Medical ultrasound - From inner space to outer space

During the last decade, medical ultrasound has rapidly become a widely accepted imaging modality used in many medical specialties. It has the advantages that it is noninvasive, does not use ionizing radiation, is relatively inexpensive and is easy to use. Future trends in ultrasound include expanded areas of use, advanced signal processing and digital image analysis including tissue characterization and three-dimensional reconstructions.

Rooney, J. A.↗

Monitoring Temperatures Indirectly in Cooled Combustors

Noninvasive monitoring of temperatures on inner surface of combustion liner of cooled combustor increases liner life, thereby increasing combustor reliability and performance. Technique used in furnaces, reactors, jet engines, rocket engines, stationary turbines, combustors, and heat exchangers. Growth of internal overheating streaks monitored using output from array of thermocouples on outside wall of combustor. Computer analysis of output indicates temperature pattern on combustor lining. Use of data enables timely liner maintenance or overhaul.

Wagner, W.↗

A tomographic technique for aerodynamics at transonic speeds

Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.

Lee, G.↗

In vivo nuclear magnetic resonance imaging

A number of physiological changes have been demonstrated in bone, muscle and blood after exposure of humans and animals to microgravity. Determining mechanisms and the development of effective countermeasures for long duration space missions is an important NASA goal. The advent of tomographic nuclear magnetic resonance imaging (NMR or MRI) gives NASA a way to greatly extend early studies of this phenomena in ways not previously possible; NMR is also noninvasive and safe. NMR provides both superb anatomical images for volume assessments of individual organs and quantification of chemical/physical changes induced in the examined tissues. The feasibility of NMR as a tool for human physiological research as it is affected by microgravity is demonstrated. The animal studies employed the rear limb suspended rat as a model of mucle atrophy that results from microgravity. And bedrest of normal male subjects was used to simulate the effects of microgravity on bone and muscle.

Leblanc, A.↗

Measurement of temperature and density fluctuations in turbulence using an ultraviolet laser

Noninvasive measurement of density and temperature fluctuations in turbulent air flow was examined. The approach used fluorescence of oxygen molecules which are selectively excited by a tunable vacuum ultraviolet laser beam. The strength of the fluorescence signal and its dependence on laser wavelength vary with the density and temperature of the air in the laser beam. Because fluorescence can be detected at 90 degrees from the beam propagation direction, spatial resolution in three dimensions, rather than path-integrated measurements can be achieved. With spatial resolutions of the order of a millimeter and at supersonic air velocities it is necessary to perform each measurement in a time of the order of a microsecond; this is possible by by using laser pulses of ten nanosecond duration. In this method atmospheric O2 is excited by the emission of a tunable ArF excimer laser, and the fluorescence, which spans the 210 to 420 range, is detected by an ultraviolet phototube.

Massey, G. A.↗

Holographic interferometry applied to symmetric aerodynamic models in a wind tunnel

The technique of holographic interferometry provides a means for noninvasive measurement of the air density distribution in the flow field in the vicinity of an aerodynamic model. A test of the applicability of this technique was the objective of this investigation. A holographic interferometer was installed in the 2- by 2-Foot Transonic Wind Tunnel at Ames Research Center. Several tests were conducted with this system on two axisymmetric models, one at subsonic and the other at supersonic speeds. Holograms were made of the flow field around the model for several test conditions. These holograms were reconstructed into interferograms in the laboratory. The fringe distribution (a measure of local densities) from a number of interferograms was digitized for subsequent data reduction. A computer program based on the Fourier transform technique was developed to convert the fringe distribution into a three-dimensional distribution of air density around the model. These results will be presented in this paper.

Perry, R. L.↗

A tomographic technique for aerodynamics at transonic speeds

Computer aided tomography (CAT) provides a means of noninvasively measuring the air density distribution around an aerodynamic model. This technique is global in that a large portion of the flow field can be measured. A test of the applicability of CAT to transonic velocities was studied. A hemispherical-nose cylinder afterbody model was tested at a Mach number of 0.8 with a new laser holographic interferometer at the 2- by 2-Foot Transonic Wind Tunnel. Holograms of the flow field were taken and were reconstructed into interferograms. The fringe distribution (a measure of the local densities) was digitized for subsequent data reduction. A computer program based on the Fourier-transform technique was developed to convert the fringe distribution into three-dimensional densities around the model. Theoretical aerodynamic densities were calculated for evaluating and assessing the accuracy of the data obtained from the tomographic method.

Lee, G.↗

An analysis of estimation of pulmonary blood flow by the single-breath method

The single-breath method represents a simple noninvasive technique for the assessment of capillary blood flow across the lung. However, this method has not gained widespread acceptance, because its accuracy is still being questioned. A rigorous procedure is described for estimating pulmonary blood flow (PBF) using data obtained with the aid of the single-breath method. Attention is given to the minimization of data-processing errors in the presence of measurement errors and to questions regarding a correction for possible loss of CO2 in the lung tissue. It is pointed out that the estimations are based on the exact solution of the underlying differential equations which describe the dynamics of gas exchange in the lung. The reported study demonstrates the feasibility of obtaining highly reliable estimates of PBF from expiratory data in the presence of random measurement errors.

Srinivasan, R.↗

Surface characterization of InP using photoluminescence

Photoluminescence (PL) measurements have been performed on InP samples in situ during various surface treatments including chemical etching, wet anodization, and low-pressure chemical vapor deposition. It was found, in agreement with previously published results, that the magnitude of the PL signal varies markedly with surface treatment due presumably to changes in either surface-state density, and/or surface potential. In an attempt to assess the effectiveness of this noninvasive method as a tool for characterizing and monitoring the progressive development of a semiconductor surface during processing, a number of experiments on InP have been performed. The results indicate that although some uncertainty may exist in assigning a mechanism for the PL change in any given experiment, the general trend appears to be that surface degradation results in a reduced signal. As a result, process steps which enhance the PL intensity are likely to be beneficial in the preparation of a high-quality interface.

Chang, R. R.↗

The growth and in situ characterization of chemical vapor deposited SiO2

This paper reports the results of studies of the kinetics of remote (indirect) plasma enhanced low pressure CVD growth of SiO2 on Si and InP and of the in situ characterization of the electrical surface properties of InP during CVD processing. In the latter case photoluminescence was employed as a convenient and sensitive noninvasive method for characterizing surface trap densities. It was determined that, provided certain precautions are taken, the growth of SiO2 occurs in a reproducible and systematic fashion that can be expressed in an analytic form useful for growth rate prediction. Moreover, the in situ photoluminescence studies have yielded information on sample degradation resulting from heating and chemical exposure during the CVD growth.

Iyer, R.↗

Analog Sensor Of Large-Amplitude Displacements

Noninvasive device measures large amplitudes at low frequencies. Low-angle, light-sensitive system tracks moving leading edge of model. Applications include opening and closing of automatic doors as far and fast as needed.

Miserentino, Robert↗

Crossflow vorticity sensor

A crossflow vorticity sensor for the detection of crossflow vorticity characteristics is described. The sensor is comprised of crossflow sensors which are noninvasively adhered to a swept wing laminar surface either singularly, in multi-element strips, in polar patterns, or in orthogonal patterns. These crossflow sensors are comprised of hot-film sensor elements which operate as a constant temperature anemometer circuit to detect heat transfer rate changes. Accordingly, crossflow vorticity characteristics are determined via cross-correlation. In addition, the crossflow sensors have a thickness which does not exceed a maximum value h in order to avoid contamination of downstream crossflow sensors.

Holmes, Bruce J.↗

Phase separation kinetics in immiscible liquids

The kinetics of phase separation in the succinonitrile-water system are being investigated. Experiments involve initial physical mixing of the two immiscible liquids at a temperature above the consolute, decreasing the temperature into the miscibility gap, followed by iamging of the resultant microstructure as it evolves with time. Refractive index differences allow documentation of the changing microstructures by noninvasive optical techniques without the need to quench the liquid structures for analysis.

Ng, Lee H.↗

Study Of Flow About A Helicopter Rotor

Noninvasive instrument verifies computer program predicting velocities. Laser velocimeter measurements confirm predictions of transonic flow field around tip of helicopter-rotor blade. Report discusses measurements, which yield high-resolution orthogonal velocity components of flow field at rotor-tip. Mach numbers from 0.85 to 0.95, and use of measurements in verifying ability of computer program ROT22 to predict transonic flow field, including occurrences, strengths, and locations of shock waves causing high drag and noise.

Tauber, Michael E.↗

Optical Measurement Of Sound Pressure

Noninvasive technique does not disturb field it measures. Sound field deflects laser beam proportionally to its amplitude. Knife edge intercepts undeflected beam, allowing only deflected beam to reach photodetector. Apparatus calibrated by comparing output of photodetector with that of microphone. Optical technique valuable where necessary to measure in remote, inaccessible, or hostile environment or to avoid perturbation of measured region.

Trinh, Eugene H.↗

Phase separation kinetics in immiscible liquids

The kinetics of phase separation in the succinonitrile-water system are being investigated. Experiments involve initial physical mixing of the two immiscible liquids at a temperature above the consolute, decreasing the temperature into the miscibility gap, followed by imaging of the resultant microstructure as it evolves with time. Refractive index differences allow documentation of the changing microstructures by noninvasive optical techniques without the need to quench the liquid structures for analysis.

Sadoway, D. R.↗

Electro-optical Probing Of Terahertz Integrated Circuits

Electro-optical probe developed to perform noncontact, nondestructive, and relatively noninvasive measurements of electric fields over broad spectrum at millimeter and shorter wavelengths in integrated circuits. Manipulated with conventional intregrated-circuit-wafer-probing equipment and operated without any special preparation of integrated circuits. Tip of probe small electro-optical crystal serving as proximity electric-field sensor.

Bhasin, K. B.↗

Laser Schlieren System Detects Sounds Of Leaks

Hostile environments monitored safely and noninvasively. Modified laser schlieren system acts as microphone to detect sounds of leaks remotely. Sensitive to acoustical frequencies above audible range and especially suited for monitoring leaks of high-pressure steam from boilers or chemical vapors from processing equipment. Does not require placement of delicate equipment in harsh environment monitored, and no contact needed with boiler or other unit being monitored. Detects sound waves via variation of index of refraction of air at acoustical frequencies. Used to monitor sound frequencies beyond range of human hearing.

Shakkottai, Parthasarathy P.↗