Search NASA⌕ Search

SEARCH · Search NASA

Results for “operating envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Small Commercial Building Re-tuning: A Primer

To help building owners and managers address issues related to energy-efficient operation of small buildings, DOE has developed a Small Building Re-tuning training curriculum. This "primer" provides additional background information to understand some of the concepts presented in the Small Building Re-tuning training. The intent is that those who are less familiar with the building energy concepts will review this material before taking the building re-tuning training class.

building energy↗

ALMA observations of the water fountain pre-planetary nebula IRAS 16342-3814: high-velocity bipolar jets and an expanding torus

We have mapped {sup 12}CO J = 3–2 and other molecular lines from the “water fountain” bipolar pre-planetary nebula (PPN) IRAS 16342-3814 with ∼0.″35 resolution using Atacama Large Millimeter/submillimeter Array. We find (i) two very high-speed knotty, jet-like molecular outflows; (ii) a central high-density (>few×10{sup 6} cm{sup −3}), expanding torus of diameter 1300 au; and (iii) the circumstellar envelope of the progenitor AGB, generated by a sudden, very large increase in the mass-loss rate to >3.5×10{sup −4} M{sub ⊙} yr{sup −1} in the past ∼455 years. Strong continuum emission at 0.89 mm from a central source (690 mJy), if due to thermally emitting dust, implies a substantial mass (0.017 M{sub ⊙}) of very large (∼millimeter-sized) grains. The measured expansion ages of the above structural components imply that the torus (age ∼160 years) and the younger high-velocity outflow (age ∼110 years) were formed soon after the sharp increase in the AGB mass-loss rate. Assuming a binary model for the jets in IRAS 16342, the high momentum rate for the dominant jet-outflow in IRAS 16342 implies a high minimum accretion rate, ruling out standard Bondi–Hoyle–Lyttleton wind accretion and wind Roche-lobe overflow (RLOF) models with white-dwarf or main-sequence companions. Most likely, enhanced RLOF from the primary or accretion modes operating within common-envelope evolution are needed.

79 ASTRONOMY AND ASTROPHYSICS↗

Noncommutative Poisson boundaries of unital quantum operations

In this paper, Poisson boundaries of unital quantum operations (also called Markov operators) are investigated. In the case of unital quantum channels, compact operators belonging to Poisson boundaries are characterized. Using the characterization of amenable groups by the injectivity of their von Neumann algebras, we will answer negatively some conjectures appearing in the work of Arias et al. ['Fixed points of quantum operations', J. Math. Phys. 43, 5872 (2002)] about injectivity of the commuting algebra of the Kraus operators of unital quantum operations and their injective envelopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metal Matrix Microencapsulated Fuel Technology for LWR Applications

An overview of the metal matrix microencapsulated (M3) fuel concept for the specific LWR application has been provided. Basic fuel properties and characteristics that aim to improve operational reliability, enlarge performance envelope, and enhance safety margins under design-basis accident scenarios are summarized. Fabrication of M3 rodlets with various coated fuel particles over a temperature range of 800-1300 C is discussed. Results from preliminary irradiation testing of LWR M3 rodlets with surrogate coated fuel particles are also reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Regions of azimuthal instability in gyrotrons

This paper is devoted to the analysis of the instability of operating modes in high-power gyrotrons with cylindrically symmetric resonators. This instability manifests itself in destruction of the azimuthally uniform wave envelope rotating in a gyrotron resonator having a transverse size greatly exceeding the wavelength. The appearance of azimuthally nonuniform solutions can be interpreted as simultaneous excitation of modes with different azimuthal indices. This problem is studied self-consistently, i.e., taking into account the temporal evolution of both the azimuthal and axial structures of the wave envelope. The region of gyrotron operation free from this instability is identified. The efficiency achievable in this region can be only 1%-2% lower than the maximum efficiency. It is also possible to address the difference between the theory of mode interaction developed under assumption that all modes have fixed axial structure and the self-consistent theory presented here. As known, for fixed axial mode profiles, single-mode high-efficiency oscillations remain stable no matter how dense is the spectrum of competing modes, while the self-consistent theory predicts stable high-efficiency operation only when the azimuthal index does not exceed a certain critical value. It is shown that the azimuthal instability found in the self-consistent theory is caused by excitation of modes having axial structures different from that of the desired central mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory Evaluation of Energy Recovery Ventilators

Over the years, building scientists have characterized the relationship between building airtightness, exhaust-only appliances airflows, and building depressurization. Now, as the use of deep retrofit measures and new construction practices is growing to realize lower infiltration levels in increasingly tighter envelopes, performance issues can arise with the operation of exhaust-only appliances in a depressurized home. As the depressurization levels climb in tighter homes, many of these exhaust-only appliances see their rated airflows reduced and other related performance issues arise as a result. If sufficiently depressurized, atmospherically vented combustion appliances that may be present in the home can backdraft as well. Furthermore, when exhaust-only appliances operate and the tight home becomes depressurized, water vapor intrusion from outdoors can raise additional issues of mold in the building envelope in more humid climates. The use of energy recovery ventilators (ERVs) in tight homes in mixed-humid and hot-humid climates is already practiced. Unbalancing the ERV by reducing exhaust airflows can provide a means to supply makeup air and reduce the level of home depressurization to mitigate these issues, helping to realize the rated performance of the exhaust-only appliances, achieve safe operation of atmospherically vented combustion, provide the necessary level of fresh ventilation air, and/or improve envelope durability. The unbalanced operation of the ERV to address depressurization can obviously result in unintended consequences in other areas, such as further loss of humidity control in homes in more humid climates. In such tight home scenarios, it is expected that ERVs will operate a substantial amount of time in unbalanced mode with much higher supply than exhaust airflows. Although ERV design performance under balanced flow conditions is well documented, there is no information in the public domain that empirically establishes the effect of unbalanced flow on sensible and latent exchange, especially in the now dominant membrane-type ERV used in residential applications. Therefore, in this task, Gas Technology Institute (GTI) focused on a laboratory evaluation of the unbalanced flow (lowered exhaust airflow) performance of the RenewAire model EV 200, membrane-type ERV delivering 200 standard cubic feet per minute (SCFM) of supply air. The conducted tests show significant variation in ERV effectiveness at different levels of unbalanced air flows. Keeping supply airflow constant and lowering exhaust airflow increases effectiveness of both latent and sensible heat exchange. However, the increased effectiveness is accompanied by reduced capacity for load removal from the supply air, resulting in increased load to the conditioned space. Under decreasing exhaust airflow conditions, sensible load effectiveness exceeded a value of 1 at two sets of testing conditions. This was a result of the temperature rise of the supply air passing through the ERV augmented by the effect of motor heat gain, cross leakage heat gain, and casing heat gain. Consequently, measured sensible effectiveness must be qualified as the so-called Apparent Sensible Effectiveness of the ERV unit (the term used in the Canadian Standards Association C439 standard for testing ERVs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxidation Behavior and Property Degradation of Nuclear Graphites

During its multidecade operation in the core of nuclear reactors, graphite components are subjected to aggressive and continuous exposure to a high field of ionizing and neutron irradiation, high temperature, and various types of present and postulated chemical attacks. High density, high crystallinity polygranular synthetic graphite is unique among other materials for its extraordinary capacity of resisting and adapting to the aggression inflicted by high temperature, high energy neutron bombardment and ionizing gamma radiation. But, as a carbonaceous material, even though of very high purity, graphite is reactive towards common oxidizing agents: oxygen, carbon dioxide, water. Safe operation of HTGRs relies, among other aspects, on engineered safeguard systems for efficient and continuous protection of graphite components against oxidation. Graphite oxidation behavior was, and continues to be, an important direction of theoretical and experimental research, engineering analyses, models and simulations, and design and safety regulations. The avalanche of publications, reports, experimental data, computer codes, and regulatory documents related to oxidation behavior of nuclear graphite is now accelerating to new levels, prompted by the increased interest for nuclear energy as a clean, carbon-free energy source. Even though public’s perception of nuclear energy advantages may still be influenced by the memories of past accidents of nuclear reactors from generations II and III, the community of informed scientists and engineers, regulators and statemen knows that generation IV of nuclear reactors is designed at very high safety standards, doubled by great advances of scientific knowledge and technological progress. One of routes of these recent advances is directed at better understanding of graphite oxidation behavior, its relationship with graphite manufacturing and microstructural properties, along with the effects of various environmental factors and process variables. Together, the recent progress in manufacturing, properties characterization, and modeling of intricated physical and chemical processes that concur to the oxidation behavior led to development of powerful simulation codes able to analyze various scenarios of normal operation and hypothetical off-normal events, and thus to clearly specify the allowable parameters envelopes for the designers, constructors, and operators of current and future modular HTGRs. This review begins with an introduction on manufacturing methods, structure, and properties of nuclear graphite, including basic requirements that this specialty graphite type must satisfy for nuclear use. It continues with a chapter on environmental effects on nuclear graphite, where emphasis is placed less on irradiation and much more on oxidation phenomena, their safety implications, and the basic traits of chronic and acute oxidation by air (oxygen) and water (humidity, steam). Particular attention is placed on the three graphite grades of interest for this document (IG-110, NBG-18, PCEA). A chapter on properties degradation induced by oxidation follows, with focus on density, dimensional, and mechanical properties changes. The next chapter is intended as a brief review of various approaches used for modeling of graphite oxidation behavior. It summarizes the progress of oxidation models, from the early attempts to complex computational approaches interfaced with specialized computer codes designed for nuclear reactor simulations. Last, a list is presented of knowledge gaps where more research is needed. A short summary concludes the review.

36 MATERIALS SCIENCE↗

Exact Solution of the Envelope Equations for a Matched Quadrupole-Focused Beam in the Zero Space-Charge Limit

The Kapchinskij-Vladimirskij equations are widely used to study the evolution of the beam envelopes in a periodic system of quadrupole focusing cells. In this paper, we analyze the case of a matched beam. Our model is analogous to that used by Courant and Snyder [E.D. Courant and H.S. Snyder, Ann. Phys. 3, 1 (1958)], who obtained a first-order approximate solution for a synchrotron. Here, we treat a linear machine and obtain an exact solution. The model uses a full occupancy, piecewise-constant focusing function and neglects space charge. There are solutions in an infinite number of bands as the focus strength is increased. All these bands are stable. Our explicit results for the phase advance {sigma} and the envelopes a(z) and b(z) are exact for all phase advances except multiples of 180{sup o}, where the behavior is singular. We find that the peak envelope size is minimized for {delta} {approx} 81{sup o}. Actual operation in the higher bands would require very large, very accurate field strengths and would produce significantly larger envelope excursions. If such operation were found to be feasible, there would be interesting applications which we discuss.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional simulations of mixing in classical novae: The effect of white dwarf composition and mass

Context. Classical novae are explosive phenomena that take place in stellar binary systems. They are powered by mass transfer from a low-mass main sequence star onto either a CO or ONe white dwarf. The material accumulates for 104–105 yr until ignition under degenerate conditions, resulting in a thermonuclear runaway. The nuclear energy released produces peak temperatures of ~0.1–0.4 GK. During these events, 10 –7 –10 –3 M ⊙ enriched in intermediate-mass elements, with respect to solar abundances, are ejected into the interstellar medium. Yet, the origin of the large metallicity enhancements and the inhomogeneous distribution of chemical species observed in high-resolution spectra of ejected nova shells is not fully understood. Aims. Recent multidimensional simulations have demonstrated that Kelvin-Helmholtz instabilities that operate at the core-envelope interface can naturally produce self-enrichment of the accreted envelope with material from the underlying white dwarf at levels that agree with observations. Yet, such multidimensional simulations have been performed for a small number of cases and much of the parameter space remains unexplored. Methods. We explored the dredge-up, driven by Kelvin-Helmholtz instabilities, for white dwarf masses in the range 0.8–1.25 M ⊙ and different core compositions, that is, CO-rich and ONe-rich substrates. We present a set of five numerical simulations performed in two dimensions aimed at analyzing the possible impact of the white dwarf mass, and composition, on the metallicity enhancement and explosion characteristics. Results. At the time we stop the simulations, we observe greater mixing (~30% higher when measured in the same conditions) and more energetic outbursts for ONe-rich substrates than for CO-rich substrates and more massive white dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Computational hydrodynamics and optical performance of inductively-coupled plasma adaptive lenses

This study addresses the optical performance of a plasma adaptive lens for aero-optical applications by using both axisymmetric and three-dimensional numerical simulations. Plasma adaptive lenses are based on the effects of free electrons on the phase velocity of incident light, which, in theory, can be used as a phase-conjugation mechanism. A closed cylindrical chamber filled with Argon plasma is used as a model lens into which a beam of light is launched. The plasma is sustained by applying a radio-frequency electric current through a coil that envelops the chamber. Four different operating conditions, ranging from low to high powers and induction frequencies, are employed in the simulations. The numerical simulations reveal complex hydrodynamic phenomena related to buoyant and electromagnetic laminar transport, which generate, respectively, large recirculating cells and wall-normal compression stresses in the form of local stagnation-point flows. In the axisymmetric simulations, the plasma motion is coupled with near-wall axial striations in the electron-density field, some of which propagate in the form of low-frequency traveling disturbances adjacent to vortical quadrupoles that are reminiscent of Taylor-Görtler flow structures in centrifugally unstable flows. Although the refractive-index fields obtained from axisymmetric simulations lead to smooth beam wavefronts, they are found to be unstable to azimuthal disturbances in three of the four three-dimensional cases considered. The azimuthal striations are optically detrimental, since they produce high-order angular aberrations that account for most of the beam wavefront error. A fourth case is computed at high input power and high induction frequency, which displays the best optical properties among all the three-dimensional simulations considered. In particular, the increase in induction frequency prevents local thermalization and leads to an axisymmetric distribution of electrons even after introduction of spatial disturbances. The results highlight the importance of accounting for spatial effects in the numerical computations when optical analyses of plasma lenses are pursued in this range of operating conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using Whole-House Field Tests to Empirically Derive Moisture Buffering Model Inputs

Building energy simulations can be used to predict a building's interior conditions, along with the energy use associated with keeping these conditions comfortable. These models simulate the loads on the building (e.g., internal gains, envelope heat transfer), determine the operation of the space conditioning equipment, and then calculate the building's temperature and humidity throughout the year. The indoor temperature and humidity are affected not only by the loads and the space conditioning equipment, but also by the capacitance of the building materials, which buffer changes in temperature and humidity. This research developed an empirical method to extract whole-house model inputs for use with a more accurate moisture capacitance model (the effective moisture penetration depth model). The experimental approach was to subject the materials in the house to a square-wave relative humidity profile, measure all of the moisture transfer terms (e.g., infiltration, air conditioner condensate) and calculate the only unmeasured term: the moisture absorption into the materials. After validating the method with laboratory measurements, we performed the tests in a field house. A least-squares fit of an analytical solution to the measured moisture absorption curves was used to determine the three independent model parameters representing the moisture buffering potential of this house and its furnishings. Follow on tests with realistic latent and sensible loads showed good agreement with the derived parameters, especially compared to the commonly-used effective capacitance approach. These results show that the EMPD model, once the inputs are known, is an accurate moisture buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Whole-House Field Tests to Empirically Derive Moisture Buffering Model Inputs

Building energy simulations can be used to predict a building's interior conditions, along with the energy use associated with keeping these conditions comfortable. These models simulate the loads on the building (e.g., internal gains, envelope heat transfer), determine the operation of the space conditioning equipment, and then calculate the building's temperature and humidity throughout the year. The indoor temperature and humidity are affected not only by the loads and the space conditioning equipment, but also by the capacitance of the building materials, which buffer changes in temperature and humidity. This research developed an empirical method to extract whole-house model inputs for use with a more accurate moisture capacitance model (the effective moisture penetration depth model). The experimental approach was to subject the materials in the house to a square-wave relative humidity profile, measure all of the moisture transfer terms (e.g., infiltration, air conditioner condensate) and calculate the only unmeasured term: the moisture absorption into the materials. After validating the method with laboratory measurements, we performed the tests in a field house. A least-squares fit of an analytical solution to the measured moisture absorption curves was used to determine the three independent model parameters representing the moisture buffering potential of this house and its furnishings. Follow on tests with realistic latent and sensible loads showed good agreement with the derived parameters, especially compared to the commonly-used effective capacitance approach. These results show that the EMPD model, once the inputs are known, is an accurate moisture buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insights into Engine Knock: Comparisons of Knock Metrics across Ranges of Intake Temperature and Pressure in the CFR Engine

Of late there has been a resurgence in studies investigating parameters that quantify combustion knock in both standardized platforms and modern spark-ignition engines. However, it is still unclear how metrics such as knock (octane) rating, knock onset, and knock intensity are related and how fuels behave according to these metrics across a range of conditions. As part of an ongoing study, the air supply system of a standard Cooperative Fuel Research (CFR) F1/F2 engine was modified to allow mild levels of intake air boosting while staying true to its intended purpose of being the standard device for American Society for Testing and Materials (ASTM)-specified knock rating or octane number tests. For instance, the carburation system and intake air heating manifold are not altered, but the engine was equipped with cylinder pressure transducers to enable both logging of the standard knockmeter readout and state-of-the-art indicated data. For this study, the engine was operated using primary reference fuel 90 (PRF90) at 600 rpm, first following the procedures of the ASTM D2699 research octane number test protocol in order to define the geometric compression ratio set point for standard knock number. Thereafter, compression ratio sweeps were conducted at intake temperatures ranging from 30 to 150°C and intake air boost extending from 0 to 0.3 bar above ambient. The resulting operating map provided a broad envelope of compressed in-cylinder conditions relevant to modern spark-ignition engines. Detailed analysis of the indicated data highlighted a poor correlation between established knock intensity metrics and the knockmeter reading, which is used to characterize a fuel’s octane number. It was further found that the auto-ignition characteristics of PRF90 could be perturbed by means of intake air boosting and heating without being captured by the knockmeter reading.

Rockstroh, Toby↗

Progress Towards Treating the Sludges Produced During Spent Fuel Processing - 19546

As a consequence of over 50 years of Magnox reprocessing, Sellafield site is in possession of significant quantities of Magnox sludge. This sludge material is the by-product of corrosion of the magnesium based Magnox metal that clads the Magnox fuel elements. Retrievals and processing of this material poses a significant challenge as corrosion of Magnox metal has occurred under a variety of conditions and over a significant period of time, in a variety of locations. Devising processes to treat heterogeneous materials offers a significant challenge to identify technologies with robust envelopes of acceptance, to effectively operate together. This is further compounded by difficulties defining test programmes and materials for testing that will provide assurance that nonradioactive testing is suitably representative or bounding. An overview of the significant body of work undertaken to process Sellafield's Magnox sludge is provided, from the thousands of commercially sensitive reports generated over the past five decades. This covers the sampling, characterisation, strategy and process evolution, technology development and test materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Safety Requirements for the B695 Segment

This document contains Technical Safety Requirements (TSRs) for the Radioactive and Hazardous Waste Management (RHWM) Division's B695 Segment of the Decontamination and Waste Treatment Facility (DWTF) at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the B695 Segment. The TSRs are derived from the Documented Safety Analysis (DSA) for the B695 Segment (LLNL 2007). The analysis presented there determined that the B695 Segment is a low-chemical hazard, Hazard Category 3, nonreactor nuclear facility. The TSRs consist primarily of inventory limits as well as controls to preserve the underlying assumptions in the hazard analyses. Furthermore, appropriate commitments to safety programs are presented in the administrative controls section of the TSRs. The B695 Segment (B695 and the west portion of B696) is a waste treatment and storage facility located in the northeast quadrant of the LLNL main site. The approximate area and boundary of the B695 Segment are shown in the B695 Segment DSA. Activities typically conducted in the B695 Segment include container storage, lab-packing, repacking, overpacking, bulking, sampling, waste transfer, and waste treatment. B695 is used to store and treat radioactive, mixed, and hazardous waste, and it also contains equipment used in conjunction with waste processing operations to treat various liquid and solid wastes. The portion of the building called Building 696 Solid Waste Processing Area (SWPA), also referred to as B696S in this report, is used primarily to manage solid radioactive, mixed, and hazardous waste. Operations specific to the SWPA include sorting and segregating waste, lab-packing, sampling, and crushing empty drums that previously contained waste. Furthermore, a Waste Packaging Unit will be permitted to treat hazardous and mixed waste. RHWM generally processes LLW with no, or extremely low, concentrations of transuranics (i.e., much less than 100 nCi/g). Wastes processed often contain only depleted uranium and beta- and gamma-emitting nuclides, e.g., {sup 90}Sr, {sup 137}Cs, {sup 3}H. Chapter 5 of the DSA documents the derivation of TSRs and develops the operational limits that protect the safety envelope defined for this facility. The DSA is applicable to the handling of radioactive waste stored and treated in the B695 Segment. Section 5 of the TSR, Administrative Controls, contains those Administrative Controls necessary to ensure safe operation of the B695 Segment. A basis explanation for each of the requirements described in Section 5.5, Specific Administrative Controls is provided in Appendix B. The basis explanation does not constitute an additional requirement, but is intended as an expansion of the logic and reasoning behind development of the requirement. Programmatic Administrative Controls are addressed in Section 5.6. This introduction to the B695 Segment TSRs is not part of the TSR limits or conditions and contains no requirements related to B695 Segment operations or to the safety analyses in the DSA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technical Safety Requirements for the B695 Segment of the Decontamination and Waste Treatment Facility

This document contains Technical Safety Requirements (TSRs) for the Radioactive and Hazardous Waste Management (RHWM) Division's B695 Segment of the Decontamination and Waste Treatment Facility (DWTF) at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the B695 Segment of the DWTF. The TSRs are derived from the Documented Safety Analysis (DSA) for the B695 Segment of the DWTF (LLNL 2004). The analysis presented there determined that the B695 Segment of the DWTF is a low-chemical hazard, Hazard Category 3, nonreactor nuclear facility. The TSRs consist primarily of inventory limits as well as controls to preserve the underlying assumptions in the hazard analyses. Furthermore, appropriate commitments to safety programs are presented in the administrative controls section of the TSRs. The B695 Segment of the DWTF (B695 and the west portion of B696) is a waste treatment and storage facility located in the northeast quadrant of the LLNL main site. The approximate area and boundary of the B695 Segment of the DWTF are shown in the B695 Segment of the DWTF DSA. Activities typically conducted in the B695 Segment of the DWTF include container storage, lab-packing, repacking, overpacking, bulking, sampling, waste transfer, and waste treatment. B695 is used to store and treat radioactive, mixed, and hazardous waste, and it also contains equipment used in conjunction with waste processing operations to treat various liquid and solid wastes. The portion of the building called Building 696 Solid Waste Processing Area (SWPA), also referred to as B696S in this report, is used primarily to manage solid radioactive waste. Operations specific to the SWPA include sorting and segregating low-level waste (LLW) and transuranic (TRU) waste, lab-packing, sampling, and crushing empty drums that previously contained LLW. A permit modification for B696S was submitted to DTSC in January 2004 to store and treat hazardous and mixed waste. Upon approval of the permit modification, B696S rooms 1007, 1008, and 1009 will be able to store hazardous and mixed waste for up to 1 year. Furthermore, an additional drum crusher and a Waste Packaging Unit will be permitted to treat hazardous and mixed waste. RHWM generally processes LLW with no, or extremely low, concentrations of transuranics (i.e., much less than 100 nCi/g). Wastes processed often contain only depleted uranium and beta- and gamma-emitting nuclides, e.g., {sup 90}Sr, {sup 137}Cs, {sup 3}H. Chapter 5 of the DSA documents the derivation of TSRs and develops the operational limits that protect the safety envelope defined for this facility. The DSA is applicable to the handling of radioactive waste stored and treated in the B695 Segment of the DWTF. Section 5 of the TSR, Administrative Controls, contains those Administrative Controls necessary to ensure safe operation of the B695 Segment of the DWTF. A basis explanation follows each of the requirements described in Section 5.5, Specific Administrative Controls. The basis explanation does not constitute an additional requirement, but is intended as an expansion of the logic and reasoning behind development of the requirement. Programmatic Administrative Controls are addressed in Section 5.6.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory Evaluation of Energy Recovery Ventilators

Over the years, building scientists have characterized the relationship between building airtightness, exhaust-only appliances airflows, and building depressurization. Now, as the use of deep retrofit measures and new construction practices is growing to realize lower infiltration levels in increasingly tighter envelopes, performance issues can arise with the operation of exhaust-only appliances in a depressurized home. As the depressurization levels climb in tighter homes, many of these exhaust-only appliances see their rated airflows reduced and other related performance issues arise as a result. If sufficiently depressurized, atmospherically vented combustion appliances that may be present in the home can backdraft as well. Furthermore, when exhaust-only appliances operate and the tight home becomes depressurized, water vapor intrusion from outdoors can raise additional issues of mold in the building envelope in more humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Evaluation of Energy Recovery Ventilators

Over the years, building scientists have characterized the relationship between building airtightness, exhaust-only appliances airflows, and building depressurization. Now, as the use of deep retrofit measures and new construction practices is growing to realize lower infiltration levels in increasingly tighter envelopes, performance issues can arise with the operation of exhaust-only appliances in a depressurized home. As the depressurization levels climb in tighter homes, many of these exhaust-only appliances see their rated airflows reduced and other related performance issues arise as a result. If sufficiently depressurized, atmospherically vented combustion appliances that may be present in the home can backdraft as well. Furthermore, when exhaust-only appliances operate and the tight home becomes depressurized, water vapor intrusion from outdoors can raise additional issues of mold in the building envelope in more humid climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗