Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Insight to the Duration of 120 °C Baking on the Performance of SRF Niobium Cavities

Low-temperature baking at 100 °C - 140 °C in ultra-high vacuum for several hours is the final cavity processing technique to achieve the highest accelerating gradient cavity by eliminating the high field Q-slope, typically on cavities made of high purity fine grain niobium and subjected to electropolishing. The temperature and duration of baking control the onset of the high field Q-slope and overall quality factor over the baseline measurements. The increase in quality factor is generally related to the reduction in the temperature-dependent surface resistance, which refers to BCS surface resistance due to the reduction in the electronic mean free path and elimination of high field Q-slope is still being actively investigated. Here, we present the results of a series of measurements on 1.3 GHz TESLA shape single-cell cavities with successive low-temperature baking at 120 °C up to 96 hours. The rf loss related to the trapping of residual magnetic field refer to flux trapping sensitivity was measured with respect to the duration of 120 °C bake.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of environmental backgrounds on atmospheric monitoring of nuclear explosions

Radionuclide monitoring for nuclear explosions includes measuring radioactive aerosol and noble gas concentrations in the atmosphere. The International Monitoring System (IMS) of the Comprehensive Nuclear Test Ban Treaty (CTBT) has made such measurements for decades, revealing much about how atmospheric radioactivity impacts the sensitivity of the network. For example, civilian emissions of radioiodine make a substantial regional impact, but a minor global impact, while civilian radioxenon emissions create major regional and complex global impacts. This example statement is strongly influenced by the minimum signal level anticipated to be interesting. The original design of the IMS anticipated relatively large signal levels, and the accomplished IMS network substantially meets or exceeds the sensitivity needed to detect those signal levels. Much lower signal levels can be motivated, which could require reconsideration of station sensitivity. Using measured and simulated background concentrations, various possible desired signal levels, and an innovative anomaly threshold, maps of sensitivity and a station ranking are developed for current and future stations. These provide a strong motivation for additional experimentation to learn about sources and the potential plusses of new technology.

Eslinger, Paul W.↗

Polarized X-ray scattering measures molecular orientation in polymer-grafted nanoparticles

Polymer chains are attached to nanoparticle surfaces for many purposes, including altering solubility, influencing aggregation, dispersion, and even tailoring immune responses in drug delivery. The most unique structural motif of polymer-grafted nanoparticles (PGNs) is the high-density region in the corona where polymer chains are stretched under significant confinement, but orientation of these chains has never been measured because conventional nanoscale-resolved measurements lack sensitivity to polymer orientation in amorphous regions. Here, we directly measure local chain orientation in polystyrene grafted gold nanoparticles using polarized resonant soft X-ray scattering (P-RSoXS). Using a computational scattering pattern simulation approach, we measure the thickness of the anisotropic region of the corona and extent of chain orientation within it. These results demonstrate the power of P-RSoXS to discover and quantify orientational aspects of structure in amorphous soft materials and provide a framework for applying this emerging technique to more complex, chemically heterogeneous systems in the future.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quadrupole wiggler for a collinear wakefield accelerator

A quadrupole wiggler consisting of a row of alternating-polarity permanent magnet-excited quadrupoles is used in a collinear wakefield accelerator under development at Argonne National Laboratory. Fine translational and angular adjustment mechanisms are implemented in all quadrupoles to obtain a better than 1−μ⁢m precision in the alignment of quadrupole wiggler assemblies. The quadrupole’s magnetic and mechanical designs are described. Two wiggler prototypes were fabricated, aligned, and characterized performing pulsed wire magnetic measurements. The sensitivity of the quadrupole wiggler alignment to the ambient temperature was measured.

43 PARTICLE ACCELERATORS↗

Joint inversion of electromagnetic measurements for the determination of water saturation profiles in concrete structures

Highlights: • DC-electrical and dielectric data are combined to estimate concrete saturation degree. • A joint inversion approach of the electromagnetic measurements is proposed. • The sensitivity of the measurements to the saturation model parameters is analysed. • The new joint approach was developed and is applied to synthetic and real data. • The benefits of the joint approach over the inversion of one data type are highlighted. Water saturation profiles in concrete are essential to assess its durability and can be determined using non-destructive techniques, especially the electric and the capacitive methods. In this paper, we propose a new inversion scheme where both resistivity and permittivity measurements are inverted jointly to retrieve the saturation profile. The finite element method is used to model the measurements in 3D, the concrete having a saturation profile with depth, represented by a continuous model taking the form of a Weibull curve with four parameters. A non-linear least-squares optimization based on the Levenberg-Marquardt scheme is developed for the inversion of measurements. Results show that information gathered from both measurements enriches the reconstructed profile, leading to a more reliable estimation of saturation profiles. We believe that the joint inversion method herein developed could lead to the study of more complex phenomena, such as the coupled water-chloride ingress.

36 MATERIALS SCIENCE↗

Spectral induced polarization (SIP) measurements across a PFAS-contaminated source zone

There is a pressing need for the development of field-scale, in situ screening technologies for assessing variations in aqueous film forming foam (AFFF) concentrations in soils at former fire training and storage sites. Field-scale Spectral Induced Polarization (SIP) geophysical measurements were acquired on a transect crossing an AFFF source zone. Soil samples were acquired from ten locations and used to determine variations in poly- and per-fluoroalkyl substances (PFAS) concentrations in soils and soil texture. These samples were also used to create triplicate soil columns for laboratory-grade SIP measurements. Field and laboratory observations provide evidence that SIP measurements are sensitive to the concentration of AFFF constituents associated with the pore surface in soils. The phase of the SIP measurements on the laboratory samples was linearly correlated with total soil-sorbed PFAS concentration. The phase from the field SIP measurements was highest over the location of maximum PFAS concentration measured on the laboratory samples, although a significant correlation between field-measured phase and laboratory-measured total PFAS concentration was not established. The sensitivity of the SIP response to the removal of soil PFAS using a methanol wash procedure (total PFAS concentration drop of 366 ppb) adds evidence for the case for SIP characterization of AFFF source zones. The results of these studies suggest that SIP might be developed into a field-scale technology for rapid, indirect assessment of AFFF source zones. Such a technology could improve the effectiveness of AFFF source zone characterization at reduced costs.

58 GEOSCIENCES↗

X-ray continuum spectroscopy of inertial confinement fusion implosions at the National Ignition Facility

A methodology for measuring x-ray continuum spectra of inertial confinement fusion (ICF) implosions is described. The method relies on the use of ConSpec, a high-throughput spectrometer using a highly annealed pyrolytic graphite crystal , which measures the spectra in the ≃20–30 keV range. Due to its conical shape, the crystal is sagittally focusing a Bragg-reflected x-ray spectrum into a line, which enhances the recorded x-ray emission signal above the high neutron-induced background accompanying ICF implosions at the National Ignition Facility. To improve the overall measurement accuracy, the sensitivity of the spectrometer measured in an off-line x-ray laboratory setting was revised. The error analysis was expanded to include the accuracy of the off-line measurements, the effect of the neutron-induced background, as well as the influence of possible errors in alignment of the instrument to the ICF target. Here we demonstrate how the improved methodology is applied in the analysis of ConSpec data with examples of a relatively low-neutron-yield implosion using a tritium–hydrogen–deuterium mix as a fuel and a high-yield deuterium–tritium (DT) implosion producing high level of the background. In both cases, the shape of the measured spectrum agrees with the exponentially decaying spectral shape of bremsstrahlung emission to within ±10%. In the case of the high-yield DT experiment, non-monotonic deviations slightly exceeding the measurement uncertainties are observed and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IMPACT OF MEDIUM TEMPERATURE HEAT TREATMENT ON FLUX TRAPPING SENSITIVITY IN SRF CAVITIES

The effect of mid-T heat treatment on flux trapping sensitivity was measured on several 1.3 GHz single cell cavities subjected to medium temperature vacuum annealing at temperature of 150 - 400 ?C for a duration of 3 hours. The cavity was cooldown with residual magnetic field ?0 and ?20 mG in Dewar with cooldown condition of full flux trapped. The quality factor as a function of accelerating gradient was measured. The results show the correlation between the treatment temperature, quality factor, and sensitivity to flux trapping. Sensitivity increases with increasing heat treatment temperatures within the range of (200 - 325 ?C/3h).Moreover, variations in the effective penetration depth ofthe magnetic field and the density of quasi-particles can occur,influencing alterations in the cavity?s electromagneticresponse and resonance frequency.

Dhakal, P.↗

Acoustic Tomography of the Atmosphere: A Large-Eddy Simulation Sensitivity Study

Accurate measurement of atmospheric turbulent fluctuations is critical for understanding environmental dynamics and improving models in applications such as wind energy. Advanced remote sensing technologies are essential for capturing instantaneous velocity and temperature fluctuations. Acoustic tomography (AT) offers a promising approach that utilizes sound travel times between an array of transducers to reconstruct turbulence fields. This study presents a systematic evaluation of the time-dependent stochastic inversion (TDSI) algorithm for AT using synthetic travel-time measurements derived from large-eddy simulation (LES) fields under both neutral and convective atmospheric boundary-layer conditions. Unlike prior work that relied on field observations or idealized fields, the LES framework provides a ground-truth atmospheric state, enabling quantitative assessment of TDSI retrieval reliability, sensitivity to travel-time measurement noise, and dependence on covariance model parameters and temporal data integration. A detailed sensitivity analysis was conducted to determine the best-fit model parameters, identify the tolerance thresholds for parameter mismatch, and establish a maximum spatial resolution. The TDSI algorithm successfully reconstructed large-scale velocity and temperature fluctuations with root mean square errors ( RMSE s) below 0.35 m/s and 0.12 K, respectively. Spectral analysis established a maximum spatial resolution of approximately 1.4 m, and reconstructions remained robust for travel-time measurement uncertainties up to 0.002 s. These findings provide critical insights into the operational limits of TDSI and inform future applications of AT for atmospheric turbulence characterization and system design.

17 WIND ENERGY↗

Evaluation of ITER divertor shunts as a synthetic diagnostic for detachment control

Reliable diagnostics that measure the detached state of the ITER divertor plasma will be necessary to control heat flux to the divertor targets during steady state, burning plasma operation. This paper conducts an initial exploration into the feasibility of the divertor shunt diagnostic as a lightweight, robust, and real-time detachment sensor. This diagnostic is a set of shunt lead pairs that measure the voltage drop along the divertor cassette body, from which the plasma scrape-off layer (SOL) current is calculated. Using SOLPS-ITER simulations for control-relevant ITER plasma scenarios, the thermoelectric current magnitude along the SOL is shown to decrease significantly with the onset of partial detachment at the outer divertor target. Electromagnetic modelling of a simplified divertor cassette is used to develop a control-oriented inductance-resistance circuit model, from which SOL currents can be calculated from shunt pair voltage measurements. The sensitivity and frequency-response of the resulting system indicates that the diagnostic will accurately measure SOL thermoelectric currents during ITER operation. These currents will be a good measure of the detached state of the divertor plasma, making the divertor shunt diagnostic a potentially extremely valuable and physically robust sensor for real-time detachment control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward $\nu_{\mu}$CC $\eta$ Meson Cross Sections on Argon in SBND

The modeling of resonant neutrino interactions on argon is critical for achieving precision neutrino oscillation measurements and searching for physics beyond the Standard Model with both DUNE and the Short-Baseline Neutrino Program. Higher mass resonances beyond the $\Delta$(1232) baryon are particularly poorly constrained experimentally, and yet contribute a significant rate in multi-GeV interactions. The measurement of $\eta$(548) meson production from the decay of these resonances provides a unique probe, as well as the opportunity to measure observables sensitive to final state interactions with the nucleus. This poster will present progress towards the measurement of meson production with the Short-Baseline Near Detector (SBND) at Fermilab, leveraging the clean $\eta \rightarrow \gamma \gamma$ decay channel. The large statistics of the SBND dataset will provide high-precision measurements of this channel capable of constraining uncertainties in the modeling of higher order resonant interactions. This analysis further provides important handles on electromagnetic shower reconstruction performance through evaluation of the 548 MeV $\eta$ invariant mass peak.

Antonakis, Alexander [UC, Santa Barbara]↗

Testing lepton flavor universality at future Z factories

As one of the hypothetical principles in the Standard Model (SM), lepton flavor universality (LFU) should be tested with a precision as high as possible such that the physics violating this principle can be fully examined. The run of a Z factory at a future e + e − collider, such as the Circular Electron-Positron Collider or Future Circular Collider (electron/positron), provides a great opportunity to perform this task because of the large statistics and high reconstruction efficiencies for b hadrons at the Z pole. In this paper, we present a systematic study on the LFU test in future Z factories. The goal is threefold. First, we study the sensitivities of measuring the LFU-violating observables of b → c τ ν , i.e., R J / ψ , R D s , R D s * , and R Λ c , where τ decays muonically. For this purpose, we develop the strategies for event reconstruction, based on the track information significantly. Second, we explore the sensitivity robustness against detector performance and its potential improvement with the message of event shape or beyond the b -hadron decays. A picture is drawn on the variation of analysis sensitivities with the detector tracking resolution and soft photon detectability, and the impact of Fox-Wolfram moments is studied on the measurement of relevant flavor events. Finally, we interpret the projected sensitivities in the SM effective field theory, by combining the LFU tests of b → c τ ν and the measurements of b → s τ + τ − and b → s ν ¯ ν . We show that the limits on the LFU-violating energy scale can be pushed up to ∼ O ( 10 ) TeV for ≲ O ( 1 ) Wilson coefficients at Tera- Z . Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Performance testing of a Compton suppressed coincidence measurements using the Advanced Radionuclide Gamma-spectrOmeter

A Compton-suppressed multidimensional gamma-spectrometer is being developed within the Shallow Underground Laboratory (SUL) at Pacific Northwest National Laboratory (PNNL, USA). This Advanced Radionuclide Gamma-spectrOmeter (ARGO) system consists of two Broad Energy Germanium (BEGe) detectors, surrounded by a 12-detector sodium iodide (NaI) Compton suppression shield, situated inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, coincidence mode and Compton suppressed coincidence mode. Validation experiments measuring a neutron irradiated natural uranium sample, have demonstrated order of magnitude improvements in gamma detection sensitivity compared to conventional gamma-spectrometry techniques. Importantly this research demonstrates the feasibility of processing and analysing high-multiplicity datasets and the potential for high-sensitivity radionuclide measurements.

ARGO↗

Sensing depths in frequency domain thermoreflectance

In this work, a method is developed to calculate the length into a sample to which a Frequency Domain Thermoreflectance (FDTR) measurement is sensitive. Sensing depth and sensing radius are defined as limiting cases for the spherically spreading FDTR measurement. A finite element model for FDTR measurements is developed in COMSOL multiphysics and used to calculate sensing depth and sensing radius for silicon and silicon dioxide samples for a variety of frequencies and laser spot sizes. The model is compared to experimental FDTR measurements. Design recommendations for sample thickness are made for experiments where semi-infinite sample depth is desirable. For measurements using a metal transducer layer, the recommended sample thickness is three thermal penetration depths, as calculated from the lowest measurement frequency.

36 MATERIALS SCIENCE↗

Performance Demonstration of Self-Powered Neutron Detectors for Steady-State Reactor Operations

The irradiation testing of sensors in reactors is a crucial step towards calibrating and qualifying sensors prior to their deployment in experiments. This report details the process toward qualifying and calibrating custom-designed rhodium-based self-power neutron detectors (Rh-SPNDs) for steady-state reactor irradiations. This process serves to both demonstrate the performance capabilities of Rh-SPNDs as well as to provide experimental data for development of a sensor sensitivity model. Two designs of Rh-SPNDs were tested in various reactors to demonstrate: detection resolution in a low neutron flux environment, a delayed-response compensation technique, output linearity in a large range of neutron flux, and measurement accuracy verified with dosimetry. The detection resolution and compensation technique was demonstrated in the AGN-201m reactor at Idaho State University. The irradiation confirmed the sensors’ capability to perform steady-state operations in a low neutron flux of ~2E8 n/cm 2 -sec. Sensor output linearity coupled with the delayed-response compensation was investigated at the neutron radiography reactor at Idaho National Laboratory. A Rh-SPND was irradiated to neutron fluxes ranging from 2E8 to 2E13 n/cm2-sec range. The measured data demonstrated a wide and linear range of operation with a measured linear sensitivity of 1.0129 ×10 -13 A/W with a correlation-squared value of r 2 =0.9927. The measurement accuracy was investigated at the Advanced Test Reactor Critical reactor. The SPNDs were inserted into a test vehicle with collocated flux wires. Two irradiations with different flux levels were performed, and the SPNDs relative measurement between the two irradiations was calculated to be 1.2613 ± 0.0153 for the small SPND design and 1.1809 ± 0.0108 for the large SPND design. Both SPND measurements fell between the co-axial dosimetry result, which reported 1.218 ± 0.047. Additionally, the preliminary MCNP model for calculating SPND sensitivity was developed in parallel to this work. Modeled neutron spectrum with measured magnitude was used for inputs to determine the simulated SPND output. The results showed an overestimation of signal strength by a factor of 5, which was expected because of model simplification. This leads to future modeling work to account for signal losses from additional physical properties, including high temperature environments for FY-21.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Lineshapes of Temperature-Dependent Transport Measurements of Superconductors Under Pressure

Recent reports of superconductivity in the vicinity of room temperature have been the subject of discussion by the community. Specifically, features in the resistance-temperature (R-T) relations have raised questions. We show that many of these features can arise from previously unaccounted-for dynamic effects associated with the AC transport techniques often used in high- pressure experiments. These dynamic AC effects can cause the apparent resistance (R apparent ) to diverge from the DC resistance (R DC ), sharpen measured superconducting transitions, and produce other features in the measured R-T response. Here, we also show that utilizing the full output of phase-sensitive transport measurements provides a valuable probe of superconducting samples in difficult-to-measure systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of AmLi Sources for Active Well Coincidence Counter

To support the use of the Oak Ridge National Laboratory (ORNL) large-volume active well coincidence counter (LV-AWCC) in material control and accountancy (MC&A) measurements, a set of AmLi neutron sources was acquired from Savannah River National Laboratory (SRNL). These sources were measured to verify their suitability for use in the ORNL LV-AWCC. The sources produce neutrons at a rate that is within 4% of the rate for one set of AmLi sources already in use and 40% higher than the rate for the other set. These measurements indicate that the SRNL sources are suitable for use in the LV-AWCC because their sensitivity and measurement precision will be similar to those of the sets already in use. However, the SRNL sources still need to be evaluated for MC&A use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Methodology and in-situ validation

No reliable in-situ optical characterization tool is available that can efficiently and accurately measure various optical errors of individual heliostats in a utility-scale power-tower plant. Here, an innovative non-intrusive optical (NIO) approach is proposed to measure mirror surface slope error, mirror facet canting error, and heliostat tracking error based on reflection images using the natural target—the tower—in a heliostat field. The NIO approach adopts various techniques in photogrammetry, reflectometry, and geometrical optics to first determine the camera position and the actual tower position with respect to the heliostat. Then, Snell’s law is applied to find the surface normal at the reflection point or line of a reflection image and derive the surface slope error, mirror facet canting error, and heliostat tracking error accordingly. In addition, an in-situ validation is performed to demonstrate the feasibility of the NIO approach. Analysis with multiple sets of reflection images on one single heliostat of interest demonstrates that the NIO method can achieve a measurement uncertainty of 0.22 mrad for mirror facet slope error (root-mean-square) at the given test conditions. The sensitivity of measurement uncertainty to various parameters will be presented in a separate work. In the future, state-of-the-art unmanned aerial systems (UAS) are planned to perform the efficient image collection with a goal to complete the survey across a utility-scale field of over 10,000 heliostats within one or a few days depending on the number of UASs. The development of the NIO approach is expected to fill the critical gap for successful solar-field operation and maintenance, which is necessary for the global growth of the solar power-tower technology. The NIO approach can also be applied to any relevant industry requiring high-precision mirror surface shape characterization.

14 SOLAR ENERGY↗