Search NASA⌕ Search

SEARCH · Search NASA

Results for “modelling studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Notional Chemical Facility PathTrace Modeling Study

This SAND report provides system effectiveness analysis results for notional chemical facilities. Two facilities were analyzed in total, evaluating the effectiveness of the unique security systems in place at each location. Each analysis looked at a range of threat and response capabilities, specific target configurations, and task times to acquire target material in both theft and release scenarios. This report details results for both facilities.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Enhancement of phase change material hysteresis model: A case study of modeling building envelope in EnergyPlus

Nowadays, buildings are expected to offer demand side services to the power grid to enhance the electrical load flexibility, which leads to the concepts of grid-interactive efficient buildings (GEBs). Phase change material (PCM)-based thermal energy storage has seen increasing attention in recent years for peak load shifting of grid-interactive efficient buildings (GEBs). Numerical models are critical tools for design and evaluation of PCM-integrated systems. Most industrial-grade PCMs are reported to melt/freeze over a temperature range instead of at a unique temperature. Such thermal hysteresis effect significantly affects the reliability of simulation results because not only the heat transfer process depends on melting and freezing temperatures, the PCM thermal properties change significantly during the phase change process as well. This study is aimed to develop a model for the PCMs used in the building envelope with the capability to accurately simulate hysteretic behaviors. Further, this model is based on a two-phase assumption and is implemented in a whole building energy performance simulation program (i.e., EnergyPlus). A comparison between numerical results and experimental data shows that during a complete phase transition, the two-phase model could achieve a good agreement with the experimental data. During a partial phase transition, the two-phase model could lead to significant improvements compared to other alternative PCM models, including the existing PCM model in EnergyPlus. Last, whole building simulations were performed to study this model's performance regarding heating/cooling loads and zone mean air temperature of a given building. The results show that the difference in hourly heating/cooling loads introduced by the models was less than 1% in design conditions, while significant changes were observed in both hourly heating/cooling loads and zone mean air temperature when the PCM envelope underwent partial phase transition processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating the Relative Roles of INPs and CCN in a Simulated Thunderstorm Using a New Immersion Freezing Algorithm

Microphysical processes in deep convective clouds are sensitive to the number concentrations of cloud condensation nuclei (CCN) and ice nucleating particles (INPs), but the effects of INPs are less studied. Modeling studies investigating the effects of INPs and/or CCN on deep convection typically retain a volume‐dependent raindrop freezing relation. The resulting neglect of aerosol accumulation in raindrops via drop collisions has likely produced unrealistic storm responses to INPs in past studies. To address this deficiency, a new immersion freezing algorithm was developed and embedded in a bulk microphysics scheme that freezes both cloud drops and raindrops using the same immersion freezing INP (IF‐INP) activity spectrum based on measurements. Multiple idealized simulations of a single case of deep convection observed during the Clouds, Aerosols, and Complex Terrain Interactions (CACTI) field campaign were conducted, with microphysical differences produced by independently altering IF‐INP temperature dependencies and CCN number concentrations from their observed values. Surface precipitation in all simulations resulted almost exclusively from riming graupel that melted upon descending to the surface. Rainfall and cold pools were substantially and systematically weakened with increased CCN due to decreased graupel riming rates but were relatively insensitive to variations in the magnitude and slope of IF‐INP spectra due to compensating depletion of supercooled liquid water. These compensating processes were a consequence of the accumulation of IF‐INPs in raindrops, encouraging caution in studying IF‐INP effects upon thunderstorms using traditional volume‐dependent drop freezing relationships.

CCN↗

Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗

A Model Intercomparison Study of Aerosol‐Cloud‐Turbulence Interactions in a Cloud Chamber: 1. Model Results

This study presents the first model intercomparison of aerosol‐cloud‐turbulence interactions in a controlled cloudy Rayleigh‐Bénard Convection chamber environment, utilizing the Pi Chamber at Michigan Technological University. We analyzed simulated cloud chamber‐averaged statistics of microphysics and thermodynamics in a warm‐phase, cloudy environment under steady‐state conditions at varying aerosol injection rates. Simulation results from seven distinct models (DNS, LES, and a 1D turbulence model) were compared. Our findings demonstrate that while all models qualitatively capture observed trends in droplet number concentration, mean radius, and droplet size distributions at both high and low aerosol injection rates, significant quantitative differences were observed. Notably, droplet number concentrations varied by over two orders of magnitude between models for the same injection rates, indicating sensitivities to the model treatments in droplet activation and removal and wall fluxes. Furthermore, inconsistencies in vertical relative humidity profiles and in achieving steady‐state liquid water content suggest the need for further investigation into the mechanisms driving these variations. Despite these discrepancies, the models generally reproduced consistent power‐law relationships between the microphysical variables. This model intercomparison underscores the importance of controlled cloud chamber experiments for validating and improving cloud microphysical parameterizations. Recommendations for future modeling studies are also highlighted, including constraining wall conditions and processes, investigating droplet/aerosol removal (including sidewall losses), and conducting simplified experiments to isolate specific processes contributing to model divergence and reduce model uncertainties.

54 ENVIRONMENTAL SCIENCES↗

A Potts Model parameter study of particle size, Monte Carlo temperature, and “Particle-Assisted Abnormal Grain Growth”

A Potts Model was proposed to account for temperature and particle heterogeneity-dependent Zener Pinning. This was accomplished by relating the random fluctuations of grain boundary position allowed by the Potts Model switching probability at finite simulation temperature to experimentally observed grain growth stagnation behavior. We assume that these fluctuations arise from random fluctuations in the thermodynamic and kinetic properties of the grain boundaries and/or interfaces as they change with temperature. As an application of this model, the grain growth kinetics of U-10 wt. % Mo nuclear fuels were simulated with the input of microstructural images during different heat treatment processes. Simulated average grain growth behavior is in good agreement with experiments.

Frazier, William E.↗