Search NASA⌕ Search

SEARCH · Search NASA

Results for “molecular diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Bioscience COVID Rapid Response Report

The COVID-19 disease outbreak and its impact on global health and economies have highlighted the national security threat posed by pathogens with pandemic potential and the need for rapid development of effective diagnostics and medical countermeasures. The Bioscience IA selected for funding rapid COVID LDRD project proposals that addressed critical R&D gaps in pandemic response that could be accomplished in 1-3 months with the requested funding. In total, the Bioscience IA funded nine rapid projects that addressed 1) rapid and accurate methods for SARS-CoV-2 RNA detection, 2) modeling tools to help prioritize populations for diagnostic testing, 3) bioinformatic tools to track SARS-CoV-2 genomic sequence changes over time, 4) molecular inhibitors of SARS-CoV-2 cellular infection, and 5) method for rapid staging of COVID19 disease to enable administration of more effective treatments. In addition, LDRD funded one larger project to be completed in FY21 that leverages Sandia capabilities to address the need for platform diagnostics and therapeutics that can be rapidly tailored against emerging pathogen targets.

59 BASIC BIOLOGICAL SCIENCES↗

Lipid biomarkers for bacterial ecosystems: studies of cultured organisms, hydrothermal environments and ancient sediments

This paper forms part of our long-term goal of using molecular structure and carbon isotopic signals preserved as hydrocarbons in ancient sediments to improve understanding of the early evolution of Earth's surface environment. We are particularly concerned with biomarkers which are informative about aerobiosis. Here, we combine bacterial biochemistry with the organic geochemistry of contemporary and ancient hydrothermal ecosystems to construct models for the nature, behaviour and preservation potential of primitive microbial communities. We use a combined molecular and isotopic approach to characterize lipids produced by cultured bacteria and test a variety of culture conditions which affect their biosynthesis. This information is then compared with lipid mixtures isolated from contemporary hot springs and evaluated for the kinds of chemical change that would accompany burial and incorporation into the sedimentary record. In this study we have shown that growth temperature does not appear to alter isotopic fractionation within the lipid classes produced by a methanotropic bacterium. We also found that cultured cyanobacteria biosynthesize diagnostic methylalkanes and dimethylalkanes with the latter only made when growing under low pCO2. In an examination of a microbial mat sample from Octopus Spring, Yellowstone National Park (USA), we could readily identify chemical structures with 13C contents which were diagnostic for the phototrophic organisms such as cyanobacteria and Chloroflexus. We could not, however, find molecular evidence for operation of a methane cycle in the particular mat samples we studied.

NASA Discipline Exobiology↗

Optical depth of molecular gas in starburst galaxies - Is M82 the prototype?

An attempt is made to survey the CO(2-1) emission toward the centers of 17 IR-luminous galaxies which have previously been detected in CO(1-0). These galaxies span a wide range of size and L(FIR)/L(B) ratio, many have multiple-wavelength studies establishing them as starbursts, and some bear a morphological resemblance to M 82. Nine galaxies are detected and useful upper limits are placed on the remaining eight. Using the CO(2-1)/CO(1-0) ratio of antenna temperature as a diagnostic of optical depth, it is found that all of the galaxies contain predominantly optically thick molecular gas. This implies that the phase of starburst during which the molecular gas is optically thin, currently witnessed in M 82, is either uncommon or short-lived.

Verter, F.↗

Quantifying Stern layer water alignment before and during the oxygen evolution reaction

While water’s oxygen is the electron source in the industrially important oxygen evolution reaction, the strong absorber problem clouds our view of how the Stern layer water molecules orient themselves in response to applied potentials. Here, we report nonlinear optical measurements on nickel electrodes held at pH 13 indicating a disorder-to-order transition in the Stern layer water molecules before the onset of Faradaic current. A full water monolayer (1.1 × 10 15 centimeter −2 ) aligns with oxygen atoms pointing toward the electrode at +0.8 volt and the associated work is 80 kilojoule per mole. Our experiments identify water flipping energetics as a target for understanding overpotentials, advance molecular electrochemistry, provide benchmarks for electrical double layer models, and serve as a diagnostic tool for understanding electrocatalysis.

Science & Technology - Other Topics↗

Evaluation of sterol-o-acyl transferase 1 and cholesterol ester levels in plasma, peritoneal fluid and tumor tissue of patients with endometrial cancer: A pilot study

Endometrial cancer (EC) is the most prevalent gynecological malignancy. Abnormal accumulation of sterol-O-acyl transferase 1 (SOAT1) and SOAT1-mediated cholesterol ester (CE) contributes to cancer progression in various malignancies, including ovarian cancer. Therefore, it was hypothesized that similar molecular changes may occur in EC. The present study aimed to evaluate the diagnostic and/or prognostic potential of SOAT1 and CE in EC by: i) Determining SOAT1 and CE levels in plasma, peritoneal fluid and endometrial tissue from patients with EC and control subjects; ii) performing receiver operating characteristic curve analysis to determine diagnostic performance; iii) comparing SOAT1 and CE expression to that of the tumor proliferation marker Ki67; and iv) assessing the association between SOAT1 expression and survival. Enzyme-linked immunosorbent assay was used to determine the levels of SOAT1 protein in tissue, plasma and peritoneal fluid. The mRNA and protein expression levels of SOAT1 and Ki67 in tissues were detected by reverse transcription-quantitative polymerase chain reaction and immunohistochemistry, respectively. CE levels were determined colorimetrically in plasma and peritoneal fluid. SOAT1-associated survival data from the cBioPortal cancer genomics database were used to assess prognostic relevance. The results revealed that SOAT1 and CE levels were significantly elevated in tumor tissue and peritoneal fluid samples collected from the EC group. By contrast, the plasma levels of SOAT1 and CE in the EC and control groups were similar. Significant positive associations between CE and SOAT1, SOAT1/CE and Ki67, and SOAT1/CE and poor overall survival in patients with EC suggested that SOAT1/CE may be associated with malignancy, aggressiveness and poor prognosis. In conclusion, SOAT1 and CE may serve as potential biomarkers for prognosis and target-specific treatment of EC.

59 BASIC BIOLOGICAL SCIENCES↗

A diagnostic for determining the quality of single-reference electron correlation methods

It was recently proposed that the Euclidian norm of the t(sub 1) vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appopriate. This diagnostic, T(sub 1) is defined for use with self-consistent-field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T(sub 1) is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of non-dynamical electron correlation and is far superior to C(sub 0) from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T(sub 1) (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.

Lee, Timothy J.↗

Grain Spectroscopy

Our fundamental knowledge of interstellar grain composition has grown substantially during the past two decades thanks to significant advances in two areas: astronomical infrared spectroscopy and laboratory astrophysics. The opening of the mid-infrared, the spectral range from 4000-400 cm(sup -1) (2.5-25 microns), to spectroscopic study has been critical to this progress because spectroscopy in this region reveals more about a materials molecular composition and structure than any other physical property. Infrared spectra which are diagnostic of interstellar grain composition fall into two categories: absorption spectra of the dense and diffuse interstellar media, and emission spectra from UV-Vis rich dusty regions. The former will be presented in some detail, with the latter only very briefly mentioned. This paper summarized what we have learned from these spectra and presents 'doorway' references into the literature. Detailed reviews of many aspects of interstellar dust are given.

Allamandola, L. J.↗

Rocket-Plume Spectroscopy Simulation for Hydrocarbon-Fueled Rocket Engines

The UV-Vis spectroscopic system for plume diagnostics monitors rocket engine health by using several analytical tools developed at Stennis Space Center (SSC), including the rocket plume spectroscopy simulation code (RPSSC), to identify and quantify the alloys from the metallic elements observed in engine plumes. Because the hydrocarbon-fueled rocket engine is likely to contain C2, CO, CH, CN, and NO in addition to OH and H2O, the relevant electronic bands of these molecules in the spectral range of 300 to 850 nm in the RPSSC have been included. SSC incorporated several enhancements and modifications to the original line-by-line spectral simulation computer program implemented for plume spectral data analysis and quantification in 1994. These changes made the program applicable to the Space Shuttle Main Engine (SSME) and the Diagnostic Testbed Facility Thruster (DTFT) exhaust plume spectral data. Modifications included updating the molecular and spectral parameters for OH, adding spectral parameter input files optimized for the 10 elements of interest in the spectral range from 320 to 430 nm and linking the output to graphing and analysis packages. Additionally, the ability to handle the non-uniform wavelength interval at which the spectral computations are made was added. This allowed a precise superposition of wavelengths at which the spectral measurements have been made with the wavelengths at which the spectral computations are done by using the line-by-line (LBL) code. To account for hydrocarbon combustion products in the plume, which might interfere with detection and quantification of metallic elements in the spectral region of 300 to 850 nm, the spectroscopic code has been enhanced to include the carbon-based combustion species of C2, CO, and CH. In addition, CN and NO have spectral bands in 300 to 850 nm and, while these molecules are not direct products of hydrocarbon-oxygen combustion systems, they can show up if nitrogen or a nitrogen compound is present as an impurity in the propellants and/or these can form in the boundary layer as a result of interaction of the hot plume with the atmosphere during the ground testing of engines. Ten additional electronic band systems of these five molecules have been included into the code. A comprehensive literature search was conducted to obtain the most accurate values for the molecular and the spectral parameters, including Franck-Cordon factors and electronic transition moments for all ten band systems. For each elemental transition in the RPSSC, six spectral parameters - Doppler broadened line width at half-height, pressure-broadened line width at half-height, electronic multiplicity of the upper state, electronic term energy of the upper state, Einstein transition probability coefficient, and the atomic line center - are required. Input files have been created for ten elements of Ni, Fe, Cr, Co, Cu, Ca, Mn, Al, Ag, and Pd, which retain only relatively moderate to strong transitions in 300 to 430 nm spectral range for each element. The number of transitions in the input files is 68 for Ni; 148 for Fe; 6 for Cr; 87 for Co; 1 for Ca; 3 for Mn; 2 each for Cu, Al, and Ag; and 11 for Pd.

Tejwani, Gopal D.↗

Biomolecule Sequencer: Next-Generation DNA Sequencing Technology for In-Flight Environmental Monitoring, Research, and Beyond

On the International Space Station (ISS), technologies capable of rapid microbial identification and disease diagnostics are not currently available. NASA still relies upon sample return for comprehensive, molecular-based sample characterization. Next-generation DNA sequencing is a powerful approach for identifying microorganisms in air, water, and surfaces onboard spacecraft. The Biomolecule Sequencer payload, manifested to SpaceX-9 and scheduled on the Increment 4748 research plan (June 2016), will assess the functionality of a commercially-available next-generation DNA sequencer in the microgravity environment of ISS. The MinION device from Oxford Nanopore Technologies (Oxford, UK) measures picoamp changes in electrical current dependent on nucleotide sequences of the DNA strand migrating through nanopores in the system. The hardware is exceptionally small (9.5 x 3.2 x 1.6 cm), lightweight (120 grams), and powered only by a USB connection. For the ISS technology demonstration, the Biomolecule Sequencer will be powered by a Microsoft Surface Pro3. Ground-prepared samples containing lambda bacteriophage, Escherichia coli, and mouse genomic DNA, will be launched and stored frozen on the ISS until experiment initiation. Immediately prior to sequencing, a crew member will collect and thaw frozen DNA samples, connect the sequencer to the Surface Pro3, inject thawed samples into a MinION flow cell, and initiate sequencing. At the completion of the sequencing run, data will be downlinked for ground analysis. Identical, synchronous ground controls will be used for data comparisons to determine sequencer functionality, run-time sequence, current dynamics, and overall accuracy. We will present our latest results from the ISS flight experiment the first time DNA has ever been sequenced in space and discuss the many potential applications of the Biomolecule Sequencer for environmental monitoring, medical diagnostics, higher fidelity and more adaptable Space Biology Human Research Program investigations, and even life detection experiments for astrobiology missions.

Sequencer↗

Quantitative Gas Property Measurements By Filtered Rayleigh Scattering: A Review

Filtered Rayleigh scattering (FRS) is a laser-based diagnostic technique used to nonintrusively quantify various thermodynamic properties of a light-scattering gas. The backbone of FRS is the molecular filtering of Rayleigh scattered light. This concept was initially introduced by the atmospheric LIDAR community before being adopted within the aerospace research field in the early 1990s. Since then, FRS has matured into a versatile quantitative diagnostic tool and has found use in a variety of flow regimes ranging from sub- to supersonic speeds in both reacting and nonreacting environments. This adoption can be attributed to the wealth of information that can be obtained via FRS, including the gas density, pressure, temperature, velocity, species composition, or, in some cases, several of these properties at once. This article reviews the current state of FRS methodology in recovering such gas properties. As knowledge of the fundamentals of Rayleigh scattering and spectral light filtering is crucial to the design of an FRS experiment, we begin by briefly reviewing these areas. Subsequently, we conduct a survey of experimental design strategies, assumptions, and data reduction methods used to measure different gas properties using FRS. We conclude the review with a short discussion on quantification of experimental uncertainty and future trends in FRS.

filtered Rayleigh scattering↗

Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: An Investigation of the Metal Catalyst by Laser Ablation Atomic Fluorescence Spectroscopy

Carbon nanotubes, elongated molecular tubes with diameters of nanometers and lengths in microns, hold great promise for material science. Hopes for super strong light-weight material to be used in spacecraft design is the driving force behind nanotube work at JSC. The molecular nature of these materials requires the appropriate tools for investigation of their structure, properties, and formation. The mechanism of nanotube formation is of particular interest because it may hold keys to controlling the formation of different types of nanotubes and allow them to be produced in much greater quantities at less cost than is currently available. This summer's work involved the interpretation of data taken last summer and analyzed over the academic year. The work involved diagnostic studies of carbon nanotube formation processes occurring in a laser-produced plume. Laser ablation of metal doped graphite to produce a plasma plume in which carbon nanotubes self assemble is one method of making carbon nanotube. The laser ablation method is amenable to applying the techniques of laser spectroscopy, a powerful tool for probing the energies and dynamics of atomic and molecular species. The experimental work performed last summer involved probing one of the metal catalysts, nickel, by laser induced fluorescence. The nickel atom was studied as a function of oven temperature, probe laser wavelength, time after ablation, and position in the laser produced plume. This data along with previously obtained data on carbon was analyzed over the academic year. Interpretations of the data were developed this summer along with discussions of future work. The temperature of the oven in which the target is ablated greatly influences the amount of material ablated and the propagation of the plume. The ablation conditions and the time scale of atomic and molecular lifetimes suggest that initial ablation of the metal doped carbon target results in atomic and small molecular species. The metal atoms survive for several milliseconds while the gaseous carbon atoms and small molecules nucleate more rapidly. Additional experiments and the development of in situ methods for carbon nanotube detection would allow these results to be interpreted from the perspective of carbon nanotube formation.

deBoer, Gary↗

Infrared fine-structure line diagnostics of shrouded active galactic nuclei

The ultraluminous far-IR galaxies revealed by IRAS, quasar-like in luminosity but smothered in molecular gas, probably conceal either immense starbursts or luminous active nuclei. In both scenarios, these objects ought to produce copious infrared fine-structure emission with several lines comparable to H-beta in luminosity. We show how these lines, if detected, can be used to determine the electron densities and far-IR obscurations of shrouded photoionized regions and to constrain the shape and ionization parameter of the ionizing spectra. The presence of Ne v emission in particular will distinguish shrouded AGNs from shrouded starbursts. Since all active galaxies photoionize at least some surrounding material, these diagnostics can also be applied to active galaxies in general and will aid in studying how an active nucleus interacts with the interstellar medium of its host galaxy.

Voit, G. M.↗

A model for the infrared emission from an OB star cluster environment

Researchers developed an interactive radiative transfer code that predicts the infrared emission from an HII region containing diffuse ionized and atomic gas and dense molecular clouds. This model complements the investigation of the redistribution of OB star luminosity in the interstellar medium (Leisawitz and Hauser 1988, Ap. J., 332, 954). The model can be used as a diagnostic tool to probe the radiation field and matter density in an HII region, place constraints on the proximity and orientation of an illuminated molecular cloud with respect to the ionizing stars, test for the presence of small, transiently heated dust grains, and determine whether the dust-to-gas ratio is normal. Predictions of the model agree qualitatively and quantitatively with observations of blister-type HII regions ionized by well-studied OB clusters in which the distribution of dense neutral material is known. This is illustrated by a model for Infrared Astronomy Satellite (IRAS) observations of the region around NGC 7380 (S142). Researchers plan to use the model in a survey of regions of massive star formation in the outer Galaxy to study OB stars embedded to various degrees in their parental molecular clouds.

Leisawitz, D.↗

An Activity-Based Sensing Approach to Monitor Nanomaterial-Promoted Changes in Labile Metal Pools in Living Systems

Metal-based nanoparticles are a promising class of materials for diagnosis and treatment of cancer and other diseases. However, mechanisms of action of these nanomedicines remain insufficiently understood due in large part to our limited understanding of the dynamic equilibria between solid metal nanoparticles and labile metal ions generated from these nanoparticles within complex biological milieus. Here, we apply activitybased sensing to directly identify and investigate the fate of labile copper pools with metal and oxidation state-specificity generated by anticancer copper nanomedicines. We found that treatment of cells with copper-releasing nanoparticles alter labile Cu(I)/Cu(II) ratios through an increase in labile Cu(II), while overall labile copper levels decrease. Labile copper release triggers compensatory responses in two major antioxidant pathways, glutathione (GSH) and nuclear factor erythroid 2-related factor 2 (NRF2), as well as in metal homeostasis to limit copper availability via regulation of copper export (ATP7B) and copper import (CTR1) proteins. These findings establish the value of activity-based sensing as a generalizable approach for labile metal imaging to help decipher molecular mechanisms of bioactive metal nanoparticles and guide the development of more effective nanomedicine diagnostics and therapies to target metal-dependent disease vulnerabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimates of global recycling coefficients for LTX- β discharges

We report the first observation of global recycling coefficient R near 0.5 in the Lithium Tokamak eXperiment-β (LTX-β), significantly below the minimum R previously reported in other devices. In a series of experiments with varied Li wall conditioning, estimates of the recycling coefficient have been made using a Lyman-α array and DEGAS2 modeling. A progressive reduction in Lyman-α emission with increased lithium and an increase in edge electron temperature are observed. It is also observed that with increasing Li coating thickness, the effective particle confinement time τp* is reduced and approaches TRANSP calculated energy confinement time (τE), with τp* near τE,TRANSP for the lowest recycling coefficients. Edge temperatures approaching core plasma temperatures, first reported in LTX, can now be directly connected to estimates of the recycling coefficient and qualitatively agree with previous UEDGE simulations. The particle flux to the limiting surfaces appears to be significantly reduced in comparison with fluid scrape-off layer (SOL) models, indicating that a large fraction of the SOL ions are mirror trapped. SOL collisionality drops more than an order of magnitude below the banana regime boundary, indicating the importance of kinetic effects. Full-f 1x2v gyrokinetic simulations of SOL field lines with the GKEYLL code indicate that the fraction of ions trapped along field lines increases as collisionality drops, as a result of increased lithium evaporation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron beam diagnostics.

Spectroscopic electron beam diagnostic technique, examining negligible effect elevated vibrational temperatures have on measured rotational temperatures of molecular nitrogen

ELECTRON BEAM↗