Improving z-tracking accuracy in the two-photon single-particle tracking microscope

Here, we present a method that can improve the z-tracking accuracy of the recently invented TSUNAMI (Tracking of Single particles Using Nonlinear And Multiplexed Illumination) microscope. This method utilizes a maximum likelihood estimator (MLE) to determine the particle's 3D position that maximizes the likelihood of the observed time-correlated photon count distribution. Our Monte Carlo simulations show that the MLE-based tracking scheme can improve the z-tracking accuracy of TSUNAMI microscope by 1.7 fold. In addition, MLE is also found to reduce the temporal correlation of the z-tracking error. Taking advantage of the smaller and less temporally correlated z-tracking error, we have precisely recovered the hybridization-melting kinetics of a DNA model system from thousands of short single-particle trajectories in silico. Our method can be generally applied to other 3D single-particle tracking techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

UVUDF: UV Luminosity Functions at the Cosmic High Noon

We present the rest-1500 Å UV luminosity functions (LF) for star-forming galaxies during the cosmic high noon—the peak of cosmic star formation rate at 1.5<z<3. We use deep NUV imaging data obtained as part of the Hubble Ultra-Violet Ultra Deep Field (UVUDF) program, along with existing deep optical and NIR coverage on the HUDF. We select F225W, F275W, and F336W dropout samples using the Lyman break technique, along with samples in the corresponding redshift ranges selected using photometric redshifts, and measure the rest-frame UV LF at z∼1.7,2.2,3.0, respectively, using the modified maximum likelihood estimator. We perform simulations to quantify the survey and sample incompleteness for the UVUDF samples to correct the effective volume calculations for the LF. We select galaxies down to M{sub UV}=−15.9,−16.3,−16.8 and fit a faint-end slope of α=−1.20{sub −0.13}{sup +0.10},−1.32{sub −0.14}{sup +0.10},−1.39{sub −0.12}{sup +0.08} at 1.4<z<1.9, 1.8<z<2.6, and 2.4<z<3.6, respectively. We compare the star formation properties of z∼2 galaxies from these UV observations with results from Hα and UV+IR observations. We find a lack of high-SFR sources in the UV LF compared to the Hα and UV+IR, likely due to dusty SFGs not being properly accounted for by the generic IRX--β relation used to correct for dust. We compute a volume-averaged UV-to-Hα ratio by abundance matching the rest-frame UV LF and Hα LF. We find an increasing UV-to-Hα ratio toward low-mass galaxies (M{sub ⋆}≲5×10{sup 9} M{sub ⊙}). We conclude that this could be due to a larger contribution from starbursting galaxies compared to the high-mass end.

79 ASTRONOMY AND ASTROPHYSICS↗

Flexible nonstationary spatiotemporal modeling of high-frequency monitoring data

Many physical datasets are generated by collections of instruments that make measurements at regular time intervals. For such regular monitoring data, we extend the framework of half-spectral covariance functions to the case of nonstationarity in space and time and demonstrate that this method provides a natural and tractable way to incorporate complex behaviors into a covariance model. Further, we use this method with fully time-domain computations to obtain bona fide maximum likelihood estimators—as opposed to using Whittle-type likelihood approximations, for example—that can still be computed conveniently. Additionally, we apply this method to very high-frequency Doppler LIDAR vertical wind velocity measurements, demonstrating that the model can expressively capture the extreme nonstationarity of dynamics above and below the atmospheric boundary layer and, more importantly, the interaction of the process dynamics across it.

54 ENVIRONMENTAL SCIENCES↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Learning generative neural networks with physics knowledge

Deep generative neural networks have enabled modeling complex distributions, but incorporating physics knowledge into the neural networks is still challenging and is at the core of current physics-based machine learning research. To this end, we propose a physics generative neural network (PhysGNN), a new class of generative neural networks for learning unknown distributions in a physical system described by partial differential equations (PDE). PhysGNN couples PDE systems with generative neural networks. It is a fully differentiable model that allows back-propagation of gradients through both numerical PDE solvers and generative neural networks, and is trained by minimizing the discrete Wasserstein distance between generated and observed probability distributions of the PDE outputs using the stochastic gradient descent method. Moreover, PhysGNN does not require adversarial training like standard generative neural networks, which offers better stability than adversarial training. We show that PhysGNN can learn complex distributions in stochastic inverse problems, where conventional methods such as maximum likelihood estimation and momentum matching methods may be inapplicable when little knowledge is known about the form of unknown distributions or the physical model is too complex. Furthermore, our method allows physics-based generative neural network training for learning complex distributions in the context of differential equations.

97 MATHEMATICS AND COMPUTING↗

Latent map Gaussian processes for mixed variable metamodeling

Gaussian processes (GPs) are ubiquitously used in sciences and engineering as metamodels. Standard GPs, however, can only handle numerical or quantitative variables. Here we introduce latent map Gaussian processes (LMGPs) that inherit the attractive properties of GPs and are also applicable to mixed data which have both quantitative and qualitative inputs. The core idea behind LMGPs is to learn a continuous, low-dimensional latent space or manifold which encodes all qualitative inputs. To learn this manifold, we first assign a unique prior vector representation to each combination of qualitative inputs. We then use a low-rank linear map to project these priors on a manifold that characterizes the posterior representations. As the posteriors are quantitative, they can be directly used in any standard correlation function such as the Gaussian or Matern. Hence, the optimal map and the corresponding manifold, along with other hyperparameters of the correlation function, can be systematically learned via maximum likelihood estimation. Through a wide range of analytic and real-world examples, we demonstrate the advantages of LMGPs over state-of-the-art methods in terms of accuracy and versatility. In particular, we show that LMGPs can handle variable-length inputs, have an explainable neural network interpretation, and provide insights into how qualitative inputs affect the response or interact with each other. We also employ LMGPs in Bayesian optimization and illustrate that they can discover optimal compound compositions more efficiently than conventional methods that convert compositions to qualitative variables via manual featurization.

42 ENGINEERING↗

The Radiation Dose-Response of the Human Spinal Cord

Purpose: To characterize the radiation dose-response of the human spinal cord. Methods and Materials: Because no single institution has sufficient data to establish a dose-response function for the human spinal cord, published reports were combined. Requisite data were dose and fractionation, number of patients at risk, number of myelopathy cases, and survival experience of the population. Eight data points for cervical myelopathy were obtained from five reports. Using maximum likelihood estimation correcting for the survival experience of the population, estimates were obtained for the median tolerance dose, slope parameter, and {alpha}/{beta} ratio in a logistic dose-response function. An adequate fit to thoracic data was not possible. Hyperbaric oxygen treatments involving the cervical cord were also analyzed. Results: The estimate of the median tolerance dose (cervical cord) was 69.4 Gy (95% confidence interval, 66.4-72.6). The {alpha}/{beta} = 0.87 Gy. At 45 Gy, the (extrapolated) probability of myelopathy is 0.03%; and at 50 Gy, 0.2%. The dose for a 5% myelopathy rate is 59.3 Gy. Graphical analysis indicates that the sensitivity of the thoracic cord is less than that of the cervical cord. There appears to be a sensitizing effect from hyperbaric oxygen treatment. Conclusions: The estimate of {alpha}/{beta} is smaller than usually quoted, but values this small were found in some studies. Using {alpha}/{beta} = 0.87 Gy, one would expect a considerable advantage by decreasing the dose/fraction to less than 2 Gy. These results were obtained from only single fractions/day and should not be applied uncritically to hyperfractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elective Clinical Target Volumes for Conformal Therapy in Anorectal Cancer: A Radiation Therapy Oncology Group Consensus Panel Contouring Atlas

Purpose: To develop a Radiation Therapy Oncology Group (RTOG) atlas of the elective clinical target volume (CTV) definitions to be used for planning pelvic intensity-modulated radiotherapy (IMRT) for anal and rectal cancers. Methods and Materials: The Gastrointestinal Committee of the RTOG established a task group (the nine physician co-authors) to develop this atlas. They responded to a questionnaire concerning three elective CTVs (CTVA: internal iliac, presacral, and perirectal nodal regions for both anal and rectal case planning; CTVB: external iliac nodal region for anal case planning and for selected rectal cases; CTVC: inguinal nodal region for anal case planning and for select rectal cases), and to outline these areas on individual computed tomographic images. The imaging files were shared via the Advanced Technology Consortium. A program developed by one of the co-authors (I.E.N.) used binomial maximum-likelihood estimates to generate a 95% group consensus contour. The computer-estimated consensus contours were then reviewed by the group and modified to provide a final contouring consensus atlas. Results: The panel achieved consensus CTV definitions to be used as guidelines for the adjuvant therapy of rectal cancer and definitive therapy for anal cancer. The most important difference from similar atlases for gynecologic or genitourinary cancer is mesorectal coverage. Detailed target volume contouring guidelines and images are discussed. Conclusion: This report serves as a template for the definition of the elective CTVs to be used in IMRT planning for anal and rectal cancers, as part of prospective RTOG trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multivariate degradation modeling using generalized cauchy process and application in life prediction of dye-sensitized solar cells

Recently, the Generalized Cauchy (GC) process has been applied to capture a Long Memory (LM) phenomenon in product degradation modeling and life prediction. Compared with the traditional fractional Brownian motion that captures the LM using a single Hurst parameter, the GC process has two free parameters (Hurst and fractal dimension parameters) that flexibly capture both global LM and local irregularity. However, all existing GC-based degradation models are for a single Degradation Characteristic (DC). In this article, motivated by a real degradation problem of dye-sensitized solar cells that jointly exhibits multiple DCs, global LM, local irregularity and DC-wise cross-correlation, we propose a novel GC-based Multivariate Degradation Model (GC-MDM) to simultaneously capture the aforementioned effects. A maximum likelihood estimation approach is developed to estimate parameters of the GC-MDM. Subsequently, product life prediction based on the GC-MDM is developed. The proposed GC-MDM is validated through a simulation study and a physical experiment of dye-sensitized solar cells. Furthermore, results show that the proposed GC-MDM fundamentally improves the life prediction accuracy in comparison with conventional degradation models which significantly misestimate the uncertainty of product life.

14 SOLAR ENERGY↗

Process Modeling and Techno-Economic Analysis of a CO 2 Capture Process Using Fixed Bed Reactors with a Microencapsulated Solvent

A detailed model of a capsule containing sodium carbonate solution is developed here to study the microencapsulated carbon capture solvents (MECS). A rigorous vapor–liquid equilibrium model is developed for the Na 2 CO 3 –CO 2 –H 2 O system, where liquid-phase nonideality is modeled by the electrolyte nonrandom two-liquid model. The data from the experiments conducted at the Lawrence Livermore National Laboratory is used to obtain a maximum likelihood estimate of the initial solvent concentration inside the capsules and the parameters for the capsule model. A nonisothermal, dynamic model of a fixed bed contactor filled with these capsules is then developed. In addition to direct steam injection, indirect heating using an embedded heat exchanger is modeled for desorption. Finally, the model is used to simulate temperature swing absorption and desorption cycles. The results of these studies indicate that there is an optimal residence time or superficial flue gas velocity to minimize the bed volume. However, the total energy requirement for desorption monotonically decreases with increased residence time as the proportion of the sensible heat to the total regeneration heat keeps decreasing. Furthermore, heat recovery from the bed is crucial to keep energy penalty for regeneration low. A techno-economic analysis is conducted, and the equivalent annual operating cost (EAOC) is analyzed for two different reactor materials (concrete and carbon-steel) and compared with a system using a conventional monoethanolamine (MEA) solvent. In this work, the minimum EAOC for the MECS fixed bed configuration is approximately 1.8–2.7 times higher than the EAOC for an MEA system with a similar amount of heat recovery (85%). The impact of ±50% uncertainty in the capital cost estimate is also evaluated, and the minimum EAOC is 1.5 times higher than the MEA technology for 85% heat recovery. These results using microencapsulated sodium carbonate solution are a starting point that sets an upper limit on the cost of the MECS carbon-capture system. Improvements to the MECS capsules (e.g., using a higher carbonate concentration and lowering the shell mass transfer resistance) and also exploring other contactor technologies are expected to decrease the system cost and make it more competitive.

20 FOSSIL-FUELED POWER PLANTS↗

Simultaneous Dependence of the Earthquake-Size Distribution on Faulting Style and Depth

We analyze two high-quality Southern Californian earthquake catalogues, one with focal mechanisms, to statistically model and test for dependencies of the earthquake-size distribution, the b values, on both faulting style and depth. In our null hypothesis, b is assumed constant. We then develop and calibrate one model based only on faulting style, another based only on depth dependence and two models that assume a simultaneous dependence on both parameters. We develop a new maximum-likelihood estimator corrected for the degrees of freedom to assess models' performances. Our results show that all models significantly reject the null hypothesis. The best performing is the one that simultaneously takes account of depth and faulting style. Our results suggest that differential stress variations in the Earth's crust systematically influence b values and that this variability should be considered for contemporary seismic hazard studies.

54 ENVIRONMENTAL SCIENCES↗

Information-rich localization microscopy through machine learning

Recent years have witnessed the development of single-molecule localization microscopy as a generic tool for sampling diverse biologically relevant information at the super-resolution level. While current approaches often rely on the target-specific alteration of the point spread function to encode the multidimensional contents of single fluorophores, the details of the point spread function in an unmodified microscope already contain rich information. Here we introduce a data-driven approach in which artificial neural networks are trained to make a direct link between an experimental point spread function image and its underlying, multidimensional parameters, and compare results with alternative approaches based on maximum likelihood estimation. To demonstrate this concept in real systems, we decipher in fixed cells both the colors and the axial positions of single molecules in regular localization microscopy data.

42 ENGINEERING↗

Nucleation Rate Analysis of Methane Hydrate from Molecular Dynamics Simulations

Clathrate hydrates are solid crystalline structures most commonly formed from solutions that have nucleated to form a mixed solid composed of water and gas. Understanding the mechanism of clathrate hydrate nucleation is essential to grasp the fundamental chemistry of these complex structures and their applications. Molecular dynamics (MD) simulation is an ideal method to study nucleation at the molecular level because the size of the critical nucleus and formation rate occur on the nano scale. Moreover, various analysis methods for nucleation have been developed through MD to analyze nucleation. In particular, the mean first-passage time (MFPT) and survival probability (SP) methods have proven to be effective in procuring the nucleation rate and critical nucleus size for monatomic systems. This study assesses the MFPT and SP methods, previously used for monatomic systems, when applied to analyzing clathrate hydrate nucleation. Because clathrate hydrate nucleation is relatively difficult to observe in MD simulations (due to its high free energy barrier), these methods have yet to be applied to clathrate hydrate systems. In this study, we have analyzed the nucleation rate and critical nucleus size of methane hydrate using MFPT and SP methods from data generated by MD simulations at 255 K and 50 MPa. MFPT was modified for clathrate hydrate from the original version by adding the maximum likelihood estimate and growth effect term. The nucleation rates were calculated by MFPT and SP methods and are within 5%; the critical nucleus size estimated by the MFPT method was 50% higher, than values obtained through other more rigorous but computationally expensive estimates. These methods can also be extended to the analysis of other clathrate hydrates.

59 BASIC BIOLOGICAL SCIENCES↗

The one-dimensional Ly α forest power spectrum from BOSS

For this research, we have developed two independent methods for measuring the one-dimensional power spectrum of the transmitted flux in the Lyman-α forest. The first method is based on a Fourier transform and the second on a maximum-likelihood estimator. The two methods are independent and have different systematic uncertainties. Determination of the noise level in the data spectra was subject to a new treatment, because of its significant impact on the derived power spectrum. We applied the two methods to 13 821 quasar spectra from SDSS-III/BOSS DR9 selected from a larger sample of over 60 000 spectra on the basis of their high quality, high signal-to-noise ratio (S/N), and good spectral resolution. The power spectra measured using either approach are in good agreement over all twelve redshift bins from = 2.2 to = 4.4, and scales from 0.001 km s -1 to 0.02 km s -1 . We determined the methodological andinstrumental systematic uncertainties of our measurements. We provide a preliminary cosmological interpretation of our measurements using available hydrodynamical simulations. The improvement in precision over previously published results from SDSS is a factor 2–3 for constraints on relevant cosmological parameters. For a ΛCDM model and using a constraint on H 0 that encompasses measurements based on the local distance ladder and on CMB anisotropies, we infer σ 8 = 0.83 ± 0.03 and n s = 0.97 ± 0.02 based on H i absorption in the range 2.1 < z < 3.7.

79 ASTRONOMY AND ASTROPHYSICS↗

Cross-correlation image analysis for real-time single particle tracking

Accurately measuring the translations of objects between images is essential in many fields, including biology, medicine, chemistry, and physics. One important application is tracking one or more particles by measuring their apparent displacements in a series of images. Popular methods, such as the center of mass, often require idealized scenarios to reach the shot noise limit of particle tracking and, therefore, are not generally applicable to multiple image types. More general methods, such as maximum likelihood estimation, reliably approach the shot noise limit, but are too computationally intense for use in real-time applications. These limitations are significant, as real-time, shot-noise-limited particle tracking is of paramount importance for feedback control systems. To fill this gap, we introduce a new cross-correlation-based algorithm that approaches shot-noise-limited displacement detection and a graphics processing unit-based implementation for real-time image analysis of a single particle.

Instruments & Instrumentation↗

Analysis of overlapping count data

Counts of a specific characteristic were obtained within regions defined on an object that was manufactured in a proprietary setting. The count regions were altered during production and resulted in misaligned or overlapping count data. A closed-formula maximum likelihood estimator (MLE) of the new region means is derived using all of the available count data and an independent Poisson model. The MLE is shown to be preferable to estimators constructed using generalized linear models for the overlapping data setting. This closed-form estimator extends to over-dispersed overlapping count data as the quasi-MLE and also performs well with correlated overlapping count data. Standard errors for the estimator are approximated and are validated with a simulation study. Additionally, the methods are extended to overlapping multinomial data. Illustrative examples of the methods are provided throughout the paper and are reproducible with the supplemental R code. Additionally, proofs of the paper’s results are also included in the supplemental material.

97 MATHEMATICS AND COMPUTING↗

Tensor decompositions for count data that leverage stochastic and deterministic optimization

There is growing interest to extend low-rank matrix decompositions to multi-way arrays, or tensors. One fundamental low-rank tensor decomposition is the canonical polyadic decomposition (CPD). The challenge of fitting a low-rank, nonnegative CPD model to Poisson-distributed count data is of particular interest. Several popular algorithms use local search methods to approximate the maximum likelihood estimator (MLE) of the Poisson CPD model. Here, this work presents two new algorithms that extend state-of-the-art local methods for Poisson CPD. Hybrid GCP-CPAPR combines Generalized Canonical Decomposition (GCP) with stochastic optimization and CP Alternating Poisson Regression (CPAPR), a deterministic algorithm, to increase the probability of converging to the MLE over either method used alone. Restarted CPAPR with SVDrop uses a heuristic based on the singular values of the CPD model unfoldings to identify convergence toward optimizers that are not the MLE and restarts within the feasible domain of the optimization problem, thus reducing overall computational cost when using a multi-start strategy. We provide empirical evidence that indicates our approaches outperform existing methods with respect to converging to the Poisson CPD MLE.

CPAPR↗