Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of High-Temperature SiPM Noise

Introduction • Background: Silicon photomultipliers (SiPMs) are compact, low-power, and high-efficiency detectors that are increasingly used in radiation detection applications like medical imaging and nuclear safeguards. The have advantages of PMTs because they are smaller, operate at lower voltages, and offer high photon detection efficiency. • Challenges: SiPMs suffer from increased dark count rate (DCR) and optical crosstalk (OCT), which degrades performance. • Purpose of study: This study compares the Advansid ASD-NUV3S-P-40, Broadcom AFBR-S4K33C0147L, and Onsemi MicroFJ-30035-TSVTR under four different temperatures to compare their performance in harsh environments.

Fritchie, Jacob↗

Low-phase-noise surface-acoustic-wave oscillator using an edge mode of a phononic band gap

Low-phase-noise microwave-frequency integrated oscillators provide compact solutions for various applications in signal processing, communications, and sensing. Surface acoustic waves (SAWs), featuring orders-of-magnitude shorter wavelength than electromagnetic waves at the same frequency, enable integrated microwave-frequency systems with much smaller footprint on chip. SAW devices also allow higher-quality (Q) factors than electronic components at room temperature. Here, we demonstrate a low-phase-noise gigahertz-frequency SAW oscillator on 128°Y-cut lithium niobate, where the SAW resonator occupies a footprint of 0.05 mm 2 . Leveraging phononic crystal band-gap-edge modes to balance between Q factors and insertion losses, our 1-GHz SAW oscillator features a low phase noise of -132.5 dBc/Hz at a 10-kHz offset frequency and an overlapping Hadamard deviation of 6.5 × 10 -10 at an analysis time of 64 ms. The SAW resonator-based oscillator holds high potential in developing low-noise sensors and acousto-optic integrated circuits.

42 ENGINEERING↗

A cryogenic torsion balance using a liquid-cryogen free, ultra-low vibration cryostat

We describe a liquid-cryogen free cryostat with ultra-low vibration levels, which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. Here, the torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3–10 mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.

47 OTHER INSTRUMENTATION↗

Interferometric synthetic aperture microwave radiometry for the remote sensing of the earth

Interferometric aperture synthesis is presented as an alternative to real aperture measurements of the earth's brightness temperature from low earth orbit. The signal-to-noise performance of a single interferometric measurement is considered, and the noise characteristics of the brightness temperature image produced from the interferometer measurements are discussed. The sampling requirements of the measurements and the resulting effects of the noise in the measurements on the image are described. The specific case of the electronically steered thinned array radiometer (ESTAR) currently under construction is examined. The ESTAR prototype is described in detail sufficient to permit a performance evaluation of its spatial and temperature resolution. Critical aspects of an extension of the ESTAR sensor to a larger spaceborne system are considered. Of particular importance are the number and placement of antenna elements in the imaging array. A comparison of the implementation methodologies of radio astronomy and earth remote sensing is presented along with the effects of the source brightness distribution, the antenna array configuration and the method used for array scanning.

Ruf, Christopher S.↗

Quasiparticle Generation-Recombination Noise in the Limit of Low Detector Volume

We have measured the quasiparticle generation-recombination (GR) noise in aluminium lumped element kinetic inductors with a wide range of detector volumes at various temperatures. The basic detector consists of meandering inductor and interdigitated capacitor fingers. The inductor volume is varied from 2 to 153 mu m(3) by changing the inductor width and length to maintain a constant inductance. We started with measuring the power spectrum density (PSD) of the detectors frequency noise which is a function of GR noise and we clearly observed the spectrum roll off at 10 kHz which corresponds to the quasiparticle lifetime. Using data from a temperature sweep of the resonator frequency we convert the frequency fluctuation to quasiparticle fluctuation and observe its strong dependence on detector volume: detectors with smaller volume display less quasiparticle noise amplitude. Meanwhile we observe a saturated quasiparticle density at low temperature from all detectors as the quasiparticle life time tqp approaches a constant value at low temperature.

Li, Juliang↗

Low Noise Amplifiers and Receivers for Remote Sensing

The study of atmospheric dynamics and climatology depend on accurate and frequent measurements of temperature and humidity profiles of the atmosphere. These measurements furthermore enable highly accurate measurements of ocean topography by providing total column water vapour data for radar path delay correction. The atmospheric temperature profile is characterised at the oxygen molecule absorption frequencies (60 and 118 GHz) and the humidity profile at the water molecule absorption frequencies (23 and 183 GHz). Total column measurements can be achieved by comparing measured radiometric temperatures at atmospheric window channels, such as 90, 130 and 166 GHz. The standard receiver technology for these frequencies was diode mixers with MMIC LNAs being applied at the lower frequencies. The sensitivity of millimetre wave receivers improved significantly with the introduction of the low noise 35 nm gate length InP MMIC amplifiers. We currently achieve 3 dB noise figure at 180 GHz and 2 dB noise figure at 90 GHz with our MMIC low noise amplifiers (LNAs) in room temperature. These amplifiers and the receivers we have built using them made it possible to conduct highly accurate airborne measurement campaigns from the Global Hawk unmanned aerial vehicle, develop millimeter wave internally calibrated radiometers for altimeter radar path delay correction, and build prototypes of large arrays of millimeter receivers for a geostationary interferometric sounder. We use the developed millimeter wave receivers to measure temperature and humidity profiles in the atmosphere and in hurricanes as well as to characterize the path delay error in ocean topography altimetry.

low noise amplifier↗

Strut Shaping of 34m Beam Waveguide Antenna for Reductions in Near-Field RF and Noise Temeperature

Struts shaping of the NASA's Deep Space Network (DSN) 34m Beam Waveguide (BWG) antenna has been implemented to reduce near-field RF exposure while improving the antenna noise temperature. Strut shaping was achieved by introducing an RF shield that does not compromise the structural integrity of the existing structure. Reduction in the RF near-field exposure will compensate for the planned transmit power increase of the antenna from 20 kW to 80 kW while satisfying safety requirements for RF exposure. Antenna noise temperature was also improved by as much as 1.5 K for the low elevation angles and 0.5 K in other areas. Both reductions of RF near-field exposure and antenna noise temperature were verified through measurements and agree very well with calculated results.

reflector↗

IRSN Work in Support of NCSP: FY2021 and Plan for Future [Slides]

IRSN and NCSP collaboration has been very fruitful. Despite challenges presented by COVID-19, work has been performed regularly and successfully by video conference. This includes monthly basis meeting with LLNL and LANL and specifics meetings with ORNL and SNL when needed. After two years without any IRSN participation to experiments, ISRN is looking forward to fully participating in the three proposed integral experiments scheduled in 2022. IRSN is working on several new projects including TEX-MOX and TEX-low temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Is the red arc a good indicator of ionosphere-magnetosphere conditions

Weak red arcs were observed on the two consecutive nights of July 12-13 and July 13-14, 1969, at Richland, Washington, whereas no red arcs were detectable on the nights preceding and following the observations. Satellite (Ogo 6) data of electron temperature and density, low-frequency ac electric field, and suprathermal electron flux corresponding to the conjugate region of Richland show no significant variations during these days. The data show elevated electron temperatures and enhanced low-frequency ac noise levels at the expected red arc position in the neighborhood of the density trough, as indicated by previous observations. The data appear to indicate that the optical criterion of red arc occurrence would lead to the conclusion of significantly different ionosphere-magnetosphere conditions during these four nights, whereas the more detailed in situ data show that the conditions were very similar.

Nagy, A. F.↗

Adaptive multibeam phased array design for a Spacelab experiment

The parametric tradeoff analyses and design for an Adaptive Multibeam Phased Array (AMPA) for a Spacelab experiment are described. This AMPA Experiment System was designed with particular emphasis to maximize channel capacity and minimize implementation and cost impacts for future austere maritime and aeronautical users, operating with a low gain hemispherical coverage antenna element, low effective radiated power, and low antenna gain-to-system noise temperature ratio.

Noji, T. T.↗

Variable stream control engine for advanced supersonic aircraft design update

The updating of the engine concept for a second-generation supersonic transport, the variable stream control engine (VSCE), in terms of mechanical design definition and estimated performance is discussed. The design definition reflects technology advancements that improve system efficiency, durability and environments were established. The components unique to the VSCE concept, a high performance duct burner and a low noise coannular nozzle, and the high temperature components are identified as critical technologies. Technology advances for the high temperature components (main combustor and turbines) are also discussed. To address the requirements in this area, the technical approach for undertaking a high temperature validation program is defined. The multi-phased effort would include assorted rig and laboratory tests, then culminate with the demonstration of a flight-type main combustor and single-stage high pressure turbine at operating conditions envisioned for a VSCE.

Hunt, R. B.↗

An 8.4-GHz cryogenically cooled HEMT amplifier for DSS 13

A prototype 8.4 GHz (X-band) high electron mobility transistor (HEMT) amplifier/closed cycle refrigerator system was installed in the Deep Space Station 13 feedcone in August 1987. The amplifier is cryogenically cooled to a physical temperature of 12 K and provides 31 K antenna noise temperature (zenith) and 35 dB of gain at a frequency of 8.2 to 8.6 GHz. Antenna system noise temperature is less than 50 K from 7.2 to 9.4 MHz. The low noise HEMT amplifier system is intended for use as a radio astronomy or space communications receiver front end.

Tanida, L.↗

15 cut-off 128x128 Quantum Well Infrared Photodetectors (QWIPS) Camera

We discuss the development and the performance of a very long wavelength (13.5 - 15 128x128 AlGaAs/GaAs multiquantum well infrared imaging system. Highly uniform, high-yield QWIP focal plane array was hybridized to a CMOS multiplexer operating in a direct injection mode. For efficient light coupling an integral random scattering reflector (Random Grating) was incorporated. Due to the high uniformity, excellent imagery, low noise as well as a noise equivalent temperature difference (NE T) of less than 30 mK were obtained when operating around 45 K. Therefore, high image contrast signal to noise ratio has been achieved.

128x128 Photodetectors↗

Superconducting Detector Arrays for Astrophysics

The next generation of astrophysics instruments will feature an order of magnitude more photon sensors or sensors that have an order of magnitude greater sensitivity. Since detector noise scales with temperature, a number of candidate technologies have been developed that use the intrinsic advantages of detector systems that operate below 1 Kelvin. Many of these systems employ of the superconducting phenomena that occur in metals at these temperatures to build ultrasensitive detectors and low-noise, low-power readout architectures. I will present one such system in use today to meet the needs of the astrophysics community at millimeter and x-ray wavelengths. Our group at NASA in collaboration with Princeton, NIST, Boulder and a number of other groups is building large format arrays of superconducting transition edge sensors (TES) read out with multiplexed superconducting quantum interference devices (SQUID). I will present the high sensitivity we have achieved in multiplexed x-ray sensors with the TES technology and describe the construction of a 1000-sensor TES/SQUID array for microwave measurements. With our collaboration's deployment of a kilopixel TES array for 2 mm radiation at the Atacarna Cosmology Telescope in November 2007, we have first images of the lensed Cosmic Microwave Background at fine angular scales.

Chervenak, James↗

Monolithic silicon bolometers

A new type of bolometer detector for the millimeter and submillimeter spectral range is described. The bolometer is constructed of silicon using integrated circuit fabrication techniques. Ion implantation is used to give controlled resistance vs temperature properties as well as extremely low 1/f noise contacts. The devices have been tested between 4.2 and 0.3 K. The best electrical NEP measured is 4 x 10 to the -16th W/Hz to the 1/2 at 0.35 K between 1- and 10-Hz modulation frequency. This device had a detecting area of 0.25 sq cm and a time constant of 20 msec at a bath temperature of 0.35 K.

Downey, P. M.↗

IceCube Sensitivity for Low-Energy Neutrinos from Nearby Supernovae

This paper describes the response of the IceCube neutrino telescope located at the geographic South Pole to outbursts of MeV neutrinos from the core collapse of nearby massive stars. IceCube was completed in December 2010 forming a lattice of 5160 photomultiplier tubes that monitor a volume of approx. 1 cu km in the deep Antarctic ice for particle induced photons. The telescope was designed to detect neutrinos with energies greater than 100 GeV. Owing to subfreezing ice temperatures, the photomultiplier dark noise rates are particularly low. Hence IceCube can also detect large numbers of MeV neutrinos by observing a collective rise in all photomultiplier rates on top of the dark noise. With 2 ms timing resolution, IceCube can detect subtle features in the temporal development of the supernova neutrino burst. For a supernova at the galactic center, its sensitivity matches that of a background-free megaton-scale supernova search experiment. The sensitivity decreases to 20 standard deviations at the galactic edge (30 kpc) and 6 standard deviations at the Large Magellanic Cloud (50 kpc). IceCube is sending triggers from potential supernovae to the Supernova Early Warning System. The sensitivity to neutrino properties such as the neutrino hierarchy is discussed, as well as the possibility to detect the neutronization burst, a short outbreak's released by electron capture on protons soon after collapse. Tantalizing signatures, such as the formation of a quark star or a black hole as well as the characteristics of shock waves, are investigated to illustrate IceCube's capability for supernova detection.

Stamatikos, M.↗

A New ERA in Global Temperature Monitoring with the Advanced Microwave Sounding Unit (AMSU)

The launch of the first Advanced Microwave Sounding Unit (AMSU) on the NOAA-15 spacecraft on 13 May 1998 marked a significant advance in our ability to monitor global temperatures. Compared to the Microwave Sounding Units (MSU) flying since 1978 on the TIROS-N series of NOAA polar orbiters, the AMSU offers better horizontal, vertical, and radiometric resolutions. It will allow routine monitoring of 1 1 (mostly) separate layers, compared to 2 or 3 with the MSU, including layers in the middle and upper stratosphere (2.5 hPa) where increasing carbon dioxide concentrations should be causing a cooling rate of about 1 deg. C per decade. More precise limb corrections combined with low noise will allow identification of subtle spatial temperature patterns associated with global cyclone activity.

Spencer, Roy W.↗