Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Advanced Test Reactor Loop Activity Report: Gamma-Ray Emitting Radionuclides Concentrations and Decontamination Factors of ATR Loop Liquid Samples for ATR Cycle 175B-1

The gamma-ray emitting radionuclide concentration and decontamination factor results from gamma-ray spectrometry measurements of ATR loop liquid samples by the Radiation Measurements Laboratory (RML) are contained in this report for ATR Cycle 175B-1 from August 4, 2025 to October 6, 2025.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Test Reactor Loop Activity Report: Gamma-Ray Emitting Radionuclides Concentrations and Decontamination Factors of ATR Loop Liquid Samples Cycle 173C-1

The gamma-ray emitting radionuclide concentration and decontamination factor results from gamma-ray spectrometry measurements of ATR loop liquid samples by the Radiation Measurements Laboratory (RML) are contained in this report for ATR Cycle 173C-1 from November 22, 2024, to January 21, 2025.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scaling considerations for a multi-megawatt class supercritical CO2 brayton cycle and commercialization.

Small-scale supercritical CO2 demonstration loops are successful at identifying the important technical issues that one must face in order to scale up to larger power levels. The Sandia National Laboratories supercritical CO2 Brayton cycle test loops are identifying technical needs to scale the technology to commercial power levels such as 10 MWe. The small size of the Sandia 1 MWth loop has demonstration of the split flow loop efficiency and effectiveness of the Printed Circuit Heat Exchangers (PCHXs) leading to the design of a fully recuperated, split flow, supercritical CO2 Brayton cycle demonstration system. However, there were many problems that were encountered, such as high rotational speeds in the units. Additionally, the turbomachinery in the test loops need to identify issues concerning the bearings, seals, thermal boundaries, and motor controller problems in order to be proved a reliable power source in the 300 kWe range. Although these issues were anticipated in smaller demonstration units, commercially scaled hardware would eliminate these problems caused by high rotational speeds at small scale. The economic viability and development of the future scalable 10 MWe solely depends on the interest of DOE and private industry. The Intellectual Property collected by Sandia proves that the ~10 MWe supercritical CO2 power conversion loop to be very beneficial when coupled to a 20 MWth heat source (either solar, geothermal, fossil, or nuclear). This paper will identify a commercialization plan, as well as, a roadmap from the simple 1 MWth supercritical CO2 development loop to a power producing 10 MWe supercritical CO2 Brayton loop.

Fleming, Darryn D.↗

Testing Rod Seal Leakage of a 700 HP Reciprocating Compressor

Methane emissions from reciprocating compressors in the U.S. natural gas industry account for over 72.4 Bcf per year according to a 2006 statement by the United States Environmental Protection Agency. Methane also has a global warming potential 50 times greater than carbon monoxide. Reciprocating compressors are the machinery type with the highest contribution to methane emissions at natural gas transmissions stations. The largest contributing factor comes from the sealing components in the packing components around the piston rod. SwRI, therefore, designed and setup a test loop to perform baseline packing leakage measurements on a four stage 700 HP JGT/4 compressor. The goal was to improve upon current packing leakage models and to compare new seals vs. used seals. The test loop design is described including the limits of operation. The Data Acquisition System (DAQ), including data measurements, is also fully described. The project shows the results of the commissioning process that verified the operation of all the components. Once the loop was commissioned, SwRI performed baseline packing leakage for multiple pressure ratios on each of the four stages of the compressor. The data was collected to develop an analytical model of the packing leakage. Finally, similar testing was performed after replacing the typical rod seal packing with used packing. The used packing leakage was compared to the baseline packing leakage.

03 NATURAL GAS↗

Design of Modular Test Facility for Particle/sCO2 Heat Exchanger Evaluation

Heliogen has designed a 1.3 MW particle and supercritical carbon dioxide (sCO2) test loop to retire technical and manufacturing risks. The data from this facility will be used to validate near commercial-scale particle heat exchanger modules. The heat exchanger is scaled to capture all features of the full-scale modules. Testing will be conducted with CARBOBEAD HSP 16/30, a larger particle size than other recent testing. The system was designed to ASME codes with the constraint that sCO2 piping and other major components are stainless steels.

14 SOLAR ENERGY↗

Sensor Drift Estimation for Reactor Systems by Fusing Multiple Sensor Measurements

A nuclear power plant is instrumented with a variety of sensors that monitor its variables to estimate the state and initiate safety actions, if needed. We address the problem of estimating drifts or errors in sensor measurements due to factors such as calibration changes. We propose an information fusion method that uses measurements from other sensors to generate an estimate of a sensor measurement, and its difference from an actual measurement provides an error estimate. We present two fusers based on the ensemble of trees and support vector machine that are trained using sensor measurements collected at an emulated test loop of a pressurized water reactor under no-drift conditions. We present error estimates for a differential pressure sensor of the heat exchanger of the primary coolant system, under twenty controlled scenarios using the test loop. Both positive and negative errors are captured by both methods in scenarios involving calibration drifts, blocking, air gap and electromagnetic interference. The root mean square errors of estimated drifts are typically within 2% percent of the maximum.

Rao, Nageswara↗

Characterization of radiolytically generated degradation products in the strip section of a TRUEX flowsheet

This report presents a summary of the work performed to meet the FCRD level 2 milestone M3FT-13IN0302053, “Identification of TRUEX Strip Degradation.” The INL radiolysis test loop has been used to identify radiolytically generated degradation products in the strip section of the TRUEX flowsheet. These data were used to evaluate impact of the formation of radiolytic degradation products in the strip section upon the efficacy of the TRUEX flowsheet for the recovery of trivalent actinides and lanthanides from acidic solution. The nominal composition of the TRUEX solvent used in this study is 0.2 M CMPO and 1.4 M TBP dissolved in n-dodecane and the nominal composition of the TRUEX strip solution is 1.5 M lactic acid and 0.050 M diethylenetriaminepentaacetic acid. Gamma irradiation of a mixture of TRUEX process solvent and stripping solution in the test loop does not adversely impact flowsheet performance as measured by stripping americium ratios. The observed increase in americium stripping distribution ratios with increasing absorbed dose indicates the radiolytic production of organic soluble degradation compounds.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Does the three site Higgsless model survive the electroweak precision tests at loop?

We complete the list of one-loop renormalization group equations and matching conditions relevant for the computation of the electroweak precision parameters S and T in the three site Higgsless model. We obtain one-loop formulas for S and T expressed in terms of physical observables such as the Kaluza-Klein (KK) gauge boson mass M{sub W{sup '}}, the KK fermion mass M, and the KK gauge boson (W{sup '}) couplings with light quarks and leptons g{sub W{sup '}}{sub ff}. It is shown that these physical observables, M{sub W{sup '}}, M, and g{sub W{sup '}}{sub ff} are severely constrained by the electroweak precision data. Unlike the tree level analysis on the ideally delocalized fermion, we find that perfect fermiophobity of W{sup '} is ruled out by the precision data. We also study the cutoff dependence of our analysis. Although the model is nonrenormalizable, the dependence on the cutoff parameter {lambda} is shown to be nonsignificant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of an ATR Loop 2A Test Train: Phase 2 of the EPRI/INL Pilot Project for Irradiation of Alloys X-750 and XM-19

The Advanced Test Reactor National Scientific User Facility (ATR NSUF) and Electric Power Research Institute (EPRI) formed an agreement to test representative alloys used as reactor structural materials as a pilot program toward establishing guidelines for future ATR NSUF research programs. The pilot project is a three phase project consisting of baseline material characterization (Phase I), experiment design and irradiation thermal and neutronics analyses (Phase II), and post irradiation examination (Phase III). The intent of this Phase II portion of the pilot project is to estimate thermal and neutronic characteristics of the planned experiments and to provide design details of the experiment assemblies themselves. The materials chosen for this research are the nickel based super alloy X-750, and nitrogen strengthened austenitic stainless steel XM-19.

Source record↗

High-Temperature Split-Flow Recompression Brayton Cycle Initial Test Results

Supercritical CO 2 (S-CO 2 ) power plants offer the potential for better economics because of their small size, use of standard materials, and improved electrical power conversion efficiency at modest temperature (400–750°C). Sandia National Laboratories (SNL or Sandia) and the U.S. Department of Energy Office of Nuclear Energy (DOE-NE) are operating a supercritical CO 2 Brayton cycle power system—the Generation IV (Gen IV) split-flow S-CO 2 compressor test loop—currently located in Arvada Colorado, at Barber Nichols, Inc., under contract to Sandia. A photograph of the upgraded loop is shown in Figure E-1. This system is one of the first S-CO 2 power-producing Brayton cycles operating in the world. This report provides a summary of the newly installed hardware and briefly describes some of the test results that were performed in the upgraded split-flow Brayton loop during June and July of 2011. The Gen IV S-CO 2 split-flow Brayton loop was reconfigured to operate as a simple heated recuperated Brayton loop for the testing in this report period. The test loop had just concluded a phase of construction that substantially increased the capability of the loop by adding heaters, a high-temperature (HT) recuperator, more waste heat removal capability, high-power load banks, larger diameter piping with more bends to reduce thermal stress, and more capable scavenging pumps to reduce windage and friction within the turbomachinery and provide greater cooling capabilities. With these additions, the loop greatly increased its capacity for electrical power generation (30–80 kWe per generator, depending on the loop configuration) and its ability to reach high temperatures (up to 810 K [1000°F]). In recent weeks of testing, the test facility began to realize this potential by achieving new records in turbine inlet temperature (615 K [650°F]), shaft speed (52,000 rpm), pressure ratio (1.65), flow rate (2.7 kg/s), and electrical power generated (20 kWe). These operating conditions still remain short of design conditions for each turbine—an inlet temperature of 810 K (1000°F), a pressure ratio of 1.8, a shaft speed of 75,000 rpm, a flow rate of 3.5 kg/s, and a maximum generator power of 125 kWe—but they are beginning to be approached. Not all planned upgrades were implemented due to the limited funding profile of FY2010. Only 520 kW of heater power were installed—not the total 780 kW. Furthermore, because one of the heater controllers was not functioning, only 390 kW of heater power were available. Similarly, the 3-in. piping was installed only in the high-pressure leg of the loop, not in the low-pressure leg, as was originally planned. We also had to rely on the new load bank capability for rapid shutdown situations, and were not able to install a dedicated shutdown resistor. Nevertheless, in spite of these limitations, we operated the loop at record operating conditions and were largely limited only by the facility and support equipment—not the turbomachinery.

Wright, Steven Alan↗

Hardware-in-Loop Modules for Testing Automated Ventilator Controllers

Automated ventilator controllers have the potential to simplify oxygen and carbon dioxide management for trauma. In the pre-hospital or military medicine environment, trauma care can be required for prolonged periods by personnel with limited ventilator management training. As such, there is a need for closed-loop control systems that can adapt ventilator management to a complex, ever-changing medical environment. Here, we present a novel hardware-in-loop test platform for the independent troubleshooting and evaluation of oxygen and carbon dioxide automated ventilator management capabilities. The oxygen management system provides an analogue blood oxygen signal that is responsive to the fraction of inspired oxygen and the peak inspiratory pressure ventilator settings. A tested oxygenation controller successfully reached the target oxygen saturation within 5 min. The carbon dioxide removal system integrates with commercial ventilator technology and mimics carbon dioxide generation, lung compliance, and airway resistance while providing an end-tidal carbon dioxide level that is responsive to changes in the tidal volume and respiratory rate settings. A test mechanical ventilator controller was able to regulate EtCO2 regardless of the starting value within 10 min. This highlights the system’s functionality and provides proof-of-concept demonstrations for how the hardware-in-loop test platforms can be used for evaluating closed-loop controller technologies.

Berard, David (ORCID:0000000322863846)↗

Start-up Operation Experience with a Liquid Fluoride Salt Forced Convection Loop

A liquid fluoride salt forced convection test loop was constructed at Oak Ridge National Laboratory. Its unique features include a pebble bed test section, high-temperature instrumentation, a noncontact rotating gas seal for the pump, a silicon carbide flow tube, and a unique inductive heating technique. Initial startup and shake-down testing has been completed. This paper describes how several of the systems performed, highlights those that worked well, and discusses issues that arose during the start-up process. This discussion should be of interest to those who intend to develop molten salt technologies and who are interested in some of the specific techniques used in this experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydraulic Permeability of Resorcinol-Formaldehyde Resin

An ion exchange process using spherical resorcinol-formaldehyde (RF) resin is the baseline process for removing cesium from the dissolved salt solution in the high-level waste tanks at the Hanford Site, using large scale columns as part of the Waste Treatment Plant (WTP). The RF resin is also being evaluated for use in the proposed small column ion exchange (SCIX) system, which is an alternative treatment option at Hanford and at the Savannah River Site (SRS). A recirculating test loop with a small ion exchange column was used to measure the effect of oxygen uptake and radiation exposure on the permeability of a packed bed of the RF resin. The lab-scale column was designed to be prototypic of the proposed Hanford columns at the WTP. Although the test equipment was designed to model the Hanford ion exchange columns, the data on changes in the hydraulic permeability of the resin will also be valuable for determining potential pressure drops through the proposed SCIX system. The superficial fluid velocity in the lab-scale test (3.4-5.7 cm/s) was much higher than is planned for the full-scale Hanford columns to generate the maximum pressure drop expected in those columns (9.7 psig). The frictional drag from this high velocity produced forces on the resin in the lab-scale tests that matched the design basis of the full-scale Hanford column. Any changes in the resin caused by the radiation exposure and oxygen uptake were monitored by measuring the pressure drop through the lab-scale column and the physical properties of the resin. Three hydraulic test runs were completed, the first using fresh RF resin at 25 C, the second using irradiated resin at 25 C, and the third using irradiated resin at 45 C. A Hanford AP-101 simulant solution was recirculated through a test column containing 500 mL of Na-form RF resin. Known amounts of oxygen were introduced into the primary recirculation loop by saturating measured volumes of the simulant solution with oxygen and reintroducing the oxygenated simulant into the feed tank. The dissolved oxygen (DO) concentration of the recirculating simulant was monitored, and the amount of oxygen that reacted with the resin was determined from the change in the DO concentration of the recirculating simulant solution. Prior to hydraulic testing the resin for runs 2 and 3 was covered with the simulant solution and irradiated in a spent fuel element at the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Both batches of resin were irradiated to a total gamma dose of 177 Mrad, but the resin for run 2 reached a maximum temperature during irradiation of 51 C, while the resin for run 3 reached a temperature of 38 C. The different temperatures were the result of the operating status of HFIR at the time of the irradiation and were not part of the test plan; however, the results clearly show the impact of the higher-temperature exposure during irradiation. The flow rate and pressure drop data from the test loop runs show that irradiating the RF resin reduces both the void fraction and the permeability of the resin bed. The mechanism for the reduction in permeability is not clear because irradiation increases the particle size of the resin beads and makes them deform less under pressure. Microscopic examination of the resin beads shows that they are all smooth regular spheres and that irradiation or oxygen uptake did not change the shape of the beads. The resin reacts rapidly with DO in the simulant solution, and the reaction with oxygen reduces the permeability of a bed of new resin by about 10% but has less impact on the permeability of irradiated resin. Irradiation increases the toughness of the resin beads, probably by initiating cross-linking reactions in them. Oxygen uptake reduces the crush strength of both new and irradiated resin; however, the pressures that caused the beads to crush are much higher than would be expected during the operation of an ion exchange column. There was no visible evidence of broken beads in any of the resin samples taken from the test loop. Reaction with oxygen reduces the cesium distribution coefficient of the resin beads, as does irradiation. Higher temperatures during irradiation or during contact with the simulant solution further reduce the cesium distribution coefficient.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Materials Selection for the Lead-Bismuth Corrosion and Erosion Tests in DELTA Loop

This report documents the selection of materials participating in the currently ongoing corrosion/erosion tests in LANL Development of Lead-Alloy Technology and Applications (DELTA) loop, a facility designed to study the long-term corrosive effects of liquid lead-bismuth eutectic (LBE) on structural materials for high temperature applications in advanced reactors, accelerator-driven systems and spallation sources. In this suite of experiments, LBE temperature in the DELTA loop test section is 500°C. Oxygen sensors are used to maintain an LBE Oxygen concentration of 1x10 -6 to 1x10 -8 wt%. Unique to the experimental conditions is the LBE high flow-rate of 3-3.5 m/s in the test section. Results obtained in these corrosion tests represent a substantial extension from existing experimental data currently limited to LBE velocities of maximum ~2 m/s.

36 MATERIALS SCIENCE↗