Spaceflight KID Readout Electronics Development for PRIMA

We present the design and testing of spaceflight multiplexing kinetic inductance detector (KID) readout electronics for the PRobe far-Infrared Mission for Astrophysics (PRIMA). PRIMA is a mission proposed to the 2023 NASA Astrophysics Probe Explorer (APEX) Announcement of Opportunity that will answer fundamental questions about the formation of planetary systems, as well as the formation and evolution of stars, supermassive black holes, and dust over cosmic time. The readout electronics for PRIMA must be compatible with operation at Earth-Sun L2 and capable of multiplexing more than 1000 detectors over 2 GHz bandwidth while consuming around 30 W per readout chain. The electronics must also be capable of switching between the two instruments, which have different readout bands,: the hyperspectral imager (PRIMAger, 2.5-5.0 GHz) and the spectrometer (FIRESS, 0.4-2.4 GHz). We present the driving requirements, design, and measured performance of a laboratory brassboard system.

Sumit Dahal↗

Fine Optimization of TES Design for the X-IFU Instrument on ATHENA

The X-ray Integral Field Unit (X-IFU) instrument on the Advanced Telescope for High ENergy Astrophysics (ATHENA) is baselined to have 3168 transition-edge sensor (TES) microcalorimeter pixels. These pixels will be DC biased and readout using time division multiplexing. We recently reported a demonstration of the required pixel and readout performance in 252 pixels from a 1 kilo-pixel array (e.g. 2.16 eV resolution for 6.9 keV X-rays). Having achieved the required performance, the 50um square TES design in this demonstration array is considered the baseline pixel design for X-IFU. However, by making small adjustments to the TES design, we may be able to make small but consequential improvements to the instrument performance, while staying within the many constraints of the X-IFU requirements. In this presentation, we will show results from newly fabricated devices with subtle changes from the baseline TES design to further optimize the performance for X-IFU. We will discuss optimizing the TES sheet resistance, normal metal features, X-ray absorber attachment points, TES aspect ratio, and heat capacity. These minor design changes can have significant effects on thermo-electric time constants, thermal fluctuation noise, resistive transition shape and uniformity, and non-linearity of X-ray event pulses. In addition, full characterization of these new TES designs allows greater understanding of the relevant physics within the TES and gives routes for further optimization.

Nick Wakeham↗

Three-Wave Mixing Kinetic Inductance Traveling-Wave Amplifier with Near-Quantum-Limited Noise Performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices. It consists of a 50 Ω artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{–1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of –63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier. This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

42 ENGINEERING↗

The EBEX Balloon-borne Experiment—Gondola, Attitude Control, and Control Software

The E and B Experiment (EBEX) was a long-duration balloon-borne instrument created to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilopixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant-velocity azimuthal scans. We report on the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented, including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilopixel array, and specialized attitude reconstruction software. We demonstrate flight performance data reflecting faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of the CMB B-mode power spectrum with r = 0.05.

polarization↗

Developing Low-Noise GaAs JFETs For Cryogenic Operation

Report discusses aspects of effort to develop low-noise, low-gate-leakage gallium arsenide-based junction field-effect transistors (JFETs) for operation at temperature of about 4 K as readout amplifiers and multiplexing devices for infrared-imaging devices. Transistors needed to replace silicon transistors, relatively noisy at 4 K. Report briefly discusses basic physical principles of JFETs and describes continuing process of optimization of designs of GaAs JFETs for cryogenic operation.

Cunningham, Thomas J.↗

Dual Common Planes for Time Multiplexing of Dual-Color QWIPs

A proposed improved method of externally controlled time multiplexing of the readouts of focal-plane arrays of pairs of stacked quantum-well infrared photodetectors (QWIPs) that operate in different wavelength bands is based on a dual-detector-common-plane circuit configuration. The method would be implemented in a QWIP integrated-circuit chip hybridized with a readout integrated-circuit (ROIC) chip.

Rafol, Sir B.↗

Analog bus driver and multiplexer

For a source-follower signal chain, the ohmic drop in the selection switch causes unacceptable voltage offset, non-linearity, and reduced small signal gain. For an op amp signal chain, the required bias current and the output noise rises rapidly with increasing the array format due to a rapid increase in the effective capacitance caused by the Miller effect boosting up the contribution of the bus capacitance. A new switched source-follower signal chain circuit overcomes limitations of existing op-amp based or source follower based circuits used in column multiplexers and data readout. This will improve performance of CMOS imagers, and focal plane read-out integrated circuits for detectors of infrared or ultraviolet light.

Pain, Bedabrata↗

Crosstalk in microwave SQUID multiplexers

Low-temperature detector technologies provide extraordinary sensitivity for applications ranging from precision measurements of the cosmic microwave background to high-resolution, high-rate x-ray, and γ-ray spectroscopy. To utilize this sensitivity, new instruments are being built, and new instruments are imagined, with ever greater pixel counts, but the scale of these instruments is limited by the capability of the readout electronics. Microwave SQUID multiplexing addresses the needs of these future instruments, exploiting gigahertz of bandwidths of coaxial cables and broadband components to combine hundreds to thousands of signals on a single readout line. A key feature of any multiplexer is the level of crosstalk between input channels. This crosstalk can degrade the sensitivity of the instrument, introduce systematic error, or simply confound data analysis. In this letter, we explain the primary mechanisms of crosstalk in a microwave SQUID multiplexer, calculate and measure their magnitude, and consider their effect and methods of mitigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

End-to-End Modeling of the TDM Readout System for CMB-S4

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the cosmic microwave background with unprecedented sensitivity. This will require an order of magnitude increase in the 100-mK detector count, which, in turn, increases the demands on the readout system. The CMB-S4 readout will use time-division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuitry and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. Here, we present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.

47 OTHER INSTRUMENTATION↗

TES-Based X-Ray Microcalorimeter Performances Under AC Bias and FDM for Athena

Athena is a European X-ray observatory, scheduled for launch in 2028. Athena will employ a high-resolution imaging spectrometer called X-ray integral field unit (X-IFU), consisting of an array of 4000 transition edge sensor (TES) microcalorimeter pixels. For the readout of X-IFU, we are developing frequency domain multiplexing, which is the baseline readout system. In this paper, we report on the performance of a TES X-ray calorimeter array fabricated at Goddard Space Flight Center (GSFC) at MHz frequencies for the baseline of X-IFU detector. During single-pixel AC bias characterization, we measured X-ray energy resolutions (at 6 keV) of about 2.9 eV at both 2.3 and 3.7 MHz. Furthermore, in the multiplexing mode, we measured X-ray energy resolutions of about 2.9 eV at 1.3 and 1.7 MHz.

Transition edge sensors X-ray microcalorimeter Fre↗

Superconducting THz Camera with GaAs‐JFET Cryogenic Readout Electronics

We describe the development of large format array of superconducting tunnel junction detectors that is readout by SONY GaAs‐JFET cryogenic integrated circuits. High quality SIS photon detectors have high dynamic impedance that can be readout by low gate leakage GaAs‐JFET circuits. Our imaging array design, with niobium SIS photon detectors and GaAs‐JFET cryogenics electronics, uses integrating amplifiers, multiplexers and shift‐registers to readout large number of pixels that is similar to CMOS digital cameras. We have designed and fabricated GaAs‐JFET cryogenic integrated circuits, such as AC‐coupled capacitive trans‐impedance amplifier, multiplexers with sample‐and‐holds and shift‐registers, for 32‐channel readout module. The Advanced Technology Center of National Astronomical Observatory of Japan have started extensive development program for large format array of SIS photon detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background(CMB)science depend on increasing the number of sensitive detectorsobserving the sky. New instruments deploy large arrays of superconducting transition-edge sensor(TES)bolometers tileddensely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers andsimplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexingfactor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, whichemploys microwave SQUID multiplexing(μmux). Simons Observatory will use 49 modules containing 70,000bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design,presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor.The median white noise of each readout channel is 65pA Hz. This impacts the projected SO mapping speed by<8%,which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. Wediscuss the measured performance in the context of SO science requirements, which are exceeded.

Heather McCarrick↗

The EBEX Balloon-borne Experiment—Detectors and Readout

EBEX was a long-duration balloon-borne experiment to measure the polarization of the cosmic microwave background. The experiment had three frequency bands centered at 150, 250, and 410 GHz and was the first to use a kilopixel array of transition edge sensor bolometers aboard a balloon platform. We determine the design and characterization of the array and the readout system. From the lowest to highest frequency, the median measured detectors' average thermal conductances were 39, 53, and 63 pW/K, the medians of transition temperatures were 0.45, 0.48, and 0.47 K, and the medians of normal resistances were 1.9, 1.5, and 1.4 Ω; moreover, we give the measured distributions. With the exception of the thermal conductance at 150 GHz, all measured values are within 30% of their design. We measure median low-loop-gain time constants τ 0 = 88, 46, and 57 ms. Two measurements of bolometer absorption efficiency gave results consistent within 10% and showing high (~0.9) efficiency at 150 GHz and medium (~0.35 and ~0.25) efficiency at the two higher bands. We calculate a median total optical power absorbed of 3.6, 5.3, and 5.0 pW. EBEX pioneered the use of the digital version of the frequency domain multiplexing system. We multiplexed the bias and readout of 16 bolometers onto two wires. The median per-detector noise-equivalent temperatures are 400, 920, and 14,500 $\mu {{\rm{K}}}_{{\rm{cmb}}}\sqrt{{\rm{s}}}$. We compare these values to our preflight predictions and to a previous balloon payload. We report on the sources of excess noise and the path for a future payload to make full use of the balloon environment.

instrumentation: polarimeters↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

Experimental advances with the QICK (Quantum Instrumentation Control Kit) for superconducting quantum hardware

The Quantum Instrumentation Control Kit (QICK) is a standalone open-source qubit controller that was first introduced in 2022. In this follow-up work, we present recent upgrades to the QICK and the experimental use cases they uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, predistorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fidelity parametric entangling gates. We explain in detail how the QICK was used to enable these experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HYMOSS signal processing for pushbroom spectral imaging

The objective of the Pushbroom Spectral Imaging Program was to develop on-focal plane electronics which compensate for detector array non-uniformities. The approach taken was to implement a simple two point calibration algorithm on focal plane which allows for offset and linear gain correction. The key on focal plane features which made this technique feasible was the use of a high quality transimpedance amplifier (TIA) and an analog-to-digital converter for each detector channel. Gain compensation is accomplished by varying the feedback capacitance of the integrate and dump TIA. Offset correction is performed by storing offsets in a special on focal plane offset register and digitally subtracting the offsets from the readout data during the multiplexing operation. A custom integrated circuit was designed, fabricated, and tested on this program which proved that nonuniformity compensated, analog-to-digital converting circuits may be used to read out infrared detectors. Irvine Sensors Corporation (ISC) successfully demonstrated the following innovative on-focal-plane functions that allow for correction of detector non-uniformities. Most of the circuit functions demonstrated on this program are finding their way onto future IC's because of their impact on reduced downstream processing, increased focal plane performance, simplified focal plane control, reduced number of dewar connections, as well as the noise immunity of a digital interface dewar. The potential commercial applications for this integrated circuit are primarily in imaging systems. These imaging systems may be used for: security monitoring systems, manufacturing process monitoring, robotics, and for spectral imaging when used in analytical instrumentation.

Ludwig, David E.↗