Search NASA⌕ Search

SEARCH · Search NASA

Results for “occupancy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Electrostatic Superlattices Beyond 1:1 Stoichiometry

ABSTRACT Exotic nanoparticle superstructures can be accessed by harnessing nanoparticle softness and charge regulation, features often viewed as obstacles to structural control. Here, we show that regulated charge mismatch in polymer‐grafted nanoparticles enables the assembly of high‐stoichiometry cubic superlattices. By co‐tuning grafting density, particle size, and bulk composition, we realize ionic‐lattice analogues, such as and , as well as single‐component and superlattices without atomic counterparts. The superlattice has recently been identified theoretically as a photonic band‐gap lattice. These phases emerge from a 1:1 “parent” lattice when local charge neutrality cannot be satisfied, driving either progressive interstitial filling or reorganization into a larger basis. For instance, the systematic occupation of ZnS tetrahedral sites yields , while ligand‐swapping symmetry breaking converts CsCl into . Upon heating, the assemblies exhibit reversible lattice contraction and pronounced negative thermal expansion. Furthermore, the energetic penalty for defects increases with nanoparticle size, facilitating the scalable production of high‐quality, open superlattices for photonic applications.

36 MATERIALS SCIENCE↗

Trap‐Engineering the Persistent Luminescence of Ca 3 Ga 4 O 9 :Tb 3+ via Al 3+ Substitution for Optical Data Storage

Abstract Optically stimulated luminescence (OSL) materials hold great potential for optical data storage (ODS) and anticounterfeiting applications. Nevertheless, the scarcity of suitable luminescent materials with deep‐level traps remains a significant obstacle. Herein, a host substation strategy have been employed to tune the persistent luminescence (PersL) and OSL properties of Ca 3 Ga 4 O 9 :Tb 3+ by Al 3+ substitution through trap engineering and demonstrated their potential. Specifically, the photoluminescence of the Ca 2.985 (Ga 1‐y% Al y% ) 4 O 9 :0.5%Tb 3+ of Tb 3+ is first investigated due to its different occupancies of Ca 2+ . The influence of host substitution on the crystal structure, trap depth, trap density, PersL, and OSL properties have further investigated. A series of strong PersL and OSL peaks from the Ca 2.985 (Ga 1‐y% Al y% ) 4 O 9 :0.5%Tb 3+ with bluish‐green emissions have been observed. The Ca 2.985 (Ga 1‐y% Al y% ) 4 O 9 :0.5%Tb 3+ have shown controllable photon release upon thermal and optical stimuli, enhancing their performance for ODS. Thermally stimulated luminescence suggests that vacancy and defect concentrations inside the Ca 3‐x% (Ga 1‐y% Al y% ) 4 O 9 :x%Tb 3+ can be manipulated by Tb 3+ doping and Al 3+ substitution, which ultimately leads to the formation of deep traps and a broad distribution of traps with increased deep trap concentration. The work demonstrates that trap engineering through Al 3 ⁺ substitution is an effective method for tuning PersL and OSL properties of Ca 2.985 (Ga 1‐y% Al y% ) 4 O 9 :0.5%Tb 3+ for ODS.

Abeywickrama, Thulitha M. [Department of Chemistry↗

On the Ordering Mechanism of Cu + in 2D van der Waals Multiferroic CuCrP 2 S 6

CuCrP 2 S 6 is a van der Waals multiferroic where the tunable Cu + sublattice underpins its exceptional ferroelectric and electronic switching properties. Yet, the microscopic mechanism governing Cu + ordering has remained elusive. Here, we combine single-crystal X-ray and neutron diffraction with pair distribution function analysis to uncover a temperature-driven evolution of Cu + ordering, giving rise to an incommensurate quasi-antipolar phase between the paraelectric and antiferroelectric states. The modulation originates from correlated Cu + occupancy redistribution coupled to breathing distortion of surrounding S 3 triangles, establishing a symmetry-adapted lattice distortion mode. Diffuse scattering persisting over 35 K above the transition confirms that the structural instability follows an order-disorder mechanism. The spontaneous off-centering of Cu + positions CuCrP 2 S 6 as a model platform for correlated order-disorder phenomena in 2D layered ferroics, and provides design principles for next-generation memory and logic devices.

ferroelectrics↗

Realization of Non‐Equilibrium Wurtzite Structure in Heterovalent Ternary MgSiN 2 Film Grown by Reactive Sputtering

The piezoelectric and ferroelectric applications of heterovalent ternary materials are not well explored. Epitaxial MgSiN 2 films are grown at 600 °C on (111)Pt//(001)Al 2 O 3 substrates by the reactive sputtering method using metallic Mg and Si under the N 2 atmosphere. Detailed X-ray diffraction measurements and transmission electron microscopy observations revealed that the epitaxially grown films on the substrates have a hexagonal wurtzite structure with c-axis out-of-plane orientation. The random occupation of this structure by Mg and Si differs from that of the previously reported structure in which these two cations periodically occupy the cationic sites. However, the lattice spacings closely approximate those that are previously reported, irrespective of the ordering, and they are almost comparable with those of (Al 0.8 Sc 0.2 )N. The wide bandgap of >5.0 eV in deposited MgSiN 2 is compatible with that of AlN and suggests durability against the application of strong external electric fields, possibly to induce polarization switching. In addition, MgSiN 2 is shown to have piezoelectric properties with an effective d 33 value of 2.3 pm V −1 for the first time. This work demonstrates the compositional expansion of hexagonal wurtzite to heterovalent ternary nitrides for novel piezoelectric materials, whose ferroelectricity is expected.

36 MATERIALS SCIENCE↗

High‐Entropy Lithium Argyrodite Solid Electrolytes Enabling Stable All‐Solid‐State Batteries

Abstract Superionic solid electrolytes (SEs) are essential for bulk‐type solid‐state battery (SSB) applications. Multicomponent SEs are recently attracting attention for their favorable charge‐transport properties, however a thorough understanding of how configurational entropy (ΔS conf ) affects ionic conductivity is lacking. Here, we successfully synthesized a series of halogen‐rich lithium argyrodites with the general formula Li 5.5 PS 4.5 Cl x Br 1.5‐x (0≤x≤1.5). Using neutron powder diffraction and 31 P magic‐angle spinning nuclear magnetic resonance spectroscopy, the S 2− /Cl − /Br − occupancy on the anion sublattice was quantitatively analyzed. We show that disorder positively affects Li‐ion dynamics, leading to a room‐temperature ionic conductivity of 22.7 mS cm −1 (9.6 mS cm −1 in cold‐pressed state) for Li 5.5 PS 4.5 Cl 0.8 Br 0.7 (ΔS conf =1.98R). To the best of our knowledge, this is the first experimental evidence that configurational entropy of the anion sublattice correlates with ion mobility. Our results indicate the possibility of improving ionic conductivity in ceramic ion conductors by tailoring the degree of compositional complexity. Moreover, the Li 5.5 PS 4.5 Cl 0.8 Br 0.7 SE allowed for stable cycling of single‐crystal LiNi 0.9 Co 0.06 Mn 0.04 O 2 (s‐NCM90) composite cathodes in SSB cells, emphasizing that dual‐substituted lithium argyrodites hold great promise in enabling high‐performance electrochemical energy storage.

Chemistry↗

High‐Pressure Synthesis and Recovery of Single Crystals of the Metastable Manganese Carbide, MnC x

Abstract Transition metal carbides find widespread use throughout industry due to their high strength and resilience under extreme conditions. However, they remain largely limited to compounds formed from the early d‐block elements, since the mid‐to‐late transition metals do not form thermodynamically stable carbides. We report here the high‐pressure bulk synthesis of large single crystals of a novel metastable manganese carbide compound, MnC x (P6 3 /mmc), which adopts the anti‐NiAs‐type structure with significant substoichiometry at the carbon sites. We demonstrate how synthesis pressure modulates the carbon loading, with ~40 % occupancy being achieved at 9.9 GPa.

Chemistry↗

Mechanism of Lithium Ion Exchange Into Spinel Manganese Oxide

Lithium manganese oxide (LMO) is an effective absorbent for lithium recovery from brines, characterized by its high adsorption capacity, excellent regeneration performance, and selectivity. Here, this study investigates the mechanisms of material degradation during lithium loading and unloading in LMO, employing a combination of time‐resolved Raman spectroscopy, X‐ray diffraction, and X‐ray photoelectron spectroscopy. Key findings reveal that the A 1g vibrational mode wavenumber shifts from 635 cm −1 at the onset of lithium ion exchange to 656 cm −1 after 12 min, indicating local symmetry loss and manganese (Mn) loss during lithium intercalation. The proposed lithium exchange mechanism involves initial occupation of tetrahedral interstitial voids, followed by migration into interstitial sites between Mn octahedral sites. Computational modeling suggests that the loss of symmetry in MnO cubane‐like groups occurs as lithium migrates, significantly affecting the Raman spectra. Importantly, the study demonstrates that after 100 cycles of lithium/hydrogen loading, a 24% loss in Mn is observed, which correlates with decreased structural stability; however, the structural integrity of LMO is enhanced when subjected to multiple cycles without complete loading. Here, these insights contribute to the understanding of LMO's performance in lithium recovery applications and highlight potential strategies to optimize its use in future technologies.

15 GEOTHERMAL ENERGY↗

A Mössbauer Spectroscopy Investigation of Nickel‐Zinc Ferrites Synthesized by a Self‐Combustion Method for Soft Magnetic Core Applications

Soft ferrites are materials of interest for magnetic cores, as used for wireless charging transformers. Their low permeabilities, high resistivity, and magnetic polarization make them interesting for high-power electric vehicle charging and drive systems. The nickel-zinc-doped ferrites are of particular interest; however, the compositional space is quite large with respect to dopant concentrations, stoichiometric ratios and synthesis technique. Nickel-zinc spinel ferrites with varying nickel-zinc ratios prepared by a self-combustion reaction followed by heat treatment exhibit good crystallinity, and their low-temperature Mössbauer spectra show local magnetism and site occupation in agreement with materials prepared by solid-state reaction. Thus, the combustion synthesis method offers a facile tunability of compositions, which, combined with the possibility of rapid characterization of atomic-scale magnetism by Mössbauer spectroscopy, enables advances in the compositional and processing space at a fast pace. Low-temperature Mössbauer spectroscopy data for samples with increasing nickel content reveals a systematic increase in average hyperfine field (2.8 T/Ni) and decrease in average isomer shift (−0.036 mm/s/Ni) that can determine the nickel/zinc content, even in the absence of applied magnetic field data. Furthermore, a gradual evolution of color is also observed with increasing nickel content, albeit trends in color depend on sintering conditions.

Mössbauer spectroscopy↗

Mechanism of Contrasting Ionic Conductivities in Li 2 ZrCl 6 via I and Br Substitution

Understanding the complex structural and chemical factors that influence ionic conduction mechanisms is paramount for developing advanced inorganic superionic conductors in all‐solid‐state batteries, particularly halide solid electrolytes with excellent electrochemical oxidative stability and mechanical sinterability. Herein, contrasting ionic conduction behaviors in I − and Br − substituted Li 2 ZrCl 6 are revealed by combining experimental structural analyses and theoretical calculations. The inter‐slab distance along the c ‐axis, which varies with the anion substitution and M2‐M3 site disorder, is a key factor for opening the ab ‐plane conduction and facilitating the overall Li + conduction. Increased M3 site occupancy generally leads to contracted inter‐slab distance. The substantial increase in Li + conductivity upon I substitution (from 0.40 to 0.91 mS cm −1 ) originates from a sufficiently expanded lattice volume owing to its large ionic radii (I − = 2.20 Å), particularly inter‐slab distance that facilitates the ab intra‐plane Li + conduction, which also benefits from decreased M2‐M3 disorder. In contrast, Br (Br − = 1.96 Å) substitution results in insufficiently expanded Li + channels, which, exacerbated by increased M2‐M3 disorder, leads to degradation in Li + conductivity. Implementing I − substituted Li 2 ZrCl 6 resulted in superior electrochemical performance in LiCoO 2 ||Li‐In cells compared to those with an unsubstituted catholyte.

36 MATERIALS SCIENCE↗

Unraveling the Hsp70-ROS-autophagy axis in pentachlorophenol-challenged lung and liver epithelial cells

Pentachlorophenol (PCP) was extensively utilized as an organochlorine pesticide and wood preservative in the United States from the 1930s until the Environmental Protection Agency (EPA) imposed restrictions due to concerns about its toxicity and potential carcinogenic properties. Although it is no longer widely used, PCP remains a concern due to its environmental persistence and potential for long-term health effects. Significant occupational and environmental exposures have likely occurred, with the health and economic costs of PCP exposure potentially being substantial given its known toxicity. Notably, PCP exhibits rapid absorption through both the skin and respiratory system and has been shown to cause hepatotoxicity, developmental toxicity, immunotoxicity, irritation, and carcinogenicity in laboratory animal studies. PCP exposure induces oxidative stress, a key mechanism underlying its inflammatory and toxic effects, which can activate cellular stress responses including upregulation of heat shock protein 70 (Hsp70). Previous studies in lung and liver epithelial cells have shown that Hsp70 and oxidative stress play pivotal roles in triggering autophagy. This study establishes the critical role of the Hsp70-reactive oxygen species (ROS)-autophagy axis in regulating cellular responses to PCP exposure in human alveolar (A549) and liver carcinoma (HepG2) epithelial cells. Our research elucidated the molecular mechanisms underlying PCP's cellular effects, demonstrating that its exposure resulted in increased expression of autophagy-related proteins (Beclin-1, LC3B, ATG12, and ATG16), subunits of NADPH oxidase (NCF-1, NCF-2, NOX2, and Rac), and antioxidant proteins (SOD and GPx) in both lung and liver cell types. Notably, PCP augmented the interaction between Hsp70 and the autophagy regulator Beclin-1. Pretreatment with the ROS inhibitor N-acetylcysteine or Hsp70 knockdown markedly reversed PCP-induced responses. Our in-silico protein–protein docking analysis and molecular dynamics simulation studies revealed enhanced interactions and/or stable confirmations maintained throughout the simulations for TLR4-Hsp70 and Hsp70-Beclin-1 complexes in the presence of PCP. These findings provide a strong foundation for future studies, employing in vivo experimental models and human populations to identify promising targets for PCP-induced toxicity and cellular injury. As a result, these findings may have far-reaching implications for public health and environmental policy, ultimately leading to the identification of biomarkers and the development of more effective interventions for environmentally induced toxicity and diseases.

97 MATHEMATICS AND COMPUTING↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A transfer learning approach to energy-efficient control of small and medium-sized commercial buildings

Model-free reinforcement learning (RL) provides a data-driven and adaptive approach to optimize building energy use while satisfying occupant comfort. This powerful tool does not need any prior knowledge about the environment and system it is optimizing and can adapt its policy based on the changes in captures. Like any other data-driven tool, it faces high training costs due to the extensive agent-environment interactions required to capture long-term building dynamics and user comfort. Transfer learning, particularly policy distillation, offers a promising way to accelerate training by leveraging pretrained RL agents in different building and system types. Here, this study investigates online student distillation, in which the student model updates its neural network weights using outputs from teacher models. The work introduces a student distillation strategy designed for efficient knowledge transfer, along with a teacher selection method that ensures high-quality guidance. The approach is validated using a highly calibrated whole building energy model for a small/medium commercial building test facility. Results show substantial reductions in training time and data requirements while surpassing the performance of ASHRAE Guideline 36, an advanced rule-based control strategy. The distilled RL model required 45% less data and achieved 20% higher cumulative rewards than a state-of-the-art RL model, with faster convergence and lower energy consumption. These outcomes demonstrate that effective transfer learning enables a scalable and data-efficient energy management solution for commercial buildings.

ASHRAE guideline 36↗

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation↗

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Constraining Galaxy-Halo connection using machine learning

We investigate the potential of machine learning (ML) methods to model small-scale galaxy clustering for constraining Halo Occupation Distribution (HOD) parameters. Our analysis reveals that while many ML algorithms report good statistical fits, they often yield likelihood contours that are significantly biased in both mean values and variances relative to the true model parameters. This highlights the importance of careful data processing and algorithm selection in ML applications for galaxy clustering, as even seemingly robust methods can lead to biased results if not applied correctly. ML tools offer a promising approach to exploring the HOD parameter space with significantly reduced computational costs compared to traditional brute-force methods if their robustness is established. Using our ANN-based pipeline, we successfully recreate some standard results from recent literature. Properly restricting the HOD parameter space, transforming the training data, and carefully selecting ML algorithms are essential for achieving unbiased and robust predictions. Among the methods tested, artificial neural networks (ANNs) outperform random forests (RF) and ridge regression in predicting clustering statistics, when the HOD prior space is appropriately restricted. We demonstrate these findings using the projected two-point correlation function (w p (r p )), angular multipoles of the correlation function (ξ ℓ (r)), and the void probability function (VPF) of Luminous Red Galaxies from Dark Energy Spectroscopic Instrument mocks. Our results show that while combining w p (r p ) and VPF improves parameter constraints, adding the multipoles ξ 0 , ξ 2 , and ξ 4 to w p (r p ) does not significantly improve the constraints.

cosmology↗

The health and indoor environmental quality impacts of residential building envelope retrofits: A literature review

Retrofitting existing buildings to improve energy efficiency is an important strategy to meet increasingly stringent energy efficiency targets. While the primary objective of energy efficiency retrofits is to reduce energy consumption and greenhouse gas emissions, retrofits can also result in non-energy impacts (NEIs), which contribute to decision-making processes and overall value of the retrofit. NEIs have been studied extensively in retrofitted residential buildings; however, these studies have historically grouped passive (i.e., building envelope) and active (i.e., heating, ventilation, and air conditioning (HVAC) and energy system) upgrades, making it difficult to identify the underlying mechanism(s) of action for each NEI and developing effective retrofit strategies, based on occupant need. The purpose of this study was to better account for NEIs, based on a literature review, summarizing the current state of knowledge on NEIs associated with residential building envelope retrofits. We limited our search to health- and indoor environmental quality-related NEIs. The review identified strong evidence that building envelope retrofits improve acoustic comfort, wintertime thermal comfort, and respiratory and cardiovascular health outcomes. IAQ outcomes were mixed, with studies reporting both increases and decreases to indoor contaminant concentrations following retrofits. The strength of the effect was generally governed by pre-retrofit contaminant concentrations and whether indoor concentrations were dominated by indoor or outdoor sources. Most studies evaluating summertime thermal comfort identified increased incidence of summertime overheating; however, none of these studies linked the change in thermal conditions to health outcomes. Recommendations for future work include expanding studies to include more market rate housing and the health impacts of summertime overheating in retrofitted buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions concerning housing sufficiency

Housing sufficiency is an emerging concept in the provision of environmentally sustainable housing. It aims for demand-side strategies that reduce excessive, aggregate consumption levels to promote efficient resource utilization and sustainability in the construction sector while providing everyone with a decent standard of housing. However, it is challenging to implement as it interferes with housing-related social and cultural norms. This paper poses and answers ten questions that highlight the challenges, opportunities, and examples of sufficiency strategies in the context of housing provision and the environmental crisis. Question 1 discusses the need for sufficiency as a tool to complement supply-side strategies including efficiency and renewable energy strategies in providing housing. Question 2 examines the concept of housing sufficiency from different perspectives, such as ecological economics and social ecology. Question 3 summarizes the methods used to measure housing sufficiency, with specific focus on the upper and lower limits that respect planetary boundaries and basic human needs. Questions 4 and 5 describe the benefits, potential drawbacks, and rebound effects of housing sufficiency. Questions 6 and 7 examine housing sufficiency in developed and developing countries, respectively. Questions 8 and 9 discuss design strategies, housing occupancy, and tenure models that are needed for housing sufficiency. Finally, Question 10 provides a of policies and regulations that are needed to systematically support the implementation of sufficiency strategies. The questions and answers provide insights for wider application of housing sufficiency in research and practice.

Arceo, Aldrick↗