Search NASA⌕ Search

SEARCH · Search NASA

Results for “lwir”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

GIFTS SM EDU Level 1B Algorithms

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) SensorModule (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiances using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the GIFTS SM EDU Level 1B algorithms involved in the calibration. The GIFTS Level 1B calibration procedures can be subdivided into four blocks. In the first block, the measured raw interferograms are first corrected for the detector nonlinearity distortion, followed by the complex filtering and decimation procedure. In the second block, a phase correction algorithm is applied to the filtered and decimated complex interferograms. The resulting imaginary part of the spectrum contains only the noise component of the uncorrected spectrum. Additional random noise reduction can be accomplished by applying a spectral smoothing routine to the phase-corrected spectrum. The phase correction and spectral smoothing operations are performed on a set of interferogram scans for both ambient and hot blackbody references. To continue with the calibration, we compute the spectral responsivity based on the previous results, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. We now can estimate the noise equivalent spectral radiance (NESR) from the calibrated ABB and HBB spectra. The correction schemes that compensate for the fore-optics offsets and off-axis effects are also implemented. In the third block, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is designed based on the pixel performance evaluation. Finally, in the fourth block, the single pixel algorithms are applied to the entire FPA.

Tian, Jialin↗

Digital Signal Processing Techniques for the GIFTS SM EDU

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes several digital signal processing (DSP) techniques involved in the development of the calibration model. In the first stage, the measured raw interferograms must undergo a series of processing steps that include filtering, decimation, and detector nonlinearity correction. The digital filtering is achieved by employing a linear-phase even-length FIR complex filter that is designed based on the optimum equiripple criteria. Next, the detector nonlinearity effect is compensated for using a set of pre-determined detector response characteristics. In the next stage, a phase correction algorithm is applied to the decimated interferograms. This is accomplished by first estimating the phase function from the spectral phase response of the windowed interferogram, and then correcting the entire interferogram based on the estimated phase function. In the calibration stage, we first compute the spectral responsivity based on the previous results and the ideal Planck blackbody spectra at the given temperatures, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. In the post-calibration stage, we estimate the Noise Equivalent Spectral Radiance (NESR) from the calibrated ABB and HBB spectra. The NESR is generally considered as a measure of the instrument noise performance, and can be estimated as the standard deviation of calibrated radiance spectra from multiple scans. To obtain an estimate of the FPA performance, we developed an efficient method of generating pixel performance assessments. In addition, a random pixel selection scheme is developed based on the pixel performance evaluation. This would allow us to perform the calibration procedures on a random pixel population that is a good statistical representation of the entire FPA. The design and implementation of each individual component will be discussed in details.

Tian, Jialin↗

Long-wavelength PTSI infrared detectors and method of fabrication thereof

Extended cutoff wavelengths of PtSi Schottky infrared detectors in the long wavelength infrared (LWIR) regime have been demonstrated for the first time. This result was achieved by incorporating a 1-nm-thick p+ doping spike at the PtSi/Si interface. The extended cutoff wavelengths resulted from the combined effects of an increased electric field near the silicide/Si interface due to the p+ doping spike and the Schottky image force. The p+ doping spikes were grown by molecular beam epitaxy at 450 degrees Celsius using elemental boron as the dopant source, with doping concentrations ranging from 1.times.10.sup.19 to 1.times.10.sup.21 cm.sup.-3. The cutoff wavelengths were shown to increase with increasing doping concentrations of the p+ spikes.

Lin, True-Lon↗

Comparison of Terra and Aqua MODIS VIS Bands On-Orbit Response

The Moderate Resolution Imaging Spectroradiometer (MODIS) has 36 spectral bands with a total of 490 detectors, covering spectral regions in the visible (VIS), near-infrared (NIR), short-wave infrared (SWIR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). MODIS is a cross-track scanning radiometer which collects data using a rotating scan mirror (both sides) over a wide range of scan angles. The VIS, NIR, and SWIR bands (bands 1-19 and 26) make measurements of daytime surface reflected radiances, thus are referred to as the reflective solar bands (RSB). MODIS was built with a complete set of on-board calibrators, capable of providing radiometric, spatial, and spectral calibration and characterization during its entire mission. The RSB on-orbit calibration is primarily provided using a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD and SDSM calibration system is operated on a regular (weekly to bi-weekly) basis. The spectro-radiometric calibration assembly (SRCA) is another on-hoard calibrator that also provides RSB radiometric calibration support. For this purpose, the SRCA is operated in a radiometric mode on a monthly basis. A complete SRCA radiometric calibration is performed using different lamp configurations, or different radiance levels, to cover the range of RSB gain. Two additional SRCA modes with slightly different configurations are designed and operated for sensor on-orbit spectral and spatial characterization. In addition to its on-hoard calibrators, each MODIS makes monthly lunar observations to monitor RSB radiometric calibration stability. The MODIS lunar observations are made through its space view (SV) port at nearly the same lunar phase angles via spacecraft roll maneuvers. The SD, SRCA, and lunar measurements are made at different scan angles and data samples are collected for all spectral bands and detectors using both sides of the scan minor. Since launch, Terra and Aqua MODIS have operated successfully for more than 8 years and 6 years, respectively. Many SD/SDSM, SRCA, and lunar observations have been made by each instrument and used to derive RSB on-orbit calibration parameters, enabling corrections for sensor response changes and changes of the response versus scan angle (RVS). In general, the RSB calibration parameters are updated regularly into the MODIS Level 1B (LIB) code in support of continuous data processing for all MODIS science data products. This paper provides a brief description of MODIS RSB calibration methodologies and approaches, and summarizes on-orbit changes of their responses (gains), particularly for the VIS spectral bands.

Xiong, Xiaoxiong↗

Characterization of MODIS VIS/NIR Spectral Band Detector-to-Detector Difference

MODIS has 36 spectral bands with wavelengths in the visible (VIS), near-infrared (NIR), shortwave infrared (SWTR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). It makes observations at three nadir spatial resolutions: 0,25km for bands 1-2 with 40 detectors per band, 0.5km for bands 3-7 with 20 detectors per band, and 1km for bands 8-36 with 10 detectors per band. The VIS, NIR, and S\VIR spectral bands are the reflective solar bands (RSB), which are calibrated on-orbit by a solar diffuser (SD). In addition, MODIS lunar observations are used to track the RSB calibration stability. In this study, we examine detector-to-detector calibration difference for the VIStNIR spectral bands using the SD and lunar observations. The results will be compared with an independent analysis with additional information, such as polarization correction, derived from standard ocean color data products. The current MODIS RSB calibration approach only carries a band-averaged RVS (response versus scan angle) correction. The results from this study suggest that a detector-based RVS correction should be used to improve the L1B data quality, especially for several VIS bands in Terra MODIS due to large changes of the scan mirror's optical properties in recent years.

Xiong, X.↗

MODIS On-board Blackbody Performance

Currently, there are two MODIS instruments operated on-orbit: one on-board the Terra spacecraft launched in December 1999 and the other on-board the Aqua spacecraft launched in May 2002. MODIS is a scanning radiometer that has 16 thermal emissive bands (TEBs) in the MWIR and LWIR regions. The remaining spectral bands are in the VISINIR and SWIR regions. The TEBs have a total of 160 detectors (10 detectors per band), which are calibrated on-orbit using an on-board blackbody (BB). MODIS TEB calibration is performed via a quadratic algorithm with its linear calibration coefficients updated on a scan-by-scan basis using each detector's response to the BB. The offset and nonlinear terms of the quadratic calibration equation are stored in a look-up table (LUT). The LUT parameters are derived from pre-launch calibration and updated on-orbit from BB observations, as needed. Typically, the BB is set at a fixed temperature. Periodically, a warm-up and cool-down activity is performed, which enables the BB temperature to be varied from instrument ambient up to 315K. The temperature of the BB is measured each scan using 12 thermistors, which were fully characterized pre-launch with reference to the NIST temperature scale. This paper describes MODIS on-board BB operational activities and performance. The TEB detector response (short-term stability and long-term changes) and noise characterization results derived from BB observations and their impact on the TEB calibration uncertainty are also presented.

Xiong, Xiaoxiong↗

Multiyear On-orbit Calibration and Performance of Terra MODIS Thermal Emissive Bands

Since launch in December 1999, Terra MODIS has been making continuous Earth observations for more than seven years. It has produced a broad range of land, ocean, and atmospheric science data products for improvements in studies of global climate and environmental change. Among its 36 spectral bands, there are 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). MODIS thermal emissive bands cover the mid-wave infrared (MWIR) and long-wave infrared (LWIR) spectral regions with wavelengths from 3.7 to 14.4pm. They are calibrated on-orbit using an on-board blackbody (BB) with its temperature measured by a set of thermistors on a scan-by-scan basis. This paper will provide a brief overview of MODIS TEB calibration and characterization methodologies and illustrate on-board BB functions and TEB performance over more than seven years of on-orbit operation and calibration. Discussions will be focused on TEB detector short-term stability and noise characterization, and changes in long-term response (or system gain). Results show that Terra MODIS BB operation has been extremely stable since launch. When operated at its nominal controlled temperature of 290K, the BB temperature variation is typically less than +0.30mK on a scan-by-scan basis and there has been no time-dependent temperature drift. In addition to excellent short-term stability, most TEB detectors continue to meet or exceed their specified noise characterization requirements, thus enabling calibration accuracy and science data product quality to be maintained. Excluding the noisy detectors identified pre-launch and those that occurred post-launch, the changes in TEB responses have been less than 0.7% on an annual basis. The optical leak corrections applied to bands 32-36 have been effective and stable over the entire mission

Xiong, Xiaoxiong↗

Radiometric Modeling and Calibration of the Geostationary Imaging Fourier Transform Spectrometer (GIFTS)Ground Based Measurement Experiment

The ultimate remote sensing benefits of the high resolution Infrared radiance spectrometers will be realized with their geostationary satellite implementation in the form of imaging spectrometers. This will enable dynamic features of the atmosphere s thermodynamic fields and pollutant and greenhouse gas constituents to be observed for revolutionary improvements in weather forecasts and more accurate air quality and climate predictions. As an important step toward realizing this application objective, the Geostationary Imaging Fourier Transform Spectrometer (GIFTS) Engineering Demonstration Unit (EDU) was successfully developed under the NASA New Millennium Program, 2000-2006. The GIFTS-EDU instrument employs three focal plane arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The GIFTS calibration is achieved using internal blackbody calibration references at ambient (260 K) and hot (286 K) temperatures. In this paper, we introduce a refined calibration technique that utilizes Principle Component (PC) analysis to compensate for instrument distortions and artifacts, therefore, enhancing the absolute calibration accuracy. This method is applied to data collected during the GIFTS Ground Based Measurement (GBM) experiment, together with simultaneous observations by the accurately calibrated AERI (Atmospheric Emitted Radiance Interferometer), both simultaneously zenith viewing the sky through the same external scene mirror at ten-minute intervals throughout a cloudless day at Logan Utah on September 13, 2006. The accurately calibrated GIFTS radiances are produced using the first four PC scores in the GIFTS-AERI regression model. Temperature and moisture profiles retrieved from the PC-calibrated GIFTS radiances are verified against radiosonde measurements collected throughout the GIFTS sky measurement period. Using the GIFTS GBM calibration model, we compute the calibrated radiances from data collected during the moon tracking and viewing experiment events. From which, we derive the lunar surface temperature and emissivity associated with the moon viewing measurements.

Tian, Jialin↗

Status of Terra and Aqua MODIS Instruments

Currently, two nearly identical MODIS instruments are operating in space: one on the Terra spacecraft launched in December 1999 and another on the Aqua spacecraft launched in May 2002. MODIS has 36 spectral bands with wavelengths covering from visible (VIS) to long-wave infrared (LWIR). Since launch, MODIS observations and data products have contributed significantly to studies of changes in the Earth system of land, oceans, and atmosphere. To maintain its on-orbit calibration and data product quality, MODIS was built with a comprehensive set of on-board calibrators, consisting of a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB) and an on-board blackbody (BB) for the thermal emissive bands (TEB). Both instruments have demonstrated good performance. The primary Level 1 B (LIB) data products are top of the atmosphere (TOA) reflectance for RSB and radiance for TEB This paper provides an overview of MODIS calibration methodologies, activities, lifetime on-orbit performance and challenging issues for each MODIS, the impact on LIB product quality, and lessons learned for future sensors such as the NPOESS VIIRS.

Xiong, Xiaoxiong↗

Performance of MODIS Thermal Emissive Bands On-orbit Calibration Algorithms

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) are currently operated on-board the Terra and Aqua spacecrafts, launched in December 1999 and May 2002, respectively. Together, they have produced an unprecedented amount of science data products, which are widely used for the studies of changes in the Earth's system of land, oceans, and atmosphere. MODIS is a cross-track scanning radiometer, which uses a two-sided scan mirror and collects data continuously over a wide scan angle range (+/-55 degree relative to the instrument nadir) each scan of 1.47 seconds. It has 36 spectral bands with wavelengths ranging from visible (VIS) to long-wave infrared (LWIR). MODIS bands 1-19 and 26 are the reflective solar bands (RSB) and bands 20-25 and 27-36 are the thermal emissive bands (TEB). MODIS was developed and designed with improvements made over its heritage sensors (such as AVHRR and Landsat) and, in particular, with more stringent calibration requirements. Because of this, MODIS was built with a set of state-of-art on-board calibrators (OBC), which include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. With the exception of view angle differences, MODIS OBC measurements and the Earth View (EV) observations are made via the same optical path. MODIS TEB have a total of 160 individual TEB detectors (10 per band), which are located on two cold focal plane assemblies (CFPA). For nominal on-orbit operation, the CFPA temperature is controlled at 83K via a passive radiative cooler. For the TEB, the calibration requirements at specified typical scene radiances are less than or equal to 1% with an exception for the fire detection (low gain) band. MODIS TEB on-orbit calibration is performed on a scan-by-scan basis using a quadratic calibration algorithm, and data collected from sensor responses to the onboard BB and SV. The BB serves as the thermal calibration source and the SV provides measurements for the sensor's background and offsets. MODIS on-board BB is a v-grooved plate with its temperature measured using 12 platinum resistive thermistors (PRT) uniformly embedded in the BB substrate. All the BB thermistors were characterized pre-launch with reference to the NIST temperature standards. Unlike typical BB operations in many heritage sensors, which have no temperature control capability, the MODIS on-board BB can be operated at any temperatures between instrument ambient (about 270K) and 315K and can also be varied continuously within this range. This feature has significantly enhanced the MODIS' capability of tracking and updating the TEB nonlinear calibration coefficients over its entire mission. Following a brief description of MODIS TEB on-orbit calibration methodologies and its onboard BB operational activities, this paper provides a comprehensive performance assessment of MODIS TEB quadratic calibration algorithm. It examines the scan-by-scan, orbit-by-orbit, daily, and seasonal variations of detector responses and associated impact due changes in the CFPA and instrument temperatures. Specifically, this paper will analyze the contribution by each individual thermal emissive source term (BB, scan cavity, and scan mirror), the impact on the Level 1 B data product quality due to pre-launch and on-orbit calibration uncertainties. A comparison of Terra and Aqua TEB on-orbit performance, lessons learned, and suggestions for future improvements will also be made.

Xiong, Xiaoxiong↗

Recent Progress on Cross-Comparison of Terra and Aqua MODIS Calibration Using Dome C

For the past few years, the MODIS Characterization Support Team (MCST) at NASA/GSFC has continued to evaluate the Terra and Aqua MODIS calibration long-term stability and their calibration consistency using sensor observations over the Dome Concordia, Antarctica. Early results from Dome C observations show that the calibration of bands I and 2 (0.65 and 0.86 micron) is consistent within 1-2% and bands 31 and 32 (11 and 12 micron) differences are less than a couple of tenths of Kelvin, demonstrating that this site can provide a useful calibration reference for a wide range of Earth-observing sensors from visible (VIS) to long-wave infrared (LWIR). Recently, the Dome C area has been endorsed by the CEOS as a reference standard site for sensor cross-comparison. This, as a result, has led to an invitation to the broad community to participate in a CEOS comparison of top-of-atmosphere (TOA) spectral radiance/reflectance over Dome C. In this paper, we provide a brief description of the methodologies and report our recent progress on cross-comparison of Terra and Aqua MODIS spectral bands using observations over this area, including data provided in support of the upcoming CEOS comparison. Emphasis of this paper is on the long-term data records of MODIS instruments, their calibration consistency, and challenging issues.

Xiong, X.↗

Using Dome C for Moderate Resolution Imaging Spectroradiometer Calibration Stability and Consistency

Currently, there are two nearly identical moderate resolution imaging spectroradiometer (MODIS) instruments operated in space: one on the Terra spacecraft launched in December 1999 and another on the Aqua spacecraft launched in May 2002. MODIS has 36 spectral bands with wavelengths covering from visible (VIS) to long-wave infrared (LWIR). Since launch, M0DIS observations and data products have significantly enabled studies of changes in the Earth system of land, oceans, and atmosphere. In order to maintain its on-orbit calibration and data product quality, MODIS was built with a comprehensive set of on-board calibrators. MODIS reflective solar bands (RSB) are calibrated on-orbit by a system that consists of a solar diffuser (SD) and a solar diffuser stability monitor(SDSM) on a regular basis. Its thermal emissive bands (TEB) calibration is executed on a scan-by-scan basis using an on-board blackbody (BB). The MODIS Characterization Support Team (MCST) at NASA/GSFC has been responsible for supporting sensor calibration and characterization tasks from pre-launch to post launch. In this paper,we describe current MCST efforts and progress made to examine sensor stability and intercalibration consistency using observations over Dome Concordia, Antarctica. Results show that this site can provide useful calibration reference for Earth-observing sensors.

Xiong, Xiaoxiong↗

Results and Lessons from a Decade of Terra MODIS On-Orbit Spectral Characterization

Since its launch in December 1999, the NASA EOS Terra MODIS has successfully operated for more than a decade. MODIS makes observations in 36 spectral bands from visible (VIS) to longwave infrared (LWIR) and at three nadir spatial resolutions: 250m (2 bands), 500m (5 bands), and 1km (29 bands). In addition to its on-board calibrators designed for the radiometric calibration, MODIS was built with a unique device, called the spectro-radiometric calibration assembly (SRCA). It can be configured in three different modes: radiometric, spatial, and spectral. When it is operated in the spectral modes, the SRCA can monitor changes in Sensor spectral performance for the VIS and near-infrared (NIR) spectral bands. For more than 10 years, the SRCA operation has continued to provide valuable information for MODIS on-orbit spectral performance. This paper briefly describes SRCA on-orbit operation and calibration activities; it presents decade-long spectral characterization results for Terra MODIS VIS and NIR spectral bands in terms of chances in their center wavelengths (CW) and bandwidths (BW). It is shown that the SRCA on-orbit wavelength calibration capability remains satisfactory. For most spectral bands, the changes in CW and BW are less than 0.5 and 1 nm, respectively. Results and lessons from Terra MODIS on-orbit spectral characterization have and will continue to benefit its successor, Aqua MODIS, and other future missions.

Xiong, X.↗

Photodetector Arrays for Multicolor Visible/Infrared Imaging

Monolithic focal-plane arrays of photodetectors capable of imaging the same scenes simultaneously in multiple wavelength bands in the visible and infrared spectral regions have been proposed. In prior visible/infrared imaging systems, it has been standard practice to use separate optical trains to form images in visible and infrared wavelength bands on separate visibleand infrared-photodetector arrays. Because the proposal would enable the detection of images in multiple wavelength bands on the same focal plane, the proposal would make it unnecessary to use multiple optical trains. Hence, multispectral imaging systems could be made more compact and the difficulties of aligning multiple optical trains would be eliminated. Each pixel in an array according to the proposal would contain stacks of several photodetectors. The proposal is a logical extension of prior concepts of arrays of stacked photodetectors for imaging in two or three wavelength bands. For example, such an array was described in Three-Color Focal-Plane Array of Infrared QWIPs (NPO-20683), NASA Tech Briefs, Vol. 24, No. 5 (May 2000), page 26a. In one proposed design, (see figure), each pixel would be divided into four subpixels, one being dedicated to a visible- and-near-infrared (V) band, one to a combination of the V band and a verylong- wavelength infrared (VLWIR) band, one to a combination of the V band and a long-wavelength infrared (LWIR) band, and one to a combination of the V band and a medium-wavelength infrared (MWIR) band. For this purpose, each subpixel would include a GaAs-based positive/intrinsic/negative (PIN) photodiode for detection in the V band stacked with three quantum-well infrared photodetectors (QWIPs), each optimized for one of the aforementioned infrared bands. The stacks of photodetectors in all the subpixels would be identical except for the electrical connections, which would be configured to activate the various wavelengthband combinations.

Gunapala, Sarath↗

MODIS On-Orbit Performance and Lessons Learned

MODIS is a key instrument for the NASA's Earth Observing System (EOS) and has successfully operated for more than 11 and 9 years, respectively, on-board the Terra and Aqua spacecraft. MODIS collects data in 36 spectral bands, covering wavelengths from visible (VIS) to long-wave infrared (LWIR). To date, both Terra and Aqua MODIS have produced an unprecedented amount of data products and significantly contributed to the earth remote sensing studies and applications. MODIS was developed with stringent calibration requirements and was, consequently, designed and built with a set of on-board calibrators (OBC), which include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), and a spectroradiometric calibration assembly (SRCA). This presentation briefly reviews MODIS instrument operation and various calibration and characterization activities, It demonstrates both the instrument and the OBC on-orbit performance and discusses lessons learned, particularly focusing on on-orbit changes in sensor responses, optics degradation, and major challenging issues. As expected, Terra and Aqua MODIS on-orbit performance and lessons learned will continue to benefit the operation and calibration of future sensors, such as NPP/JPSS VIIRS and GOES-R ABI.

Xiong, Xiaoxiong↗

Nulling Infrared Radiometer for Measuring Temperature

A nulling, self-calibrating infrared radiometer is being developed for use in noncontact measurement of temperature in any of a variety of industrial and scientific applications. This instrument is expected to be especially well-suited to measurement of ambient or near-ambient temperature and, even more specifically, for measuring the surface temperature of a natural body of water. Although this radiometer would utilize the long-wavelength infrared (LWIR) portion of the spectrum (wavelengths of 8 to 12 m), its basic principle of operation could also be applied to other spectral bands (corresponding to other temperature ranges) in which the atmosphere is transparent and in which design requirements for sensitivity and temperature-measurement accuracy could be satisfied.

Ryan, Robert↗

HyTES: Thermal Imaging Spectrometer Development

The Jet Propulsion Laboratory has developed the Hyperspectral Thermal Emission Spectrometer (HyTES). It is an airborne pushbroom imaging spectrometer based on the Dyson optical configuration. First low altitude test flights are scheduled for later this year. HyTES uses a compact 7.5-12 micrometer m hyperspectral grating spectrometer in combination with a Quantum Well Infrared Photodetector (QWIP) and grating based spectrometer. The Dyson design allows for a very compact and optically fast system (F/1.6). Cooling requirements are minimized due to the single monolithic prism-like grating design. The configuration has the potential to be the optimal science-grade imaging spectroscopy solution for high altitude, lighter-than-air (HAA, LTA) vehicles and unmanned aerial vehicles (UAV) due to its small form factor and relatively low power requirements. The QWIP sensor allows for optimum spatial and spectral uniformity and provides adequate responsivity which allows for near 100mK noise equivalent temperature difference (NEDT) operation across the LWIR passband. The QWIP's repeatability and uniformity will be helpful for data integrity since currently an onboard calibrator is not planned. A calibration will be done before and after eight hour flights to gage any inconsistencies. This has been demonstrated with lab testing. Further test results show adequate NEDT, linearity as well as applicable earth science emissivity target results (Silicates, water) measured in direct sunlight.

remote sensing↗

Next Generation Grating Spectrometer Sounders for LEO and GEO

AIRS and MODIS are widely used for weather, climate, composition, carbon cycle, cross-calibration, and applications. The community asking for new capability in the 2020 timeframe, capabilities desired: (1) Hyperspectral UV to LWIR, High Spatial ?1km IFOV (2) Maximize Synergies of Solar Reflected and IR. Synergies with OCO-2. We expect more users and applications of next gen LEO IR Sounder than GEO. These include: weather, climate, GHG monitoring, aviation, disaster response. There is a new direction for imagers and sounders: (1) Separate Vis/NIR/SWIR from MWIR/LWIR instruments reduces technology risk and complexity. (2) Expect Costs to be lower than CrIS & VIIRS Some additional ideas to reduce costs include: (1) minimum set of requirements (2) mini-grating spectrometers. supports constellation for higher revisit (3) new technology to reduce instrument size (large format fpa's) (4) hosted payloads

Hyperspectral↗