Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Meteorological Measurement System on the NASA ER-2 aircraft

A Meteorological Measurement System (MMS) was designed and installed on one of the NASA high-altitude ER-2 aircraft (NASA 706). The MMS provides in situ measurements of free-stream pressure (+ or - 0.3 mb), temperature (+ or - 0.3 C), and wind vector (+ or - 1 m/s). It incorporates a high-resolution inertial navigation system specially configured for scientific applications, a radome differential pressure system for measurements of the airflow angles, and a compact, computer-controlled data acquisition system to sample, process and store 45 variables on tape and on disk. The MMS hardware and software development is described, and resolution and accuracy of the instrumentation discussed. Custom software facilitates preflight system checkout, inflight data acquisition, and fast postflight data download. It accommodates various modes of MMS data: analog and digital, serial and parallel, and synchronous and asynchronous. Flight results are presented to demonstrate the capability of the system.

Scott, Stan G.↗

Non-linearity in measurement systems: Evaluation method and application to microwave radiometers

A simple method for determination and correction of nonlinaearity in measurement systems is presented. The technique is applicable to a wide range of measuring systems. The basic concept, an analysis, and a sample application are given. Nonlinearity of the Goldstone DSS 13 low noise HEMT 2.3 GHz (S-band) radiometer system results in noise temperature measurement errors. These errors are successfully correct with this method.

Stelzried, C. T.↗

Study of a close-grid geodynamic measurement system

The Clogeos (Close-Grid Geodynamic Measurement System) concept, a complete range or range-rate measurement terminal installed in a satellite in a near-polar orbit with a network of relatively simple transponders or retro-reflectors on the ground at intervals of 0.1 to 10 km was reviewed. The distortion of the grid was measured in three dimensions to accuracies of + or - 1 cm with important applications to geodynamics, glaciology, and geodesy. User requirements are considered, and a typical grid, designed for earthquake prediction, was laid out along the San Andreas, Hayward, and Calaceras faults in southern California. The sensitivity of both range and range-rate measurements to small grid motions was determined by a simplified model. Variables in the model are satellite altitude and elevation angle plus grid displacements in latitude, and height.

Source record↗

A modular, programmable measurement system for physiological and spaceflight applications

The NASA-Ames Sensors 2000! Program has developed a small, compact, modular, programmable, sensor signal conditioning and measurement system, initially targeted for Life Sciences Spaceflight Programs. The system consists of a twelve-slot, multi-layer, distributed function backplane, a digital microcontroller/memory subsystem, conditioned and isolated power supplies, and six application-specific, physiological signal conditioners. Each signal condition is capable of being programmed for gains, offsets, calibration and operate modes, and, in some cases, selectable outputs and functional modes. Presently, the system has the capability for measuring ECG, EMG, EEG, Temperature, Respiration, Pressure, Force, and Acceleration parameters, in physiological ranges. The measurement system makes heavy use of surface-mount packaging technology, resulting in plug in modules sized 125x55 mm. The complete 12-slot system is contained within a volume of 220x150x70mm. The system's capabilities extend well beyond the specific objectives of NASA programs. Indeed, the potential commercial uses of the technology are virtually limitless. In addition to applications in medical and biomedical sensing, the system might also be used in process control situations, in clinical or research environments, in general instrumentation systems, factory processing, or any other applications where high quality measurements are required.

Hines, John W.↗

The preliminary checkout, evaluation and calibration of a 3-component force measurement system for calibrating propulsion simulators for wind tunnel models

The propulsion simulator calibration laboratory (PSCL) in which calibrations can be performed to determine the gross thrust and airflow of propulsion simulators installed in wind tunnel models is described. The preliminary checkout, evaluation and calibration of the PSCL's 3 component force measurement system is reported. Methods and equipment were developed for the alignment and calibration of the force measurement system. The initial alignment of the system demonstrated the need for more efficient means of aligning system's components. The use of precision alignment jigs increases both the speed and accuracy with which the system is aligned. The calibration of the force measurement system shows that the methods and equipment for this procedure can be successful.

Scott, W. A.↗

Development of a temperature measurement system with application to a jet in a cross flow experiment

A temperature measurement system, which allows the simultaneous sampling of up to 80 separate thermocouples, was developed. The minimum resolution for the system corresponds to + or - 0.16 C per least significant bit of the A/D converter. The time constant values lambda, for each of the 64 thermocouples, were determined experimentally at 7 mps. Software routines were used to correct the measured temperatures for the effect of lambda for each thermocouple. The temperature measurement system was utilized to study the thermal field of a heated jet discharging perpendicularly into a low and a high disturbance level cross stream for a given momentum flux ratio and for three overheated values. The peak instantaneous temperatures reveal that strong molecular diffusion was operative. Various measures of the thermal field, for the disturbed case, suggest that the jet column remains relatively compact while being buffeted by the ambient turbulence field and that its penetration, into the cross wind, is inhibited by the presence of the strong disturbance field.

Wark, C.↗

An in-place recalibration technique to extend the temperature capability of capacitance-sensing, rotor-blade-tip-clearance measurement systems

It is known that capacitance-sensing, rotor-blade-tip-clearance measurement systems suffer from a strong dependency on probe tip temperature and humidity. A novel in-place recalibration technique partly overcomes this problem through a simple modification of the electronics that permits a scale factor correction. The technique is used to reduce the errors in a commercial system by more than 50 percent up to a temperature of 370 C (700 F). A probe design is proposed to further raise the maximum temperature capability of the measurement system.

Barranger, J.↗

Comparisons of the NASA ER-2 meteorological measurement system with radar tracking and radiosonde data

Measurements of aircraft longitude, latitude, and velocity, and measurements of atmospheric pressure, temperature, and horizontal wind from the meteorological measurement system (MMS) on board the NASA ER-2 aircraft were compared with independent measurements of these quantities from radiosondes and radar tracking of both the ER-2 and radiosonde balloons. In general, the comparisons were good and within the expected measurement accuracy and natural variability of the meteorological parameters. Radar tracking of the ER-2 resolved the velocity and position drift of the inertial navigation system (INS). The rms errors in the horizontal velocity components of the ER-2, due to INS errors, were found to be 0.5 m/s. The magnitude of the drift in longitude and latitude depends on the sign and magnitude of the corresponding component velocity drift and can be a few hundredths of a degree. The radar altitudes of the ER-2 and radiosondes were used as the basis for comparing measurements of atmospheric pressure, temperature, and horizontal wind from these two platforms. The uncertainty in the MMS horizontal wind measurement is estimated to be +/- 2.5 m/s. The accuracy of the MMS pressure and temperature measurements were inferred to be +/- 0.3 hPa and +/- 0.3 K.

Gaines, Steven E.↗

Direct strike lightning measurement system

A research data system developed for in-flight measurement of direct and nearby lightning-strike characteristics is described. The measurement system consists of a wide-band analog recorder which records the continuous lightning scenario and fast sample-rate digital transient recorders with augmented memory capacity for increased time resolution of specific times of interest. Electromagnetic sensors with bandwidths exceeding 100 MHz are used which respond to rates of change of the quantities being measured. Data system immunity from electromagnetic interference is accomplished by the use of a dynamotor for power isolation, shielded system enclosure and fiber-optic data links.

Thomas, M. E.↗

A measurement system for large, complex software programs

This paper describes measurement systems required to forecast, measure, and control activities for large, complex software development and support programs. Initial software cost and quality analysis provides the foundation for meaningful management decisions as a project evolves. In modeling the cost and quality of software systems, the relationship between the functionality, quality, cost, and schedule of the product must be considered. This explicit relationship is dictated by the criticality of the software being developed. This balance between cost and quality is a viable software engineering trade-off throughout the life cycle. Therefore, the ability to accurately estimate the cost and quality of software systems is essential to providing reliable software on time and within budget. Software cost models relate the product error rate to the percent of the project labor that is required for independent verification and validation. The criticality of the software determines which cost model is used to estimate the labor required to develop the software. Software quality models yield an expected error discovery rate based on the software size, criticality, software development environment, and the level of competence of the project and developers with respect to the processes being employed.

Rone, Kyle Y.↗

Optical strain measurement system development, phase 1

A laser speckle, differential strain measurement system was built and tested for future applications in hostile environments. One dimensional electronic correlation of speckle pattern movement allows a quasi-real time measure of strain. The system was used successfully to measure uniaxial strain reaching into plastic deformation of a test specimen, at temperatures ranging to 450 C. A resolution of 16 microstrain is given by the photodiode array sensor pitch and the specimen to sensor separation. The strain measurement limit of the gauge is determined by air density perturbations causing decorrelation of the reference and shifted speckle patterns, and may be improved by limiting convective flow in the immediate vicinity of the test specimen.

Lant, Christian T.↗

A study of the geographic coverage properties of a satellite borne Doppler lidar wind velocity measuring system

Geographic coverage frequency and geographic shot density for a satellite borne Doppler lidar wind velocity measuring system are measured. The equations of motion of the light path on the ground were derived and a computer program devised to compute shot density and coverage frequency by latitude-longitude sections. The equations for the coverage boundaries were derived and a computer program developed to plot these boundaries, thus making it possible, after an application of a map coloring algorithm, to actually see the areas of multiple coverage. A theoretical cross-swath shot density function that gives close approximations in certain cases was also derived. This information should aid in the design of an efficient data-processing system for the Doppler lidar.

Pate, T. H.↗

Automation, Operation, and Data Analysis in the Cryogenic, High Accuracy, Refraction Measuring System (CHARMS)

The Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA s Goddard Space Flight Center has been enhanced in a number of ways in the last year to allow the system to accurately collect refracted beam deviation readings automatically over a range of temperatures from 15 K to well beyond room temperature with high sampling density in both wavelength and temperature. The engineering details which make this possible are presented. The methods by which the most accurate angular measurements are made and the corresponding data reduction methods used to reduce thousands of observed angles to a handful of refractive index values are also discussed.

Frey, Bradley↗

Automation, Operation, and Data Analysis in the Cryogenic, High Accuracy, Refraction Measuring System (CHARMS)

The Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center has been enhanced in a number of ways in the last year to allow the system to accurately collect refracted beam deviation readings automatically over a range of temperatures from 15 K to well beyond room temperature with high sampling density in both wavelength and temperature. The engineering details which make this possible are presented. The methods by which the most accurate angular measurements are made and the corresponding data reduction methods used to reduce thousands of observed angles to a handful of refractive index values are also discussed.

Frey, Bradley J.↗

The measurement system of pulse modulated carrier frequency stability and timing jitter

The definition of pulse modulated carrier frequency stability and timing jitter as well as the configuration and synchronous acquisition measurement method of its measurement system. Frequency stability of the pulse modulated carrier is measured with a discrimination technique. The pulse modulated carrier under testing is mixed with a reference frequency synthesizer. A delay line is used to convert the frequency fluctuation mixed IF signal to the voltage fluctuation. The system has the capability to make the phase noise measurement of two port devices on a pulsed carrier using a phase bridge. The noise voltage mentioned above is applied to the data acquisition and processing unit by PC to realize stability measurement. The data acquisition is in the form of pulse synchronization so that the measurement system accuracy is increased. The pulse width is more than 0.3 microseconds. The phase fluctuation variance, sigma, is less than 0.017. The time interval measuring system with high resolution is used to make interpulse timing and pulse width jitters automatic measurement. The pulse width is less than 0.2 ns. The resolution is 0.1 ns. The system is successfully applied to radar measurement.

Li Cheng-Fu↗