Search NASA⌕ Search

SEARCH · Search NASA

Results for “module temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

PV Performance Modeling and Stakeholder Engagement (Final Technical Report)

This core capability project’s objective is to increase the value of photovoltaic (PV) performance models by improving their functionality, demonstrating, and quantifying their validity, and offering a wide range of stakeholder engagement opportunities. In FY22-24, we developed new and improved modeling algorithms and functions to represent PV performance more accurately in a variety of environments and conditions. The “Model parameter toolkit” was developed and includes functions to translate between different module temperature models, incidence angle modifier models, and single-diode models. A new modeling capability named “PV Atlas” was also developed leveraging Sandia’s High Performance Computing resources. This capability allows us to investigate several questions and provide climate-specific best practices and geographic data files; all these are hosted on an interactive website on Sandia’s GitHub and can be used for training, system optimization, or to provide best practices for uncertainty reduction. For model validation, we published high-quality PV performance, and weather data; these data are well documented, filtered, and processed for quality and include examples on how to run PV simulations. We also developed well documented, standardized methods for validating PV models and ran independent model validation and 2 blind modeling intercomparisons engaging with 49 organizations from 17 countries. We co-led and contributed to a growing, well documented and maintained suite of open-source functions for PV modeling (i.e., the pvlib-python) and we outreached to the PV modeling stakeholders via the PVPMC workshops and web resources. In addition, this project supported US representation and leadership for the International Energy Agency (IEA) PVPS Task 13; specifically, members of our team led and supported 3 subtasks on: 1) Best practices for the optimization of bifacial photovoltaic tracking, 2) Extreme weather events and their multiple impact on PV power plants: Risks, failure mechanisms and mitigation strategies, and 3) Best practice guidelines for the use of economic and technical Key Performance Indicators (KPIs). This project resulted in the publications of 14 peer reviewed journal papers, 37 conference presentations, 6 SAND reports, 5 public datasets and 6 new webpages on the PVPMC website. It supported the release of 13 pvlib-python versions where 28 enhancements were from this PV Performance Modeling project. We co-organized 5 PVPMC workshops in FY22-24 with the participation of 214 unique institutions and around 700 participants. The PVPMC website was redesigned, and its reliability was improved; it receives over 50,000 visitors/year from 202 unique countries.

14 SOLAR ENERGY↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

Mercury Calibration System

U.S. Environmental Protection Agency (EPA) Performance Specification 12 in the Clean Air Mercury Rule (CAMR) states that a mercury CEM must be calibrated with National Institute for Standards and Technology (NIST)-traceable standards. In early 2009, a NIST traceable standard for elemental mercury CEM calibration still does not exist. Despite the vacature of CAMR by a Federal appeals court in early 2008, a NIST traceable standard is still needed for whatever regulation is implemented in the future. Thermo Fisher is a major vendor providing complete integrated mercury continuous emissions monitoring (CEM) systems to the industry. WRI is participating with EPA, EPRI, NIST, and Thermo Fisher towards the development of the criteria that will be used in the traceability protocols to be issued by EPA. An initial draft of an elemental mercury calibration traceability protocol was distributed for comment to the participating research groups and vendors on a limited basis in early May 2007. In August 2007, EPA issued an interim traceability protocol for elemental mercury calibrators. Various working drafts of the new interim traceability protocols were distributed in late 2008 and early 2009 to participants in the Mercury Standards Working Committee project. The protocols include sections on qualification and certification. The qualification section describes in general terms tests that must be conducted by the calibrator vendors to demonstrate that their calibration equipment meets the minimum requirements to be established by EPA for use in CAMR monitoring. Variables to be examined include linearity, ambient temperature, back pressure, ambient pressure, line voltage, and effects of shipping. None of the procedures were described in detail in the draft interim documents; however they describe what EPA would like to eventually develop. WRI is providing the data and results to EPA for use in developing revised experimental procedures and realistic acceptance criteria based on actual capabilities of the current calibration technology. As part of the current effort, WRI worked with Thermo Fisher elemental mercury calibrator units to conduct qualification experiments to demonstrate their performance characteristics under a variety of conditions and to demonstrate that they qualify for use in the CEM calibration program. Monitoring of speciated mercury is another concern of this research. The mercury emissions from coal-fired power plants are comprised of both elemental and oxidized mercury. Current CEM analyzers are designed to measure elemental mercury only. Oxidized mercury must first be converted to elemental mercury prior to entering the analyzer inlet in order to be measured. CEM systems must demonstrate the ability to measure both elemental and oxidized mercury. This requires the use of oxidized mercury generators with an efficient conversion of the oxidized mercury to elemental mercury. There are currently two basic types of mercuric chloride (HgCl{sub 2}) generators used for this purpose. One is an evaporative HgCl{sub 2} generator, which produces gas standards of known concentration by vaporization of aqueous HgCl{sub 2} solutions and quantitative mixing with a diluent carrier gas. The other is a device that converts the output from an elemental Hg generator to HgCl{sub 2} by means of a chemical reaction with chlorine gas. The Thermo Fisher oxidizer system involves reaction of elemental mercury vapor with chlorine gas at an elevated temperature. The draft interim protocol for oxidized mercury units involving reaction with chlorine gas requires the vendors to demonstrate high efficiency of oxidation of an elemental mercury stream from an elemental mercury vapor generator. The Thermo Fisher oxidizer unit is designed to operate at the power plant stack at the probe outlet. Following oxidation of elemental mercury from reaction with chlorine gas, a high temperature module reduces the mercuric chloride back to elemental mercury. WRI conducted work with a custom laboratory configured stand-alone oxidized mercury generator unit provided by Thermo Fisher to perform experiments to demonstrate the high efficiency of oxidation on reaction with chlorine gas, and reduction back to elemental mercury.

01 COAL, LIGNITE, AND PEAT↗

PV Performance Modeling - Data and Resources

The Photovoltaic (PV) Performance Modeling Collaborative (PVPMC) organized a blind PV performance modeling intercomparison to allow PV modelers to blindly test their models and modeling ability against real system data. Measured weather and irradiance data were provided along with detailed descriptions of PV systems from two locations (Albuquerque, New Mexico, USA and Roskilde, Denmark). Participants were asked to simulate the plane-of-array irradiance, module temperature, and DC power output from six systems and submit their results to Sandia for processing. This dataset includes seven MS-Excel sheets with instructions, notes and all necessary data (weather, irradiance, temperature, power) used for the data analysis of the blind modeling comparison. The hourly data represent six different systems from Albuquerque, NM and Roskilde, Denmark over a period of one year. These data are useful for PV performance model validation studies.

14 SOLAR ENERGY↗

Evaluating decadal predictions of northern hemispheric cyclone frequencies

Mid-latitudinal cyclones are a key factor for understanding regional anomalies in primary meteorological parameters such as temperature or precipitation. Extreme cyclones can produce notable impacts on human society and economy, for example, by causing enormous economic losses through wind damage. Based on 41 annually initialised (1961–2001) hindcast ensembles, this study evaluates the ability of a single-model decadal forecast system (MPI-ESM-LR) to provide skilful probabilistic three-category forecasts (enhanced, normal or decreased) of winter (ONDJFM) extra-tropical cyclone frequency over the Northern Hemisphere with lead times from 1 yr up to a decade. It is shown that these predictions exhibit some significant skill, mainly for lead times of 2–5 yr, especially over the North Atlantic and Pacific. Skill for intense cyclones is generally higher than for all detected systems. A comparison of decadal hindcasts from two different initialisation techniques indicates that initialising from reanalysis fields yields slightly better results for the first forecast winter (month 10–15), while initialisation based on an assimilation experiment provides better skill for lead times between 2 and 5 yr. The reasons and mechanisms behind this predictive skill are subject to future work. Preliminary analyses suggest a strong relationship of the model's skill over the North Atlantic with the ability to predict upper ocean temperatures modulating lower troposphere baroclinicity for the respective area and time scales.

MiKlip↗

Portable He-3 detector cryostat for the far infrared

The design of a portable He-3 cryostat for far infrared detection applications is described, with a cutaway drawing of the cryostat, including bolometer and cooled optics, provided. Consideration is given to the selection and testing of various bolometer materials, including Ge:Ga and Ge:InSb; the resistance-temperature coefficients of the materials examined are presented. The absolute flux calibration of the detector system using a new temperature-modulated cold source method is described.

Radostitz, J. V.↗

Testing flat plate photovoltaic modules for terrestrial environment

New qualification tests have been developed for flat plate photovoltaic modules. Temperature cycling, cyclic pressure load, and humidity exposure are especially useful for detecting design and fabrication deficiencies. There is positive correlation between many of the observed field effects, such as power loss, and qualification test induced degradation. The status of research efforts for the development of test methodology for field-related problems is reviewed.

Hoffman, A. R.↗

Temperature Controller for a Solar Furnace

Relatively-simple movable sheild has been suggested for controlling temperature of solar furnace. Temperature modulator can be set to have collected solar energy fully "on", fully "off" or any intermediate level. Parabolic mirror concentrates Sunlight into receiver. Shade plate that blocks insolation at back of receiver produces shade zone in center of collector. No radiation is returned to receiver from shade zone; only rays falling on other areas of reflecting surface are directed back toward receiver.

Hale, R. R.↗

Oxygen generation subsystem for spacecraft

Recovery of oxygen from water will be needed on future long-duration manned space missions. An oxygen generation subsystem (OGS) for NASA based on the alkaline electrolyte, static feed water electrolysis concept. Recent advances in hardware development have resulted in the design, fabrication and testing of a self-contained, one-person capacity OGS (WS-1). This subsystem consists of three major parts: a six-cell electrochemical module to generate the product O2, a coolant control assembly to maintain module temperature and a pressure controller which maintains product gas pressures. The subsystem provides 0. 82 kg/d O2 while operating at a current density of 206 mA/ sq cm, a temperature of 339 K and a pressure of 1240 kPa.

Schubert, F. H.↗

Throughput of the Composite Infrared Spectrometer (CIRS) Mid Infrared (MIR) Channel for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The instrument was aligned at ambient temperature, but operates at 170 Kelvin and has challenging interferometric alignment tolerances. Cryogenic alignment tests of the instrument indicate that it should suffer minimal degradation due to the cooldown from ambient to operational temperature. System level tests performed by the calibration team indicated a lower than expected signal level on the MIR channel, while providing ambiguous optical throughput data. Therefore it became imperative to develop a metric that could be used to determine the instrument performance at both the instrument and system levels, at ambient and cryogenic temperature. Modulation efficiency and throughput measurements were performed and new analytical models developed to evaluate the status of the instrument. Empirical and analytical data were eventually reconciled and deviations from the design values explained.

Hagopian, John G.↗

Remote Sensing of Global Wetland Dynamics

Although natural wetlands only cover about 4% of the earth's ice-free land surface, they are the world's largest methane (CH4) source and the only one dominated by climate. In addition, wetlands affect climate by modulating temperatures and heat fluxes, storing water, increasing evaporation, and altering the seasonality of runoff and river discharge to the oceans. Current CH4 emissions from wetlands are relatively well understood but the sensitivity of wetlands and their emissions to climate variations remains the largest uncertainty in the global CH4 cycle and could strongly influence predictions of future climate. Therefore, characterizing climate-sensitive processes prevailing in the world's wetlands is crucial to understanding and predicting physical and biogeochemical responses of wetlands to interannual and longer-term climate variations. Recent research has resulted in the first generation of models to predict methane emissions from wetlands but the models must still be applied to static data on wetland distributions. Moreover, no models currently exist to realistically predict the distribution and dynamics of wetlands themselves for the current, or any other, climate. The dominant obstacle to modeling wetland dynamics has been lack of remote sensing techniques and data useful for characterizing quantitatively the seasonal and interannual variations of wetlands. We report on initial remote sensing studies undertaken to validate a global hydrological model linking rivers, takes and wetlands. Using a combination of SSM/I microwave and TOPEX Poseidon altimetry data sets, we developed and applied techniques to quantify inundation extent and duration for several large wetlands in tropical Africa and South America. Our initial results indicate that seasonally-inundated wetlands can be well characterized over large spatial scales and at monthly time scales using these remote sensing data. The results also confirm that currently available remote sensing products can be applied to provide crucial data to the research community modeling global hydrological and biogeochemical cycles.

Matthews, Elaine↗

Ground Based Remote Sensing of Upper Atmosphere Dynamics, Thermodynamics and Composition in Support of TIMED Satellites Scientific Mission

The following research work was accomplished: 1. We operated high throughput spectrophotometers and interferometers at eight observatories in the Arctic, Antarctic and mid-latitude regions to record relatively high-resolution spectra of very low light level airglow and auroral line as well as band emissions. 2. Our Polar observations of auroral emissions from N2 and O emissions have been analyzed to derive the O/N2 ratios around 110 km height in the Polar thermosphere during different auroral events triggered by the precipitation of auroral electrons with average energy of about 10 keV. These results have been compared with similar ratios derived from TIMED satellite s GUVI measurements of N2 LBH and 01 1356A emissions. 3. Our airglow measurements show MLT density and temperature modulations by Planetary, Tidal and Gravity Waves. They also indicate Mesopause cooling preceding a Stratospheric Warming Event (SWE).

Source record↗

Preliminary 3D Simulations of Anomalous Thermocouple Coupling to Surface Electric Fields

Anomalous measurements from subsurface thermocouples have been observed during re-entry of the Orion capsule (EFT-1 plugs). These measurements are considered anomalous because the amplitude and frequency of the inferred temperature modulations are too large to be due to plausible heating processes. Consequently, it is believed the anomalies are caused by electrical interference generated by the re-entry plasma. Quantifying these effects requires several steps: modeling the external plasma flows, modeling the plasma-surface interaction, and finally modeling the surface-thermocouple coupling. This paper addresses this last step using 3D finite element simulations of a wire embedded in a weakly conductive medium.

thermocouple anomaly↗

RadLab and the Environmental Data Application Dashboard: Graphical and Programming Interfaces for Interrogation of Space Telemetry Data

Sensors on the International Space Station (ISS) and multiple spacecraft elsewhere in Earth orbit and in deep space continuously monitor and collect environmental data, transmitting this information back to Earth. These data include ionizing radiation and, on the ISS, CO2, relative humidity levels, and temperature, and are of great importance to space biology research. Ionizing radiation in particular has been established in ground-based experiments as being correlated with increased risk of carcinogenesis and cardiovascular and neurological effects. Looking ahead to future long duration crewed missions beyond low Earth orbit, the ability to study how factors including CO2 levels, light cycle, temperature modulate the response to ionizing radiation and microgravity is essential. To date, access to these data has been fragmented across space agencies, spacecraft, and databases. To address this issue, NASA’s Open Science Data Repository (osdr.nasa.gov) has developed two Web applications: the Environmental Data Application (EDA) and a radiation-specific RadLab. Each consists of an API (application programming interface) and an associated GUI (graphical user interface) that provide single points of access to the data. To date, OSDR has focused on the sensors from payloads and radiation detectors located on the ISS. The Web applications process telemetry information and associated data, such as spacecraft location and orientation, from multiple international databases. The applications’ request syntax enables users to interrogate these data by craft, sensor type, time range, radiation type (galactic cosmic rays, solar particle events, the contribution of the South Atlantic Anomaly), facilitating arbitrary comparisons of original source data at varying time resolutions. The applications provide programmatic access for use in computational pipelines and GUIs for data visualization and exploration, making these data FAIR (Findable, Accessible, Interoperable, and Reusable), complementing the biological data contained in OSDR, and providing the space science community with a valuable resource for scientific analyses.

radiation↗

PV array simulator development and validation.

The ability to harvest all available energy from a photovoltaic (PV) array is essential if new system developments are to meet levelized cost of energy targets and achieve grid parity with conventional centralized utility power. Therefore, exercising maximum power point tracking (MPPT) algorithms, dynamic irradiance condition operation and startup and shutdown routines and evaluating inverter performance with various PV module fill-factor characteristics must be performed with a repeatable, reliable PV source. Sandia National Laboratories is collaborating with Ametek Programmable Power to develop and demonstrate a multi-port TerraSAS PV array simulator. The simulator will replicate challenging PV module profiles, enabling the evaluation of inverter performance through analyses of the parameters listed above. Energy harvest algorithms have traditionally implemented methods that successfully utilize available energy. However, the quantification of energy capture has always been difficult to conduct, specifically when characterizing the inverter performance under non-reproducible dynamic irradiance conditions. Theoretical models of the MPPT algorithms can simulate capture effectiveness, but full validation requires a DC source with representative field effects. The DC source being developed by Ametek and validated by Sandia is a fully integrated system that can simulate an IV curve from the Solar Advisor Model (SAM) module data base. The PV simulator allows the user to change the fill factor by programming the maximum power point voltage and current parameters and the open circuit voltage and short circuit current. The integrated PV simulator can incorporate captured irradiance and module temperature data files for playback, and scripted profiles can be generated to validate new emerging hardware embedded with existing and evolving MPPT algorithms. Since the simulator has multiple independent outputs, it also has the flexibility to evaluate an inverter with multiple MPPT DC inputs. The flexibility of the PV simulator enables the validation of the inverter's capability to handle vastly different array configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Suggested Modifications for Bifacial Capacity Testing: Preprint

Capacity tests such as those described in ASTM 2848 and IEC 61724-2 are widely used during the contracting and acceptance testing of PV systems. With the increasing deployment of bifacial PV modules, there is a need to develop a standardized approach to capacity test these systems. Although variability and bias error was inherently higher for the measured capacity of bifacial systems, it could be reduced to a level consistent with the monofacial reference system by appropriate incorporation of rear irradiance- either measured or modeled. Three field installations provided bifacial system capacity that was measured with a mean bias error and standard deviation within 1% over the 2-10 month observation period. Capacity test accuracy could be improved further by utilizing measured back-of-module temperature and the IEC 61724-2 test method.

14 SOLAR ENERGY↗

Scanning tunneling thermometer

Various examples are provided related to scanning tunneling thermometers and scanning tunneling microscopy (STM) techniques. In one example, a method includes simultaneously measuring conductance and thermopower of a nanostructure by toggling between: applying a time modulated voltage to a nanostructure disposed on an interconnect structure, the time modulated voltage applied at a probe tip positioned over the nanostructure, while measuring a resulting current at a contact of the interconnect structure; and applying a time modulated temperature signal to the nanostructure at the probe tip, while measuring current through a calibrated thermoresistor in series with the probe tip. In another example, a device includes an interconnect structure with connections to a first reservoir and a second reservoir; and a scanning tunneling probe in contact with a probe reservoir. Electrical measurements are simultaneously obtained for temperature and voltage applied to a nanostructure between the reservoirs.

Chinivaranahalli Shastry, Abhay Shankar↗

Scanning tunneling thermometer

Various examples are provided related to scanning tunneling thermometers and scanning tunneling microscopy (STM) techniques. In one example, a method includes simultaneously measuring conductance and thermopower of a nanostructure by toggling between: applying a time modulated voltage to a nanostructure disposed on an interconnect structure, the time modulated voltage applied at a probe tip positioned over the nanostructure, while measuring a resulting current at a contact of the interconnect structure; and applying a time modulated temperature signal to the nanostructure at the probe tip, while measuring current through a calibrated thermoresistor in series with the probe tip. In another example, a device includes an interconnect structure with connections to a first reservoir and a second reservoir; and a scanning tunneling probe in contact with a probe reservoir. Electrical measurements are simultaneously obtained for temperature and voltage applied to a nanostructure between the reservoirs.

Chinivaranahalli Shastry, Abhay Shankar↗