Search NASA⌕ Search

SEARCH · Search NASA

Results for “operating envelopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Method for In-Situ Q₀ Measurements of High-Quality SRF Resonators

Accelerator projects such as LCLS-II naturally require low-loss superconducting (SRF) cavities. Due to strong demand for improving intrinsic quality factor (Q₀), importance of accurate cavity characterization increases. We propose a method to measure Q₀ in situ for an SRF resonator installed in its cryogenic module and connected with a RF feed source via a fixed RF coupler. The method exploits measurements of a response for an SRF resonator fed by an amplitude-modulated signal. Such a signal can be synthesized as a beat-wave composed of two frequencies that are close to the resonant frequency. Analyzing the envelope of the reflected signal, one can find the difference in reflection for the chosen frequencies and use them to compute the intrinsic Q. We also develop the methodology to carry out measurements of Q₀ at the nominal cavity operating voltage. We verified our method in experiments with a room temperature copper resonator and with two SRF resonators including Fermilab’s 650 MHz cavity and JLab’s 1500 MHz cavity.

43 PARTICLE ACCELERATORS↗

ECAR-6076 Rev 0 MARVEL Reactor End of Life Enveloping Radiological Source Term

As part of the Microreactor Applications Research Validation and Evaluation Project (MARVEL) design effort, an enveloping end of life radiological source term for the reactor fuel and sodiumpotassium (NaK) eutectic coolant is calculated in support of the MARVEL preliminary hazard evaluation. The source term calculation assumes slightly more than two-years of uninterrupted operations at a power of about 120 kW for a total energy of 7,600,000 MJ which exceeds the planned two-year operation at 100 kW. The Reactor modeling was performed with MCNP6 Version 1.0 and the depletion was performed using the COUPLE and ORIGEN modules from the SCALE Version 6.2 code package.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Embodied Carbon Reduction in New Construction: Reference Guide

The U.S. Department of Energy launched the Advanced Building Construction (ABC) Initiative in 2019 to modernize and streamline building renovation and construction processes that facilitate the integration of high-performance and low-carbon solutions in the U.S. building stock. There are four attributes of ABC that are the focus of the Initiative: affordable, fast, appealing, and low carbon. Substantial improvements have been made to reduce operational carbon emissions of buildings through efficiency and electrification. However, to achieve low-carbon new construction buildings, increased efforts to reduce the embodied carbon of buildings are needed. Embodied carbon emissions in buildings come primarily from the manufacturing of building envelope materials such as concrete, steel, lumber, and glass, among others. Recent studies show that construction and renovation of buildings account for 5% of energy use and 10% of carbon emissions globally.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Development and validation of a second-order thermal network model for residential buildings

Heating, Ventilation, and Air Conditioning (HVAC) systems can maintain the space air temperature of residential buildings, either directly by heating/cooling the air, or indirectly via heat transfer to and from the building structure that acts as a thermal mass. Hence, HVAC systems can help achieve load shifting, peak load reduction, and/or energy cost saving, thus enabling grid-interactive HVAC operation. A home thermal model that can accurately reflect the dynamics of the space air and interior wall surface temperatures, is therefore valuable. This paper develops such a model using the standard RC (resistance-capacitance) approach. The model contains a virtual envelope node and an internal space node and is thus second-order. A hybrid parameter identification scheme, made up of the least-squares and optimal search methods, is also developed. The proposed model and scheme were validated using data collected from a test home. It was found that a modest amount of training data was sufficient to yield reliable parameter estimates and accurate prediction. It was also found that when making 24-hour-ahead prediction of the space air temperature, both methods had comparable performances when the training data began in a transition season. However, when they began in an HVAC season, the optimal search method performed better. Furthermore, the least-squares method is recommended during a transition season due to its lower computational burden, while the optimal search method is recommended during an HVAC season due to its better estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

City-level impacts of building tune-ups: Findings from Seattle's building tune-ups program

Many U.S. cities are implementing policies to reduce greenhouse gas (GHG) emissions of their buildings. These range from building energy benchmarking and disclosure to building performance standards (BPS) that require buildings to meet specific targets of energy use or emissions. The City of Seattle adopted a climate action plan in 2013 that set a goal of zero net GHG emissions in the road transportation, buildings, and waste sectors by 2050, with a number of near and long term actions. Seattle implemented mandatory building tune-ups in 2016, applying to commercial buildings larger than 50,000 sqft. Building tune-ups1 involve assessment and implementation of operational and maintenance (O + M) improvements to achieve energy and water efficiency, such as changes to thermostat set points or adjusting lighting or irrigation schedules. Seattle's tune-ups program covered 27 such improvements in HVAC, lighting, domestic hot water, and envelope systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recommendations for an Applicant to Calculate Activity Data for Greenhouse Gases Estimates

In 2009, the U.S. Nuclear Regulatory Commission (NRC) directed the NRC staff to address climate change issues and consider the impacts of the emissions of carbon dioxide (CO 2 ) and other greenhouse gases (GHGs) in its environmental reviews for major licensing actions (NRC 2009b). To implement this direction from the Commission, the staff issued guidance in 2011 and updated guidance in 2014 in Attachment 1 to Interim Staff Guidance COL/ESP-ISG-026 (NRC 2011; NRC 2014). This guidance provides a simpler method than the method described in RG 4.2 Rev. 3, that an applicant can use to meet the plant parameter envelope (PPE) value from the Generic Environmental Impact Statement for Licensing of New Nuclear Reactors (NR GEIS). NRC staff estimated the 97-year lifecycle GHG emissions from a reference 1000 megawatt electrical (MWe) light-water reactor (LWR) for various activities associated with construction, operation (including uranium fuel cycle), and decommissioning of nuclear power plants and presented the results in Appendix H of the NR GEIS. Appendix H of the NR GEIS includes estimates of direct emissions from construction equipment and emergency diesel engines in a nuclear facility and indirect emissions from workforce vehicular traffic, fuel transportation and the uranium fuel cycle. The NR GEIS Section 3.3 extended the estimates in Appendix H for the installation of two 1000 MWe nuclear reactors on the same site. Scaling factors were used to extrapolate the GHG emissions of a reference 1000 MWe reactor to a two-unit nuclear reactor plant (each reactor unit generating 1000 MWe). GHG emission estimates for building, operation, decommissioning and safe storage (SAFSTOR) for a two-unit nuclear reactor plant would be based on the plant’s physical size, and therefore estimates for these source categories were assumed to be twice the value of the reference 1000 MWe reactor. However, GHG emissions from the fuel cycle (including fuel transportation) were scaled upward by a factor of 3, based on plant efficiencies greater than the 80 percent assumption in Appendix H. Table 1 below shows the PPE emissions for two 1000 MWe nuclear reactors as provided in NR GEIS. The total GHG emissions for two 1000 MWe reactors were calculated as 2,534,000 metric tons (MT) of CO 2 equivalent (CO 2 (e)) based on a 97 year GHG life cycle period. The GHG emissions lifetime of 97 years for a reference nuclear reactor includes a 7-year building phase, 40 years of operation, 10 years of active decommissioning, and 40 years of SAFSTOR operations (NRC 2024). Construction equipment and vehicular traffic from workers commute would contribute to the GHG emissions during a 7-year building phase. Uranium fuel cycle, vehicular traffic, fuel and waste transportation, and testing of standby diesel generators would contribute to GHG emissions during the 40-year operations phase. While NRC’s regulations allow up to 60 years of reactor facility decommissioning, Appendix H estimated that most of the GHGs would occur over an estimated 10-year period during which to the licensee would engage in significant demolition and earth-moving activities, as discussed in Supplement 1 to NUREG-0586 (NRC 2002). Vehicular traffic by the workforce during a 40-year SAFSTOR period would additionally contribute GHG emissions. The carbon footprint for a 40-year SAFSTOR period was separately analyzed from the decommissioning activities as provided in Table YYYY-2 of the staff issued guidance in 2011 (NRC 2011).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Long-term Storage of ILW: Building Stores with the Appropriate Environmental Controls - 20294

In the UK, containers for the storage and disposal of intermediate level radioactive waste (ILW) typically use stainless steel due to its excellent mechanical properties and corrosion resistance. The period of interim storage before a disposal facility is available, however, is longer than available engineering experience with stainless steels in relevant environmental conditions. Additionally, after disposal the ability of ILW containers to withstand further periods of exposure to the environment is expected to provide substantial benefits to the operation of a disposal facility and the safety case underpinning its closure. For these reasons, although there have been no instances of failure of stainless steels in indoor storage conditions, a focused R and D programme has been carried out to identify the environmental envelope over which the material does not significantly degrade. In this study we summarise experimental and modelling studies carried out over the last decade to build a solid mechanistic understanding of the corrosion behaviour of stainless steels in indoor atmospheric conditions. We then identify suitable environmental regimes to minimise the risk of degradation processes and explore approaches to monitoring the storage conditions to gain confidence in the long-term performance of the system. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Genetic control of photoprotection and photosystem II operating efficiency in plants

Summary Photoprotection against excess light via nonphotochemical quenching (NPQ) is indispensable for plant survival. However, slow NPQ relaxation under low light conditions can decrease yield of field‐grown crops up to 40%. Using semi‐high‐throughput assay, we quantified the kinetics of NPQ and photosystem II operating efficiency (ΦPSII) in a replicated field trial of more than 700 maize ( Zea mays ) genotypes across 2 yr. Parametrized kinetics data were used to conduct genome‐wide association studies. For six candidate genes involved in NPQ and ΦPSII kinetics in maize the loss of function alleles of orthologous genes in Arabidopsis ( Arabidopsis thaliana ) were characterized: two thioredoxin genes, and genes encoding a transporter in the chloroplast envelope, an initiator of chloroplast movement, a putative regulator of cell elongation and stomatal patterning, and a protein involved in plant energy homeostasis. Since maize and Arabidopsis are distantly related, we propose that genes involved in photoprotection and PSII function are conserved across vascular plants. The genes and naturally occurring functional alleles identified here considerably expand the toolbox to achieving a sustainable increase in crop productivity.

59 BASIC BIOLOGICAL SCIENCES↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low Carbon Technology Strategies: Hospital

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon hospitals within their existing building portfolios. Hospitals typically include complex heating and cooling systems and specialty medical equipment.

analytics↗

Exploring filamentous fungi depolymerization of corn stover in the context bioenergy queuing operations

Recalcitrance of lignocellulosic feedstocks to depolymerization is a significant barrier for bioenergy production approaches that require conversion of monomeric carbohydrates to renewable energy sources. This study assesses how low-cost modifications in the feedstock supply chain can be transformed into targeted pretreatments in the context of the entire bioenergy supply chain. The aim of this research is to overcome the physiochemical barriers in corn stover that necessitate increased severity in conversion in terms of chemical loading, temperature, and residence time. Corn stover samples were inoculated with a selective (Ceriporiopsis subvermispora) and non-selective (Phaenarochaete chrysosporium) lignin degrading filamentous fungal strains, then stored aerobically to determine the working envelope for fungal pretreatment to achieve lignin degradation. Dry matter loss and gross chemical makeup of corn stover varied by the length of treatment (2 and 4 weeks) and by the moisture content of the treated corn stover samples (40 and 60%, wet basis). Dry matter loss in P. chrysosporium inoculated biomass was elevated compared to the C. subvermispora inoculated biomass; however, treatment also induced additional chemical composition changes suggestive of depolymerization. Scanning electron microscope images reveal hyphae attached within cell lumen and suggest structural changes within P. chrysosporium treated corn stover after 60% moisture storage. These results highlight that fungal treatment approaches must balance loss of convertible material with the potential for reduction in recalcitrance. Techno-economic assessment (TEA) of fungal pretreatment in a short-term queuing system indicated the viability of this approach compared to conventional queuing operations. The total queuing system cost was estimated at $\$$1.65/tonne of biomass stored. After applying the credit of $\$$1.48/tonne from energy savings in the conversion phase using fungal pretreated biomass, the total system cost was $0.80 lower than traditional biomass queueing approach. While the TEA results suggested that treating biomass with C. subvermispora is the most economically viable storage method in the designed fungal-assisted queuing system, future research should focus on additional fungal depolymerization such as those observed in the P. chrysosporium inoculated biomass.

09 BIOMASS FUELS↗

Waste Glass Property Database and Data Qualification Plan

The U.S. Department of Energy vitrification facilities currently employ glass property-composition models to ensure processability of waste streams and acceptability of the final glass products. The efficiency (e.g., process flexibility, reduced down time, and reduced cost) of waste vitrification is directly tied to the size of the waste processing envelope. To increase the size of the processing envelope, a larger database was developed. The database will improve the prediction accuracy of glass properties, leading to higher waste loadings, higher waste throughput, broader process flexibility, and reduced mission life. Some of the data in this expanded database has insufficient quality assurance (QA) rigor for use in nuclear facility operation and glass qualification. A plan was developed to qualify high-value data under the appropriate QA rigor for use at the Hanford Waste Treatment and Immobilization Plant’s High-Level Waste (HLW) Facility. This qualification plan first compares the data coverage over the composition region of interest to Hanford HLW by property. Those studies that significantly improve the data coverage in the Hanford HLW glass composition region were prioritized for qualification activities. Qualification methods including QA equivalence, peer review, data corroboration, and confirmatory testing have been assigned to each high-priority study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low Carbon Technology Strategies: Primary School

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon primary schools within their existing building portfolios. Primary schools often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Barium stars as tracers of s -process nucleosynthesis in AGB stars

Barium (Ba) stars help to verify asymptotic giant branch (AGB) star nucleosynthesis models since they experienced pollution from an AGB binary companion and thus their spectra carry the signatures of the slow neutron capture process (s process). For a large number (180) of Ba stars, we searched for AGB stellar models that match the observed abundance patterns. We aim to uncover any systematic deviations of the sample abundances from the predictions of the nucleosynthesis models. We employed three machine learning algorithms as classifiers: a Random Forest method, developed for this work, and the two classifiers used in our previous study. Compared to that work, we also expanded our observational sample with 11 Ba stars available in the supersolar metallicity range. We studied the statistical behaviour of the different s-process elements in the observational sample to investigate if the AGB models systematically under- or overpredict the abundances observed in the Ba stars and show the results in the form of violin plots of the residuals between spectroscopic abundances and model predictions. We inspected the correlations between the observed [Fe/H], the s-process elemental abundances, and the residuals. We employed the [Zr/Fe] and [Nb/Fe] abundances as a thermometer to constrain the operational temperature that rules the production of these elements in the sample stars, assuming a steady-state s process. We also investigated the mass distribution of the identified polluter AGB stars and the behaviour of the δ parameter, which describes the fraction of accreted AGB material relative to the Ba star envelope. We find a significant trend in the residuals that implies an underproduction of the elements just after the first s-process peak (Nb, Mo, and Ru) in the models relative to the observations. This may originate from a neutron-capture process (e.g. the intermediate neutron-capture process, i process) not yet included in the AGB models of metallicity from solar to roughly 1/5 solar, corresponding to the range of the Ba stars. Correlations are found between the residuals of these peculiar elements, suggesting a common origin for the deviations from the models. In addition, there is a weak metallicity dependence of the residuals of these elements. The s-process temperatures derived with the [Zr/Fe] – [Nb/Fe] thermometer have an unrealistic value for the majority of our stars. The most likely explanation is that at least a fraction of these elements are not produced in a steady-state s process, and instead may be due to processes not included in the AGB models. The mass distribution of the identified models confirms that our sample of Ba stars was polluted by low-mass AGB stars (< 4 M ⊙ ). Most of the matching AGB models require low accreted mass, but a few systems with high accreted mass are needed to explain the observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Refinement of Salt Dissolution Inhibitor Requirements (Final Report)

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. It has been proposed that these corrosion control limits be revisited to evaluate the corrosion susceptibility of carbon steel in environments that more closely resemble current operating conditions at SRS. An experimental matrix was designed to evaluate the use of the pitting factor for supernate chemistries characteristic to SRS, particularly during the salt dissolution process. Two electrochemical methods were identified to determine the susceptibility of A537 and A285 low-carbon steels to pitting corrosion with this chemistry envelope at temperatures up to 75 °C. The predominant electrochemical test method was Cyclic Potentiodynamic Polarization (CPP) studies. Through CPP, the pitting factor was used, based on Hanford Site corrosion studies, to accurately identify pitting susceptibility within the compositional range studied with some conservatism. Additionally, sulfate was determined to have no statistically significant influence, at concentrations up to 0.6 M, on pitting behavior in more concentrated solutions where other aggressive species govern pitting susceptibility. Where CPP was inconclusive, Modified ASTM G192 was successfully used to evaluate pitting susceptibility conditions and allowed for a pass/fail result to be determined. In all cases, the pitting factor was determined to be applicable to the simulants tested, with this metric accurately predicting incidences in which pitting occurred. Based upon the findings in this work, a pitting factor of 1.2 is being proposed to build in a safety factor and remain consistent with the Hanford Site approach. Additionally, a minimum pH limit of 12 is proposed to ensure carbon steel passivity and localized corrosion the primary degradation mechanism. Susceptibility to SCC was evaluated using a reduced matrix of tests at 75 °C. No failures due SCC were observed at open circuit. In addition, tests polarized anodically by 200 mV only resulted in failures for trials with pitting factors less than 0.86. However, a test with a passing condition based upon the pitting factor metric (pitting factor = 1.40) did exhibit a failure with an applied potential of +300 mV vs. OCP. This result is contrary to the prediction based upon the pitting factor, however, a polarization of 300 mV, or even 200 mV, from open circuit is substantial. The relationship between these testing parameters and service environment/conditions and the desired level of conservatism in the metric should be further evaluated in the determination of the significance of this result. While the pitting factor accurately predicted susceptibility to SCC at temperatures up to 75 °C and with positive overpotentials up to 200 mV, the relatively small sample matrix and failure of a passing pitting factor with a 300 mV polarization resulted in an inconclusive determination of whether the pitting factor may be used for predicting susceptibility to SCC at temperatures between 50 °C and 75 °C. As such, additional testing is recommended to evaluate the validity of the pitting factor for SCC susceptibility prediction at temperatures between 50 °C and 75 °C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗