Search NASA⌕ Search

SEARCH · Search NASA

Results for “lumped parameter model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neural lumped parameter differential equations with application in friction-stir processing

Lumped parameter methods aim to simplify the evolution of spatially-extended or continuous physical systems to that of a “lumped” element representative of the physical scales of the modeled system. For systems where the definition of a lumped element or its associated physics may be unknown, modeling tasks may be restricted to full-fidelity physics simulations. Here, in this work, we consider data-driven modeling tasks with limited point-wise measurements of otherwise continuous systems. We build upon the notion of the Universal Differential Equation (UDE) to construct data-driven models for reducing dynamics to that of a lumped parameter and inferring its properties. The flexibility of UDEs allow for composing various known physical priors suitable for application-specific modeling tasks, including lumped parameter methods. The motivating example for this work is the plunge and dwell stages for friction-stir welding; specifically, (i) mapping power input into the tool to a point-measurement of temperature and (ii) using this learned mapping for process control.

97 MATHEMATICS AND COMPUTING↗

Controlling flexible structures with second order actuator dynamics

The control of flexible structures for those systems with actuators that are modeled by second order dynamics is examined. Two modeling approaches are investigated. First a stability and performance analysis is performed using a low order finite dimensional model of the structure. Secondly, a continuum model of the flexible structure to be controlled, coupled with lumped parameter second order dynamic models of the actuators performing the control is used. This model is appropriate in the modeling of the control of a flexible panel by proof-mass actuators as well as other beam, plate and shell like structural numbers. The model is verified with experimental measurements.

Inman, Daniel J.↗

On the inclusion principle and spillover effect in the identification of distributed structures

Distributed structures are Distributed-Parameter Systems (DPS) and must be modeled by large-dimensional systems. Practical limitations require that only a subset of the modes be actively controlled. Control of the residual (uncontrolled) modes is known as control spillover, and it can degrade the system performance. The contamination of the sensor signals by the residual modes is known as observation spillover and it can destabilize the system. An analogous effect exists in the identification problem. Distributed structures must be represented by discretized (finite-dimensional) models or lumped-parameter systems. The contamination of the measurements by the residual (unmodeled) modes is referred to as identification spillover, and it is the object of this study. To study the effects of identification spillover, we use a variational formulation to obtain the natural frequencies and mode shapes. This formulation has direct application to DPS. The identification technique consists of finding the stationary values of a pseudo-Rayleigh quotient.

Norris, Mark. A.↗

Development of an object-oriented dynamics simulator for a LFR DEMO

A control-oriented dynamics simulator for a Generation IV Lead-cooled Fast Reactor (LFR) demonstrator (DEMO) has been developed aimed at providing a flexible, simple and fast-running tool allowing to perform design-basis transient and stability analyses, and to lay the foundations for the study of the system control strategy. For such purposes, a model representing a compromise between accuracy and straightforwardness has been necessarily sought, and in this view an object-oriented approach based on the Modelica language has been adopted. The reactor primary and secondary systems have been implemented by assembling both component models already available in a specific thermal-hydraulic library, and ad hoc developed nuclear component models suitably modified according to the specific DEMO configuration. The resulting overall plant simulator, incorporating also the balance of plant, consists in the following essential parts: core, integrated steam generator/primary pump block, cold and hot legs, primary coolant cold pool, turbine, heat sink, secondary coolant pump. Afterwards, the reactor response to typical transient initiators has been investigated: feedwater mass flow rate and temperature enhancement, turbine admission valve coefficient variation, increase of primary coolant mass flow rate, and transient of overpower have been simulated; results have been compared with the outcomes of analogous analyses performed by employing a lumped-parameter DEMO plant model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal analytic model of 30 cm engineering model mercury ion thruster

A lumped parameter thermal nodal network was developed for a 30 cm Engineering Model Mercury Ion Thruster. The network consists of approximately 100 nodes coded in SINDA format for use on the Univac 1106/1108 computer. This model takes into account internal dissipation, radiation, and conduction as well as environmental heating. A series of tests were performed to simulate a wide range of thermal environments on an operating 30 cm thruster, instrumented to measure the temperature distribution within the thruster. The results of these tests were used to calibrate the analytical model. The analytical model along with comparisons between analytical and experimental results for the various operating conditions are presented.

Oglebay, J. C.↗

High-Throughput Microfluidics Platform for Intracellular Delivery and Sampling of Biomolecules from Live Cells

Nondestructive cell membrane permeabilization systems enable the intracellular delivery of exogenous biomolecules for cell engineering tasks as well as the temporal sampling of cytosolic contents from live cells for the analysis of dynamic processes. Here, in this paper, we report a microwell array format live-cell analysis device (LCAD) that can perform localized-electroporation induced membrane permeabilization, for cellular delivery or sampling, and directly interfaces with surface-based biosensors for analyzing the extracted contents. We demonstrate the capabilities of the LCAD via an automated high-throughput workflow for multimodal analysis of live-cell dynamics, consisting of quantitative measurements of enzyme activity using self-assembled monolayers for MALDI mass spectrometry (SAMDI) and deep-learning enhanced imaging and analysis. By combining a fabrication protocol that enables robust assembly and operation of multilayer devices with embedded gold electrodes and an automated imaging workflow, we successfully deliver functional molecules (plasmid and siRNA) into live cells at multiple time-points and track their effect on gene expression and cell morphology temporally. Furthermore, we report sampling performance enhancements, achieving saturation levels of protein tyrosine phosphatase activity measured from as few as 60 cells, and demonstrate control over the amount of sampled contents by optimization of electroporation parameters using a lumped model. Lastly, we investigate the implications of cell morphology on electroporation-induced sampling of fluorescent molecules using a deep-learning enhanced image analysis workflow.

59 BASIC BIOLOGICAL SCIENCES↗

An experimental investigation of mesospheric ionization

Mesospheric ionization and its variability are examined. Data were obtained primarily by the parachute-borne blunt probe technique conducted in coordinated rocket experiments at White Sands Missile Range, New Mexico and Wallops Island, Virginia. Electrical conductivity measurements and deduced charge density values from ten rocket launches are presented and discussed. Positive ion conductivity and electron density were found to be relatively invariant with height between 45 and 60 km. Variations in positive conductivity of a factor of two and enhancements in negative conductivity by as much as a factor of four were measured by the blunt probe. A simple lumped parameter ion chemistry model is shown to satisfactorily explain the charge density values for the undisturbed lower D-region. Implications of the data in terms of this model are considered. The principal loss mechanism for positive ions in the 45 to 60 km. region is concluded to be dissociative recombination. Electron densities deduced from the conductivity data are explained by detachment involving a minor neutral constituent which is mixed between 65 and 45 km. and then cuts off sharply below 45 km. A correlation study involving blunt probe measurements shows relatively good agreement between variations in positive conductivity and temperature.

Mitchell, J. D.↗

Technique for predicting high-frequency stability characteristics of gaseous-propellant combustors

A technique for predicting the stability characteristics of a gaseous-propellant rocket combustion system is developed based on a model that assumes coupling between the flow through the injector and the oscillating chamber pressure. The theoretical model uses a lumped parameter approach for the flow elements in the injection system plus wave dynamics in the combustion chamber. The injector flow oscillations are coupled to the chamber pressure oscillations with a delay time. Frequency and decay (or growth) rates are calculated for various combustor design and operating parameters to demonstrate the influence of various parameters on stability. Changes in oxidizer design parameters had a much larger influence on stability than a similar change in fuel parameters. A complete description of the computer program used to make these calculations is given in an appendix.

Priem, R. J.↗

Spacecraft thermal environments.

Definitions are given for spacecraft-surface thermal environment characteristics. Lumped-parameter thermal network modeling techniques are derived for spacecraft thermal environment analysis. The application of these techniques to thermal/vacuum testing is described. A major computer program required by these techniques is outlined. It is noted that this approach has been used to determine thermal environments for the Skylab ATM.

Chapter, J. J.↗

Systems improved numerical differencing analyzer

Program solves physical problems governed by diffusion-type equations, provided that equations can be modeled by lumped-parameter representation. Program is used for thermal analysis, and could be adapted to solve Fourier, Poisson, and Laplace differential equations. Program is in FORTRAN IV and Assembler for execution on UNIVAC 1100-series or CYBER 175.

Source record↗

Temperature control of silica mirrors for cryogenically-cooled telescopes in space

The SIRTF (Space Infrared Telescope Facility) optical subsystem, including the primary mirror, has been modeled using lumped-parameter techniques and a thermal and cryogenic transient analysis program developed previously. Since silica mirrors have been shown to have significantly less distortion due to cryogenic cooldown, a silica primary mirror of approximately 1 m diameter is being considered. Thermal responses to variations in aperture heat load and heat sink temperature have been explored. Calculations have been made of system noise components from primary mirror spatial and temporal temperature variations. Background-limited infrared observations can be made at wavelengths out to 200 micrometers. Mirror thermal performance with and without copper wires for cooling is also considered.

Melugin, R. K.↗

SINDA - Systems Improved Numerical Differencing Analyzer

Capability to model fluid flow added. SINDA is software system developed to solve physical problems governed by diffusion-type equations mathematically modeled by lumped-parameter representations. Used as general thermal analyzer with resistor-and-capacitor-network representations. Adapted to wide range of problems represented by Fourier, Possion, Laplace, or other differential equations. Written in FORTRAN and Assembler.

Damico, Steve J.↗

SINDA '85/FLUINT, Version 2.2

SINDA, Systems Improved Numerical Differencing Analyzer, software system developed for solving physical problems governed by diffusion-type equations modeled by lumped-parameter representations. Used as general thermal analyzer with resistor-and-capacitor-network representations, adapted to wide range of problems represented by such differential equations as Fourier, Poisson, or LaPlace. Software system updated. FLUINT, FLUid INTegrator, is advanced, one-dimensional fluid-analysis program solving equations of arbitrary fluid-flow networks. Written in FORTRAN and ASSEMBLER.

Cullimore, Brent↗

Observations on Rotating Cavitation and Cavitation Surge from the Development of the Fastrac Engine Turbopump

Observations regarding rotating cavitation and cavitation surge experienced during the development of the Fastrac engine turbopump are discussed. Detailed observations acquired from the analysis of both water flow and liquid oxygen test data are offered in this paper. Scaling and general comparison of rotating cavitation between water flow and liquid oxygen testing are discussed. Complex data features linking the localized rotating cavitation mechanism of the inducer to system surge components are described in detail. Finally a description of a lumped-parameter hydraulic system model developed to better understand observed data is given.

Zoladz, Thomas F.↗

Overview of Rotating Cavitation and Cavitation Surge in the Fastrac Engine LOX Turbopump

Observations regarding rotating cavitation and cavitation surge experienced during the development of the Fastrac 60 Klbf engine turbopump are discussed. Detailed observations from the analysis of both water flow and liquid oxygen test data are offered. Scaling and general comparison of rotating cavitation between water flow and liquid oxygen testing are discussed. Complex data features linking the localized rotating cavitation mechanism of the inducer to system surge components are described in detail. Finally a description of a simple lumped-parameter hydraulic system model developed to better understand observed data is given.

Zoladz, Thomas↗

Development of a hydraulic model of the human systemic circulation

Physical and numeric models of the human circulation are constructed for a number of objectives, including studies and training in physiologic control, interpretation of clinical observations, and testing of prosthetic cardiovascular devices. For many of these purposes it is important to quantitatively validate the dynamic response of the models in terms of the input impedance (Z = oscillatory pressure/oscillatory flow). To address this need, the authors developed an improved physical model. Using a computer study, the authors first identified the configuration of lumped parameter elements in a model of the systemic circulation; the result was a good match with human aortic input impedance with a minimum number of elements. Design, construction, and testing of a hydraulic model analogous to the computer model followed. Numeric results showed that a three element model with two resistors and one compliance produced reasonable matching without undue complication. The subsequent analogous hydraulic model included adjustable resistors incorporating a sliding plate to vary the flow area through a porous material and an adjustable compliance consisting of a variable-volume air chamber. The response of the hydraulic model compared favorably with other circulation models.

NASA Program Biomedical Research and Countermeasur↗

Dynamic Analysis of Wind Turbine Planetary Gears Using an Extended Harmonic Balance Approach: Preprint

The dynamics of wind turbine planetary gears with gravity effects are investigated using an extended harmonic balance method that extends established harmonic balance formulations to include simultaneous internal and external excitations. The extended harmonic balance method with arc-length continuation and Floquet theory is applied to a lumped-parameter planetary gear model including gravity,fluctuating mesh stiffness, bearing clearance, and nonlinear tooth contact to obtain the planetary gear dynamic response. The calculated responses compare well with time domain integrated mathematical models and experimental results. Gravity is a fundamental vibration source in wind turbine planetary gears and plays an important role in system dynamics, causing hardening effects induced by toothwedging and bearing-raceway contacts. Bearing clearance significantly reduces the lowest resonant frequencies of translational modes. Gravity and bearing clearance together lowers the speed at which tooth wedging occurs lower than the resonant frequency.