Search NASA⌕ Search

SEARCH · Search NASA

Results for “non-inductive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impact of lithium wall conditioning and wave-frequency on high density lower hybrid current drive experiment on EAST

A series of dedicated lower hybrid current drive (LHCD) experiments on EAST shows that lithium wall conditioning extends LH current drive and heating up to the line-averaged density of n ̅_e≈ 4x1019 m-3 for both 2.45 and 4.6 GHz. Current drive at such a high density is crucial for the development of long-pulse non-inductive scenarios on EAST. With lithiation, the LH power injection of 1.5 MW at 2.45 GHz resulted in a drop of loop voltage of ~ 0.3 V, which is a comparable loop voltage drop observed with 1.1 MW at 4.6 GHz. The observed decrease in loop voltage is attributed mostly to the RF heating effect. Another LHCD experiment suggests that lithium wall coating has a more significant impact on the scrape-off-layer (SOL) properties than changes in the Greenwald fraction. LHCD at 2.45 GHz still suffers from a loss of efficiency. Enhanced power ionization in front of the launcher may cause the onset of density-dependent wave instabilities. The rise in the midplane SOL density may also accelerate a transition in the divertor regime, leading to additional ionization and collisional losses in the X-point divertor plasma. Ray-tracing modeling supports that a lower wave frequency is more prone to collisional power loss. The experiments confirm that lithiation is a useful tool to control the SOL plasma, and suggest that density control in front of the launcher may be critical to mitigating power loss mechanisms in the plasma boundary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of Thunderstorm Anvil Ice Contents and Other Cloud Properties from Satellite Observations of Lightning

The lightning frequency model developed by Baker, Christian and Latham (1995) has been refined and extended, in an effort to provide a more realistic framework from which to examine computationally the relationships that might exist between lightning frequency f (which is now being routinely measured from satellites, using NASA/MSFC devices) and a variety of cloud physical parameters, including precipitation rate, updraught speed and non-precipitating ice content. The charging mechanism incorporated into the model is the non-inductive ice-ice mechanism - involving rebounding collisions between ice crystals and growing graupel pellets - which has achieved significant field, laboratory and modelling support in recent years. Model results indicate the existence of a simple relationship between lightning frequency f and the upward flux of ice crystals into the thunderstorm anvil. It follows that, for a particular situation, one can assign a specific mass of non-precipitating ice to an individual lightning stroke. Therefore it is possible - using satellite measurements of global lightning - to estimate the atmospheric loading of ice crystals in thunderstorm anvils: a parameter of climatological importance. One can also estimate the ice crystal loading associated with more localized storm systems. Early results from this work will be presented, together with further work on the relationships between f and other thundercloud parameters.

Blyth, Alan M.↗

Static and Switching Characteristics of a 4H-SiC Based BJT to 200 C

Static curves and resistive load switching characteristics of a 600 V, 4 A rated, SiC-based NPN bipolar power transistor (BJT) were observed at selected temperatures from 23 to 200 C. All testing was done in a pulse mode at low duty cycle (approx. 0.1 percent). Turn-on was driven by an adjustable base current pulse and turn-off was accelerated by a negative base voltage pulse of either 7 or 0.6 V. Switching observations were done at base drive currents (I(sub B)) up to 400 mA and collector currents (I(sub C)) up to 4 A, using a 100 OMEGA non-inductive load. At I(sub B) = 400 mA and I(sub C) = 4 A, turn-on times typically varied from 81 to 97 ns, over temperatures from 23 to 200 C. As expected, lowering the base drive greatly extended the turn-on time. Similarly, decreasing the load current to I(sub C) = 1 A with I(sub B) = 400 mA produced turn-on times as short as 30 ns. Over the 23 to 200 C range, with I(sub B) = 400 mA and I(sub C) = 4 A, turn-off times were in the range of 61 to 77 ns with the 7 V sweep-out and 130 to 150 ns with the 0.6 V sweep-out. At a fixed temperature and I(sub C), the turn-off time decreased slightly with decreasing I(sub B), for I(sub B) sufficient to still provide full turn-on. The ratio of conduction to switching losses is estimated, based on the observed I(sub C) transition times and static curves. An estimate at 200 kHz and a 50 percent duty cycle shows that under practicable conditions the two losses can be comparable. Hence the evidence obtained does not support the occasionally voiced concern of necessarily unacceptably high conduction losses in SiC-based BJTs.

Niedra, Janis M.↗

Switching Characteristics of a 4H-SiC Based Bipolar Junction Transistor to 200 C

Static curves and resistive load switching characteristics of a 600 V, 4 A rated, SiC-based NPN bipolar power transistor (BJT) were observed at selected temperatures from room to 200 C. All testing was done in a pulse mode at low duty cycle (approx.0.1 percent). Turn-on was driven by an adjustable base current pulse and turn-off was accelerated by a negative base voltage pulse of 7 V. These base drive signals were implemented by 850 V, gated power pulsers, having rise-times of roughly 10 ns, or less. Base charge sweep-out with a 7 V negative pulse did not produce the large reverse base current pulse seen in a comparably rated Si-based BJT. This may be due to a very low charge storage time. The decay of the collector current was more linear than its exponential-like rise. Switching observations were done at base drive currents (I(sub B)) up to 400 mA and collector currents (I(sub C)) up to 4 A, using a 100 Omega non-inductive load. At I(sub B) = 400 mA and I(sub C) = 4 A, turn-on times typically varied from 80 to 94 ns, over temperatures from 23 to 200 C. As expected, lowering the base drive greatly extended the turn-on time. Similarly, decreasing the load current to I(sub C) = 1 A with I(sub B) = 400 mA produced turn-on times as short as 34 ns. Over the 23 to 200 C range, with I(sub B) = 400 mA and I(sub C) = 4 A, turn-off times were in the range of 72 to 84 ns with the 7 V sweep-out.

Niedra, Janis M.↗

Observed Enhancement of Reflectivity and Electric Field in Long-Lived Florida Anvils

A study of two long-lived Florida anvils showed that reflectivity >20 dBZ increased in area, thickness and sometimes magnitude at mid-level well downstream of the convective cores. In these same regions electric fields maintained strengths >10 kV m1 for many tens of minutes and became quite uniform over tens of kilometers. Millimetric aggregates persisted at 9 to 10 km for extended times and distances. Aggregation of ice particles enhanced by strong electric fields might have contributed to reflectivity growth in the early anvil, but is unlikely to explain observations further out in the anvil. The enhanced reflectivity and existence of small, medium and large ice particles far out into the anvil suggest that an updraft was acting, perhaps in weak convective cells formed by instability generated from the evaporation and melting of falling ice particles. We conclude that charge separation must have occurred in these anvils, perhaps at the melting level but also at higher altitudes, in order to maintain fields >10 kV m 1 at 9 to 10 km for extended periods of time over large distances. We speculate that charge separation occurred as a result of ice-ice particle collisions (without supercooled water being present) via either a non-inductive or perhaps even an inductive mechanism, given the observed broad ice particle spectra, the strong pre-existing electric fields and the many tens of minutes available for particle interactions. The observations, particularly in the early anvil, show that the charge structure in these anvils was quite complex.

Dye, James E.↗

Electrification Within Wintertime Stratiform Regions Sampled During the 2020/2022 NASA IMPACTS Field Campaign

Two nor'easter events—sampled during the NASA Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) field campaign—were examined to characterize the microphysics in relation to the underlying electrification processes within wintertime stratiform regions. A theoretical model was developed to determine whether accretion or diffusion growth regimes were preferential during periods of greatest electrification. Model simulation with electrification parameterization was used to provide supplemental context to the physical processes of in-cloud microphysics and electrification. The strongest electric fields (i.e., ∼80 V m −1 at 20 km) during the 2020 NASA IMPACTS deployment was associated with large non-rimed ice crystals colliding with each other. During the 29–30 January 2022 science flight, the NASA P-3 microphysical probe data demonstrated that non-inductive charging was possible off the coastline of Cape Cod, Massachusetts. Later in the science flight, when the NASA P-3 and ER-2 were coordinating with each other, measured electric fields consistently were less than 8 V m −1 and electrification was subdued owing to reduced concentrations of graupel and large ice hydrometeors. Altogether, the in-situ observations provide evidence for the non-riming collisional charging mechanism and demonstrates that graupel and supercooled liquid water may not be necessary for weak electrification within wintertime stratiform regions. Model output from simulation of both events suggested that the main synoptic snowbands were associated with elevated hydrometeor snow charge density and electric fields.

snowfall↗

Physics Design of a 28 GHz Electron Heating System for the National Spherical Torus Experiment Upgrade

A megawatt-level, 28 GHz electron heating system is being designed to support non-inductive (NI) plasma current (I{sub p}) start-up and local heating and current drive (CD) in H-mode discharges in the National Spherical Torus Experiment Upgrade (NSTX-U). The development of fully NI I{sub p} start-up and ramp-up is an important goal of the NSTX-U research program. 28 GHz electron cyclotron (EC) heating is predicted to rapidly increase the central electron temperature (T{sub e}(0)) of low density NI plasmas generated by Coaxial Helicity Injection (CHI). The increased T{sub e}(0) will significantly reduce the Ip decay rate of CHI plasmas, allowing the coupling of fast wave heating and neutral beam injection. Also 28 GHz electron Bernstein wave (EBW) heating and CD can be used during the I{sub p} flat top in NSTX-U discharges when the plasma is overdense. Ray tracing and Fokker-Planck numerical simulation codes have been used to model EC and EBW heating and CD in NSTX-U. This paper presents a pre-conceptual design for the 28 GHz heating system and some of the results from the numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Megawatt-level 28z GHz Heating System For The National Spherical Torus Experiment Upgrade

The National Spherical Torus Experiment Upgrade (NSTX-U) will operate at axial toroidal fields of < 1 T and plasma currents, Ip < 2 MA. The development of non-inductive (NI) plasmas is a major long-term research goal for NSTX-U. Time dependent numerical simulations of 28 GHz electron cyclotron (EC) heating of low density NI start-up plasmas generated by Coaxial Helicity Injection (CHI) in NSTX-U predict a significant and rapid increase of the central electron temperature (Te(0)) before the plasma becomes overdense. The increased Te(0) will significantly reduce the Ip decay rate of CHI plasmas, allowing the coupling of fast wave heating and neutral beam injection. A megawatt-level, 28 GHz electron heating system is planned for heating NI start-up plasmas in NSTX-U. In addition to EC heating of CHI start-up discharges, this system will be used for electron Bernstein wave (EBW) plasma start-up, and eventually for EBW heating and current drive during the Ip flattop.

Taylor, Gary↗

A Megawatt-level 28z GHz Heating System For The National Spherical Torus Experiment Upgrade

The National Spherical Torus Experiment Upgrade (NSTX-U) will operate at axial toroidal fields of < 1 T and plasma currents, Ip < 2 MA. The development of non-inductive (NI) plasmas is a major long-term research goal for NSTX-U. Time dependent numerical simulations of 28 GHz electron cyclotron (EC) heating of low density NI start-up plasmas generated by Coaxial Helicity Injection (CHI) in NSTX-U predict a significant and rapid increase of the central electron temperature (Te(0)) before the plasma becomes overdense. The increased Te(0) will significantly reduce the Ip decay rate of CHI plasmas, allowing the coupling of fast wave heating and neutral beam injection. A megawatt-level, 28 GHz electron heating system is planned for heating NI start-up plasmas in NSTX-U. In addition to EC heating of CHI start-up discharges, this system will be used for electron Bernstein wave (EBW) plasma start-up, and eventually for EBW heating and current drive during the Ip flattop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in the Understanding of ELM Suppression by Resonant Magnetic Perturbations (RMPs) in DIII-D and Implications for ITER

Experiments on DIII-D have expanding the operating window for RMP ELM suppression to higher q95 with dominant electron heating and fully non-inductive current drive relevant to advanced modes of ITER operation. Robust ELM suppression has also been obtained with a reduced coil set, mitigating the risk of coil failure in maintaining ELM suppression in ITER. These results significantly expand the operating space and reduce risk for obtaining RMP ELM suppression in ITER. Efforts have also been made to search for 3D cause of ELM suppression. No internal non-axisymmetric structure is detected at the top of the pedestal, indicating that the dominant effect of the RMP is to produce an n=0 transport modification of the profiles. Linear two fluid MHD simulations using M3D-C1 indicate resonant field penetration and significant magnetic stochasticity at the top of the pedestal, consistent with the absence of detectable 3D structure in that region. A profile database was developed to compare the scaling of the pedestal and global confinement with the applied 3D field strength in ELM suppressed and ELM mitigated plasmas. The EPED pedestal model accurately predicts the measured pedestal pressure at the threshold of ELM suppression, increasing confidence in theoretical projections to ITER pedestal conditions. Both the H-factor (H(sub)98y2) and thermal energy confinement time do not degrade substantially with applied RMP fields near the threshold of ELM suppression, enhancing confidence in the compatibility of ITER high performance operation with RMP ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extended MHD Studies of Flow-Driven and Reconnecting Instabilities in Toroidal Plasmas

For steady-state reactor scenarios, inductive ohmic current drive alone is not sufficient. If helicity (a topological property which quantifies the knottedness of the magnetic field lines) is created and injected into a plasma configuration, the additional linkage of the magnetic fluxes can sustain the configuration indefinitely against resistive decay. Injection of magnetic helicity into the plasma is closely related to current drive. Various techniques such as DC and AC helicity injection can be used for steady-state current drive, which both rely on relaxation process for core current penetration. However, helicity injection has also been used for edge current drive and non-inductive startup current drive. A solenoid-free plasma startup method called coaxial helicity injection (CHI) has been investigated in the NSTX, and has shown to generate a closedflux equilibrium and produce a CHI-driven current well-coupled to the induction. We propose to perform nonlinear CHI simulations in NSTX, which will provide further insight into the viability of CHI as a startup current drive technique and its role in ultimate steady-state operation of fusion reactors. The goals of our proposed simulations are to understand the physics of current relaxation by CHI in relation to transport and mode dynamics, and to perform long term simulations when CHI is coupled to the induction.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using AORSA to simulate helicon waves in DIIID and ITER

Recent efforts by Vdovin [1] and Prater [2] have shown that helicon waves (fast waves at ~30 ion cyclotron frequency harmonic) may be an attractive option for driving efficient off-axis current drive during non-inductive tokamak operation for DIIID, ITER and DEMO. For DIIID scenarios, the ray tracing code GENRAY has been extensively used to study helicon current drive efficiency and location as a function many plasma parameters. has some limitations on absorption at high cyclotron harmonics, so the full wave code AORSA, which is applicable to arbitrary Larmor radius and can therefore resolve high ion cyclotron harmonics, has been recently used to validate the GENRAY model. It will be shown that the GENRAY and AORSA driven current drive profiles are comparable for the envisioned high temperature and density advanced scenarios for DIIID, where there is high single pass absorption due to electron Landau damping. AORSA results will be shown for various plasma parameters for DIIID and for ITER. Computational difficulties in achieving these AORSA results will also be discussed. * Work supported by USDOE Contract No. DE-AC05-00OR22725 [1] V. L. Vdovin, Plasma Physics Reports, V.39, No.2, 2013 [2] R. Prater et al, Nucl. Fusion, 52, 083024, 2014

Lau, Cornwall H↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Steady state scenario development with elevated minimum safety factor on DIII-D

On DIII-D, a high β scenario with minimum safety factor (q min ) near 1.4 has been optimized with new tools and shown to be a favourable candidate for long pulse or steady state operation in future devices. Furthermore, the new capability to redirect up to 5 MW of neutral beam injection (NBI) from on- to off-axis improves the ability to sustain elevated q min with a less peaked pressure profile. The observed changes increase the ideal magnetohydrodynamics (MHD) n = 1 mode β N limit thus providing a path forward for increasing the noninductive current drive fraction by operating at high β N . Quasi-stationary discharges free of tearing modes have been sustained at βN = 3.5 and β T = 3.6% for two current profile diffusion timescales (about 3 s) limited by neutral beam duration. The discharge performance has normalized fusion performance expected to give fusion gain Q ≈ 5 in a device the size of ITER. Analysis of the poloidal flux evolution and current drive balance show that the loop voltage profile is almost relaxed even with 25% of the current driven inductively, and q min remains elevated near 1.4. Our observations increase confidence that the current profile will not evolve to one unstable to a tearing mode. In preliminary tests a divertor heat flux reduction technique based on producing a radiating mantle with neon injection appears compatible with this operating scenario. 0D model extrapolations suggest it may be possible to push this scenario up to 100% noninductive current drive by raising β N . Similar discharges with q min = 1.5–2 were susceptible to tearing modes and off-axis fishbones, and with q min > 2 lower normalized global energy confinement time is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design considerations for optimizing the transient CHI injector on QUEST

Transient coaxial helicity injection (transient CHI) on the QUEST (Q-shu University Experiment with Steady-State ST) spherical tokamak (ST) has recently validated the floating biased electrode configuration for solenoid-free plasma startup. In support of a significant divertor upgrade on QUEST, the details of the transient CHI injector geometry on QUEST have been examined more closely using tokamak simulation code (TSC) simulations. QUEST uses a HIT-II-like (Helicity Injected Torus) injector configuration in which the injector region is comprised of coaxial injector electrodes located in the lower part of the machine. TSC simulations indicate high injector flux operation may benefit from an increased gap between the coaxial electrodes. This is the first study to examine the differences between an open and closed electrode configuration for solenoid-free plasma startup using transient CHI. Results show that both configurations can generate similar levels of closed flux, but the closed configuration may be easier to implement in some ST designs as a much smaller portion of the injector needs to be close to the injector flux coil. Results show that increasing the electrode gap width from the present 10.8 cm to about 15–20 cm would increase the closed flux fraction by about 40%. The results presented in this paper are generally applicable to the CHI design for other STs.

coaxial helicity injection↗

Initiation and sustainment of tokamak plasmas with local helicity injection as the majority current drive

Local helicity injection (LHI) is a non-solenoidal current drive capable of achieving high- I p tokamak startup with non-invasive current injectors in the plasma scrape-off layer. The choice of injector location within the edge region is flexible but has a profound influence on the nature of the current drive in LHI discharges. New experiments on the Pegasus ST with injection in the high-field-side, lower divertor region produce plasmas dominated by helicity injection current drive, static plasma geometry, and negligible inductive drive. Peak plasma current up to 200 kA, and a sustained plasma current of 100 kA for up to 18 ms, is demonstrated. Maximum achievable plasma current is found to scale approximately linearly with the effective loop voltage from LHI. A newly-observed MHD regime for LHI-driven plasmas in which large-amplitude n = 1 fluctuations at 20–50 kHz are abruptly reduced on the outboard side results in improved current drive. In conclusion, a simultaneous increase in high frequency fluctuations (>400 kHz) inside the plasma edge suggests short wavelength turbulence as an important current drive mechanism during LHI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Latest Results from DIII-D and Their Implications for Future Devices

The DIII-D Tokamak has become one of the major sources of physics and technology data for the design of future large machines such as ITER and CIT. In large part this is because of its extremely flexible design and the ability to run tests or add new diagnostic devices with a minimum of down-time and expense. Fundamental plasma physics studies are still the major focus of our experimental program, but increasingly, we are looking at new ways to answer the complex fusion technology questions emerging from the design studies for the next-generation devices. Recent results have demonstrated world record beta plasmas, long quiescent H-mode operation, partial noninductive current drive using both neutral beam and rf power injection, single- and double-null divertor operation, and divertor particle- and heat-load management. The recently installed Advanced Divertor hardware will allow critical transport experiments to be run with independent control of the density. It will also permit the concept of dc helicity injection current drive to be tested. This paper summarizes our most important recent findings and also outlines a few of the many interesting problems that are now under study to address fusion technology questions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Initial Results from High-Field-Side Transient CHI Start-Up on QUEST

Transient coaxial helicity injection (t-CHI) current start-up using a new design simple electrode configuration has been implemented on the QUEST. Discharges injected from the low field side (LFS) and from the high field side (HFS) were examined. Compared to the LFS injection case, the HFS injection has the advantages of providing access to a higher toroidal field and better controlling the location of the injector flux footprint location. Although the present PF coils on QUEST are not well positioned to form the injector flux on the HFS injector region and there has been a frequent occurrence of the spurious arcs, known as absorber arcs, HFS injection has shown flux evolution in a shape that is suitable for the formation of closed flux surfaces. The discharges were improved by installing an in-vessel-coil and adding a new cylindrical electrode to the existing CHI electrode. Overall, the results show that the new cylindrical electrode allowed the flux to evolve stably while allowing both the inner and the outer injector flux footprint to remain in the vicinity of the cylindrical electrode. This configuration which inherently generates a narrow injector flux footprint width resulted in discharges that strongly suggested the persistence of the CHI generated plasma after the injector current was reduced to zero. These studies have informed us of the need to improve the CHI gas injection system so that the absorber arcs could be better controlled in the HFS injection configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗