Deflection Analysis of the Space Shuttle External Tank Door Drive Mechanism

Upon observing an abnormal closure of the Space Shuttle s External Tank Doors (ETD), a dynamic model was created in MSC/ADAMS to conduct deflection analyses of the Door Drive Mechanism (DDM). For a similar analysis, the traditional approach would be to construct a full finite element model of the mechanism. The purpose of this paper is to describe an alternative approach that models the flexibility of the DDM using a lumped parameter approximation to capture the compliance of individual parts within the drive linkage. This approach allows for rapid construction of a dynamic model in a time-critical setting, while still retaining the appropriate equivalent stiffness of each linkage component. As a validation of these equivalent stiffnesses, finite element analysis (FEA) was used to iteratively update the model towards convergence. Following this analysis, deflections recovered from the dynamic model can be used to calculate stress and classify each component s deformation as either elastic or plastic. Based on the modeling assumptions used in this analysis and the maximum input forcing condition, two components in the DDM show a factor of safety less than or equal to 0.5. However, to accurately evaluate the induced stresses, additional mechanism rigging information would be necessary to characterize the input forcing conditions. This information would also allow for the classification of stresses as either elastic or plastic.

Tosto, Michael A.↗

Calculation of atmospheric loss from microwave radiometric noise temperature measurements

Microwave propagation loss in the atmosphere can be inferred from microwave radiometric noise temperature measurements. The relevant equations are given and a derivation and calculation is made assuming various physical models. Comparison is made with the commonly used lumped element atmospheric model (isothermal and uniform loss) and the model with linear temperature and exponential loss distributions. The results are useful for estimating the integral inversion differences due to the model selection. This indicates that the commonly used lumped element atmospheric model is a very good approximation with judicious choice of the effective physical temperature. For the worst case comparison, the lumped element model agrees with the variable parameter model within 0.2 dB up to a propagation loss of 3 dB.

Stelzried, C.↗

Microwave characterization and modeling of GaAs/AlGaAs heterojunction bipolar transistors

The characterization and modeling of a microwave GaAs/AlGaAs heterojunction Bipolar Transistor (HBT) are discussed. The de-embedded scattering parameters are used to derive a small signal lumped element equivalent circuit model using EEsof's Touchstone software package. Each element in the equivalent circuit model is shown to have its origin within the device. The model shows good agreement between the measured and modeled scattering parameters over a wide range of bias currents. Further, the MAG (maximum available power gain) and the h sub 21 (current gain) calculated from the measured data and those predicted by the model are also in good agreement. Consequently, the model should also be capable of predicting the f sub max and the f sub T of other HBTs.

Simons, Rainee N.↗

Analytical model of an Annular Momentum Control Device (AMCD) laboratory test model magnetic bearing actuator

An analytical model of an Annular Momentum Control Device (AMCD) laboratory test model magnetic bearing actuator with permanent magnet fluxbiasing is presented. An AMCD consists of a spinning annular rim which is suspended by a noncontacting linear electromagnetic spin motor. The actuator is treated as a lumped-parameter electromechanical system in the development of the model.

Groom, N. J.↗

Temperature Stratification in a Cryogenic Fuel Tank

A reduced dynamical model describing temperature stratification effects driven by natural convection in a liquid hydrogen cryogenic fuel tank has been developed. It accounts for cryogenic propellant loading, storage, and unloading in the conditions of normal, increased, and micro- gravity. The model involves multiple horizontal control volumes in both liquid and ullage spaces. Temperature and velocity boundary layers at the tank walls are taken into account by using correlation relations. Heat exchange involving the tank wall is considered by means of the lumped-parameter method. By employing basic conservation laws, the model takes into consideration the major multi-phase mass and energy exchange processes involved, such as condensation-evaporation of the hydrogen, as well as flows of hydrogen liquid and vapor in the presence of pressurizing helium gas. The model involves a liquid hydrogen feed line and a tank ullage vent valve for pressure control. The temperature stratification effects are investigated, including in the presence of vent valve oscillations. A simulation of temperature stratification effects in a generic cryogenic tank has been implemented in Matlab and results are presented for various tank conditions.

stratification↗

Simulation of Non-Acoustic Combustion Instability in a Hybrid Rocket Motor

A transient model of a hybrid motor was formulated to study the cause and elimination of non-acoustic combustion instability. The transient model was used to simulate four key tests out of a series of seventeen hybrid motor tests conducted by Thiokol, Rocketdyne and Martin Marietta at NASA/Marshall Space Flight Center (NASA/MSFC). These tests were performed under the Hybrid Propulsion Technology for Launch Vehicle Boosters (HPTLVB) program. The first test resulted in stable combustion. The second test resulted in large-amplitude, 6.5 Hz chamber pressure oscillations that gradually damped away by the end of the test. The third test resulted in large-amplitude, 7.5 Hz chamber pressure oscillations that were sustained throughout the test. The seventh test resulted in the elimination of combustion instability with the installation of an orifice immediately upstream of the injector. The formulation and implementation of the model are the scope of this presentation. The current model is an independent continuation of modeling presented previously by joint Thiokol-Rocketdyne collaborators Boardman, Hawkins, Wassom, and Claflin. The previous model simulated an unstable IR&D hybrid motor test performed by Thiokol. There was very good agreement between the model and the test data. Like the previous model, the current model was developed using Matrix-x simulation software. However, the tests performed at NASA/MSFC under the HPTLVB program were actually simulated. In the current model, the hybrid motor consisting of the liquid oxygen (LOX) injector, the multi-port solid fuel grain and the nozzle was simulated. Also, simulated in the model was the LOX feed system consisting of the tank, venturi, valve and feed lines. All components of the hybrid motor and LOX feed system are treated by a lumped-parameter approach. Agreement between the results of the transient model and the actual test data was very good. This agreement between simulated and actual test data indicated that the combustion instability in the hybrid motor was due to two causes. The first cause was a LOX feed system of insufficient stiffness. The second cause was a LOX injector with an impedance or pressure drop that was too low to provide damping against the feed system oscillations. Also, it was discovered that testing with a new grain of solid fuel sustained the combustion instability. However, testing with a used grain of solid fuel caused the combustion instability to gradually decay.

Rocker, Marvin↗

Simulation of Non-Acoustic Combustion Instability in a Hybrid Rocket Motor

A transient model of a hybrid motor was formulated to study the cause and elimination of non-acoustic combustion instability. The transient model was used to simulate four key tests out of a series of seventeen hybrid motor tests conducted by Thiokol, Rocketdyne and Martin Marietta at NASA/Marshall Space Flight Center (NASAIMSFC). These tests were performed under the Hybrid Propulsion Technology for Launch Vehicle Boosters (HPTLVB) program. The first test resulted in stable combustion. The second test resulted in large-amplitude, 6.5 Hz chamber pressure oscillations that gradually damped away by the end of the test. The third test resulted in large-amplitude, 7.5 Hz chamber pressure oscillations that were sustained throughout the test. The seventh test resulted in the elimination of combustion instability with the installation of an orifice immediately upstream of the injector. The formulation and implementation of the model are the scope of this presentation. The current model is an independent continuation of modeling presented previously by joint Thiokol-Rocketdyne collaborators Boardman, Hawkins, Wassom, and Claflin. The previous model simulated an unstable IR&D hybrid motor test performed by Thiokol. There was very good agreement between the model and the test data. Like the previous model, the current model was developed using Matrix-x simulation software. However, the tests performed at NASA/MSFC under the HPTLVB program were actually simulated. In the current model, the hybrid motor consisting of the liquid oxygen (LOX) injector, the multi-port solid fuel grain and the nozzle was simulated. Also, simulated in the model was the LOX feed system consisting of the tank, venturi, valve and feed lines. All components of the hybrid motor and LOX feed system are treated by a lumped-parameter approach. Agreement between the results of the transient model and the actual test data was very good. This agreement between simulated and actual test data indicated that the combustion instability in the hybrid motor was due to two causes. The first cause was a LOX feed system of insufficient stiffness. The second cause was a LOX injector with an impedance or pressure drop that was too low to provide damping against the feed system oscillations. Also, it was discovered that testing with a new grain of solid fuel sustained the combustion instability. However, testing with a used grain of solid fuel caused the combustion instability to gradually decay.

Rocker, Marvin↗

Simulation of pressure and temperature responses for the 20 Inch Supersonic Wind Tunnel

A simulation of the pressure and temperature responses of the 20 inch Supersonic Wind Tunnel (SWT) is developed. The simulation models the tunnel system as a set of lumped parameter volumes connected by flow regulating elements such as valves and nozzles. Simulated transient responses of temperature and pressure for the five boundary points of the 20 inch SWT operating map are produced from their respective initial conditions, tunnel operating conditions, heater input power, and valve positions. Upon reaching steady state, a linearized model for each operating point is determined. Both simulated and actual tunnel responses are presented for comparison.

Motter, Mark A.↗

Electrodynamics of the Getaway Tether Experiment

An electrodynamic circuit model of the interaction of a pair of small tethered satellites and the ionosphere is developed and analyzed. The system under study, the Getaway Tether Experiment (GATE), is composed of two small satellites and 1 km of insulated conducting tether. The nonlinear model has elements representing the emission, collection, and resistive flow of charge through an electrically conductive tether, plasma contactors, and the ionosphere. The circuit model is incorporated into a dynamic orbital simulation to predict mission performance. Simulation results show the feasibility to bilaterally transfer energy between stored electrical energy and orbital momentum. A transient model is also developed using the circuit model and a string of N lumped-parameter modules, each consisting of resistance, capacitance, and induced potential for the tether. Transients are shown via simulation to occur over millisecond intervals.

Greene, Michael↗

Development of an analytical transient evacuation model for the fairing jettison process

A general, lumped-parameter, control volume equation is developed to describe the rapid loss of pressure associated with a launch vehicle fairing jettison event in its initial phase. Beginning with a general mass conservation statement, a sonic constraint is applied to the expanding gap between receding fairing halves to produce a statement for transient density. This is related to fairing pressure by assuming the expansion may be described by a polytropic process. A generic, single-step, lateral fairing half separation case is created and explored for illustrative purposes.

Fairing depressurization↗

Development of an analytical transient evacuation model for the fairing jettison process

A general, lumped-parameter, control volume equation is developed to describe the rapid loss of pressure associated with a launch vehicle fairing jettison event in its initial phase. Beginning with a general mass conservation statement, a sonic constraint is applied to the expanding gap between receding fairing halves to produce a statement for transient density. This is related to fairing pressure by assuming the expansion may be described by a polytropic process. A generic, single-step, lateral fairing half separation case is created and explored for illustrative purposes.

fairing depressurization↗

Development of an Analytical Transient Evacuation Model for the Fairing Jettison Process

A general, lumped-parameter, control volume equation is developed to describe the rapid loss of pressure associated with a launch vehicle fairing jettison event in its initial phase. Beginning with a general mass conservation statement, a sonic constraint is applied to the expanding gap between receding fairing halves to produce a statement for transient density. This is related to fairing pressure by assuming the expansion may be described by a polytropic process. A generic, single-step, lateral fairing half separation case is created and explored for illustrative purposes.

fairing depressurization, jettison, venting↗

Implementation of interconnect simulation tools in spice

Accurate computer simulation of high speed digital computer circuits and communication circuits requires a multimode approach to simulate both the devices and the interconnects between devices. Classical circuit analysis algorithms (lumped parameter) are needed for circuit devices and the network formed by the interconnected devices. The interconnects, however, have to be modeled as transmission lines which incorporate electromagnetic field analysis. An approach to writing a multimode simulator is to take an existing software package which performs either lumped parameter analysis or field analysis and add the missing type of analysis routines to the package. In this work a traditionally lumped parameter simulator, SPICE, is modified so that it will perform lossy transmission line analysis using a different model approach. Modifying SPICE3E2 or any other large software package is not a trivial task. An understanding of the programming conventions used, simulation software, and simulation algorithms is required. This thesis was written to clarify the procedure for installing a device into SPICE3E2. The installation of three devices is documented and the installations of the first two provide a foundation for installation of the lossy line which is the third device. The details of discussions are specific to SPICE, but the concepts will be helpful when performing installations into other circuit analysis packages.

Satsangi, H.↗

Dynamic Modeling of a Fast Spectrum Molten Salt Reactor Integrated Energy System

Liquid-fueled molten salt fast reactors and nuclear-powered integrated energy systems (IESs) have the potential to play a pivotal role in the green energy transition. However, these systems have little to no operating experience. There is therefore increased interest and value in modeling and simulating these systems. The IES dynamic model developed in this work utilizes a lumped-parameter control volume methodology to investigate the behavior of the IES in a variety of accident scenarios. The results provide initial evidence for the potential inherent safety of the advanced reactor because of temperature-dependent reactivity feedback and the efficiency of hydrogen and electricity production at the high temperatures provided by the advanced reactor.

MCFR↗

Program Computes Flows Of Fluids And Heat

SINDA'85/FLUINT incorporates lumped-parameter-network and one-dimensional-flow mathematical models. System enables analysis of mutual influences of thermal and flow phenomena. Offers two finite-difference numerical solution techniques: forward-difference explicit approximation and Crank-Nicholson approximation. Enables simulation of nonuniform heating and facilitates mathematical modeling of thin-walled heat exchangers. Ability to model nonequilibrium behavior within two-phase volumes included. Recent changes in program improve modeling of real evaporator pumps and other capillary-assist evaporators. Written in FORTRAN 77.

Cullimore, Brent↗

Numerical comparison of convective heat transfer augmentation devices used in cooling channels of hypersonic vehicles

Hypersonic vehicles are exposed to extreme thermal conditions compared to subsonic aircraft; therefore, some level of thermal management is required to protect the materials used. Normally, hypersonic vehicles experience the highest temperatures in the nozzle throat, and aircraft and propulsion system leading edges. Convective heat transfer augmentation techniques can be used in the thermal management system to increase heat transfer of the cooling channels in those areas. The techniques studied in this report are pin-fin, offset-fin, ribbed and straight roughened channel. A smooth straight channel is used as the baseline for comparing the techniques. SINDA '85, a lumped parameter finite difference thermal analyzer, is used to model the channels. Subroutines are added to model the fluid flow assuming steady one dimensional compressible flow with heat addition and friction. Correlations for convective heat transfer and friction are used in conjunction with the fluid flow analysis mentioned. As expected, the pin-fin arrangement has the highest heat transfer coefficient and the largest pressure drop. All the other devices fall in between the pin-fin and smooth straight channel. The selection of the best heat augmentation method depends on the design requirements. A good approach may be a channel using a combination of the techniques. For instance, several rows of pin-fins may be located at the region of highest heat flux, surrounded by some of the other techniques. Thus, the heat transfer coefficient is maximized at the region of highest heat flux while the pressure drop is not excessive.

Maldonado, Jaime J.↗

Quantitative Diagnosis of Continuous-Valued, Stead-State Systems

Quantitative diagnosis involves numerically estimating the values of unobservable parameters that best explain the observed parameter values. We consider quantitative diagnosis for continuous, lumped- parameter, steady-state physical systems because such models are easy to construct and the diagnosis problem is considerably simpler than that for corresponding dynamic models. To further tackle the difficulties of numerically inverting a simulation model to compute a diagnosis, we propose to decompose a physical system model in terms of feedback loops. This decomposition reduces the dimension of the problem and consequently decreases the diagnosis search space. We illustrate this approach on a model of thermal control system studied in earlier research.

Quantitative Diagnosis↗