Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic coupling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Parabolic dish collectors - A solar option

A description is given of several parabolic-dish high temperature solar thermal systems currently undergoing performance trials. A single parabolic dish has the potential for generating 20 to 30 kW of electricity with fluid temperatures from 300 to 1650 C. Each dish is a complete power-producing unit, and may function either independently or as part of a group of linked modules. The two dish designs under consideration are of 11 and 12 meter diameters, yielding receiver operating temperatures of 925 and 815 C, respectively. The receiver designs described include (1) an organic working fluid (toluene) Rankine cycle engine; (2) a Brayton open cycle unit incorporating a hybrid combustion chamber and nozzle and a shaft-coupled permanent magnet alternator; and (3) a modified Stirling cycle device originally designed for automotive use. Also considered are thermal buffer energy storage and thermochemical transport and storage.

Truscello, V. C.↗

Winds from Rotating, Magnetic, Hot Stars

The effect of a magnetic field coupled with stellar rotation on the wind from a hot star, which is driven primarily by line radiation pressure, is discussed.

Friend, D. B.↗

Corequake and shock heating model of the 5 March 1979 gamma-ray burst

Ramaty et al. (1980) have proposed a model of a neutron-star corequake and subsequent shock heating of the atmosphere to account for the gamma-ray burst of March 5, 1979. This model is elaborated by examining the overall energetics and characteristics of the radiation-dominated gas shocks under the assumption of thermodynamic equilibrium, taking into account the electron-positron pair production behind the shock. Using values for the density typical of those expected for neutron-star crusts (100-10,000 g/cu cm) and shock velocities characteristic of the sound speed (40,000-100,000), shock luminosities are obtained comparable to those required if the burst originated in the LMC. In addition, the fraction of energy deposited in electron-positron pairs is in good agreement with observation. Uneven shock heating between the polar and equatorial regions of the neutron star due to the presence of a dipole magnetic field, coupled with a rotation rate of 8 s, can also naturally account for the pulsating phase of the burst.

Ellison, D. C.↗

Raman scattering from phonons and magnons in magnetic semiconductors, MnTe

Comparisons are made between theoretical and experimental data on laser Raman scattering by phonons and two-magnons in antiferromagnetic and paramagnetic phases of MnTe. The study was performed specifically to characterize the magnetic exchange coupling constants of the Mn ions in the samples. Crystal MnTe samples were bombarded with an Ar ion laser beam to obtain spectrometer and photon counter data. One E(2g) phonon with a room temperature energy of 178/cm and a two-magnon peak of 360/cm were observed in the Raman spectrum. A spin wave dispersion relation is presented for the spectrum. Finally, a Monte Carlo technique was used to calculate the two-magnon joint density of states that best fits the experimental data.

Mobasser, S. R.↗

Diagnostics and structure

The structure of prominences and the diagnostic techniques used to evaluate their physical parameters are discussed. These include electron temperature, various densities (n sub p, n sub e, n sub l), ionization degree, velocities, and magnetic field vector. UV and radio measurements have already evidenced the existence of different temperature regions, corresponding to different geometrical locations, e.g., the so called Prominence-Corona (P-C) interface. Velocity measurements are important for considering formation and mass balance of prominences but there are conflicting velocity measurements which have led to the basic question: what structure is actually observed at a given wavelength; what averaging is performed within the projected slit area during the exposure time? In optically thick lines, the question of the formation region of the radiation along the line of sight is also not a trivial one. The same is true for low resolution measurements of the magnetic field. Coupling diagnostics with structure is now a general preoccupation.

Vial, J. C.↗

On the initial motion of artificial comets in the AMPTE releases

A model describing the initial Ba(+) cloud noted in the AMPTE program is presented which stresses the diamagnetic aspects of the interaction. Based on the observed magnetic field profile, it is suggested that the Ba(+) gyroradius becomes shorter than the cloud radius, and that the Ba(+) ions are magnetized. Momentum coupling force between the Ba(+) cloud and the solar wind in their relative streaming direction will produce an acceleration drift in the direction identical to the observed motion of the cloud, and the observed acceleration force is used to compute the magnitude of the coupling force and to compare it with other models.

Papadopoulos, K.↗

Discovery of radio emission from AE Aquarii

VLA 1.4-GHz and 4.9-GHz observations of six DQ Her cataclysmic variables, obtained in the C/D hybrid configuration with 50-MHz bandwidth, 7-sec time resolution, and limiting flux density about 200 microJy on July 21, 1984, are reported. Variable radio emission with time scale less than 5 min, circular polarization less than 15 percent, and flux density 3-5 mJy at 1.4 GHz and 8-16 mJy at 4.9 GHz is detected from AE Aqr. This emission is tentatively attributed to synchrotron emission from mildly relativistic electrons, powered by the MHD torque coupling the magnetic white dwarf to either (1) a secondary with a strong magnetic field or (2) an accretion disk.

Bookbinder, J. A.↗

Electron Spin Resonance (ESR) Studies of Returned Comet Nucleus Samples

Electron Spin Resonance (ESR) studies have been carried out on organic and inorganic free radicals generated by gamma-ray and/or UV-irradiation and trapped in ice matrices. It is suggested that the concentration of these free radicals together with their thermal stability can be used as an accurate built-in geothermometer and radiation probe for returned comet nucleus sample studies. ESR studies have also been carried out on paramagnetic (Mn(2+), Ti(3+), and Fe(3+)) and ferromagnetic (ferric oxide and metallic iron) centers known to be present in terrestrial and extraterrestrial samples. The presence or absence of these magnetic centers coupled with their characteristic ESR lineshape can be used to investigate the shock effects, quenching/cooling rate and oxidation-reduction conditions in the formation and subsequent evolution of returned comet nucleus samples.

Tsay, Fun-Dow↗

Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or pixilated array of x-ray absorbers shares fewer numbers of temperature sensors. A means of discriminating the signals from different absorber positions, however, needs to be built into the device for each sensor. The design concept for the device is such that the shape of the temperature pulse with time depends on the location of the absorber. This inherent position sensitivity of the signal is then analyzed to determine the location of the event precisely, effectively yielding one device with many sub-pixels. With such devices, the total number of electronic channels required to read out a given number of pixels is significantly reduced. PoSMs were developed that consist of four discrete absorbers connected to a single magnetic sensor. The design concept can be extended to more than four absorbers per sensor. The thermal conductance between the sensor and each absorber is different by design and consequently, the pulse shapes are different depending upon which absorber the xrays are received, allowing position discrimination. A magnetic sensor was used in which a paramagnetic Au:Er temperature-sensitive material is located in a weak magnetic field. Deposition of energy from an x-ray photon causes an increase in temperature, which leads to a change of magnetization of the paramagnetic sensor, which is subsequently read out using a low noise dc-SQUID. The PoSM microcalorimeters are fully microfabricated: the Au:Er sensor is located above the meander, with a thin insulation gap in between. For this position-sensitive device, four electroplated absorbers are thermally linked to the sensor via heat links of different thermal conductance. One pixel is identical to that of a single-pixel design, consisting of an overhanging absorber fabricated directly on top of the sensor. It is therefore very strongly thermally coupled to it. The three other absorbers are supported directly on a silicon-nitride membrane. These absorbers are thermally coupled to the sensor via Ti (5 nm)/Au250 nm) metal links. The strength of the links is parameterized by the number of gold squares making up the link. For detector performance, experimentally different pulse-shapes were demonstrated with 6 keV x-rays, which clearly show different rise times for different absorber positions. For energy resolution measurement, the PoSM was operated at 32 mK with an applied field that was generated using a persistent current of 50 mA. Over the four pixels, energy resolution ranges from 4.4 to 4.7 eV were demonstrated.

Bandler, SImon↗

X-ray emission from pre-main-sequence stars, molecular clouds and star formation

The pre-main sequence X-ray emitting stars observed in molecular clouds appear to provide the bulk of the ionization. Newly forming stars therefore control the coupling of the magnetic field to the cloud. Since this coupling itself is believed to be responsible for the rate of cloud collapse, it is suggested that there is a natural feedback mechanism, involving observed X-rays, which is capable of regulating molecular cloud evolution and the rate of star formation.

Silk, J.↗

The Micro‐Macro Coupling of Mass‐Loading in Symmetric Magnetic Reconnection With Cold Ions

We investigate how magnetic reconnection is influenced by an inflow of a dense cold ion population. We compare two 2.5D Particle-In-Cell simulations, one containing the cold population and one without. We find that the cold population influences the reconnection process on both global and kinetic scales, and that the dominant contribution can be explained through mass-loading. We provide an analysis of how these multiscale changes are related through kinetic processes in the ion diffusion region, the so-called micro-macro coupling of mass-loading. The inertia of the cold ion population is found to be the significant link that connects the changes on different scales. The cold and warm populations exhibit counter streaming behavior when and after the ion diffusion region reorganizes itself in response to the arrival of the cold population. This signature of the cold population should be observable by spacecraft observatories such as MMS.

Magnetic reconnection↗

Does the geoid drift west?

In 1970 Hide and Malin noted a correlation of about 0.8 between the geoid and the geomagnetic potential at the Earth's surface when the latter is rotated eastward in longitude by about 160 degrees and the spherical harmonic expansions of both functions are truncated at degree 4. From a century of magnetic observatory data, Hide and Malin inferred an average magnetic westward drift rate of about 0.27 degrees/year. They attributed the magnetic-gravitational correlation to a core event at about 1350 A.D. which impressed the mantle's gravity pattern at long wavelengths onto the core motion and the resulting magnetic field. The impressed pattern was then carried westward 160 degrees by the nsuing magnetic westward drift. An alternative possibility is some sort of steady physical coupling between the magnetic and gravitational fields (perhaps migration of Hide's bumps on the core-mantle interface). This model predicts that the geoid will drift west at the magnetic rate. On a rigid earth, the resulting changes in sea level would be easily observed, but they could be masked by adjustment of the mantle if it has a shell with viscosity considerably less than 10 to the 21 poise. However, steady westward drift of the geoid also predicts secular changes in g, the local acceleration of gravity, at land stations. These changes are now ruled out by recent independent high-accuracy absolute measurements of g made by several workers at various locations in the Northern Hemisphere.

Backus, G. E.↗

Tunable Magnetic Resonance in Microwave Spintronics Devices

Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe-based tunable microwave spintronics devices, which is 10X higher than conventional methods.

Microwave Detectors↗

Tunable Magnetic Resonance in Microwave Spintronics Devices

Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

Microwave Detectors↗

Developing Glassy Magnets from Simulated Composition of Martian Soil for Exploration Applications

The long-term exploration goals of NASA include developing human habitation on Mars and conducting scientific investigations on Mars and other planetary bodies. In situ resource processing is a key objective in this area. We focus on the possibility of making magnetic glasses in situ for potential applications development. The paper will focus on ongoing work at NASA Marshall Space Flight Center on making magnetic glass from Mars soil simulants and its characterization. Analysis of the glass morphology, strength, chemistry and resulting magnetic properties will provide a fundamental understanding of the synthesized material that can be used for potential applications development. in an effort to characterize the magnetic properties of the Mars glasses, a series of tests were performed at NASA MSFC. Preliminary tests indicated that the glasses were attracted to a magnet and also had a small amount of residual magnetism. They were opaque (almost black in color). As the first step, a sample of Mars 1 glass (approx.1 mm x 1 mm x 5 mm length) was machined, weighed and its hysteresis curve was measured using a Vibration Sample Magnetometer (VSM). Next, a small furnace was designed and built and the sample was baked in a graphite (reducing agent) crucible at 800 C in an Argon atmosphere for 3 hours in the presence of a uniform, transverse (transverse to the 5mm length of the sample) magnetic field of 0.37 Tesla. The treated sample showed reddening on the outside and showed substantially increased residual magnetism. This sample was again analyzed in the VSM. The data clearly showed that some chemical change occurred during the heat treatment (color change) and that both the glasses have useful magnetic properties. Although no orientation effects of the magnetic field were considered, the data showed the following: 1. Both glass samples are primarily soft magnets and display ferromagnetic behavior (hysteresis, saturation, etc.) 2. The treated glass has improved saturation magnetism (order of magnitude increase), retentivity (factor of 6 increase) and susceptibility (order of magnitude increase) compared to the untreated glass 3. The untreated sample has higher coercivity (approx.50% that of Nickel) than the treated sample 4. Both samples have similar energy density. Results from a systematic study to quantify the effects of processing conditions such as heat treatment, atmosphere, containerless processing (by electrostatic levitation), and applications of external magnetic fields of different strengths will be discussed. Efforts on optimizing the magnetic properties of the product and the feasibility of using it for a couple of specific magnetic applications such as heat generation using an ac field and for electro forming will also be covered. The latter is an in situ manufacturing technique being studied for in-space fabrication applications at MSFC.

Ramachandran, N.↗