Search NASA⌕ Search

SEARCH · Search NASA

Results for “mobile visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

802.11s Wireless Mesh Network Visualization Application

Results of past experimentation at NASA Johnson Space Center showed that the IEEE 802.11s standard has better performance than the widely implemented alternative protocol B.A.T.M.A.N (Better Approach to Mobile Ad hoc Networking). 802.11s is now formally incorporated into the Wi- Fi 802.11-2012 standard, which specifies a hybrid wireless mesh networking protocol (HWMP). In order to quickly analyze changes to the routing algorithm and to support optimizing the mesh network behavior for our intended application a visualization tool was developed by modifying and integrating open source tools.

Mauldin, James Alexander↗

A Focused Ion Beam-Scanning Transmission Electron Microscopy with Energy-Dispersive X-ray Spectroscopy Study on Technetium Incorporation within Iron Oxides through Fe(OH) 2 (s) Mineral Transformation

Incorporation of Tc(IV) into iron oxide/hydroxide minerals has been explored and proposed as a promising pathway to preventing Tc(IV) reoxidation to environmentally mobile pertechnetate (TcO 4 - ) and improving long-term immobilization of radioactive technetium-99 (Tc). However, visual evidence evaluating the distribution of Tc(IV) incorporated within iron oxide/hydroxide phases has not been available, until now, despite potential implications on Tc(IV) stability within the host phase. For the purpose of this study Tc(IV) incorporation into iron oxide/hydroxide phases was facilitated via Fe(OH) 2 (s) oxidation and mineral transformation to magnetite (Fe 3 O 4 ). Focused ion beam - scanning transmission electron microscopy equipped with energy-dispersive X-ray spectroscopy (FIB/STEM-EDS) methods were then combined with X-ray diffraction and absorption spectroscopy techniques to characterize and visually demonstrate that, for the first time, Tc(IV) is heterogeneously incorporated into different iron oxide/hydroxide phases as Tc(IV)-incorporated magnetite and/or TcO 2 ·2H 2 O(s) via different incorporation mechanisms. Heterogeneous distribution of Tc(IV) in magnetite suggests either (i) TcO4- is reduced quickly at the magnetite surface and then encapsulated into magnetite during continued octahedral crystal growth, or (ii) Tc(IV) alternatively partitioned into multiple layers of a blocky, plate-like morphological magnetite structure showing stratified Tc. With limited Tc-hematite (Fe 2 O 3 ) incorporation, the results suggest that TcO 2 ·2H 2 O(s) is formed and mainly associated/embedded in fibrous nanometer-sized polycrystalline hematite. This work highlights the power of modern state-of-the-art FIB/STEM-EDS approach to provide essential visual insights of the Tc-iron oxide/hydroxide incorporation and generate reliable mechanism-informed designs for waste forms relying on Tc mineral incorporation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Review of planar laser-induced fluorescence measurements in the NASA Langley 31-Inch Mach 10 Air Tunnel

In 2003 a mobile planar laser-induced fluorescence (PLIF) system was constructed at NASA Langley Research Center to visualize and quantify high speed flow fields containing fluorescent species such as nitric oxide (NO). Thereafter, a series of test entries utilizing NO PLIF were conducted in the NASA Langley Research Center’s 31 Inch Mach 10 air wind tunnel, which is a hypersonic blowdown wind tunnel located in Hampton, Virginia. This paper briefly reviews laser-based measurements previously performed in hypersonic blowdown wind tunnel facilities and then details NO PLIF measurement campaigns performed at this facility in the 20 years to date. Measurements were performed to develop 2D and 3D visualization capabilities and quantitatively measure velocity and temperature. Applications described herein include historical models (e.g., Apollo, X-33 and X-43), flight vehicles under development at the time (e.g., Mars Science Lab (MSL), Orion, and LOFTID), as well as fundamental research (e.g., flat plates with and without discrete roughness).

PLIF↗

The Dept. of Energy Artificial Retina Project

LLNL has assisted in the development of the first long-term retinal prosthesis - called an artificial retina - that can function for years inside the harsh biological environment of the eye. This work has been done in collaboration with four national laboratories (Argonne, Los Alamos, Oak Ridge and Sandia), four universities (the California Institute of Technology, the Doheny Eye Institute at USC, North Carolina State University and the University of California, Santa Cruz), an industrial partner (Second Sight® Medical Products Inc. of Sylmar, Calif.) and the U.S. Department of Energy. With this device, application-specific integrated circuits transform digital images from a camera into electric signals in the eye that the brain uses to create a visual image. In clinical trials, patients with vision loss were able to successfully identify objects, increase mobility and detect movement using the artificial retina.

60 APPLIED LIFE SCIENCES↗

Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification

Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Learning and Prediction of Slip from Visual Information

This paper presents an approach for slip prediction from a distance for wheeled ground robots using visual information as input. Large amounts of slippage which can occur on certain surfaces, such as sandy slopes, will negatively affect rover mobility. Therefore, obtaining information about slip before entering such terrain can be very useful for better planning and avoiding these areas. To address this problem, terrain appearance and geometry information about map cells are correlated to the slip measured by the rover while traversing each cell. This relationship is learned from previous experience, so slip can be predicted remotely from visual information only. The proposed method consists of terrain type recognition and nonlinear regression modeling. The method has been implemented and tested offline on several off-road terrains including: soil, sand, gravel, and woodchips. The final slip prediction error is about 20%. The system is intended for improved navigation on steep slopes and rough terrain for Mars rovers.

rover↗

The High Density Vertiplex Advanced Onboard Automation Overview

While many studies have been performed examining Urban Air Mobility (UAM) operations from UAM Maturity Level (UML) UML-1 to UML-4, [1, 2] some uncertainty exists regarding the integration and role of onboard autonomous systems, airspace management systems, ground control and fleet management systems, and how they integrate with vertiport automation systems to ensure safe high-density future operations. One thrust of the Advanced Air Mobility (AAM) High Density Vertiplex (HDV) sub-project is to perform rapid prototyping and assessment of an Urban Air Mobility (UAM) Ecosystem within the terminal operational area to help inform future research investments and technology development. Another thrust within HDV is to perform integration, testing, and safety risk assessments required to acquire operational credit for several NASA small Unmanned Aerial Systems (sUAS) beyond visual line of sight (BVLOS) enabling technologies to expand test capabilities and to expedite technology transfer and ultimate effective usage. Both thrusts leverage sUAS to serve as surrogates for the highly-technologically-similar envisioned UAM aircraft as well as to provide significant contributions to sUAS Part-135 operators. This report provides an overview of the activities accomplished within the Advanced Onboard Automation (AOA) schedule work package of HDV.

Human Factors, Simulation↗

Heavy ion irradiation effects on GaN/AlGaN high electron mobility transistor failure at off-state

We investigate the effects of ion irradiation on AlGaN/GaN high electron mobility electron transistors using in-situ transmission electron microscopy. The experiments are performed inside the microscope to visualize the defects, microstructure and interfaces of ion irradiated transistors during operation and failure. Here, experimental results indicate that heavy ions such as Au 4+ can create a significant number of defects such as vacancies, interstitials and dislocations in the device layer. It is hypothesized that these defects act as charge traps in the device layer and the resulting charge accumulation lowers the breakdown voltage. Sequential energy dispersive X-ray spectroscopy mapping allows us to track individual chemical elements during the experiment, and the results suggest that the electrical degradation in the device layer may originate from oxygen and nitrogen vacancies.

36 MATERIALS SCIENCE↗

Quantitative Discomanometry: Correlation of Intradiscal Pressure Values to Pain Reduction in Patients With Intervertebral Disc Herniation Treated With Percutaneous, Minimally Invasive, Image-Guided Techniques

Purpose: To illustrate quantitative discomanometry's (QD) diagnostic efficacy and predictive value in discogenic-pain evaluation in a prospective study correlating intradiscal pressure values with pain reduction after percutaneous image-guided technique (i.e., percutaneous decompression, PD). Materials and Methods: During the last 3 years, 36 patients [21 male and 15 female (mean age 36 {+-} 5.8 years)] with intervertebral disc hernia underwent QD before PD. Under absolute sterilization and fluoroscopy, a mixture of contrast medium and normal saline (3:1 ratio) was injected. A discmonitor performed a constant rate injection and recorded pressure and volume values, thus producing the relative pressure-volume curve. PD was then performed. Pain reduction and improved mobility were recorded at 3, 12, and 24 months after PD using clinical evaluation and a numeric visual scale (NVS; 0 to 10 units). Results: Mean pain values of 7.5 {+-} 1.9 (range 4 to 8) NVS units were recorded before PD; these decreased to 2.9 {+-} 2.44 at 3 months, 1.0 {+-} 1.9 at 12 months, and 1.0 {+-} 1.9 NVS units at 24 months after PD. Recorded correlations (pressure, volume, significant pain-reduction values) with bilateral statistical significance included a maximum injected volume of 2.4 ml (p = 0.045), P{sub o} < 14 psi [initial pressure required to inject 0.1 ml of the mixture inside the disc (p = 0.05)], P{sub max} {<=} 65 psi [greatest pressure value on the curve (p = 0.018)], and P{sub max} - P{sub o} {<=} 47 psi (p = 0.038). Patients meeting these pressure or volume cut-off points, either independently or as a total, had significant pain reduction (>4 NVS units) after PD. No complications were noted. Conclusions: QD is an efficient technique that may have predictive value for discogenic pain evaluation. It might serve as a useful tool for patient selection for intervertebral disc therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Mobile Agents 2005 Field Test at MDRS: Planning for Exploration

The Mars Society s Desert Research Station (MDRS) Rotation 38, April 3-17, 2005, was dedicated to field tests of NASA's Mobile Agents EVA communications system. MDRS provided an excellent, cost-effective venue for bringing together eighteen scientists and engineers from NASA Ames and Johnson Space Center, in an intensive two weeks of system integration and experiments. The Mobile Agents architecture and collaborative engineering methodology provides a flexible toolkit for configuring extravehicular activity (EVA) components, visualizing and formalizing EVA plans, and automating key supervisory functions.

Clancey, William J.↗

Spherical Coordinate Systems for Streamlining Suited Mobility Analysis

When describing human motion, biomechanists generally report joint angles in terms of Euler angle rotation sequences. However, there are known limitations in using this method to describe complex motions such as the shoulder joint during a baseball pitch. Euler angle notation uses a series of three rotations about an axis where each rotation is dependent upon the preceding rotation. As such, the Euler angles need to be regarded as a set to get accurate angle information. Unfortunately, it is often difficult to visualize and understand these complex motion representations. One of our key functions is to help design engineers understand how a human will perform with new designs and all too often traditional use of Euler rotations becomes as much of a hindrance as a help. It is believed that using a spherical coordinate system will allow ABF personnel to more quickly and easily transmit important mobility data to engineers, in a format that is readily understandable and directly translatable to their design efforts. Objectives: The goal of this project is to establish new analysis and visualization techniques to aid in the examination and comprehension of complex motions. Methods: This project consisted of a series of small sub‐projects, meant to validate and verify the method before it was implemented in the ABF's data analysis practices. The first stage was a proof of concept, where a mechanical test rig was built and instrumented with an inclinometer, so that its angle from horizontal was known. The test rig was tracked in 3D using an optical motion capture system, and its position and orientation were reported in both Euler and spherical reference systems. The rig was meant to simulate flexion/extension, transverse rotation and abduction/adduction of the human shoulder, but without the variability inherent in human motion. In the second phase of the project, the ABF estimated the error inherent in a spherical coordinate system, and evaluated how this error would vary within the reference frame. This stage also involved expanding a kinematic model of the shoulder, to include the torso, knees, ankle, elbows, wrists and neck. Part of this update included adding a representation of 'roll' about an axis, for upper arm and lower leg rotations. The third stage of the project involved creating visualization methods to assist in interpreting motion in a spherical frame. This visualization method will be incorporated in a tool to evaluate a database of suited mobility data, which is currently in development.

Benson, Elizabeth↗

Visualizing Charge Transport and Nanoscale Electrochemistry by Hyperspectral Kelvin Probe Force Microscopy

Charge-transport and electrochemical processes are heavily influenced by the local microstructure. Kelvin probe force microscopy (KPFM) is a widely used technique to map electrochemical potentials at the nanometer scale; however, it offers little information on local charge dynamics. In this study, we implement a hyperspectral KPFM approach for spatially mapping bias-dependent charge dynamics in timescales ranging from the sub-millisecond to the second regime. As a proof of principle, we investigate the role mobile surface charges play in a three-unit-cell LaAlO 3 /SrTiO 3 oxide heterostructure. We explore machine learning approaches to assist with visualization, pattern recognition, and interpretation of the information-rich data sets. Linear unmixing methods reveal hidden bias-dependent interfacial processes, most likely water splitting, which are essentially unnoticed by functional fitting of the dynamic response alone. Hyperspectral KPFM will be beneficial for investigating nanoscale charge transport and local reactivity in systems involving a possible combination of electronic, ionic, and electrochemical phenomena.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ferrorotational domain walls revealed by electric quadrupole second harmonic generation microscopy

Domain walls are ubiquitous in materials that undergo phase transitions driven by spontaneous symmetry breaking. Domain walls in ferroics and multiferroics have received tremendous attention recently due to their emergent properties distinct from their domain counterparts—for example, their high mobility and controllability, as well as their potential applications in nanoelectronics. However, it is extremely challenging to detect, visualize, and study the ferrorotational (FR) domain walls because the FR order, in contrast to ferromagnetism and ferroelectricity, is invariant under both the spatial-inversion and the time-reversal operations and, thus, hardly couple with conventional experimental probes. Here, a FR candidate NiTi⁢O 3 is investigated by ultrasensitive electric quadrupole (EQ) second-harmonic generation rotational anisotropy (SHG RA) to probe the point symmetries of the two degenerate FR domain states, showing their relation by the vertical mirror operations that are broken below the FR critical temperature. We then visualize the real-space FR domains by scanning EQ SHG microscopy, and further, resolve the FR domain walls by revealing a suppressed SHG intensity at the domain walls. By taking local EQ SHG RA measurements, we show the restoration of the mirror symmetry at FR domain walls and prove their unconventional nonpolar nature. In conclusion, our findings not only provide a comprehensive insight into FR domain walls, but also demonstrate a unique and powerful tool for future studies on domain walls of unconventional ferroics both of which pave the way towards future manipulations and applications of FR domain walls.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evolution of LIBS technology to mobile instrumentation for expediting firearm-related investigations at the laboratory and the crime scene

Gunshot residue (GSR) is one of the few forensic disciplines that lack accurate screening techniques. This study proposes using a mobile LIBS instrument to detect inorganic GSR and compares performance to a previously validated laboratory instrument. The mobile LIBS is designed with advanced configurations specifically for on-site GSR analysis, including a CMOS detector and a sampling chamber that holds up to six typical GSR collection devices with separate gas flow ports to prevent cross-contamination. A significant novelty of the portable instrument is its image magnification, which allows quick searching and visualization of GSR particle morphology. The single-particle imaging and elemental composition capability is one of a kind and offers superior confirmatory features for GSR. The mobile LIBS performance was evaluated for residues collected from the hands of shooters (100 samples) and non-shooters (200 background samples), analyzed sequentially by the mobile instrument and then the laboratory instrument. Accuracies better than 98.8% were obtained by both instruments, demonstrating their suitability for trace IGSR detection from skin specimens. Implementation of this methodology is anticipated to drastically speed up response times (i.e., from several hours per sample by standard SEM-EDS practice to a few minutes by LIBS). The screening methods can be easily incorporated into workflows to improve decision-making processes at the crime scene and laboratory settings, reduce backlogs, and improve case management.

47 OTHER INSTRUMENTATION↗

Supplemental macronutrients and microbial fermentation products improve the uptake and transport of foliar applied zinc in sunflower ( Helianthus annuus L.) plants. Studies utilizing micro X-ray florescence

Enhancing nutrient uptake and the subsequent elemental transport from the sites of application to sites of utilization is of great importance to the science and practical field application of foliar fertilizers. The aim of this study was to investigate the mobility of various foliar applied zinc (Zn) formulations in sunflower ( Helianthus annuus L.) and to evaluate the effects of the addition of an organic biostimulant on phloem loading and elemental mobility. This was achieved by application of foliar formulations to the blade of sunflower ( H. annuus L.) and high-resolution elemental imaging with micro X-ray fluorescence (μ-XRF) to visualize Zn within the vascular system of the leaf petiole. Although no significant increase of total Zn in petioles was determined by inductively-coupled plasma mass-spectrometer, μ-XRF elemental imaging showed a clear enrichment of Zn in the vascular tissues within the sunflower petioles treated with foliar fertilizers containing Zn. The concentration of Zn in the vascular of sunflower petioles was increased when Zn was applied with other microelements with EDTA (commercial product Kick-Off) as compared with an equimolar concentration of ZnSO₄ alone. The addition of macronutrients N, P, K (commercial product CleanStart) to the Kick-Off Zn fertilizer, further increased vascular system Zn concentrations while the addition of the microbially derived organic biostimulant “GroZyme” resulted in a remarkable enhancement of Zn concentrations in the petiole vascular system. The study provides direct visualized evidence for phloem transport of foliar applied Zn out of sites of application in plants by using μ-XRF technique, and suggests that the formulation of the foliar applied Zn and the addition of the organic biostimulant GroZyme increases the mobility of Zn following its absorption by the leaf of sunflower.

59 BASIC BIOLOGICAL SCIENCES↗

Integrating Overhead Camera Imagery with Reinforcement Learning to Improve Fuel Economy Through Adaptive Traffic Control

Overhead cameras have been deployed for some time as a sensor for traffic control, with many advantages over conventional inductive loop sensors in terms of robustness, ease of installation, and simplicity with respect to maintenance. We explore the utility of such imagery (in particular, fisheye lens cameras) for intelligent traffic control in real-time using reinforcement learning, with a goal of improving fuel economy for the overall intersection and grid of intersections. We summarize our initial work in data collection and approach to ascertain the ability to visually sense vehicular fuel consumption using real-world data. We then describe our deep reinforcement learning topology to test adaptive control informed by the camera capabilities. Next, we tested the proof-of-concept through a variety of simulation scenarios using the Simulation of Urban Mobility (SUMO) traffic simulator, which included different estimates on vehicle classifications, different traffic distributions, and different traffic densities. Six different control policies were tested ranging from simple timing, to heuristic visual-based methods, to actual policies learned via the reinforcement learning approach. Our results demonstrate the feasibility of the approach for controlling traffic lights for better fuel efficiency based on visual vehicle estimates from commercial, fisheye lens cameras.

Karnowski, Thomas↗

Q-VR: System-Level Design for Future Mobile Collaborative Virtual Reality

High Quality Mobile Virtual Reality (VR) is what the incoming graphics technology era demands: users around the world, regardless of their hardware and network conditions, can all enjoy the immersive virtual experience. However, the state-of-the-art software-based mobile VR designs cannot fully satisfy the realtime performance requirements due to the highly interactive nature of user's actions and complex environmental constraints during VR execution. Inspired by the unique human visual system effects and the strong correlation between VR motion features and realtime hardware-level information, we propose Q-VR, a novel dynamic collaborative rendering solution via software-hardware co-design for enabling future low-latency high-quality mobile VR. At software-level, Q-VR provides flexible high-level tuning interface to reduce network latency while maintaining user perception. At hardware-level, Q-VR accommodates a wide spectrum of hardware and network conditions across users by effectively leveraging the computing capability of the increasingly powerful VR hardware. Extensive evaluation on real-world games demonstrates that Q-VR can achieve an average end-to-end performance speedup of 3.4x (up to 6.7x) over the traditional local rendering design in commercial VR devices, and a 4.1x frame rate improvement over the state-of-the-art static collaborative rendering.

Xie, Chenhao↗

Clinical Outcome and Safety of Multilevel Vertebroplasty: Clinical Experience and Results

To compare safety and efficacy of percutaneous vertebroplasty (PVP) when treating up to three vertebrae or more than three vertebrae per session. We prospectively compared two groups of patients with symptomatic vertebral fractures who had no significant response to conservative therapy. Pathologic substrate included osteoporosis (n = 77), metastasis (n = 24), multiple myeloma (n = 13), hemangioma (n = 15), and lymphoma (n = 1). Group A patients (n = 94) underwent PVP of up to three treated vertebrae (n = 188). Group B patients (n = 36) underwent PVP with more than three treated vertebrae per session (n = 220). Decreased pain and improved mobility were recorded the day after surgery and at 12 and 24 months after surgery per clinical evaluation and the use of numeric visual scales (NVS): the Greek Brief Pain Inventory, a linear analogue self-assessment questionnaire, and a World Health Organization questionnaire. Group A presented with a mean pain score of 7.9 {+-} 1.1 NVS units before PVP, which decreased to 2.1 {+-} 1.6, 2.0 {+-} 1.5 and 2.0 {+-} 1.5 NVS units the day after surgery and at 12 and 24 months after surgery, respectively. Group B presented with a mean pain score of 8.1 {+-} 1.3 NVS units before PVP, which decreased to 2.2 {+-} 1.3, 2.0 {+-} 1.5, and 2.1 {+-} 1.6 NVS units the day after surgery and at 12 and 24 months after surgery, respectively. Overall pain decrease and mobility improvement throughout the follow-up period presented no statistical significance neither between the two groups nor between different underlying aetiology. Reported cement leakages presented no statistical significance between the two groups (p = 0.365). PVP is an efficient and safe technique for symptomatic vertebral fractures independently of the vertebrae number treated per session.

62 RADIOLOGY AND NUCLEAR MEDICINE↗