Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Estimation of terrain iso-gradients from a stochastic range data measurement matrix

The problem of estimating terrain iso-gradients for an autonomous roving vehicle is complicated by the measurement error inherent in the range data matrix. In this paper, the in-path and cross-path slopes at each data point in the multivariable range matrix are expressed in terms of parameters at that data point and those at its surrounding points. The sensitivity in the change of these slopes - due to the errors in measurements in range, elevation angle and azimuth angle are formulated. These sensitivities are used to determine the appropriate statistics of the gradient, which are then used to describe the terrain with a known probability of accuracy.

Shen, C. N.↗

Hypersonic Wind Tunnels: Latest Citations from the Aerospace Database

The bibliography contains citations concerning the design, construction, operation, performance, and use of hypersonic wind tunnels. References cover the design of flow nozzles, diffusers, test sections, and ejectors for tunnels driven by compressed air, high-pressure gases, or cryogenic liquids. Methods for flow calibration, boundary layer control, local and freestream turbulence reduction, and force measurement are discussed. Intrusive and non-intrusive instrumentation, sources of measurement error, and measurement corrections are also covered. The citations also include the testing of inlets, nozzles, airfoils, and other components of hypersonic aerospace vehicles. Comprehensive coverage of supersonic and blowdown wind tunnels, and force balance systems for wind tunnels are covered in separate bibliographies.

BIBLIOGRAPHIES↗

Supersonic Wind Tunnels (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning the design, construction, operation, performance, and use of supersonic wind tunnels. References cover the design of flow nozzles, diffusers, test sections, and ejectors for tunnels driven by compressed air, high-pressure gases, or cryogenic liquids. Methods for flow calibration, boundary layer control, local and freestream turbulence reduction, and force measurement are discussed. Instrusive and non-intrusive instrumentation, sources of measurement error, and measurement corrections are also covered. The citations also include the testing of inlets, nozzles, airfoils, and other components of aerospace vehicles that must operate supersonically. Comprehensive coverage of wind tunnel force balancing systems, and blowdown and supersonic wind tunnels are covered in separate bibliographies.(Contains 50-250 citations and includes a subject term index and title list.)

WIND TUNNELS↗

Measurement of Error Vector Magnitude (EVM) to Characterize the Impairment of the Tracking and Data Relay Satellite (TDRS) Channel

A digital signal is transmitted via a carrier wave, it demodulates at a receiver, and locates at an ideal constellation point. However, noise distortion, carrier leakage, and phase noise can force a signal to divert from its ideal position to a new position. Consequently, the performance of the signal is decreased. Bit Error Rate (BER) and Error Vector Magnitude (EVM) measurement techniques are used to enable the analysis and assessment of the extent to which the performance of a signal has been decreased. In this paper, we present the EVM measurement technique as a figure of merit to analyze and evaluate the performance of a User Services Subsystem Component Replacement (USSCR) modem. Also, we demonstrate the use of the EVM measurement technique in a Tracking and Data Relay Satellite (TDRS) system to measure and evaluate channel impairment between a satellite (transmitter) and the ground terminal (receiver) at the White Sands Complex.

Spacecraft RF Communications↗

Bit error rate measurement above and below bit rate tracking threshold

Bit error rate is measured by sending a pseudo-random noise (PRN) code test signal simulating digital data through digital equipment to be tested. An incoming signal representing the response of the equipment being tested, together with any added noise, is received and tracked by being compared with a locally generated PRN code. Once the locally generated PRN code matches the incoming signal a tracking lock is obtained. The incoming signal is then integrated and compared bit-by-bit against the locally generated PRN code and differences between bits being compared are counted as bit errors.

Kobayaski, H. S.↗

Pre-Test Assessment of the Upper Bound of the Drag Coefficient Repeatability of a Wind Tunnel Model

A new method is presented that computes a pre{test estimate of the upper bound of the drag coefficient repeatability of a wind tunnel model. This upper bound is a conservative estimate of the precision error of the drag coefficient. For clarity, precision error contributions associated with the measurement of the dynamic pressure are analyzed separately from those that are associated with the measurement of the aerodynamic loads. The upper bound is computed by using information about the model, the tunnel conditions, and the balance in combination with an estimate of the expected output variations as input. The model information consists of the reference area and an assumed angle of attack. The tunnel conditions are described by the Mach number and the total pressure or unit Reynolds number. The balance inputs are the partial derivatives of the axial and normal force with respect to all balance outputs. Finally, an empirical output variation of 1.0 microV/V is used to relate both random instrumentation and angle measurement errors to the precision error of the drag coefficient. Results of the analysis are reported by plotting the upper bound of the precision error versus the tunnel conditions. The analysis shows that the influence of the dynamic pressure measurement error on the precision error of the drag coefficient is often small when compared with the influence of errors that are associated with the load measurements. Consequently, the sensitivities of the axial and normal force gages of the balance have a significant influence on the overall magnitude of the drag coefficient's precision error. Therefore, results of the error analysis can be used for balance selection purposes as the drag prediction characteristics of balances of similar size and capacities can objectively be compared. Data from two wind tunnel models and three balances are used to illustrate the assessment of the precision error of the drag coefficient.

drag coefficient measurement↗

Simulation–Extrapolation for Bias Correction with Exposure Uncertainty in Radiation Risk Analysis Utilizing Grouped Data

Summary In observational epidemiological studies, the exposure that is received by an individual often cannot be precisely observed, resulting in measurement error, and a common approach to dealing with measurement error is regression calibration (RC). Use of RC, which requires assumptions about the distribution of unknown error-free (true) variables, leads to concern about the possibility of bias due to misspecification of that distribution. The simulation–extrapolation (SIMEX) method, in contrast, does not require a distributional assumption. However, analyses of large cohorts may be performed by using grouped or person-year data, and application of SIMEX to grouped data is not straightforward, particularly when there is a mixture of classical and Berkson measurement errors. We compared RC and SIMEX with grouped data analyses to assess robustness of the RC method to misspecification of the true dose distribution. We also applied SIMEX assuming mixtures of classical and Berkson errors and compared the results with those obtained by using RC for classical error only. SIMEX had less bias than RC and performed well regardless of the true dose distribution, whereas RC based on a misspecified true dose distribution showed greater bias than when based on the correctly specified true dose distribution.

Misumi, Munechika↗

Reduction of quantization error in measurement of frequency

Method reduces quantization errors using new digital circuit. Circuit provides very high resolution (10 to the minus 2nd power to 10 to the minus 3rd power Hz) without high-speed counters. It lends itself to microminaturization and is simple to construct. Unknown frequency is compared to standard frequency by means of zero-crossing coincidence-detecting circuit.

Nossen, E. J.↗

Estimation of bias errors in measured airplane responses using maximum likelihood method

A maximum likelihood method is used for estimation of unknown bias errors in measured airplane responses. The mathematical model of an airplane is represented by six-degrees-of-freedom kinematic equations. In these equations the input variables are replaced by their measured values which are assumed to be without random errors. The resulting algorithm is verified with a simulation and flight test data. The maximum likelihood estimates from in-flight measured data are compared with those obtained by using a nonlinear-fixed-interval-smoother and an extended Kalmar filter.

Klein, Vladiaslav↗

Precise method of compensating radiation-induced errors in a hot-cathode-ionization gauge with correcting electrode

To compensate pressure-measurement errors caused by a synchrotron radiation environment, a precise method using a hot-cathode-ionization-gauge head with correcting electrode, was developed and tested in a simulation experiment with excess electrons in the SPring-8 storage ring. This precise method to improve the measurement accuracy, can correctly reduce the pressure-measurement errors caused by electrons originating from the external environment, and originating from the primary gauge filament influenced by spatial conditions of the installed vacuum-gauge head. As the result of the simulation experiment to confirm the performance reducing the errors caused by the external environment, the pressure-measurement error using this method was approximately less than several percent in the pressure range from 10{sup −5} Pa to 10{sup −8} Pa. After the experiment, to confirm the performance reducing the error caused by spatial conditions, an additional experiment was carried out using a sleeve and showed that the improved function was available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of narrow band control to reduce vibrations in magnetic bearing systems

The benefits of narrowband control theory for simple, open-loop stable systems are illustrated, and how the approach changes for magnetic bearing systems, which are open-loop unstable, is discussed. Magnetic bearing systems are good applications for narrowband control theory. Two sources of synchronous forces, the measurement error and the magnetic unbalance, are discussed. Both the measurement error and the magnetic unbalance manifest themselves as synchronous disturbances. It is shown that narrowband control theory for simple, open-loop stable systems provides excellent performance and good stability robustness. Because magnetic bearing systems are open-loop stable, the narrowband control approach becomes more complex. Disturbance accommodating control (DAC) theory is introduced as an effective approach to reduce vibrations in magnetic bearing systems. It is used to develop a control/estimation scheme that enables the rotor to spin about its center of mass in the presence of the measurement error disturbances.

Gaffney, Monique S.↗

ON ESTIMATING FORCE-FREENESS BASED ON OBSERVED MAGNETOGRAMS

It is a common practice in the solar physics community to test whether or not measured photospheric or chromospheric vector magnetograms are force-free, using the Maxwell stress as a measure. Some previous studies have suggested that magnetic fields of active regions in the solar chromosphere are close to being force-free whereas there is no consistency among previous studies on whether magnetic fields of active regions in the solar photosphere are force-free or not. Here we use three kinds of representative magnetic fields (analytical force-free solutions, modeled solar-like force-free fields, and observed non-force-free fields) to discuss how measurement issues such as limited field of view (FOV), instrument sensitivity, and measurement error could affect the estimation of force-freeness based on observed magnetograms. Unlike previous studies that focus on discussing the effect of limited FOV or instrument sensitivity, our calculation shows that just measurement error alone can significantly influence the results of estimates of force-freeness, due to the fact that measurement errors in horizontal magnetic fields are usually ten times larger than those in vertical fields. This property of measurement errors, interacting with the particular form of a formula for estimating force-freeness, would result in wrong judgments of the force-freeness: a truly force-free field may be mistakenly estimated as being non-force-free and a truly non-force-free field may be estimated as being force-free. Our analysis calls for caution when interpreting estimates of force-freeness based on measured magnetograms, and also suggests that the true photospheric magnetic field may be further away from being force-free than it currently appears to be.

79 ASTRONOMY AND ASTROPHYSICS↗

Error field measurements and correction on MUSE permanent magnet stellarator

The magnetic field topology and error fields are measured in the MUSE permanent magnet stellarator with an electron beam and fluorescent rod. The effective magnetization of the magnets is determined by measuring rational flux surface locations. Electron magnetic drift effects must be considered self-consistently due to the small magnetic shear on MUSE. Error fields are characterized by flux surface shape deviation and magnetic island chain width and phase. Error fields are then corrected by adjusting the permanent magnet (PM) holders as rigid bodies. Resonant error fields are on the order of or smaller than 3 x 10 -6 of the toroidal field after correction and surface shape matches well with the design. Resonant components of the quasi-symmetry deviation are estimated, using a novel magnetic drift measurement, to be in the 10 −4 range. The PM approach is validated as a low-cost and precise way to build optimized stellarators.

electron beam mapping↗

An analysis of estimation of pulmonary blood flow by the single-breath method

The single-breath method represents a simple noninvasive technique for the assessment of capillary blood flow across the lung. However, this method has not gained widespread acceptance, because its accuracy is still being questioned. A rigorous procedure is described for estimating pulmonary blood flow (PBF) using data obtained with the aid of the single-breath method. Attention is given to the minimization of data-processing errors in the presence of measurement errors and to questions regarding a correction for possible loss of CO2 in the lung tissue. It is pointed out that the estimations are based on the exact solution of the underlying differential equations which describe the dynamics of gas exchange in the lung. The reported study demonstrates the feasibility of obtaining highly reliable estimates of PBF from expiratory data in the presence of random measurement errors.

Srinivasan, R.↗

Adaptive Error Estimation in Linearized Ocean General Circulation Models

Data assimilation methods are routinely used in oceanography. The statistics of the model and measurement errors need to be specified a priori. This study addresses the problem of estimating model and measurement error statistics from observations. We start by testing innovation based methods of adaptive error estimation with low-dimensional models in the North Pacific (5-60 deg N, 132-252 deg E) to TOPEX/POSEIDON (TIP) sea level anomaly data, acoustic tomography data from the ATOC project, and the MIT General Circulation Model (GCM). A reduced state linear model that describes large scale internal (baroclinic) error dynamics is used. The methods are shown to be sensitive to the initial guess for the error statistics and the type of observations. A new off-line approach is developed, the covariance matching approach (CMA), where covariance matrices of model-data residuals are "matched" to their theoretical expectations using familiar least squares methods. This method uses observations directly instead of the innovations sequence and is shown to be related to the MT method and the method of Fu et al. (1993). Twin experiments using the same linearized MIT GCM suggest that altimetric data are ill-suited to the estimation of internal GCM errors, but that such estimates can in theory be obtained using acoustic data. The CMA is then applied to T/P sea level anomaly data and a linearization of a global GFDL GCM which uses two vertical modes. We show that the CMA method can be used with a global model and a global data set, and that the estimates of the error statistics are robust. We show that the fraction of the GCM-T/P residual variance explained by the model error is larger than that derived in Fukumori et al.(1999) with the method of Fu et al.(1993). Most of the model error is explained by the barotropic mode. However, we find that impact of the change in the error statistics on the data assimilation estimates is very small. This is explained by the large representation error, i.e. the dominance of the mesoscale eddies in the T/P signal, which are not part of the 21 by 1" GCM. Therefore, the impact of the observations on the assimilation is very small even after the adjustment of the error statistics. This work demonstrates that simult&neous estimation of the model and measurement error statistics for data assimilation with global ocean data sets and linearized GCMs is possible. However, the error covariance estimation problem is in general highly underdetermined, much more so than the state estimation problem. In other words there exist a very large number of statistical models that can be made consistent with the available data. Therefore, methods for obtaining quantitative error estimates, powerful though they may be, cannot replace physical insight. Used in the right context, as a tool for guiding the choice of a small number of model error parameters, covariance matching can be a useful addition to the repertory of tools available to oceanographers.

Chechelnitsky, Michael Y.↗

A Non-Intrusive Optical (NIO) Method to Measure Optical Errors of in-situ Heliostats in Utility-Scale Power Tower Plants: Detecting Uncertainties in Heliostat Geometry

Heliostat optical errors can account for significant losses in efficiency of power tower concentrating solar power (CSP) plants. Accurately measuring heliostat optical errors can help to improve plant performance. A Non-Intrusive Optical (NIO) method has been developed to efficiently measure heliostat optical errors from UAS collected images of the mirror surface reflection [1]–[3]. In some cases, plant data of heliostat geometry can be incomplete or contain inaccuracies, in which case field collected data can be used to detect and correct uncertainties, which is valuable information for plant operators.

Mitchell, Rebecca↗