Search NASA⌕ Search

SEARCH · Search NASA

Results for “metric standardization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Regulatory Implications of Embedded Grid Energy Storage

Electricity is unique among commodities in that its supply chain was developed without a storage component. Every other resource commodity has the ability to store excess quantities built into its supply chain – in the form of granaries, warehouses, reservoirs, etc. This embedded storage creates a buffer for mismatches between supply and demand, stabilizing prices and protecting customers. Recent technological advances in cost-competitive energy storage technologies that are scalable and flexible have made the concept of embedded electrical storage feasible, but several regulatory questions remain. This paper summarizes energy regulatory structures in the U.S. and the implications that they would have for embedded storage on the electric grid. Regulatory challenges for embedded storage include the lack of underlying standards, inclusion in planning processes, ownership models, compensation, and metrics. Two possible pathways forward are explored: an incremental one including regulatory guidance regarding the evaluation of embedded storage in existing planning processes, and a complex one involving the revision of existing reliability standards or the development of a new standard specific to embedded storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessing the sensitivity and repeatability of permanganate oxidizable carbon as a soil health metric: An interlab comparison across soils

Soil organic matter is central to the soil health framework. Therefore, reliable indicators of Soil organic matter is central to the soil health framework. Therefore, reliable indicators of changes in soil organic matter are essential to inform land management decisions. Permanganate oxidizable carbon (PDXC), an emerging soil health indicator, has shown promise for being sensitive to soil management. However, strict standardization is required for widespread implementation in research and commercial contexts. Here, we used 36 soils-three from each of the 12 USDA soil orders-to determine the effects of sieve size and soil mass of analysis on PDXC results. Using replicated measurements across 12 labs in the US and the EU (n = 7951 samples), we quantified the relative importance of 1) variation between labs, 2) variation within labs, 3) effect soil mass, and 4) effect of soil sieve size on the repeatability of PDXC. We found a wide range of overall variability in PDXC values across labs (0.03 to 171.8%; mean = 13.4%), and much of this variability was attributable to within-lab variation (median = 6.5%) independently of soil mass or sieve size. Greater soil mass (2.5 g) decreased absolute PDXC values by a mean of 177 mg kg -1 soil and decreased analytical variability by 6.5%. For soils with organic carbon (SOC) >10%, greater soil mass (2.5 g) resulted in more frequent PDXC values above the limit of detection whereas the lower soil mass (0.75 g) resulted in PDXC values below the limit of detection for SOC contents <5%. A finer sieve size increased absolute values of PDXC by 124 mg kg -1 while decreasing the analytical variability by 1.8%. In general, soils with greater SOC contents had lower analytical variability. These results point to potential standardizations of the PDXC protocol that can decrease the variability of the metric. We recommend that the PDXC protocol be standardized to use 2.5 g for soils <10% SOC. Sieve size was a relatively small contributor to analytical variability and therefore we recommend that this decision be tailored to the study purpose. Tradeoffs associated with these standardizations can be mitigated, ultimately providing guidance on how to standardize PDXC for routine analysis.

54 ENVIRONMENTAL SCIENCES↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global wave energy resource classification system for regional energy planning and project development

Efforts to streamline and codify wave energy resource characterization and assessment for regional energy planning and wave energy converter (WEC) project development have motivated the recent development of resource classification systems. Given the unique interplay between WEC absorption and resource attributes, viz, available wave power frequency, directionality, and seasonality, various consensus resource classification metrics have been introduced. However, the main international standards body for the wave energy industry has not reached consensus on a wave energy resource classification system designed with clear goals to facilitate resource assessment, regional energy planning, project site selection, project feasibility studies, and selection of WEC concepts or archetypes that are most suitable for a given wave energy climate. In this work, a primary consideration of wave energy generation is the available energy that can be captured by WECs with different resonant frequency and directional bandwidths. Therefore, the proposed classification system considers combinations of three different wave power classifications: the total wave power, the frequency-constrained wave power, and the frequency-directionally constrained wave power. The dominant wave period bands containing the most wave power are sub-classification parameters that provide useful information for designing frequency and directionally constrained WECs. The bulk of the global wave energy resource is divided into just 22 resource classes representing distinct wave energy climates that could serve as a common language and reference framework for wave energy resource assessment if codified within international standards.

16 TIDAL AND WAVE POWER↗

Feasibility of Vascular Parameter Estimation for Assessing Hypertensive Pregnancy Disorders

Abstract Hypertensive pregnancy disorders (HPDs), such as pre-eclampsia, are leading sources of both maternal and fetal morbidity in pregnancy. Noninvasive imaging, such as ultrasound (US) and magnetic resonance imaging (MRI), is an important tool for predicting and monitoring these high risk pregnancies. While imaging can measure hemodynamic parameters, such as uterine artery pulsatility and resistivity indices (PI and RI), the interpretation of such metrics for disease assessment relies on ad hoc standards, which provide limited insight to the physical mechanisms underlying the emergence of hypertensive pregnancy disorders. To provide meaningful interpretation of measured hemodynamic data in patients, advances in computational fluid dynamics can be brought to bear. In this work, we develop a patient-specific computational framework that combines Bayesian inference with a reduced-order fluid dynamics model to infer parameters, such as vascular resistance, compliance, and vessel cross-sectional area, known to be related to the development of hypertension. The proposed framework enables the prediction of hemodynamic quantities of interest, such as pressure and velocity, directly from sparse and noisy MRI measurements. We illustrate the effectiveness of this approach in two systemic arterial network geometries: an aorta with branching carotid artery and a maternal pelvic arterial network. For both cases, the model can reconstruct the provided measurements and infer parameters of interest. In the case of the maternal pelvic arteries, the model can make a distinction between the pregnancies destined to develop hypertension and those that remain normotensive, expressed through the value range of the predicted absolute pressure.

Biophysics↗

Rapid identification of enteric bacteria from whole genome sequences using average nucleotide identity metrics

Identification of enteric bacteria species by whole genome sequence (WGS) analysis requires a rapid and an easily standardized approach. We leveraged the principles of average nucleotide identity using MUMmer (ANIm) software, which calculates the percent bases aligned between two bacterial genomes and their corresponding ANI values, to set threshold values for determining species consistent with the conventional identification methods of known species. The performance of species identification was evaluated using two datasets: the Reference Genome Dataset v2 (RGDv2), consisting of 43 enteric genome assemblies representing 32 species, and the Test Genome Dataset (TGDv1), comprising 454 genome assemblies which is designed to represent all species needed to query for identification, as well as rare and closely related species. The RGDv2 contains six Campylobacter spp., three Escherichia/Shigella spp., one Grimontia hollisae, six Listeria spp., one Photobacterium damselae, two Salmonella spp., and thirteen Vibrio spp., while the TGDv1 contains 454 enteric bacterial genomes representing 42 different species. The analysis showed that, when a standard minimum of 70% genome bases alignment existed, the ANI threshold values determined for these species were ≥95 for Escherichia/Shigella and Vibrio species, ≥93% for Salmonella species, and ≥92% for Campylobacter and Listeria species. Using these metrics, the RGDv2 accurately classified all validation strains in TGDv1 at the species level, which is consistent with the classification based on previous gold standard methods.

59 BASIC BIOLOGICAL SCIENCES↗

Independent Review of Paducah Gaseous Diffusion Plant Freon Release Authorized Limits and Evaluation of Corresponding Radiological Doses

The Portsmouth/Paducah Project Office (PPPO) proposes to use the American National Standard Institute (ANSI)/Health Physics Society (HPS) N13.12 (ANSI 2013) volumetric screening levels as Authorized Limits (ALs) for the release of cryofluorane R-114 (Freon) at the Paducah Gaseous Diffusion Plant (PGDP) in Paducah, Kentucky. A review of the proposed ALs document indicated that potential exposure scenarios from the release of Freon are adequately discussed therein. However, questions arose regarding the assumptions made for the ANSI N13.12 clearance values, and whether or not all pathway doses were adequately considered in the Authorized Limits Request. For example, PPPO used the inverse square rule to estimate dose to the truck driver. A more appropriate evaluation would have considered the material as a cylindrical source for this pathway. In addition, the inverse square rule was inadequately applied to the inhalation and ingestion pathways. Furthermore, while the ANSI N13.12 volumetric clearance values are used in the ALs, questions arose concerning whether the values are appropriate for materials of greater than 1 metric ton, and whether or not the ANSI N13.12 standard could be used for liquids that are sent to an incinerator. For these reasons, dose modeling was conducted to demonstrate that using ANSI/HPS N13.12 screening levels as ALs for release of PGDP Freon meets the dose criteria set in U.S. Department of Energy (DOE) Order 458.1. This report provides a bounding dose analysis using scenarios described in PPPO document. Realistic parameters, such as the incinerator characteristics data, are used when available.

61 RADIATION PROTECTION AND DOSIMETRY↗

Solution Irregularity Remediation for Spatial Discretization Error Estimation for S N Transport Solutions

The discrete ordinates linear Boltzmann transport equation is typically solved in its spatially discretized form, incurring spatial discretization error. Quantification of this error for purposes such as adaptive mesh refinement or error analysis requires an a posteriori estimator, which utilizes the numerical solution to the spatially discretized equation to compute an estimate. Because the quality of the numerical solution informs the error estimate, irregularities, present in the true solution for any realistic problem configuration, tend to cause the largest deviation in the error estimate vis-a-vis the true error. In this paper, an analytical partial singular characteristic tracking (pSCT) procedure for reducing the estimator’s error is implemented within our novel residual source estimator for a zeroth-order discontinuous Galerkin scheme, at the additional cost of a single inner iteration. Here, a metric-based evaluation of the pSCT scheme versus the standard residual source estimator is performed over the parameter range of a Method of Manufactured Solutions test suite. The pSCT scheme generates near-ideal accuracy in the estimate in problems where the dominant source of the estimator’s error is the solution irregularity, namely, problems where the true solution is discontinuous and problems where the true solution’s first derivative is discontinuous and the scattering ratio is low. In problems where the scattering ratio is high and the true solution is discontinuous in the first derivative, the error in the scattering source, which is not converged by the pSCT scheme, is greater than the error incurred due to the irregularity. Ultimately, a pSCT scheme is judged to be useful for error estimation in problems where the computational cost of the scheme is justified. In the presence of many irregularities, such a scheme may be intractable for general use, but in benchmarks, as an analytical tool, or in problems that have nondissipative discontinuities, the scheme may prove invaluable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probabilistic Nanomagnetic Memories for Uncertain and Robust Machine Learning

This project evaluated the use of emerging spintronic memory devices for robust and efficient variational inference schemes. Variational inference (VI) schemes, which constrain the distribution for each weight to be a Gaussian distribution with a mean and standard deviation, are a tractable method for calculating posterior distributions of weights in a Bayesian neural network such that this neural network can also be trained using the powerful backpropagation algorithm. Our project focuses on domain-wall magnetic tunnel junctions (DW-MTJs), a powerful multi-functional spintronic synapse design that can achieve low power switching while also opening the pathway towards repeatable, analog operation using fabricated notches. Our initial efforts to employ DW-MTJs as an all-in-one stochastic synapse with both a mean and standard deviation didn’t end up meeting the quality metrics for hardware-friendly VI. In the future, new device stacks and methods for expressive anisotropy modification may make this idea still possible. However, as a fall back that immediately satisfies our requirements, we invented and detailed how the combination of a DW-MTJ synapse encoding the mean and a probabilistic Bayes-MTJ device, programmed via a ferroelectric or ionically modifiable layer, can robustly and expressively implement VI. This design includes a physics-informed small circuit model, that was scaled up to perform and demonstrate rigorous uncertainty quantification applications, up to and including small convolutional networks on a grayscale image classification task, and larger (Residual) networks implementing multi-channel image classification. Lastly, as these results and ideas all depend upon the idea of an inference application where weights (spintronic memory states) remain non-volatile, the retention of these synapses for the notched case was further interrogated. These investigations revealed and emphasized the importance of both notch geometry and anisotropy modification in order to further enhance the endurance of written spintronic states. In the near future, these results will be mapped to effective predictions for room temperature and elevated operation DW-MTJ memory retention, and experimentally verified when devices become available.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Next-Generation Marine Energy Software Needs Assessment

The U.S. Department of Energy (DOE) Water Power Technologies Office’s (WPTO) initial investment in marine energy software was driven by needs identified over a decade ago. WPTO-funded research was first launched because of a U.S. congressional mandate that called for the DOE to officially research marine energy technologies, which also established the DOE WPTO in 2008. A congressional mandate requested the WPTO to evaluate a variety of marine energy devices, establish baseline levelized cost of energy estimates, and provide an overall report to Congress. This congressional mandate led to the Reference Model Project (RMP), for which WPTO funded a national multi-laboratory team to develop these reference models, based on state-of-the-art designs of six marine energy converter archetypes that consisted of three current energy converters and three wave energy converters (WEC). Each device was designed to operate for a specific marine resource, thus allowing the devices to serve as reference models for future studies. The RMP congressional report cited the need for improved marine energy software to handle a variety of device designs, as well as a need to standardize performance outputs. Without validated software packages and established metrics, information presented to the WPTO by technology developers could be incorrect or inaccurate and result in misleading conclusions. The recommendation to coordinate WPTO investment in software for numerical modeling and analysis was given a high priority because it would directly fill needs at the time, and focused funding would amplify impact. By sponsoring software development, WPTO would provide industry developers, university researchers, and national laboratories software that could be used, customized, and advanced, thus supporting the overall advancement of marine energy.

16 TIDAL AND WAVE POWER↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

On the structure of isometrically embeddable metric spaces

Since its popularization in the 1970s, the Fiedler vector of a graph has become a standard tool for clustering of the vertices of the graph. Recently, Mendel and Noar, Dumitriu and Radcliffe, and Radcliffe and Williamson have introduced geometric generalizations of the Fiedler vector. Motivated by questions stemming from their work, we provide structural characterizations for when a finite metric space can be isometrically embedded in a Hilbert space.

97 MATHEMATICS AND COMPUTING↗

CPES-QSM: A Quantitative Method Towards the Secure Operation of Cyber-Physical Energy Systems

Power systems are evolving into cyber-physical energy systems (CPES) mainly due to the integration of modern communication and Internet-of-Things (IoT) devices. CPES security evaluation is challenging since the physical and cyber layers are often not considered holistically. Existing literature focuses on only optimizing the operation of either the physical or cyber layer while ignoring the interactions between them. This paper proposes a metric, the Cyber-Physical Energy System Quantitative Security Metric (CPES-QSM), that quantifies the interaction between the cyber and physical layers across three domains: electrical, cyber-risk, and network topology. A method for incorporating the proposed cyber-metric into operational decisions is also proposed by formulating a cyber-constrained AC optimal power flow (C-ACOPF) that considers the status of all the CPES layers. The C-ACOPF considers the vulnerabilities of physical and cyber networks by incorporating factors such as voltage stability, contingencies, graph-theory, and IoT cyber risks, while using a multi-criteria decision-making technique. We note that simulation studies are conducted using standard IEEE test systems to evaluate the effectiveness of the proposed metric and the C-ACOPF formulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A review of regulatory standard test methods for residential wood heaters and recommendations for their advancement

In many regions, residential wood heaters are a leading source of harmful air pollution but only satisfy a small portion of local heating demands. In response, standardized laboratory test methods have been developed to characterize and limit wood heater emissions. While these test methods are a key tool for advancing both wood heater technology and environmental regulations, many of the experimental procedures are outdated and provide few actionable insights for improving heater performance. Furthermore, these test methods vary widely around the world and may not adequately capture the performance of wood heaters operating in residences. This study presents a comprehensive review of standardized wood heater test methods to identify fundamental experimental objectives and regulated performance metrics. Using the results of this review, recommendations are provided to make the test methods more accessible and representative of residential performance, while generating actionable data to motivate heater design improvements. This study elucidates the current state of standard test methods, and the developments needed to advance clean wood heater technologies and public policies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Guide for Improved Resource Adequacy Assessments in Evolving Power Systems: Institutional and Technical Dimensions

This paper identifies and evaluates issues in traditional resource adequacy (RA) assessment practices, and how adjusting these practices may affect and depend on existing institutional arrangements for planning and procurement. The paper proposes a technical-institutional roadmap that would allow regulators in vertically-integrated jurisdictions and system planners and operators in restructured jurisdictions to revise RA practices across a range of components. First, we compile a critical review of current RA assessment practices based on (1) interviews with RA practitioners and (2) a review of recent technical literature. We find that (i) RA may need to expand beyond capacity adequacy to ensure energy adequacy – relevant for energy-limited resources such as storage – and potentially some form of ancillary service adequacy (e.g. enough ramping-up and ramping-down capability in the system); (ii) chronological hourly simulations for all hours in the year are the current best practice; (iii) metrics and models used do not reflect economic criteria in system operation and loss of load; and (iv) there is a need to improve representation of weather dependencies and weather data. Second, we review planning and RA reports for several private and public entities that plan generation and/or transmission infrastructure in the continental U.S. to look for existing practices involving resilience assessments. We find no systematic treatment of the costs of extreme weather and other hazards, the benefits of resilience, and resilience metrics in planning analyses and no systematic treatment of resilience metrics, methods, and outcomes for resource adequacy purposes. Third, we create a technical framework for probabilistic RA assessment and use it to study how key choices about how to model power system operations affect the values that are obtained for RA metrics. We find that (i) non-economic dispatch schemes that ignore economic objectives can lead to accurate RA assessments when coordinated with detailed operational strategies; (ii) multi-year data is critical to capture a wide variety of system conditions; (iii) not incorporating transmission limits into RA assessment could lead to substantial underestimation of traditional “expected value” RA metrics; and (iv) new RA metrics that capture event-specific shortfall characteristics should be used as supplements to traditional metrics. Finally, we examine RA assessments and use this information to propose a guide of evolving industry standards for resource adequacy assessments in resource planning and transmission planning. We report minimum, best, and frontier practices for temporal resolution of assessments, metrics and targets, weather data, load forecasting, characterization of variable renewable resources, characterization of transmission and market transactions, RA modeling and integration with planning processes, and capacity accreditation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗