region of the treatment field. Median time to recurrence was 21.7 months. Of the 5 STR patients, 4 experienced recurrence and 3 died. Patients with a gross total resection had significantly better local control (p = 0.024) and overall survival (p = 0.008) than those with an STR. At last follow-up, no patient had developed visual loss, brain necrosis, myelitis, or a second malignancy. Conclusions: Treatment with IMRT provides local control and survival rates comparable with those in historic publications using larger treatment volumes. All failures were within the high-dose region, suggesting that IMRT does not diminish local control. The degree of surgical resection was shown to be significant for local control and survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Control circuits for asynchronous circuits

The described embodiments include a computing device with one or more asynchronous circuits and control circuits that control the operation of the asynchronous circuits. In some embodiments, the control circuits are arranged in a hierarchy with a top-level control circuit atop the hierarchy and one or more local control circuits lower in the hierarchy. In these embodiments, the top-level control circuit processes operating information for the one or more asynchronous circuits and/or other functional blocks in the computing device to determine an operating state for the computing device. Based on the operating state, the top-level control circuit communicates commands to the local control circuits to cause the local control circuits to operate in corresponding operating modes. Based on a corresponding operating mode command, each local control circuit sets one or more operating parameters for corresponding asynchronous circuits (and/or one or more other functional blocks).

42 ENGINEERING↗

Correlation of Local Failure With Measures of Dose Insufficiency in the High-Dose Single-Fraction Treatment of Bony Metastases

Purpose: In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials: The minimum doses received by the hottest 100%, 98%, and 95% (D{sub min}, D{sub 98}, and D{sub 95}) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18-24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12-14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results: With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV D{sub min}, D{sub 98}, and D{sub 95} for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for D{sub min}, D{sub 98}, and D{sub 95} were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions: The results indicate that D{sub min}, D{sub 98}, and D{sub 95} may be important risk factors for local failure. No local failures in any histology were observed when D{sub min} was >15 Gy, suggesting that this metric may be an important predictor of local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conservation Voltage Reduction (CVR) via Two-Timescale Control in Unbalanced Power Distribution Systems

Voltage control devices are employed in power distribution systems to reduce the power consumption by operating the system closer to the lower acceptable voltage limits; this technique is called conservation voltage reduction (CVR). The different modes of operation for system’s legacy devices (with binary control) and new devices (e.g. smart inverters with continuous control) coupled with variable photovoltaic (PV) generation results in voltage fluctuations which makes it challenging to achieve CVR objective. This paper presents a two-timescale control of feeder’s voltage control devices to achieve CVR that includes (1)a centralized controller operating in a slower time-scale to coordinate voltage control devices across the feeder and (2) local controllers operating in a faster timescale to mitigate voltage fluctuations due to PV variability. The centralized controller utilizes a three-phase optimal power flow model to obtain the decision variables for both legacy devices and smart inverters. The local controllers operate smart inverters to minimize voltage fluctuations and restore nodal voltages to their reference values by adjusting the reactive power support. The proposed approach is validated using the IEEE-123 bus (medium-size) and R3-12.47-2 (large-size) feeders. It is demonstrated that the proposed approach is effective in achieving the CVR objective for unbalanced distribution systems.

optimal control, distributed generation, fluctuati↗

Radiographic Local Tumor Control and Pain Palliation of Sarcoma Metastases within the Musculoskeletal System with Percutaneous Thermal Ablation

PurposeTo evaluate the effectiveness of percutaneous image-guided thermal ablation in achieving local tumor control and pain palliation of sarcoma metastases within the musculoskeletal system.Materials and MethodsRetrospective review of 64 sarcoma metastases within the musculoskeletal system in 26 women and 15 men (total = 41) treated with ablation between December 2011 and August 2016 was performed. Mean age of the cohort was 42.9 years ± 16.0 years. Two subgroups were treated: oligometastatic disease (n = 13) and widely metastatic disease (n = 51). A variety of sarcoma histologies were treated with average tumor volume of 42.5 cm{sup 3} (range 0.1–484.7 cm{sup 3}). Pain scores were recorded before and 4 weeks after therapy for 59% (38/64) of treated lesions. Follow-up imaging was evaluated for local control and to monitor sites of untreated disease as an internal control. Fifty-eight percent (37/64) were lost to imaging follow-up at varying time points over a year. Complication rate was 5% (3/64; one minor and two major events).ResultsOne-year local tumor control rates were 70% (19/27) in all patients, 67% (12/18) in the setting of progression of untreated metastases, and 100% (10/10) in the setting of oligometastatic disease. Median pain scores decreased from 8 (interquartile range 5.0–9.0) to 3 (interquartile range 0.1–4.0) 1 month after the procedure (P < 0.001).ConclusionImage-guided percutaneous ablation is an effective option for local tumor control and pain palliation of metastatic sarcomas within the musculoskeletal system. Treatment in the setting of oligometastatic disease offers potential for remission. Level of Evidence: Level 4, Retrospective Review.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of a Dose-Control Relationship for Lung and Liver Tumors After Stereotactic Body Radiation Therapy

Purpose: To determine prognostic factors for local control of primary or metastatic tumors within the lung or liver treated with stereotactic body radiation therapy (SBRT) within a single institution. Methods and Materials: The records of 141 consecutive patients with 246 lesions treated with three-fraction SBRT from Oct 1999 through Aug 2005 were reviewed. Local control was assessed radiographically. Univariate and multivariate analyses were performed to evaluate the influence of the following factors on local control: total dose, expressed as either nominal prescription dose or equivalent uniform dose (EUD); gross tumor volume; primary site; treatment site (lung vs. other); histologic characteristics (adenocarcinoma vs. other); gender; age; and primary vs. metastatic tumor. Results: On univariate analysis, increased dose (either nominal or EUD) and smaller gross tumor volume were significant predictors of higher local control. Lesions treated to a nominal dose of 54 Gy or greater had a 3-year actuarial local control rate of 89.3% compared with 59.0% and 8.1% for those treated to 36-53.9 Gy and less than 36 Gy. On multivariate analysis, only increased nominal dose and EUD retained statistical significance. Treatment was well tolerated; 5.7% of patients experienced Grade 3 or higher toxicity. Conclusions: This large single-institution series suggests a dose-control relationship within the range of SBRT doses applied. Excellent local control rates are achieved with a nominal dose of 54 Gy or greater, corresponding to an EUD greater than 65.3 Gy. These results support the use of aggressive SBRT regimens when durable tumor control is the primary objective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative Gain Monitoring of the GlueX Calorimeters

The relative gain of the photodetectors for the GlueX Barrel and Forward calorimeters will be monitored using modular LED driver systems. The BCAL system consists of a global controller that feeds power, bias voltage and trigger signals to 96 local controllers situated at the ends of the 48 BCAL modules, which drive 40 LEDs associated with the 40 light guides at the end of each module. The FCAL system consists also of a global controller, a local controller for each acrylic quadrant covering the face of the FCAL, and ten 4-LED pulser boards per local controller connected in a star configuration along the edges of the acrylic panes. The respective systems are currently being installed on the detectors and their tested performance is presented herein.

43 PARTICLE ACCELERATORS↗

Use of Concept of Chemotherapy-Equivalent Biologically Effective Dose to Provide Quantitative Evaluation of Contribution of Chemotherapy to Local Tumor Control in Chemoradiotherapy Cervical Cancer Trials

Purpose: To express the magnitude of the contribution of chemotherapy to local tumor control in chemoradiotherapy cervical cancer trials in terms of the concept of the biologically effective dose. Methods and Materials: The local control rates of both arms of each study (radiotherapy vs. radiotherapy plus chemotherapy) reported from randomized controlled trials of concurrent chemoradiotherapy for cervical cancer were reviewed and expressed using the Poisson model for tumor control probability (TCP) as TCP = exp(-exp E), where E is the logarithm of cell kill. By combining the two TCP values from each study, we calculated the chemotherapy-related log cell kill as Ec = ln[(lnTCP{sub Radiotherapy})/(lnTCP{sub Chemoradiotherapy})]. Assuming a range of radiosensitivities ({alpha} = 0.1-0.5 Gy{sup -1}) and taking the calculated log cell kill, we calculated the chemotherapy-BED, and using the linear quadratic model, the number of 2-Gy fractions corresponding to each BED. The effect of a range of tumor volumes and radiosensitivities ({alpha} Gy{sup -1}) on the TCP was also explored. Results: The chemotherapy-equivalent number of 2-Gy fractions range was 0.2-4 and was greater in tumors with lower radiosensitivity. In those tumors with intermediate radiosensitivity ({alpha} = 0.3 Gy{sup -1}), the equivalent number of 2-Gy fractions was 0.6-1.3, corresponding to 120-260 cGy of extra dose. The opportunities for clinically detectable improvement are only available in tumors with intermediate radiosensitivity with {alpha} = 0.22-0.28 Gy{sup -1}. The dependence of TCP on the tumor volume decreases as the radiosensitivity increases. Conclusion: The results of our study have shown that the contribution of chemotherapy to the TCP in cervical cancer is expected to be clinically detectable in larger and less-radiosensitive tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Learning Local Volt/VAR Controllers Toward Efficient Network Operation with Stability Guarantees: Preprint

This paper considers the problem of voltage regulation in distribution network. The primary motivation is to keep voltages within pre-assigned operating limits by commanding the reactive power output of distributed energy resources (DERs) deployed in the grid. We develop a framework for developing local Volt/Var control that comprises of two main steps. In the first, exploiting historical data and for each DER, we learn a function representing desirable equilibrium points for the power network. These points approximate solutions of an Optimal Power Flow problem. In the second, we propose a control scheme for steering the network towards these favorable configurations. Theoretical conditions are derived to formally guarantee the stability of the developed control scheme and numerical simulations illustrate the effectiveness of the proposed approach.

data-driven control↗

Local Recurrence After Complete Clinical Response and Watch and Wait in Rectal Cancer After Neoadjuvant Chemoradiation: Impact of Salvage Therapy on Local Disease Control

Purpose: To review the risk of local recurrence and impact of salvage therapy after Watch and Wait for rectal cancer with complete clinical response (cCR) after chemoradiation therapy (CRT). Methods and Materials: Patients with cT2-4N0-2M0 distal rectal cancer treated with CRT (50.4-54 Gy + 5-fluorouracil-based chemotherapy) and cCR at 8 weeks were included. Patients with cCR were enrolled in a strict follow-up program with no immediate surgery (Watch and Wait). Local recurrence-free survival was compared while taking into account Watch and Wait strategy alone and Watch and Wait plus salvage. Results: 90 of 183 patients experienced cCR at initial assessment after CRT (49%). When early tumor regrowths (up to and including the initial 12 months of follow-up) and late recurrences were considered together, 28 patients (31%) experienced local recurrence (median follow-up time, 60 months). Of those, 26 patients underwent salvage therapy, and 2 patients were not amenable to salvage. In 4 patients, local re-recurrence developed after Watch and Wait plus salvage. The overall salvage rate for local recurrence was 93%. Local recurrence-free survival at 5 years was 69% (all local recurrences) and 94% (after salvage procedures). Thirteen patients (14%) experienced systemic recurrence. The 5-year cancer-specific overall survival and disease-free survival for all patients (including all recurrences) were 91% and 68%, respectively. Conclusions: Local recurrence may develop in 31% of patients with initial cCR when early regrowths (≤12 months) and late recurrences are grouped together. More than half of these recurrences develop within 12 months of follow-up. Salvage therapy is possible in ≥90% of recurrences, leading to 94% local disease control, with 78% organ preservation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limited Margin Radiation Therapy for Children and Young Adults With Ewing Sarcoma Achieves High Rates of Local Tumor Control

Purpose: To determine the rate of local failure using focal conformal, limited margin radiation therapy (RT) and dose escalation for tumors ≥8 cm (greatest dimension at diagnosis) in children and young adults with Ewing sarcoma (EWS). Methods and Materials: Eligible patients with EWS were treated on a phase 2 institutional trial of focal conformal, limited margin RT using conformal or intensity modulated techniques. The treatment volume incorporated a 1-cm constrained margin around the gross tumor. Unresected tumors, <8 cm at diagnosis, received a standard dose of 55.8 Gy and tumors ≥8 cm, an escalated dose to 64.8 Gy. Patients with microscopic residual disease after resection received adjuvant RT to 50.4 Gy. Adjuvant brachytherapy was permitted in selected patients. Results: Forty-five patients were enrolled: 26 with localized and 19 with metastatic disease. Median (range) age, tumor size, and follow-up were 13.0 years (2.9-24.7 years), 9.0 cm (2.4-17.0 cm), and 54.5 months (1.9-122.2 months), respectively. All patients received systemic chemotherapy. The median (range) RT dose for all patients was 56.1 Gy (45-65.5 Gy). Seventeen patients received adjuvant, 16 standard-dose, and 12 escalated-dose RT. Failures included 1 local, 10 distant, and 1 local/distant. The estimated 10-year cumulative incidence of local failure was 4.4% ± 3.1%, with no statistical difference seen between RT treatment groups and no local failures in the escalated-dose RT treatment group. Conclusions: Treatment with focal conformal, limited margin RT, including dose escalation for larger tumors, provides favorable local tumor control in EWS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative Biological Effectiveness of Carbon Ions for Local Tumor Control of a Radioresistant Prostate Carcinoma in the Rat

Purpose: To study the relative biological effectiveness (RBE) of carbon ion beams relative to X-rays for local tumor control in a syngeneic rat prostate tumor (Dunning subline R3327-AT1). Methods and Materials: A total of 198 animals with tumors in the distal thigh were treated with increasing single and split doses of either {sup 12}C ions or photons using a 20-mm spread-out Bragg peak. Endpoints of the study were local control (no tumor recurrence within 300 days) and volumetric changes after irradiation. The resulting values for D{sub 50} (dose at 50% tumor control probability) were used to determine RBE values. Results: The D{sub 50} values for single doses were 32.9 {+-} 0.9 Gy for {sup 12}C ions and 75.7 {+-} 1.6 Gy for photons. The respective values for split doses were 38.0 {+-} 2.3 Gy and 90.6 {+-} 2.3 Gy. The corresponding RBE values were 2.30 {+-} 0.08 for single and 2.38 {+-} 0.16 for split doses. The most prominent side effects were dry and moist desquamation of the skin, which disappeared within weeks. Conclusion: The study confirmed the effectiveness of carbon ion therapy for severely radioresistant tumors. For 1- and 2-fraction photon and {sup 12}C ion radiation, we have established individual D{sub 50} values for local tumor control as well as related RBE values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Factors Affecting Locally Recurrent Rectal Cancer and Clinical Significance of Hemoglobin

Purpose: To investigate potential prognostic factors, including hemoglobin levels before and during radiotherapy, for associations with survival and local control in patients with unirradiated locally recurrent rectal cancer. Patients and Methods: Ten potential prognostic factors were investigated in 94 patients receiving radiotherapy for recurrent rectal cancer: age ({<=}68 vs. {>=}69 years), gender, Eastern Cooperative Oncology Group performance status (0-1 vs. 2-3), American Joint Committee on Cancer (AJCC) stage ({<=}II vs. III vs. IV), grading (G1-2 vs. G3), surgery, administration of chemotherapy, radiation dose (equivalent dose in 2-Gy fractions: {<=}50 vs. >50 Gy), and hemoglobin levels before (<12 vs. {>=}12 g/dL) and during (majority of levels: <12 vs. {>=}12 g/dL) radiotherapy. Multivariate analyses were performed, including hemoglobin levels, either before or during radiotherapy (not both) because these are confounding variables. Results: Improved survival was associated with better performance status (p < 0.001), lower AJCC stage (p = 0.023), surgery (p = 0.011), chemotherapy (p = 0.003), and hemoglobin levels {>=}12 g/dL both before (p = 0.031) and during (p < 0.001) radiotherapy. On multivariate analyses, performance status, AJCC stage, and hemoglobin levels during radiotherapy maintained significance. Improved local control was associated with better performance status (p = 0.040), lower AJCC stage (p = 0.010), lower grading (p = 0.012), surgery (p < 0.001), chemotherapy (p < 0.001), and hemoglobin levels {>=}12 g/dL before (p < 0.001) and during (p < 0.001) radiotherapy. On multivariate analyses, chemotherapy, grading, and hemoglobin levels before and during radiotherapy remained significant. Subgroup analyses of the patients having surgery demonstrated the extent of resection to be significantly associated with local control (p = 0.011) but not with survival (p = 0.45). Conclusion: Predictors for outcome in patients who received radiotherapy for locally recurrent rectal cancer were performance status, AJCC stage, chemotherapy, surgery, extent of resection, histologic grading, and hemoglobin levels both before and during radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗