Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear medicine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm 3 target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production Review of Accelerator-Based Medical Isotopes

The production of reactor-based medical isotopes is fragile, which has meant supply shortages from time to time. This paper reviews alternative production methods in the form of cyclotrons, linear accelerators and neutron generators. Finally, the status of the production of medical isotopes in China is described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study

Purpose: To develop a new scintillating fiber-based electronic portal imaging device (EPID) with a high quantum efficiency (QE) while preserving an adequate spatial resolution. Methods: Two prototypes were built: one with a single pixel readout and the other with an active matrix flat-panel imager (AMFPI) for readout. The energy conversion layer of both prototypes was made of scintillating fiber layers interleaved with corrugated lead sheets to form a honeycomb pattern. The scintillating fibers have a diameter of 1 mm and the distance between the centers of neighboring fibers on the same layer is 1.35 mm. The layers have 1.22 mm spacing between them. The energy conversion layer has a thickness of 2 cm. The modulation transfer function (MTF), antiscatter properties and sensitivity of the detector with a single pixel readout were measured using a 6-MV beam on a LINAC machine. In addition, a Monte Carlo simulation was conducted to calculate the zero-frequency detective quantum efficiency (DQE(0)) of the proposed detector with an active matrix flat-panel imager for readout. Results: The DQE(0) of the proposed detector can be 11.5%, which is about an order of magnitude higher than that of current EPIDs. The frequency of 50% modulation (f 50 ) of the measured MTF is 0.2 mm –1 at 6 MV, which is comparable to that of video-based EPIDs. The scatter to primary ratio (SPR) measured with the detector at 10 cm air gap and 20 x 20 cm 2 field size is approximately 30% lower than that of ionization chamber–based detectors with a comparable QE. The detector noise which includes the x-ray quantum noise and absorption noise is much larger than the electronic noise per pixel of the flat-panel imager at a dose of less than two LINAC pulses. Thus, the proposed detector is quantum noise limited down to very low doses (~a couple of radiation pulses of the LINAC). A proof-of-concept image has been obtained using a 6-MV beam. Conclusions: This work indicates that by using scintillating fibers and lead layers it is possible to increase the thickness of the detecting materials, and therefore the QE or the DQE(0) of the detector, while maintaining an adequate spatial resolution for MV x-ray imaging. Due to the use of lead as the spacing material, the new detector also has antiscatter property, which will help improve the signal-to-noise ratio of the images. Further investigation to optimize the design of the detector and achieve a better combination of DQE and spatial resolution is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and synthesis of astatinated benzothiazole compounds for their potential use in Targeted Alpha Therapy (TAT) strategies to treat Alzheimer's disease-associated amyloid plaques

Alzheimer's disease (AD) is a terminal neurodegenerative disease characterized by the buildup of amyloid fibrils, amorphous aggregates and tauopathies. Several treatment modalities, which rely on various biological processes to reduce disease burden, have been largely ineffective at treating Alzheimer's disease. Targeted alpha therapy (TAT) has demonstrated positive results in the treatment of cancer. Benzothiazole derivatives have been successfully shown to target these plaques and are used in several imaging applications. One such derivative, Flutemetamol (Vizamyl TM ) is an FDA approved diagnostic tool for PET imaging of AD-associated plaques. We report the radiolabeling of benzothiazole derivatives with 211 At, a 7.2 h alpha emitting radionuclide, using a copper catalyzed reaction with a boronic acid precursor molecule. In conclusion, our final compound [ 211 At]3'-At-PIB-OMe had a radiochemical yield of 55% and was found to be stable for at least 3 h in phosphate buffered saline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The role of multimodality imaging in takotsubo cardiomyopathy

Takotsubo cardiomyopathy (TC) is a syndrome of transient left ventricular (LV) dysfunction mimicking acute coronary syndrome. Although the mechanisms underlying the occurrence of TC are unknown, several imaging techniques contribute to its diagnosis. Here we review the current knowledge about TC, in particular, the pathophysiology and the role of imaging including nuclear cardiovascular medicine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of multi-method-multi-model inference to radiation related solid cancer excess risks models for astronaut risk assessment

The impact of including model-averaged excess radiation risks (ER) into a measure of radiation attributed decrease of survival (RADS) for the outcome all solid cancer incidence and the impact on the uncertainties is demonstrated. It is shown that RADS applying weighted model averaged ER based on AIC weights result in smaller risk estimates with narrower 95% CI than RADS using ER based on BIC weights. Further a multi-method-multi-model inference approach is introduced that allows calculating one general RADS estimate providing a weighted average risk estimate for a lunar and a Mars mission. For males the general RADS estimate is found to be 0.42% (95% CI: 0.38%; 0.45%) and for females 0.67% (95% CI: 0.59%; 0.75%) for a lunar mission and 2.45% (95% CI: 2.23%; 2.67%) for males and 3.91% (95% CI: 3.44%; 4.39%) for females for a Mars mission considering an age at exposure of 40 years and an attained age of 65 years. It is recommended to include these types of uncertainties and to include model-averaged excess risks in astronaut risk assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-dimensional multivariate autoregressive model estimation of human electrophysiological data using fMRI priors

Multivariate autoregressive (MVAR) model estimation enables assessment of causal interactions in brain networks. However, accurately estimating MVAR models for high-dimensional electrophysiological recordings is challenging due to the extensive data requirements. Hence, the applicability of MVAR models for study of brain behavior over hundreds of recording sites has been very limited. Prior work has focused on different strategies for selecting a subset of important MVAR coefficients in the model to reduce the data requirements of conventional least-squares estimation algorithms. Here we propose incorporating prior information, such as resting state functional connectivity derived from functional magnetic resonance imaging, into MVAR model estimation using a weighted group least absolute shrinkage and selection operator (LASSO) regularization strategy. The proposed approach is shown to reduce data requirements by a factor of two relative to the recently proposed group LASSO method of Endemann et al (Neuroimage 254:119057, 2022) while resulting in models that are both more parsimonious and more accurate. The effectiveness of the method is demonstrated using simulation studies of physiologically realistic MVAR models derived from intracranial electroencephalography (iEEG) data. The robustness of the approach to deviations between the conditions under which the prior information and iEEG data is obtained is illustrated using models from data collected in different sleep stages. This approach allows accurate effective connectivity analyses over short time scales, facilitating investigations of causal interactions in the brain underlying perception and cognition during rapid transitions in behavioral state.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production and purification of research scale 161 Tb using cation-exchange semi-preparative HPLC for radiopharmaceutical applications

Terbium-161 ( 161 Tb) is emerging as a promising radionuclide for cancer therapy due to its favorable nuclear properties that are similar to clinically established lutetium-177 ( 177 Lu) along with its therapeutic edge arising from the higher number of Auger and conversion electrons per decay. These low energy electrons result in higher cytotoxicity within a short range of the decaying nuclei to enhance therapeutic efficacy. Despite these promising characteristics, a significant challenge remains in the lack of a domestic 161 Tb supply in the United States, which poses an obstacle to the advancement of 161 Tb-based radiopharmaceutical research and development. Here, this study developed a reliable cation-exchange high-performance liquid chromatography-based method for purification of reactor-produced 161 Tb at quantities suitable to support research and preclinical studies. The purified 161 Tb product showed high radionuclidic purity with excellent radiochemical purity, and the successful labeling studies with the DOTA chelator and DOTA-TATE peptide demonstrated the effective incorporation of the purified 161 Tb into radiopharmaceuticals designed for targeted cancer therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overcoming Barriers to Radiopharmaceutical Therapy (RPT): An Overview From the NRG-NCI Working Group on Dosimetry of Radiopharmaceutical Therapy

Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors that can be well assessed in terms of dosimetry and imaging. Dosimetry in external beam radiation therapy is standard practice. This is not the case, however, in RPT. This NRG (acronym formed from the first letter of the 3 original groups: National Surgical Adjuvant Breast and Bowel Project, the Radiation Therapy Oncology Group, and the Gynecologic Oncology Group)-National Cancer Institute Working Group review describes some of the challenges to improving RPT. The main priorities for advancing the field include (1) developing and adopting best practice guidelines for incorporating patient-specific dosimetry for RPT that can be used at both large clinics with substantial resources and more modest clinics that have limited resources, (2) establishing and improving strategies for introducing new radiopharmaceuticals for clinical investigation, (3) developing approaches to address the radiophobia that is associated with the administration of radioactivity for cancer therapy, and (4) solving the financial and logistical issues of expertise and training in the developing field of RPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the perturbation effect and LET dependence of beam quality correction factors in carbon ion beams

Background: In a recent study, we reported beam quality correction factors, f Q , in carbon ion beams using Monte Carlo (MC) methods for a cylindrical and a parallel-plate ionization chamber (IC). A non-negligible perturbation effect was observed; however, the magnitude of the perturbation correction due to the specific IC subcomponents was not included. Furthermore, the stopping power data presented in the International Commission on Radiation Units and Measurements (ICRU) report 73 were used, whereas the latest stopping power data have been reported in the ICRU report 90. Purpose: The aim of this study was to extend our previous work by computing f Q correction factors using the ICRU 90 stopping power data and by reporting IC-specific perturbation correction factors. Possible energy or linear energy transfer (LET) dependence of the f Q correction factor was investigated by simulating both pristine beams and spread-out Bragg peaks (SOBPs). Methods: The TOol for PArticle Simulation (TOPAS)/GEANT4 MC code was used in this study. A 30 × 30 × 50 cm 3 water phantom was simulated with a uniform 10 × 10 cm 2 parallel beam incident on the surface. A Farmer-type cylindrical IC (Exradin A12) and two parallel-plate ICs (Exradin P11 and A11) were simulated in TOPAS using the manufacturer-provided geometrical drawings. The f Q correction factor was calculated in pristine carbon ion beams in the 150–450 MeV/u energy range at 2 cm depth and in the middle of the flat region of four SOBPs. The k Q correction factor was calculated by simulating the f Qo correction factor in a 60 Co beam at 5 cm depth. The perturbation correction factors due to the presence of the individual IC subcomponents, such as the displacement effect in the air cavity, collecting electrode, chamber wall, and chamber stem, were calculated at 2 cm depth for monoenergetic beams only. Additionally, the mean dose-averaged and track-averaged LET was calculated at the depths at which the f Q was calculated. Results: The ICRU 90 f Q correction factors were reported. The p dis correction factor was found to be significant for the cylindrical IC with magnitudes up to 1.70%. The individual perturbation corrections for the parallel-plate ICs were <1.0% except for the A11 p cel correction at the lowest energy. The f Q correction for the P11 IC exhibited an energy dependence of >1.00% and displayed differences up to 0.87% between pristine beams and SOBPs. Conversely, the f Q for A11 and A12 displayed a minimal energy dependence of <0.50%. The energy dependence was found to manifest in the LET dependence for the P11 IC. A statistically significant LET dependence was found only for the P11 IC in pristine beams only with a magnitude of <1.10%. Conclusions: The perturbation and k Q correction factor should be calculated for the specific IC to be used in carbon ion beam reference dosimetry as a function of beam quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Natural and enriched Cr target development for production of Manganese-52

52 Mn is a promising PET radiometal with a half-life of 5.6 days and an average positron energy of 242 keV. Typically, chromium of natural isotope abundance is used as a target material to produce this isotope through the nat/52 Cr(p,n) 52 Mn reaction. While natural Cr is a suitable target material, higher purity 52 Mn could be produced by transitioning to enriched 52 Cr targets to prevent the co-production of long-lived 54 Mn (t 1/2 = 312 day). Unfortunately, 52 Cr targets are not cost-effective without recycling processes in place, therefore, this work aims to explore routes to prepare Cr targets that could be recycled. Natural Cr foils, metal powder pellets, enriched chromium-52 oxide and Cr(III) electroplated targets were investigated in this work. Each of these cyclotron targets were irradiated, and the produced 52 Mn was purified, when possible, using a semi-automated system. An improved purification by solid-phase anion exchange from ethanol-HCl mixtures resulted in recoveries of 94.5 ± 2.2% of 52 Mn. The most promising target configuration to produce a recyclable target was electroplated Cr(III). This work presents several pathways to optimize enriched Cr targets for the production of high purity 52 Mn.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary results coupling “Stochastic Mean Field” and “Boltzmann-Langevin One Body” models with Geant4

Monte Carlo (MC) simulations are widely used for medical applications and nuclear reaction models are fundamental for the simulation of the particle interactions with patients in ion therapy. Therefore, it is of utmost importance to have reliable models in MC simulations for such interactions. Geant4 is one of the most used toolkits for MC simulation. However, its models showed severe limitations in reproducing the yields measured in the interaction of ion beams below 100 MeV/u with thin targets. For this reason, we interfaced two models, SMF (“Stochastic Mean Field”) and BLOB (“Boltzmann-Langevin One Body”), dedicated to simulate such reactions, with Geant4.

62 RADIOLOGY AND NUCLEAR MEDICINE↗