Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Particle-laden weakly swirling free jets - Measurements and predictions

A theoretical and experimental investigation of particle-laden, weakly swirling, turbulent free jets was conducted. Glass particles, having a Sauter mean diameter of 39 microns with a standard deviation of 15 microns, were used. A single loading ratio of 0.2 was used in the experiments. Measurements are reported for three swirl numbers, ranging from 0.0 to 0.3. The measurements included mean and fluctuating velocities of both phases, and particle mass flux distributions. Measurements were compared with predictions from three types of multiphase flow analysis: locally homogeneous flow (LHF); deterministic separated flow (DSF); and stochastic separated flow (SSF). For the particle-laden jets, the LHF and DSF models did not provide very satisfactory predictions. The LHF model generally overestimated the rate of decay of particle mean axial and angular velocities with streamwise distance, due to the neglect of particle inertia. The LHF model predictions of particle mass flux also showed poor agreement with measurements due to the assumption of no-slip between phases. The DSF model also performed quite poorly for predictions of particle mass flux, because turbulent dispersion of the particles was neglected. The SSF model, which accounts for both particle inertia and turbulent disperison of the particles, yielded reasonably good predictions throughout the flow field for the particle-laden jets.

Bulzan, Daniel L.↗

Quantitative determination of engine water ingestion

A nonintrusive optical technique is described for determination of liquid mass flux in a droplet laden airstream. The techniques were developed for quantitative determination of engine water ingestion resulting from heavy rain or wheel spray. Independent measurements of the liquid water content (LWC) of the droplet laden airstream and of the droplet velocities were made at the stimulated nacelle inlet plane for the liquid mass flux determination. The LWC was measured by illuminating and photographing the droplets contained within a thin slice of the flow field by means of a sheet of light from a pulsed laser. A fluorescent dye introduced in the water enchanced the droplet image definition. The droplet velocities were determined from double exposed photographs of the moving droplet field. The technique was initially applied to a steady spray generated in a wind tunnel. It was found that although the spray was initially steady, the aerodynamic breakup process was inherently unsteady. This resulted in a wide variation of the instantaneous LWC of the droplet laden airstream. The standard deviation of ten separate LWC measurements was 31% of the average. However, the liquid mass flux calculated from the average LWC and droplet velocities came within 10% of the known water ingestion rate.

Parikh, P.↗

Quantitative determination of engine water ingestion

This paper describes a novel non-intrusive optical technique for determination of liquid mass flux in a droplet laden airstream. The technique was developed for quantitative determination of engine water ingestion resulting from heavy rain or wheel spray. Independent measurements of the liquid water content (LWC) of the droplet laden aircraft and of the droplet velocities were made at the simulated nacelle inlet plane for the liquid mass flux determination. The liquid water content was measured by illuminating and photographing the droplets contained within a thin slice of the flow field by means of a sheet of light from a pulsed YAG laser. A fluorescent dye introduced in the water greatly improved the droplet image definition. The droplet velocities were determined from double exposed photographs of the moving droplet field. The technique was initially applied to a steady spray generated in a wind tunnel. It was found that although the spray was initially steady, the aerodynamic breakup process was inherently unsteady. This resulted in a wide variation of the instantaneous liquid water content of the droplet laden airstream. The standard deviation of ten separate LWC measurements was 31 percent of the average. However, the liquid mass flux calculated from the average LWC and droplet velocities came within 10 percent of the known water ingestion rate.

Parikh, P.↗

Burner Emissions Associated with Lobed and Non-Lobed Fuel Injectors

The present experimental study examines NO(sub x), and CO emissions associated with three alternative fuel-injector geometries. These injectors mix fuel and air and strain their interfaces to differing extents and thus create different local equivalence ratios within flow regions upstream of flame ignition and stabilization. Two of the devices studied are lobed fuel injectors, in which molecular mixing of reactants is associated with streamwise vorticity generation, while the third one is a non-lobed fuel injector. Results show that rapid mixing allowed both lobed injector geometries to produce very lean premixed flame structures, with a lower achievable turn-down or fuel/air mass flux ratio than for the analogous non-lobed injector, which largely, produced distinct diffusion flames. All three injectors exhibited some level of sooting near walls and in the far-field region, with the non-lobed injector sooting to the greatest extent. At low fuel flow rates, in which the lobed injectors created locally very lean premixed conditions, there resulted lower NO(sub x) emissions as compared with non-lobed injector emissions. Yet at higher fuel-air mass flux ratios, NO(sub x) emissions from the lobed injectors were actually higher than for the nonlobed injector, likely due to reduced sooting and hence reduced radiative heat losses associated with enhanced mixing. For both lobed injector geometries examined here, CO emissions became high for low values of the fuel/air mass flux ratio, again consistent with locally premixed combustion behavior, despite the fact that fuel was injected separately from air directly into the burner test section. The present study demonstrates that, for fuel-air mixing enhancement devices, control of the local equivalence ratio is critical in order to optimize burner emissions.

Mitchell, M. G.↗

Measurements of Freestream Fluctuations in the NASA Langley 20-Inch Mach 6 Tunnel

An experimental campaign was conducted to measure and to characterize the freestream disturbance levels in the NASA Langley Research Center 20-Inch Mach 6 Wind Tunnel. A pitot rake was instrumented with fast pressure transducers, hot wires, and an atomic layer thermopile to quantify the fluctuation levels of pressure, mass flux, and heat flux, respectively. In conjunction with these probe-based measurements, focused laser differential interferometry was used to optically measure density fluctuations. Measurements were made at five nominal different unit Reynolds numbers ranging from (3.28 to 26.5) times 10 (sup 6) per meter. The rake was positioned at two different stream-wise locations and several different roll angles to measure flow uniformity within the test section. In general, noise levels were spatially consistent within the tested region. Pitot pressure fluctuation levels ranged from 0.84 percent at the highest Reynolds number tested to 1.89 percent at the lowest Reynolds number tested. Freestream mass-flux fluctuations remained relatively constant between 1.8-2.5 percent of the freestream. The pressure transducers were also used to determine the dominant disturbance speed and angle of propagation. The disturbances were estimated to travel at approximately 54-81 percent of the freestream speed at an angle of approximately 21-44 degrees from the freestream direction, but these measurements had a significant amount of uncertainty. A comparison to previous measurements of pressure made in 2012 and of mass flux made in 1994 show almost no change in the RMS (Root Mean Square) fluctuation of these flow quantities.

Chou, Amanda↗

Enthalpy Distributions of Arc Jet Flow Based on Measured Laser Induced Fluorescence, Heat Flux and Stagnation Pressure Distributions

The centerline total enthalpy of arc jet flow is determined using laser induced fluorescence of oxygen and nitrogen atoms. Each component of the energy, kinetic, thermal, and chemical can be determined from LIF measurements. Additionally, enthalpy distributions are inferred from heat flux and pressure probe distribution measurements using an engineering formula. Average enthalpies are determined by integration over the radius of the jet flow, assuming constant mass flux and a mass flux distribution estimated from computational fluid dynamics calculations at similar arc jet conditions. The trends show favorable agreement, but there is an uncertainty that relates to the multiple individual measurements and assumptions inherent in LIF measurements.

Suess, Leonard E.↗

On the global exchange of mass between the stratosphere and troposphere

Seasonal mean downward mass fluxes across the 100 mb level in the extratropics of both hemispheres are computed using the meridionally integrated residual vertical circulation as determined from the transformed Eulerian mean equations. The eddy momentum and heat flux data required for the calculation are taken from Oort's 15-year climatology. Upward mass flux from the troposphere to the stratosphere in the tropics is computed from mass continuity. The flux is a maximum during Northern Hemisphere winter and a minimum during Northern Hemisphere summer. The computed fluxes imply a 2.5 year turnover time for the global atmospheric layer above 100 mb.

Holton, J. R.↗

Parametric representation of heat and moisture fluxes in cloud-topped mixed layers

The Betts (1973, 1978) parametrization of heat and moisture fluxes is tested using measurements made in thin, broken, and solid stratocumulus clouds by the NCAR Electra off the California coast in June 1976. The turbulence data are used to determine updraft-downdraft properties, heat and moisture fluxes, spectra, and cospectra. From the convective properties, vertical mass flux profiles are obtained and examined for consistency. A convective scaling which is appropriate for cloud-topped mixed layers is discussed. The results demonstrate the usefulness of a mass flux formulation in modeling applications for cloud conditions varying between solid and broken.

Penc, Richard S.↗

Vector representation of trade cumulus thermodynamic fluxes

A tephigram of BOMEX averaged thermodynamic flux vectors, developed from two tradewind budgets, is presented. The parametric model, which is utilized to represent the fluxes in the tradewind layer of the product as a mass flux and a cloud-environment difference, is examined. A table of mean structure and fluxes of a dataset for the BOMEX ship array, and the Bowen ratio and convective mass flux for a nonmixing and a cloud-top mixing model is provided. The fluxes which are displayed in a simple vector format, using the saturation point notation of Betts (1982) reveal a coupling of fluxes and the relationship between Bowen ratio and height. It is concluded that with good tradewind budget data about the statistics of cloud mixing and radiative-convective coupling can be expressed.

Betts, A. K.↗

A bubblelike coronal mass ejection flux rope in the solar wind

A resolution to the question of whether coronal mass ejections are loops or bubbles is proposed and applied to the geometrical analysis of a solar wind event detected at 1 AU by ISEE 1 and 3. The discontinuity orientations, the size determined by time of passage, and the magnetic cloud signature are fit into the topology of a flux rope loop distorted by expansion into a thick rope with comparable dimensions in both the ecliptic and meridional planes. The looped rope fills a bubblelike cavity, thus preserving both types of proposed coronal mass ejection geometries. Other interesting features of the data include an apparent separation by the rope core of bidirectionally streaming protons in the leading section from electrons in the trailing section, possible vortical flow within the magnetic cloud, and a well-defined filamentary structure behind the shock.

Crooker, N. U.↗

Star formation in the cooling flows of M87/Virgo and NGC 1275/Perseus

X-ray observations indicate that M87/Virgo and NGC 1275/Perseus have cooling flows that are associated with accretion rates of 20-30 and 300-500 solar masses/year, respectively. An assessment is made as to whether star formation is necessarily occurring in these cooling flows by calculating constant mass-flux models for all reasonable parameter space. No constant-mass-flux models that are consistent with all of the relevant observations are found; hence, it is concluded that mass is dropping out of these cooling flows.

White, Raymond E., III↗

Turbulence measurements in shock induced flows

Turbulence measurements have been made in the incident and reflected flows of a shock tube. For the incident flow, M = 0.47 and Re/in. between 25,000 and 170,000 whereas in the reflected region M = 0.15 and Re/in. is between 12,000 and 85,000. Hot wire anemometers have been used to measure mass flux and total temperature fluctuations. In the incident flow mass flux and total temperatures averaged 1.2 percent and 0.5 percent respectively. The reflected shock amplified the turbulence intensities by approximately a factor of three. In general the intensities decreased with increasing flow Reynolds numbers.

Trolier, J. W.↗

Numerical Speed of Sound and its Application to Schemes for all Speeds

The concept of "numerical speed of sound" is proposed in the construction of numerical flux. It is shown that this variable is responsible for the accurate resolution of' discontinuities, such as contacts and shocks. Moreover, this concept can he readily extended to deal with low speed and multiphase flows. As a results, the numerical dissipation for low speed flows is scaled with the local fluid speed, rather than the sound speed. Hence, the accuracy is enhanced the correct solution recovered, and the convergence rate improved. We also emphasize the role of mass flux and analyze the behavior of this flux. Study of mass flux is important because the numerical diffusivity introduced in it can be identified. In addition, it is the term common to all conservation equations. We show calculated results for a wide variety of flows to validate the effectiveness of using the numerical speed of sound concept in constructing the numerical flux. We especially aim at achieving these two goals: (1) improving accuracy and (2) gaining convergence rates for all speed ranges. We find that while the performance at high speed range is maintained, the flux now has the capability of performing well even with the low: speed flows. Thanks to the new numerical speed of sound, the convergence is even enhanced for the flows outside of the low speed range. To realize the usefulness of the proposed method in engineering problems, we have also performed calculations for complex 3D turbulent flows and the results are in excellent agreement with data.

Liou, Meng-Sing↗

Estimation of Heatshield Mass Loss for Mars 2020 Entry Vehicle

The Mars2020 entry vehicle is currently being developed by NASA to safely land its next rover on the Martian surface in 2021. During entry, the vehicle will be protected from aerothermal environments using a PICA (Phenolic Impregnated Carbon Ablator)-tiled heatshield. PICA loses mass through surface recession and in-depth pyrolysis as it is heated. Pre-flight knowledge of heatshield mass loss is required for vehicle balancing during critical mission events. This study attempts to predict the total mass loss experienced by the Mars2020's heatshield during its entry. A grid was created over the half of the heatshield which generated 108 points across a total of 9 spokes. Aero-thermal environments were provided from CFD (Computational Fluid Dynamics) calculations that considered a baselined trajectory. The TPS (Thermal Protection System) stack was a build-up of composite, aluminum, composite, an HT-424 bond, followed by PICA. The FIAT (Fully Implicit Ablation, Thermal-response) 1-D analysis utilized this TPS stack and the CFD environments and was run at each grid point giving mass flux information from the point of atmospheric entry until parachute deployment. The mass flux due to recession and pyrolysis gas was summed and integrated first through time and then across the half heatshield using a polar integration tool. The mass loss results were mirrored to the other half of the heatshield to calculate total mass loss throughout the entry phase of flight. This total mass loss value and its distribution was used by entry vehicle designers to account for CG (Center of Gravity) offset during parachute descent when the heatshield is no longer losing significant mass.

PICA↗

Effects of diabatic heating on the ageostrophic circulation of an upper tropospheric jet streak

Interaction between the mass circulation within a mesoscale convective complex (MCC) and a direct mass circulation in the entrance region of an upper tropospheric polar jet streak was examined within the isentropic structure to investigate mechanisms responsible for linking these two scales of motion. The results establish that latent heating in the MCC modifies the direct mass circulation in the jet streak entrance region through the diabatically induced components of ageostrophic motion analyzed within isentropic coordinates. Within the strong mesoscale mass circulation of each MCC, strong horizontal mass flux convergence into the MCC at low levels is balanced by strong horizontal mass flux divergence away from the convergence at upper levels. Locations of large diabatic heating rates correspond well to the MCC position for each case; diabatic heating forces the upward vertical branch for the mesoscale mass circulation.

Keyser, D. A.↗

Experimental investigation of an axisymmetric free jet with an initially uniform velocity profile

An experimental investigation was conducted to determine the flow characteristics of a circular free helium jet having an initially uniform velocity profile. Complete velocity profiles are presented at Reynolds numbers of 1027 and 4571 at 0, 3, 6, 10, 15, and 20 nozzle diameters (where possible) from the nozzle exit. Centerline velocity decay and potential core length were obtained over a range of Reynolds numbers from 155 to 5349 at distances up to and including 25 nozzle diameters from the nozzle exit. The angles of spread associated with the diffusion of the jet downstream of the nozzle are also given. Axial jet momentum flux and entrained mass flux, at various distances downstream of the nozzle, are presented as a function of the jet Reynolds number.

Labus, T. L.↗

Advanced Small Perturbation Potential Flow Theory for Unsteady Aerodynamic and Aeroelastic Analyses

An advanced small perturbation (ASP) potential flow theory has been developed to improve upon the classical transonic small perturbation (TSP) theories that have been used in various computer codes. These computer codes are typically used for unsteady aerodynamic and aeroelastic analyses in the nonlinear transonic flight regime. The codes exploit the simplicity of stationary Cartesian meshes with the movement or deformation of the configuration under consideration incorporated into the solution algorithm through a planar surface boundary condition. The new ASP theory was developed methodically by first determining the essential elements required to produce full-potential-like solutions with a small perturbation approach on the requisite Cartesian grid. This level of accuracy required a higher-order streamwise mass flux and a mass conserving surface boundary condition. The ASP theory was further developed by determining the essential elements required to produce results that agreed well with Euler solutions. This level of accuracy required mass conserving entropy and vorticity effects, and second-order terms in the trailing wake boundary condition. Finally, an integral boundary layer procedure, applicable to both attached and shock-induced separated flows, was incorporated for viscous effects. The resulting ASP potential flow theory, including entropy, vorticity, and viscous effects, is shown to be mathematically more appropriate and computationally more accurate than the classical TSP theories. The formulaic details of the ASP theory are described fully and the improvements are demonstrated through careful comparisons with accepted alternative results and experimental data. The new theory has been used as the basis for a new computer code called ASP3D (Advanced Small Perturbation - 3D), which also is briefly described with representative results.

Batina, John T.↗

Observational Diagnoses of Extratropical Ozone STE from 2005-2010

The transport of ozone from the stratosphere to the extratropical troposphere is an important boundary condition to tropospheric chemistry. However, previous direct estimates from models and indirect estimates from observations have poorly constrained the magnitude of ozone stratosphere-troposphere exchange (STE). In this study we provide a direct diagnosis of the extratropical ozone STE using data from the Microwave Limb Sounder on Aura and output of the MERRA reanalysis over the time period from 2005 to the present. We find that the mean annual STE is about 275 Tg yr-1 and 205 Tg yr-1 in the NH and SH, respectively. The interannual variability of the magnitude is about twice as great in the NH than the SH. This variability is dominated by the seasonal variability during the late winter and spring. A comparison of the ozone flux to the mass flux reveals that there is not a simple relationship between the two quantities. This presentation will also examine the magnitude and distribution of ozone in the lower stratosphere relative to the years of maximum and minimum ozone STE

Olsen, Mark A.↗