Search NASASearch

SEARCH · Search NASA

Results for “membrane electrode assemblies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

149 records · Page 8

Design, Build, and Testing of the Roman Space Telescope’s Wide Field Instrument Optical Stimulus System (SORC)

The Stimulus Of Ray Cones (SORC) is an optical stimulus system developed to verify, characterize, and calibrate the Roman Space Telescope’s (RST) Wide Field Instrument (WFI) under simulated operational conditions. SORC provides several critical test modes, the primary being point-source mode, which projects an image anywhere on the Focal Plane Assembly (FPA) detectors. This mode provides precise position knowledge of the FPA within WFI. Additional modes enable capturing WFI pupil alignment, evaluation of WFI’s selectable optical elements, and verification of focal plane fiber operation for higher-level system testing. The light source system incorporates a suite of narrowband and broadband fiber fed sources spanning the visible to near-infrared range, with options for pulsed or continuous wave illumination. SORC was designed and built at NASA’s Goddard Spaceflight Center (GSFC). Initial system-level testing occurred under ambient conditions in GSFC’s Spacecraft Systems Development and Integration Facility (SSDIF), followed by vacuum testing at operational temperatures (SORC at 214-222 K) in the Space Environment Simulator (SES). The system was then shipped to BAE Systems in Boulder, CO for post-shipment ambient and cryogenic testing before integration with WFI for two thermal vacuum test campaigns at cryogenic temperatures. This presentation will focus on design, development, and performance of SORC. Details of WFI verification and calibration using SORC, along with test results, have been published previously and will be referenced only as needed to describe SORC. The SORC ground test capability is critical to ensuring WFI meets stringent optical performance requirements, directly supporting the mission’s science objectives.

Stimulus of Ray Cones

Characterization testing of a 40 Ahr bipolar nickel hydrogen battery

In a continuing effort to develop NiH2 bipolar technology to a point where it can be used efficiently in space flight, testing of a second 40 Ahr, 10-cell bipolar battery has begun. This battery has undergone extensive characterization testing to determine the effects of such operating parameters as charge and discharge rates, temperature, and pressure. The fundamental design of this actively cooled bipolar battery is the same as the first battery. Most of the individual components, however, are from different manufacturers. Different testing procedures as well as certain unique battery characteristics make it difficult to directly compare the two sets of results. In general, the performance of this battery throughout characterization produced expected results. The main differences seen between the first and second batteries occurred during the high-rate discharge portion of the test matrix. The first battery also had poor high-rate discharge results, although better than those of the second battery. Minor changes were made to the battery frame design used for the first battery in an attempt to allow better gas access to the reaction sites for the second build and hopefully improve performance. The changes, however, did not improve the performance of the second battery and could have possibly contributed to the poorer performance that was observed. There are other component differences that could have contributed to the poorer performance of the second battery. The H2 electrode in the second battery was constructed with a Goretex backing which could have limited the high-rate current flow. The gas screen in the second battery had a larger mesh which again could have limited the high-rate current flow. Small scale 2 x 2 batteries are being tested to evaluate the effects of the component variations.

Brewer, Jeffrey C.

Review of European Microgravity Measurements

AA In a French/Russion cooperation, CNES developed a microgravity detection system for analyzing the Mir space station micro-g-environment for the first time. European efforts to characterize the microgravity (1/9) environment within a space laboratory began in the late seventies with the design of the First Spacelab Mission SL-1. Its Material Science Double Rack was the first payload element to carry its own tri-axial acceleration package. Even though incapable for any frequency analysis, the data provided a wealth of novel information for optimal experiment and hardware design and operations for missions to come. Theoretical investigations under ESA contract demonstrated the significance of the detailed knowledge of micro-g data for a thorough experiment analysis. They especially revealed the high sensitivity of numerous phenomena to low frequency acceleration. Accordingly, the payloads of the Spacelab missions D-1 and D-2 were furnished with state-of-the-art detection systems to ensure frequency analysis between 0.1 and 100 Hz. The Microgravity Measurement Assembly (MMA) of D-2 was a centralized system comprising fixed installed as well as mobile tri-axial packages showing real-time data processing and transmission to ground. ESA's free flyer EURECA carried a system for continuous measurement over the entire mission. All EURECA subsystems and experimental facilities had to meet tough requirements defining the upper acceleration limits. In a French/Russion cooperation, CNES developed a mi crogravity detection system for analyzing the Mir space station micro-g-environment for the first time. An approach to get access to low frequency acceleration between 0 and 0.02 Hz will be realized by QSAM (Quasi-steady Acceleration Measurement) on IML-2, complementary to the NASA system Spacelab Acceleration Measurement System SAMS. A second flight of QSAM is planned for the Russian free flyer FOTON.

H Hamacher

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

A review of nickel hydrogen battery technology

This paper on nickel hydrogen batteries is an overview of the various nickel hydrogen battery design options, technical accomplishments, validation test results and trends. There is more than one nickel hydrogen battery design, each having its advantage for specific applications. The major battery designs are individual pressure vessel (IPV), common pressure vessel (CPV), bipolar and low pressure metal hydride. State-of-the-art (SOA) nickel hydrogen batteries are replacing nickel cadmium batteries in almost all geosynchronous orbit (GEO) applications requiring power above 1 kW. However, for the more severe low earth orbit (LEO) applications (greater than 30,000 cycles), the current cycle life of 4000 to 10,000 cycles at 60 percent DOD should be improved. A NASA Lewis Research Center innovative advanced design IPV nickel hydrogen cell led to a breakthrough in cycle life enabling LEO applications at deep depths of discharge (DOD). A trend for some future satellites is to increase the power level to greater than 6 kW. Another trend is to decrease the power to less than 1 kW for small low cost satellites. Hence, the challenge is to reduce battery mass, volume and cost. A key is to develop a light weight nickel electrode and alternate battery designs. A common pressure vessel (CPV) nickel hydrogen battery is emerging as a viable alternative to the IPV design. It has the advantage of reduced mass, volume and manufacturing costs. A 10 Ah CPV battery has successfully provided power on the relatively short lived Clementine Spacecraft. A bipolar nickel hydrogen battery design has been demonstrated (15,000 LEO cycles, 40 percent DOD). The advantage is also a significant reduction in volume, a modest reduction in mass, and like most bipolar designs, features a high pulse power capability. A low pressure aerospace nickel metal hydride battery cell has been developed and is on the market. It is a prismatic design which has the advantage of a significant reduction in volume and a reduction in manufacturing cost.

Smithrick, John J.

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

The Growth of Zeolites A, X and Mordenite in Space

Zeolites are a class of crystalline aluminosilicate materials that form the backbone of the chemical process industry worldwide. They are used primarily as adsorbents and catalysts and support to a significant extent the positive balance of trade realized by the chemical industry in the United States (around $19 billion in 1991). The magnitude of their efforts can be appreciated when one realizes that since their introduction as 'cracking catalysts' in the early 1960's, they have saved the equivalent of 60 percent of the total oil production from Alaska's North Slope. Thus the performance of zeolite catalysts can have a profound effect on the U.S. economy. It is estimated that a 1 percent increase in yield of the gasoline fraction per barrel of oil would represent a savings of 22 million barrels of crude oil per year, representing a reduction of $400 million in the United States' balance of payments. Thus any activity that results in improvement in zeolite catalyst performance is of significant scientific and industrial interest. In addition, due to their 'stability,' uniformity, and, within limits, their 'engineerable' structures, zeolites are being tested as potential adsorbents to purify gases and liquids at the parts-per-billion levels needed in today's electronic, biomedical, and biotechnology industries and for the environment. Other exotic applications, such as host materials for quantum-confined semiconductor atomic arrays, are also being investigated. Because of the importance of this class of material, extensive efforts have been made to characterize their structures and to understand their nucleation and growth mechanisms, so as to be able to custom-make zeolites for a desired application. To date, both the nucleation mechanics and chemistry (such as what are the 'key' nutrients) are, as yet, still unknown for many, if not all, systems. The problem is compounded because there is usually a 'gel' phase present that is assumed to control the degree of supersaturation, and this gel undergoes a continuous 'polymerization' type reaction during nucleation and growth. Generally, for structure characterization and diffusion studies, which are useful in evaluating zeolites for improving yield in petroleum refining as well as for many of the proposed new applications (e.g., catalytic membranes, molecular electronics, chemical sensors) large zeolites (greater than 100 to 1000 times normal size) with minimum lattice defects are desired. Presently, the lack of understanding of zeolite nucleation and growth precludes the custom design of zeolites for these or other uses. It was hypothesized that the microgravity levels achieved in an orbiting spacecraft could help to isolate the possible effects of natural convection (which affects defect formation) and minimize sedimentation, which occurs since zeolites are twice as dense as the solution from which they are formed. This was expected to promote larger crystals by allowing growing crystals a longer residence time in a high-concentration nutrient field. Thus it was hypothesized that the microgravity environment of Earth orbit would allow the growth of large, more defect-free zeolite crystals in high yield.

A Sacco, Jr

Bipolar Ag-Zn battery

The silver-zinc (AgZn) battery system has been unique in its ability to safely satisfy high power demand applications with low mass and volume. However, a new generation of defense, aerospace, and commercial applications will impose even higher power demands. These new power demands can be satisfied by the development of a bipolar battery design. In this configuration the power consuming, interelectrode current conductors are eliminated while the current is then conducted via the large cross-section electrode substrate. Negative and positive active materials are applied to opposite sides of a solid silver foil substrate. In addition to reducing the weight and volume required for a specified power level, the output voltage performance is also improved as follows. Reduced weight through: elimination of the plastic cell container; elimination of plate leads and intercell connector; and elimination of internal plate current collector. Increased voltage through: elimination of resistance of current collector; elimination of resistance of plate lead; and elimination of resistance of intercell connector. EPI worked previously on development of a secondary bipolar silver zinc battery. This development demonstrated the electrical capability of the system and manufacturing techniques. One difficulty with this development was mechanical problems with the seals. However, recent improvements in plastics and adhesives should eliminate the major problem of maintaining a seal around the periphery of the bipolar module. The seal problem is not as significant for a primary battery application or for a requirement for only a few discharge cycles. A second difficulty encountered was with activation (introducing electrolyte into the cell) and with venting gas from the cell without loss of electrolyte. During previous work, the following projections for energy density were made from test data for a high power system which demonstrated in excess of 50 discharge/charge cycles. Projected system power = 100 kilowatts; discharge time = 30 seconds; discharge current density = 1.75 amps/sq in.; system weight = 86 lbs (9.7 WH/lb); and system volume = 1071 cu. in. (.78 WH/cu. in.). EPI is currently working on a development program to produce a bipolar silver-zinc battery design for NASA. The potential application would be to power electromechanical actuators for space launch vehicles.

Giltner, L. John

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

ARCTRON: A Rapid Experimental Proving Ground for TPS Experiments and Arcjet Technology Development

Innovation in high-enthalpy facilities is fundamentally limited by the cost and risk of experimentation. New concepts for plasma control, diagnostics, facility components, and plasma-material interaction often require repeated iterations that are impractical to perform in production arcjets. As a result, promising ideas may remain unexplored or reach operational facilities only after significant development effort. ARCTRON is being developed as a rapid experimental proving ground where new ideas in plasma science, arcjet engineering, diagnostics, and material response can be conceived, tested, and quantitatively evaluated before transition to large-scale facilities. The platform combines radio-frequency (RF) and DC arc plasma generation, externally applied magnetic fields, configurable gas composition, reduced-pressure operation, laser heating, electrical biasing, and modular diagnostic access. These capabilities permit the plasma source, applied forcing, test article, and measurement configuration to be modified independently, allowing individual physical mechanisms to be isolated more readily than in a traditional test environment. One class of investigations addresses fundamental plasma-surface interaction physics. Conventional material tests often expose a specimen simultaneously to convective heating, reactive species, pressure, shear, radiation, and surface-current effects. The resulting material response may be measured accurately, while the contribution of each mechanism remains difficult to identify. ARCTRON is designed to vary these effects selectively. Plasma chemistry can be changed independently through configurable gas mixtures; magnetic fields and electrical biasing can modify charged-particle transport; laser heating can provide a non-plasma thermal input; and pressure, flow, and discharge mode can be varied over a broad operating space. This enables controlled tests of hypotheses involving surface catalycity, reactive-species transport, plasma-assisted oxidation, electromagnetic effects, shear, and the relative contributions of thermal and chemical loading. A second class of investigations enabled by this approach concerns the engineering of high-enthalpy facilities themselves. Arc-heated facilities are limited by electrode erosion, unstable arc attachment, localized heating, and damage to nozzles and other plasma-facing components. ARCTRON provides a lower-cost environment for testing concepts intended to mitigate these limitations. Candidate investigations include the use of applied magnetic fields to alter current paths and reduce plasma interaction with nozzle walls, ExB forcing to introduce controlled plasma rotation, magnetic or geometric approaches for distributing arc attachment, and alternative electrode or discharge configurations intended to reduce erosion and improve stability. Because the platform is reconfigurable, these concepts can be evaluated through repeated design--build--test cycles before they are considered for implementation in operational facilities. The platform also supports the development and validation of diagnostics that may be difficult to introduce initially into a large arcjet. Current and planned measurements include spatially resolved optical emission spectroscopy, electrostatic probes, fast imaging, pyrometry, calorimetry, laser-induced fluorescence, and absorption spectroscopy. These diagnostics are intended not merely to document a nominal operating condition, but to constrain the local plasma state and its relationship to component or material response. The modular facility geometry allows diagnostic concepts to be tested, calibrated, and compared under repeatable conditions before deployment in more demanding environments. ARCTRON is also supported by an integrated software suite. Automated control and data acquisition allow discharge parameters, gas composition, magnetic fields, diagnostic timing, and test configuration to be recorded as part of each experiment (STARDAC - Software for Testing, Analysis, Research Data, and Control). The Backend for Experiment Analysis, Storage, and Traceability (BEAST) is a database that provides the infrastructure needed to associate heterogeneous measurements with facility configuration, specimen identity, calibration state, geometry, and analysis provenance. This backend is particularly important for exploratory campaigns, in which many related configurations may be tested, and the value of an individual experiment depends on its connection to earlier and subsequent iterations. Complementary analysis capabilities, including computer-vision-based transient response measurements (arcjetCV), three-dimensional surface reconstruction (STARSCAN), and model-based Bayesian inference (SHIELD), and tomography data analysis (TOMATO, PuMA) can be incorporated when required by a specific hypothesis without becoming the focus of every campaign. The central objective of ARCTRON is therefore not to maximize heat flux or reproduce a complete flight environment. Its purpose is to reduce the cost and time required to ask consequential questions about plasma behavior, plasma-facing materials, diagnostics, and arcjet technology. By providing a controlled environment for rapid reconfiguration, mechanism isolation, quantitative measurement, and iterative engineering, ARCTRON can help mature concepts that would otherwise remain too speculative or too risky for evaluation in production facilities. The resulting knowledge can then guide the design of material models, focus test objectives in larger arcjets, reduce facility-development risk, and improve the physical basis of high-enthalpy ground testing. This work will present the ARCTRON architecture, operating modes, diagnostic suite, and digital experimental workflow. Initial experimental results from the first integrated operation of the facility will be presented, including flow characterization, power limitations, and deployment of the initial diagnostic suite. Ongoing development efforts aimed at catalycity characterization, magnetic plasma control, and advanced optical diagnostics will also be discussed, illustrating how the platform supports rapid iteration from concept to experiment.

experimental diagnostics

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Thermal Interface Materials (TIMs) are critical components in spacecraft thermal management systems, where thermal performance is strongly influenced by vacuum conditions, interface contact resistance, and layered metallic joint behavior. However, manufacturer-reported thermal conductivity values are often derived under idealized conditions and may not accurately represent performance within operational aerospace applications. To address this limitation, the Testbed for Advanced Interface Materials in Vacuum (TAIMV) was developed as a modular vacuum-compatible thermal conductivity characterization platform capable of evaluating aerospace-relevant TIM configurations under both ambient and high-vacuum environments. The testbed was derived from the ASTM C1044-16 guarded hot plate methodology and incorporates interchangeable layers of stainless steel coupon geometries, independently controlled main and guard heaters, embedded resistance temperature detectors (RTDs), thermocouples, multi-layer insulation (MLI), and a temperature-controlled cold plate to characterize through-thickness thermal gradients across layered interfaces. In the current configuration, interface compression is limited to the nominal contact pressure generated by the experimental stack assembly. Initial experimental campaigns were conducted at ambient pressure and below 1×10-5 torr for vacuum cases using multiple interface materials including Braycote 601EF and Krytox-based greases across a range of thermal operating conditions. In parallel, a coupled numerical Python thermal model was developed to predict temperature distribution throughout the stack while accounting for conduction, radiation, and parasitic heat transfer pathways and effective interface resistance effects. Experimental measurements and numerical predictions showed consistent thermal trends across multiple operating conditions and environmental states. Results also revealed measurable differences between ambient and vacuum thermal behavior, demonstrating the importance of interface resistance, parasitic heat transfer mechanisms, and stack geometry in determining effective thermal performance within layered thermal interfaces. The presented work establishes a foundation for future thermal model correlation efforts and expanded characterization of aerospace thermal interface materials under representative environmental conditions. Future work will focus on the integration of a load cell system to enable controlled pressure-dependent characterization of thermal interface materials under compressive loading. This capability will allow investigation of the influence of contact pressure on effective thermal conductivity, interface resistance, and thermal performance within layered aerospace thermal interfaces under representative operational conditions.

Thermal Development Testing

Copper-Wire-Card Detectors

Card Design - Each copper-wire-card detector consisted of a winding of fine wire mounted to a 1.45- by 7 .00-inch rectangular card. Two wire sizes were used - 2-mil and 3-mil (fourteen 2-mil cards and thirty-two 3-mil cards). The total exposed effective area was about 1.2 square feet (0.11 square meters). A sketch of a detector is shown in figure X-1. These detectors are similar to the detectors flown on previous satellites. Quadrant Design - The 36 cards are arranged in four groups of 12 cards each with four pairs of 3-mil cards in parallel and four single 2-mil cards in parallel. Each group is mounted on a fiber-glass support that can readily be removed from the payload for repairs or replacements with appropriate spares. Individual cards can be replaced readily if necessary. The assembly of the quadrants is shown in figure II-2. Temperature-Balance Experiment - The grids for the temperature-balance experiment were wound with insulated wire. The thermal balance of such a winding has been examined under conditions approximating flight environment. One card of 3-mil wire with a thermistor attached was enclosed in a bell jar and exposed to the sun after evacuation. External radiation was reduced by shading the bell jar except for a window which allowed the sun's rays to strike the winding. The temperature of the thermistor was recorded at intervals. Figure X-2 shows that the temperature does not rise beyond 65° C in 20 minutes of continuous exposure to the sun. Complementary tests made by Dr. Roger E. Gaumer of Lockheed Aircraft Corp. give a ratio of absorptivity to emissivity of 1 for this type of enamel insulated wire. Compensation for Resistance Changes - Temperatures at the wire-card surfaces were expected to extend from -10° C to a maximum of 60° C. Since copper has a thermal coefficient of resistance of 0.33 percent per °C, the resistance of the wire would change 22 percent and a compensator had to be provided. A 100-ohm thermistor with a negative coefficient of -3-9 percent per °C was selected, wired in parallel with a 300-ohm fixed resistor and installed in series with each 2-mil card and with each pair of 3-mil cards. The effective resistance of 2-mil and 3-mil compensated cards is shown in figure X-3 for various temperatures and compared with the resistance of uncompensated copper. The increase in resistance from 20° C to 60° C is 12 ohms or 2.7 percent. Below 20° C the effective resistance also increases and the curve is similar to that obtained for high temperatures.

Detector

Enabling Mission Flexibility to Battery Driven Deep Space Endeavors With Generalized Battery-Health-Monitoring Using Physics-Based and Data-Driven Reduced-Order Models

The needs and requirements for an electrochemical energy storage for deep space exploration is well explored. It is often understood that different mission sites and environmental conditions require different battery chemistries or technologies. Additionally, various engineering solutions are deployed to overcome specific chemical challenges. One often overlooked need is the “health” monitoring of an electrochemical storage system. The term generalized health monitoring, as envisioned in this work, refers to the monitoring of various aspects such as electrode health, electrolyte health, reaction pathway health, cooling system health, sensor health, and BMS health [1]. Generalized health monitoring allows mission leads, engineers, and scientists to incorporate flexibility in mission designs, make on-the-fly mission changes, and extend the duration of science missions. Moreover, it enables automation and data-driven decision-making without compromising safety and performance. Recently, our group developed a hierarchy of thermal reduced-order models (TROM) by combining a physics-based modeling approach and data-driven model reduction techniques applied to flight data [2]. The resulting TROMs were found to be not only accurate but also identifiable from the flight data. Consequently, the coefficient of variance of the model parameters is small over the course of hundreds of flights, allowing for monitoring the parameter evolution trajectories as the battery ages and degrades. These parameters constitute the metrics of the generalized health of a battery. Monitoring their evolution allows such models to be used for anomaly detection and prognostics, improving early detection of abnormal behavior and thus enabling timely maintenance, longer battery life, and enhanced battery safety. For this presentation, the practicality of the thermal model will be validated on a pack of 14cells under various topology configurations such as 1S14P, 2P7S, 7S2P, and 1P14S. It is well known that manufacturing and non-uniform aging lead to variability in the performance of a cell, which is exacerbated by cell balancing during active load. Additionally, in extreme scenarios, the paramount objective is to complete the mission, regardless of the stresses on the battery. Topology-induced balancing issues further stress the battery. The goal of this study is to determine if the noise (identifiability) in the reduced-order thermal model parameters is sensitive to topology, cell spacing, cooling strategy, and manufacturing or age variability. The variability in cells is considered by assuming a multimodal distribution for microscopic parameters of a cell (such as porosity, tortuosity, reaction kinetics, volumetric thermal conductivity, and volumetric heat capacity). The compounded effect of manufacturing variability, topological selection, cooling strategies, and cell balancing ages each cell in a battery differently. The study aims to clarify whether the challenge in extracting maximum information depends on the minimum number of sensors or models used for data extraction.

Automation

Thermal Considerations for 2039 Opposition Class Nuclear Electric Propulsion/Chemical Propulsion Crewed Mars Mission

The high specific impulse (Isp) of Nuclear Electric Propulsion (NEP) technology offers the potential for advanced space mission capabilities. However, the five critical technology elements of NEP vehicles have yet to prove technical maturity levels for consideration into mission design. In response to the critical reviews by the NASA Engineering and Safety Center (NESC) and the National Academies of Sciences, Engineering, and Medicine (NASEM), NASA’s Space Nuclear Propulsion (SNP) project created an NEP Technology Maturation Plan (TMP) for focused development of NEP technology. The TMP called for a coordinated set of technology development efforts to meet this objective. The Modular Assembled Radiators for NEP VehicLes (MARVL) Early Career Initiative (ECI) project was initiated to develop a portion of the fifth Critical Technology Element (CTE) of the NEP vehicle: the Primary Heat Rejection Subsystem (PHRS). A target application of a 2039 human-rated Mars mission was outlined in the TMP. For the outlined mission, a NEP vehicle will experience several thermal environments which will impact the design and operation of the PHRS. To maintain radiator temperatures within the required effective temperature range, the effect of natural, induced, and NEP internally generated heat loads on the radiator panel must be well understood. Furthermore, this analysis is critical for analyzing the influence of various orientations and positions of the NEP vehicle relative to nearby celestial bodies throughout the mission. This study conducted a complete enveloping analysis of the thermal environments influencing the NEP vehicle throughout the mission. Thermal analysis was conducted for the radiator panels based on the defined mission environments. This thermal analysis concludes with the selection of ideal radiator orientations for the NEP vehicle, and the identification of worst case hot and cold environmental sink temperatures throughout the mission. For the target application, the environmental sink temperature while the reactor is powered OFF or powered ON ranges from 30 K to 353 K and 2.7 K to 243 K respectively. When considering interplanetary space, the minimum environmental sink temperature when the reactor is powered OFF and the radiators are oriented “edge to Sun” is 2.7 K. The environmental thermal models generated in this study will be used for future studies with the full vehicle system model. The environmental sink temperature curves generated will be used for future radiator and component analysis to predict transient performance in the space environment. The environmental sink temperature and heat rejection capability curves will inform the trade between commissioning orbits that are in consideration. The model may also serve as a useful tool as reference for future crewed space missions, missions involving radiators or temperature sensitive equipment, or other missions requiring analysis of natural orbital thermal environments.

Nuclear Electric Propulsion