Search NASA⌕ Search

SEARCH · Search NASA

Results for “microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Microfluidic film evaporation with femtosecond laser-patterned surface

Systems, apparatuses, and methods for microfluidic fluid evaporation using femtosecond laser-patterned surfaces are disclosed. A microfluidic device may comprise a femtosecond laser-patterned substrate having at least one input path and at least one output path. The femtosecond laser-patterned substrate may comprise both superhydrophobic and superhydrophilic sections. Fluid deposited at an input path may be wicked to an output path due to the surface pattern. A heating device may be provided to heat the fluid to evaporate volatiles therefrom. Vacuums and gas streams may be used to aid in volatile removal. Gas streams may add gas to the microfluidic device to react with the fluid.

Pearson, Connor Daniel↗

Wearable Microfluidic Diaphragm Pressure Sensor for Health and Tactile Touch Monitoring

Flexible pressure sensors have many potential applications in wearable electronics, robotics, health monitoring, and more. In particular, liquid-metal-based sensors are especially promising as they can undergo strains of over 200% without failure. However, current liquid-metal-based strain sensors are incapable of resolving small pressure changes in the few kPa range, making them unsuitable for applications such as heart-rate monitoring, which require a much lower pressure detection resolution. In this paper, a microfluidic tactile diaphragm pressure sensor based on embedded Galinstan microchannels (70 µm width × 70 µm height) capable of resolving sub-50 Pa changes in pressure with sub-100 Pa detection limits and a response time of 90 ms is demonstrated. An embedded equivalent Wheatstone bridge circuit makes the most of tangential and radial strain fields, leading to high sensitivities of a 0.0835 kPa -1 change in output voltage. The Wheatstone bridge also provides temperature self-compensation, allowing for operation in the range of 20–50 °C. Finally, as examples of potential applications, a polydimethylsiloxane (PDMS) wristband with an embedded microfluidic diaphragm pressure sensor capable of real-time pulse monitoring and a PDMS glove with multiple embedded sensors to provide comprehensive tactile feedback of a human hand when touching or holding objects are demonstrated.

47 OTHER INSTRUMENTATION↗

miRNA detection at single-cell resolution using microfluidic LNA flow-FISH

Flow cytometry in combination with fluorescent in situ hybridization (flow-FISH) is a powerful technique that can be utilized to rapidly detect nucleic acids at single-cell resolution without the need for homogenization or nucleic acid extraction. Here, we describe a microfluidic-based method which enables the detection of microRNAs or miRNAs in single intact cells by flow-FISH using locked nucleic acid (LNA)-containing probes. Our method can be applied to all RNA species including mRNA and small noncoding RNA and is suitable for multiplexing with protein immunostaining in the same cell. For demonstration of our method, this chapter details the detection of miR155 and CD69 protein in PMA and ionomycin-stimulated Jurkat cells. Here, we also include instructions on how to set up a microfluidic chip sample preparation station to prepare cells for imaging and analysis on a commercial flow cytometer or a custom-built micro-flow cytometer.

59 BASIC BIOLOGICAL SCIENCES↗

“Development and application of analytical detection techniques for droplet-based microfluidics”-A review

Droplet-based microfluidics has emerged as a powerful platform for high-throughput and low-volume analysis and screening. At present, droplet-based microfluidics is transitioning from the proof-of-concept stage to real-world applications. During this process, analytical detection techniques play indispensable roles for successfully implementing droplet-based chemical or biological assays. Here, we provide an overview of recent developments in analytical techniques for droplet analysis and elucidate the advantages and limitations of each technique. We cover the majority of technology categories, including optical detection, electrical detection, mass spectrometry, and nuclear magnetic resonance spectroscopy. Additionally, we highlight new research areas that have been enabled by these technical advances. Finally, we provide perspectives on both future technological directions and potential enabling applications.

47 OTHER INSTRUMENTATION↗

Effectiveness of supercritical-CO 2 and N 2 huff-and-puff methods of enhanced oil recovery in shale fracture networks using microfluidic experiments

Current oil recovery methods in hydraulically fractured shale reservoirs have a low recovery efficiency of about 10%. The objective of this work is to investigate the effectiveness of nitrogen and supercritical carbon dioxide in the huff-and-puff method for enhanced oil recovery as a means to re-energize reservoirs and improve recovery rates. Here, we conduct direct visualization experiments with a microfluidic system to reveal the mechanisms and to quantify the recovery rates of oil from fracture networks. We compared the effectiveness of water, nitrogen and supercritical carbon dioxide at reservoir conditions in a process mimicking the huff-and-puff method in both dead-end and connected fracture systems. The microfluidic chips were made of glass and placed in a confining pressure system pressurized to 10 MPa, 50 °C. The system was allowed to equilibrate, and then depressurized to simulate huff-and-puff oil recovery. Fluorescence microscope images were continuously taken to visualize and calculate residual oil saturation as a function of pressure drawdown. As the system was depressurized from 10 MPa, gas exsolution from the oil liquid phase, including bubble nucleation, growth, and coalescence, appeared to be the main driver for mobilizing oil from the fracture networks. Injection of supercritical CO 2 resulted in the highest recovery rate with an average end-point recovery of about 90% in the connected fracture network and 60% in the dead-end fracture network. N 2 has lower solubility in oil and hence showed a lower recovery rate of 40% in the connected fracture network and 25% in the dead-end fracture network. Injection of water had no effect on oil mobilization since water is insoluble, immiscible and incompressible. The main mechanism of enhanced recovery was gas exsolution from the liquid phase as pressure was decreased below the bubble point pressure. Because the gas was distributed throughout the oil phase, bubble nucleation, growth, coalescence, and elongation occurred throughout the fracture network. Expansion of the gas forced oil out of the network through piston displacement in continuous oil areas and film flow in the dispersed oil areas. Bubbles began as spheres and grew until they touched the fracture walls where they elongated along the fracture length. The bubble growth rate depended on local mass transfer from liquid to gas phase and gas volume expansion due to pressure drop. The efficiency of the huff-and-puff process is dependent on the solubility and miscibility of the injection fluid with oil. High gas solubility allows for more bubble nucleation, growth and expansion during the depressurization cycle.

58 GEOSCIENCES↗

A microfluidic spore chamber for long-term imaging of single-spore hyphal development.

Understanding the life cycle of fungal spores is essential for elucidating their roles in pathogenesis, dispersal, and survival. However, studying spore development under controlled, spatially defined conditions remains challenging. Here, we present the Spore Chamber, a custom-built microfluidic platform engineered for parallel trapping and long-term imaging of individual spores under defined media conditions, enabling real-time visualization of hyphal development. Using Aspergillus fumigatus as a model organism, we demonstrate that sparse trapping of individual spores within size-matched trap geometries enables long-term time-lapse imaging of key developmental stages, including germination, polarized hyphal elongation, branching, and conidiophore formation. To assess the device's capacity to resolve morphogenetic responses to exogenous signals, we introduced lipochitooligosaccharides (LCOs) and short-chain chitooligosaccharides (COs). Rhizobium-derived, non-sulfated LCO (nsLCO) mixtures induced enhanced secondary branching (hyperbranching), a response not previously reported in A. fumigatus under these signal conditions, to our knowledge, whereas sulfated LCOs and CO4 did not significantly alter branching patterns. In addition, long-term confinement and imaging revealed rare developmental morphologies previously described primarily in mutant strains, including split conidiophore formation, elongated phialides, and stress-associated phenomena such as microcyclic conidiation, and chlamydospore development. Together, these results establish the Spore Chamber as a targeted microfluidic platform for single-spore phenotyping and long-term developmental analysis, with applications in fungal biology, chemical signaling studies, and host–microbe interaction research.

Antifungal screening↗

Synthesis of U 3 O 8 and UO 2 microspheres using microfluidics

Uranium-bearing microspheres below 50µm with a narrow size distribution allows for a wider variety of fuel forms. To accommodate the smaller size, gel microspheres with a composition of UO 3 ∙nH 2 O∙mNH 3 were synthesized using microfluidics and subsequently converted to U 3 O 8 and UO 2 . To accommodate the slower flow rates required by microfluidics, a more stable broth was established. Additionally, the gelation studies resulted in a broth that was stable for more than two days at 0°C and for close to 3 h at room temperature while still gelling within 25 s. Synthesis of gel microspheres with a narrow size distribution lasted for 5 h and produced ~0.5 g of air-dried material. The gelled microspheres were converted to U 3 O 8 and UO 2 and with sizes of 50 and 40 µm in diameter, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enabling Microscale Processing: Combined Raman and Absorbance Spectroscopy for Microfluidic On-Line Monitoring

Microfluidics have many potential applications including characterization of chemical processes on a reduced scale, spanning the study of reaction kinetics using on-chip liquid–liquid extractions, sample pretreatment to simplify off-chip analysis, and for portable spectroscopic analyses. The use of in situ characterization of process streams from laboratory-scale and microscale experiments on the same chemical system can provide comprehensive understanding and in-depth analysis of any similarities or differences between process conditions at different scales. A well-characterized extraction of Nd(NO 3 ) 3 from an aqueous phase of varying NO 3– (aq) concentration with tributyl phosphate (TBP) in dodecane was the focus of this microscale study and was compared to an earlier laboratory-scale study utilizing counter current extraction equipment. Here, we verify that this same extraction process can be followed on the microscale using spectroscopic methods adapted for microfluidic measurement. Concentration of Nd (based on UV–vis) and nitrate (based on Raman) was chemometrically measured during the flow experiment, and resulting data were used to determine the distribution ratio for Nd. Extraction distributions measured on the microscale were compared favorably with those determined on the laboratory scale in the earlier study. Both micro-Raman and micro-UV–vis spectroscopy can be used to determine fundamental parameters with significantly reduced sample size as compared to traditional laboratory-scale approaches. This leads naturally to time, cost, and waste reductions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microfluidic, One-Batch Synthesis of Pd Nanocrystals on N-Doped Carbon in Surfactant-Free Deep Eutectic Solvents for Formic Acid Electrochemical Oxidation

One of the grand challenges that impedes practical applications of nanomaterials is the lack of robust manufacturing methods that are scalable, cheap, and environmentally friendly. In this work, we address this challenge by developing a microfluidic approach that produces surfactant-free Pd nanocrystals (NCs) uniformly loaded on N-doped porous carbon in a one-batch process. The deep eutectic solvent (DES) prepared from choline chloride and ethylene glycol was employed as a novel synthesis solvent, and its extended hydrogen networks and abundant ionic species effectively stabilize Pd facets and confine nanocrystal sizes without using surfactants. The microreactors provide faster heat exchange and more uniform mass transport, which in combination with DES produced Pd NCs with better-defined shape and predominately exposed Pd (100) facet. Furthermore, we describe that the N-doped functional groups in porous carbon direct dense and uniform heterogeneous growth of Pd NCs in a one-batch process, thereby eliminating a separate catalyst deposition step that is often involved in conventional synthesis. The Pd NCs in the one-batch-produced Pd/C catalysts exhibited a size distribution of similar to ~13 ± 3.5 nm and a high ESCA of 46.0 m 2 /g and delivered 362 mA/mg for formic acid electrochemical oxidation with improved stability, demonstrating the unique potentials of microfluidic reactors and DES for the controllable and scalable synthesis of electrocatalyst materials for practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metal–Organic Framework-Based Microfluidic Impedance Sensor Platform for Ultrasensitive Detection of Perfluorooctanesulfonate

The growing global concerns to public health from human exposure to perfluorooctanesulfonate (PFOS) requires rapid, sensitive, in-situ detection where current, state-of-the-art techniques are yet to adequately meet sensitivity and selectivity standards of the real-world. This work presents, for the first time, a synergistic approach for the targeted affinity-based capture of PFOS using a porous sorbent probe that enhances detection sensitivity by embedding it on a microfluidic conductive platform. This novel sorbent-containing platform functions as an electrochemical sensor to directly measure PFOS concentration through a proportional change in electrical response (increase in impedance). The extremely high surface area and pore volume of mesoporous metal-organic framework (MOF) Cr-MIL-101 is used as the probe for targeted PFOS capture based on the affinity of the chromium center towards both the fluorine tail groups as well as the sulfonate functionalities as demonstrated by spectroscopic (NMR and XPS) and microscopic (TEM) studies. Answering the need for an ultrasensitive PFOS detection technique, we are embedding these MOF capture probes inside a microfluidic channel, sandwiched between interdigitated microelectrodes (IDµE). The nanoporous geometry increases the signal to noise ratio of interdigitated microelectrodes tremendously increasing sensitivity; this in combination with the ability of the capture probes to interact with the PFOS at the molecular level and effectively transduce that response electrochemically has allowed us achieve a PFOS detection limit of 0.5 ng/L, which is unprecedented for in-situ analytical PFOS sensors and even comparable to quantification limits achieved using state-of-the-art ex situ techniques.

36 MATERIALS SCIENCE↗

Microfluidics Synthesis of Gene Silencing Cubosomes

The success of gene technologies hinges on our ability to engineer superior encapsulation and delivery vectors. Cubosomes are lipid-based nanoparticles where membranes, instead of enveloping into classic liposomes, intertwine into complex arrays of pores well-ordered in a cubic lattice. These complex nanoparticles encapsulate large contents of siRNA compared to a liposomal analogue. Importantly, the membranes that form cubosomes have intrinsic fusogenic properties that promote fast endosomal escape. Despite the great potential, traditional routes of forming cubosomes lead to particle sizes too large to fulfill the state-of-the art requirements of delivery vectors. To overcome this challenge, in this work we utilize a microfluidic nanomanufacturing device to synthesize cubosomes and siRNA-loaded cubosomes, termed cuboplexes. Utilizing cryogenic TEM and small angle X-ray scattering we elucidate the time-resolved mechanisms in which microfluidic devices allow the production of small cubosomes and cuboplexes (75 nm) that outperform commercially available delivery vectors, as well as liposome-based systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Sensing of Single-Ligand Delivery with Nanoaperture-Integrated Microfluidic Devices

The measurement of biological events on the surface of live cells at the single-molecule level is complicated by several factors including high protein densities that are incompatible with single-molecule imaging, cellular autofluorescence, and protein mobility on the cell surface. Here, we fabricated a device composed of an array of nanoscale apertures coupled with a microfluidic delivery system to quantify single-ligand interactions with proteins on the cell surface. We cultured live cells directly on the device and isolated individual epidermal growth factor receptors (EGFRs) in the apertures while delivering fluorescently labeled epidermal growth factor. We observed single ligands binding to EGFRs, allowing us to quantify the ligand turnover in real time. These results demonstrate that this nanoaperture-coupled microfluidic device allows for the spatial isolation of individual membrane proteins while maintaining them in their cellular environment, providing the capability to monitor single-ligand binding events while maintaining receptors in their physiological environment. Lastly, these methods should be applicable to a wide range of membrane proteins.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, fabrication and test of a pneumatically controlled, renewable, microfluidic bead trapping device for sequential injection analysis applications

This paper describes the design, fabrication, and testing of a pneumatically controlled,renewable, microfluidic device for conducting bead-based assays in an automated sequential injection analysis system. The device used a “brick wall”-like pillar array (pillar size: 20 μm length X 50 μm width X 45 μm height) with 5 μm gaps between the pillars serving as the micro filter. The flow channel where bead trapping occurred is 500 μm wide X 75 μm deep. An elastomeric membrane and an air chamber were located underneath the flow channel. By applying pressure to the air chamber, the membrane is deformed and pushed upward against the filter structure. This effectively traps beads larger than 5 μm and creates a “bed” or micro column of beads that can be perfused and washed with liquid samples and reagents. Upon completion of the assay process, the pressure is released and the beads are flushed out from underneath the filter structure to renew the device. Mouse IgG was used as a model analyte to test the feasibility of using the proposed device for immunoassay applications. Resulting microbeads from an on-chip fluorescent immunoassay were individually examined using flow cytometry. The results show that the fluorescence signal intensity distribution is fairly narrow indicating high chemical reaction uniformity among the beads population. Electrochemical onchip assay was also conducted. A detection limit of 0.1 ng/mL1 ppb was achieved and good device reliability and repeatability were demonstrated. The novel microfluidic-based beadstrapping device thus opens up a new pathway to design micro-bead based biosensor immunoassays for clinical and othervarious applications.

beads trapping↗

Ionic electroactive polymer actuators as active microfluidic mixers

On-chip sample processing is integral to the continued development of lab-on-a-chip devices for various applications. An active microfluidic mixer prototype is proposed using ionic electroactive polymer actuators (IEAPAs) as artificial cilia. A proof-of-concept experiment was performed in which the actuators were shown to produce localized flow pattern disruptions in the laminar flow regime. Suggestions for further engineering and optimization of a scaled-down, complete device are provided. Furthermore, the device in its current state of development necessitates further engineering, the use of IEAPAs addresses issues currently associated with the use of electromechanical actuators as active microfluidic mixers and may prove to be a useful alternative to other similar materials.

36 MATERIALS SCIENCE↗

Development and testing of a novel micro-Raman probe and application of calibration transfer method for the quantitative analysis of microfluidic nitric acid streams

To simplify and improve the safety of reprocessing used nuclear fuel, an initial assessment was made of Raman microscopy applied to microfluidic volumes with a view toward the on-line spectroscopic measurement of highly radioactive solutions. This study compares a microscopic Raman probe (excitation focal point diameter 70 µm) to a larger, well studied probe (excitation focal point diameter 125 µm) used in prior investigations. This was done by chemometrically modeling and predicting concentrations of HNO3 solutions (0 M to 8 M) as they flowed through microfluidic cells based upon spectra from each probe. Spectra recorded for each probe using the same static HNO3 solution set contained in 2 dram glass vials were used as training sets to produce models for the respective probes. Modeling required baseline, normalization and smoothing preprocessing to compensate for a reduced path length between the static glass vial training set (4 cm) and the reduced path length flow cell (1 cm), wide ranging solution concentrations, and the associated non-linear spectral changes, and abrupt and uneven concentration changes of flowing solutions. The micro-Raman probe is able to produce spectra that may be analyzed chemometrically to accurately predict the concentration of flowing HNO3 solutions down to microliter volumes. Based upon RMSECV and RMSEP modeling statistics concentration predictions of the micro-Raman probe are comparable to those obtained for a macro-Raman on identical samples.

microscopic Raman probe, MicroRaman, nitric acid, ↗

All polymer microfluidic chips—A fixed target sample delivery workhorse for serial crystallography

The development of x-ray free electron laser (XFEL) light sources and serial crystallography methodologies has led to a revolution in protein crystallography, enabling the determination of previously unobtainable protein structures and near-atomic resolution of otherwise poorly diffracting protein crystals. However, to utilize XFEL sources efficiently demands the continuous, rapid delivery of a large number of difficult-to-handle microcrystals to the x-ray beam. A recently developed fixed-target system, in which crystals of interest are enclosed within a sample holder, which is rastered through the x-ray beam, is discussed in detail in this Perspective. The fixed target is easy to use, maintains sample hydration, and can be readily modified to allow a broad range of sample types and different beamline requirements. Recent innovations demonstrate the potential of such microfluidic-based fixed targets to be an all-around “workhorse” for serial crystallography measurements. In conclusion, this Perspective will summarize recent advancements in microfluidic fixed targets for serial crystallography, examine needs for future development, and guide users in designing, choosing, and utilizing a fixed-target sample delivery device for their system.

59 BASIC BIOLOGICAL SCIENCES↗

Wetting transition and fluid trapping in a microfluidic fracture

Immiscible fluid–fluid displacement in confined geometries is a fundamental process occurring in many natural phenomena and technological applications, from geological CO 2 sequestration to microfluidics. Due to the interactions between the fluids and the solid walls, fluid invasion undergoes a wetting transition from complete displacement at low displacement rates to leaving a film of the defending fluid on the confining surfaces at high displacement rates. While most real surfaces are rough, fundamental questions remain about the type of fluid–fluid displacement that can emerge in a confined, rough geometry. Here, we study immiscible displacement in a microfluidic device with a precisely controlled structured surface as an analogue for a rough fracture. We analyze the influence of the degree of surface roughness on the wetting transition and the formation of thin films of the defending liquid. We show experimentally, and rationalize theoretically, that roughness affects both the stability and dewetting dynamics of thin films, leading to distinct late-time morphologies of the undisplaced (trapped) fluid. Finally, we discuss the implications of our observations for geologic and technological applications.

42 ENGINEERING↗

Multimodal Microchannel and Nanowell-Based Microfluidic Platforms for Bioimaging

Modern live-cell imaging approaches permit real-time visualization of biological processes. However, limitations for unicellular organism trapping, culturing and long-term imaging can preclude complete understanding of how such microorganisms respond to perturbations in their local environment or linking single-cell variability to whole population dynamics. We have developed microfluidic platforms to overcome prior technical bottlenecks to allow both chemostat and compartmentalized cellular growth conditions using the same device. Additionally, a nanowell-based platform enables a high throughput approach to scale up compartmentalized imaging optimized within the microfluidic device. These channel and nanowell platforms are complementary, and both provide fine control over the local environment as well as the ability to add/replace media components at any experimental time point.

bioimaging↗