Search NASA⌕ Search

SEARCH · Search NASA

Results for “meter, test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Accurate measurement of gas volumes by liquid displacement

Mariotte bottle as liquid displacement device was used to measure gas volumes at flow rates that are far below threshold of wet test gas meters. Study of factors affecting amount of liquid displaced by gas flow was completed, and equations were derived which relate different variables.

Christian, J. D.↗

A fluidic device for measuring constituent masses of a flowing binary gas mixture

A continuous reading mass flow device was developed to measure the component flow of a binary gas mixture. The basic components of the device are a fluidic humidity sensor and a specially designed flow calorimeter. These components provide readings of gas mixture ratio, mixture heat capacity, heat dissipated by the calorimeter and the gas temperature rise across the calorimeter. These parameter values, applied in the general definitions of specific heat capacity and the heat capacity of a gas mixture, produce calculated component flow rates of the mixture being metered. A test program was conducted to evaluate both the steady state and dynamic performance of the device.

Prokopius, P. R.↗

Low-speed aerodynamic characteristics of a hypersonic research airplane concept having a 70 deg swept delta wing

An experimental investigation of the low-speed static longitudinal, lateral and directional stability characteristics of a hypersonic research airplane concept having a 70 deg swept delta wing was conducted in a low-speed tunnel with a 12-foot (3.66 meter) octagonal test section. Aircraft component variations included: (1) fuselage shape modifications, (2) tip fins, (3) center vertical fin, (4) wing camber, and (5) wing planform. This investigation was conducted at a dynamic pressure of 262.4 Pa (5.48 psf), a Mach number of 0.06, and a Reynolds number of 2.24 million, based on body length. Tests were conducted through an angle-of-attack range of 0 deg to 30 deg with elevon deflections from +5.0 deg to minus 30.0 deg. The complete configuration exhibited positive static longitudinal, lateral and directional stability up to angles of attack of at least 20 deg and was trimmable to lift coefficients of at least 0.70 with elevon deflections of minus 30 deg.

Creel, T. R., Jr.↗

Low speed aerodynamic characteristics of a lifting-body hypersonic research aircraft configuration

An experimental investigation of the low-speed longitudinal, lateral, and directional stability characteristics of a lifting-body hypersonic research airplane concept was conducted in a low-speed tunnel with a 12-foot (3.66-meter) octagonal test section at the Langley Research Center. The model was tested with two sets of horizontal and vertical tip controls having different planform areas, a center vertical tail and two sets of canard controls having trapezoidal and delta planforms, and retracted and deployed engine modules and canopy. This investigation was conducted at a dynamic pressure of 239.4 Pa (5 psf) (Mach number of 0.06) and a Reynolds number of 2 million based on the fuselage length. The tests were conducted through an angle-of-attack range of 0 deg to 30 deg and through horizontal-tail deflections of 10 deg to minus 30 deg. The complete configuration exhibited excessive positive static longitudinal stability about the design center-of-gravity location. However, the configuration was unstable laterally at low angles of attack and unstable directionally throughout the angle-of-attack range. Longitudinal control was insufficient to trim at usable angles of attack. Experiments showed that a rearward shift of the center of gravity and the use of a center-located vertical tail would result in a stable and controllable vehicle.

Penland, J. A.↗

Onset of condensation effects with an NACA 0012-64 airfoil tested in the Langley 0.3-meter transonic cryogenic tunnel

The onset of condensation effects as determined by varying the stagnation temperature was found to correlate better with the amount of supercooling in the free stream than it did with the supercooling in the region of maximum local Mach number over the air foil. Effects in the pressure distribution over the air foil were seen to appear over its entire length at nearly the same total temperature. Both observations suggest that heterogeneous nucleation does occur in the free stream. The benefits realized from supercooling are presented in terms of increased Reynolds number capability at a given tunnel total pressure and reduced drive-fan power and liquid nitrogen consumption if Reynolds number is held constant. Depending on total pressure and free-stream Mach number, these three benefits are found to vary respectively from 8 to 19 percent, 12 to 24 percent, and 9 to 19 percent. The data analysis and error estimates are given.

Hall, R. M.↗

Current leakage for low altitude satellites

Ionospheric plasma densities exceeding 1,000,000 per cu cm exist around satellites in low earth orbit. Operation of large solar arrays at high voltage may drive substantial leakage currents through this surrounding plasma. Power losses exceeding solar cell output have been observed for small arrays biased above +2,000 V. Estimates of these effects for very large power systems are developed. Recent large scale (10 meter) lab tests are reported. Estimates based on calculations of space charge limited sheath dimensions are identified as a good working model, leading to projected power losses for large arrays increasing much more slowly than for small arrays.

Mccoy, J. E.↗

Four band differential radiometer for monitoring LNG vapors

The development by JPL of a four band differential radiometer (FBDR) which is capable of providing a fast rate of response, accurate measurements of methane, ethane, and propane concentrations on the periphery of a dispersing LNG cloud. The FBDR is a small, low power, lightweight, portable instrument system that uses differential absorption of near infrared radiation by the LNG cloud as a technique for the determination of concentration of the three gases as the LNG cloud passes the instrument position. Instrument design and data analysis approaches are described. The data obtained from the FBDR prototype instrument system deployed in an instrument array during two 40 cubic meter spill tests are discussed.

Simmonds, J. J.↗

Studies of condensation effects on airfoil testing in the Langley 0.3-meter transonic cryogenic tunnel

In the context of an overall development of transonic, cryogenic wnd tunnel technology, NASA has been investigating the onset of condensation effects in nitrogen gas. The temperature at which condensation occurs determines the minimum operating temperature (MOT) of cryogenic tunnels. The apparatus and airfoils are discussed, taking into account a description of the 0.3-m Transonic Cryogenic Tunnel (TCT), the drag rake, the airfoils, and the technique used for determining the onset of condensation effects. Attention is also given to the types of nucleation processes, the relative sensitivity of drag rake and surface pressure measurements, correlations between data and theory, the prediction of minimum operating temperatures for the 0.3-m TCT, and MOT's for different tunnels.

Hall, R. M.↗

A Deep Optical Survey of the Ecliptic

This was an observing-intensive investigation into the newly discovered regions of the solar system beyond Neptune. The research was focussed on the use of unique imaging facilities on telescopes atop Mauna Kea, Hawaii, although other observatories (in Arizona and Chile) were also occasionally used. We secured about 20 nights of telescope time per year for our 'Medium Depth Wide Area' survey (JLC96). In this, we covered 5 sq. deg. of sky to apparent red magnitude 24.2. We used a high quantum efficiency Tektronix 2048x2048 CCD for all observations in this program. We secured observing time at the UH 2.2 meter for testing the suitability of a much larger array CCD camera for survey work (an 8192x8192 pixel device). We obtained observing runs at the twin Schmidt telescopes of Kitt Peak National Observatory and Cerro-Tololo InterAmerican Observatory in order to assess the number of bright Kuiper Belt objects, Centaurs and gas giant Trojans.

Jewitt, David↗

Heatshield for Extreme Entry Environment Technology (HEEET) Thermal Protection System (TPS)

Starting in 2013 and completing in 2019, the Heatshield for Extreme Entry Environment Technology (HEEET) project has been working to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations with extreme entry environments such as Venus, Saturn, Uranus, Neptune and high-speed sample return missions to Earth. A key aspect of the project has been the building and testing of a 1-meter base diameter Engineering Test Unit (ETU) representative of what could be used for a Saturn probe. This paper provides a high-level overview of the HEEET project including manufacturing and testing of the ETU for structural model verification, establish system capability and verify manufacturing workmanship.

Extreme Entry Environment↗

Heatshield for Extreme Entry Environment Technology (HEEET) Thermal Protection System (TPS)

Over the last 5 years, the Heatshield for Extreme Entry Environment Technology (HEEET) project has been working to mature a 3-D Woven Thermal Protection System (TPS) to Technical Readiness Level (TRL) 6 to support future NASA missions to destinations with extreme entry environments such as Venus, Saturn, Uranus, Neptune and high speed sample return missions to Earth. A key aspect of the project has been the building and testing of a 1-meter base diameter Engineering Test Unit (ETU) representative of what could be used for a Saturn probe. This paper provides a high level overview of the HEEET project including manufacturing and testing of the ETU which has been subjected to mission relevant thermal and mechanical loads, to verify structural models, establish system capability and verify manufacturing workmanship.

TPS↗

Heat Transfer Experiments and Analysis of a Simulated HTS

Long-length high temperature superconducting (HTS) cable projects, over 1 km, are being designed that are cooled by flowing liquid nitrogen. The compact counter-flow cooling arrangement which has the supply and return stream in a single cryostat offers several advantages including smallest space requirement, least heat load, and reduced cost since a return cryostat is not required. One issue in long length HTS cable systems is the magnitude of the heat transfer radially through the cable. It is extremely difficult to instrument an HTS cable in service on the grid with the needed thermometry because of the issues associated with installing thermometers on high voltage components. A 5-meter long test system has been built that simulates a counter-flow cooled, HTS cable using a heated tube to simulate the cable. Measurements of the temperatures in the flow stream and on the tube wall are presented and compared to analysis. These data can be used to benchmark different HTS cable heat transfer and fluid flow analysis approaches.

36 MATERIALS SCIENCE↗

HEAT TRANSFER EXPERIMENTS AND ANALYSIS OF A SIMULATED HTS CABLE

Long-length high temperature superconducting (HIS) cable projects, over 1 km, are being designed that are cooled by flowing liquid nitrogen. The compact counter-flow cooling arrangement which has the supply and return stream in a single cryostat offers several advantages including smallest space requirement, least heat load, and reduced cost since a return cryostat is not required. One issue in long length HIS cable systems is the magnitude of the heat transfer radially through the cable. It is extremely difficult to instrument an HIS cable in service on the grid with the needed thermometry because of the issues associated with installing thermometers on high voltage components. A 5-meter long test system has been built that simulates a counter-flow cooled, HIS cable using a heated tube to simulate the cable. Measurements of the temperatures in the flow stream and on the tube wall can be made and compared to analysis. These data can be used to benchmark different HIS cable heat transfer and fluid flow analysis approaches.

36 MATERIALS SCIENCE↗

Tabulation of data from tests of an NPL 9510 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

The tabulated data from tests of a six inch chord NPL 9510 airfoil in the Langley 0.3-Meter Transonic Cryogenic Tunnel. The tests were performed over the following range of conditions: Mach numbers of 0.35 to 0.82, total temperature of 94 K to 300 K, total pressure of 1.20 to 5.81 atm, Reynolds number based on chord of 1.34 x 10 to the 6th to 48.23 x 10 to the 6th, and angle of attack of 0 deg to 6 deg. The NPL 9510 airfoil was observed to have decreasing drag coefficient up to the highest test Reynolds number.

Jenkins, R. V.↗

Design and Execution of the Hypersonic Inflatable Aerodynamic Decelerator Large-Article Wind Tunnel Experiment

The testing of 3- and 6-meter diameter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test articles was completed in the National Full-Scale Aerodynamics Complex 40 ft x 80 ft Wind Tunnel test section. Both models were stacked tori, constructed as 60 degree half-angle sphere cones. The 3-meter HIAD was tested in two configurations. The first 3-meter configuration utilized an instrumented flexible aerodynamic skin covering the inflatable aeroshell surface, while the second configuration employed a flight-like flexible thermal protection system. The 6-meter HIAD was tested in two structural configurations (with and without an aft-mounted stiffening torus near the shoulder), both utilizing an instrumented aerodynamic skin.

Cassell, Alan M.↗