Search NASA⌕ Search

SEARCH · Search NASA

Results for “operating systems security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Secure, Scalable Control and Communications for Distributed PV

An increasing number of jurisdictions are adopting Distributed Energy Resource (DER) interconnection standards which require photovoltaic (PV) inverters, energy storage systems, and other DER to include interoperable grid-support functionality. These functions provide grid operators the nobs to support local and bulk power system operations with DER equipment, but the associated grid operator-to-DER communications networks must be deployed with appropriate cybersecurity features. In some situations, additional security features may prevent control system scalability or increase communication latencies and dropouts. These unintentional consequences of the security features would therefore hinder the ability of the grid operator to implement specific control algorithms. This project evaluated the tradeoffs between power system performance and cybersecurity metrics for several grid services.

14 SOLAR ENERGY↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

Secure Scalable Control and Communications for Distributed PV (Final Technical Report)

An increasing number of jurisdictions are adopting Distributed Energy Resource (DER) interconnection standards which require photovoltaic (PV) inverters, energy storage systems, and other DER to include interoperable grid-support functionality. These functions provide grid operators the nobs to support local and bulk power system operations with DER equipment, but the associated grid operator-to-DER communications networks must be deployed with appropriate cybersecurity features. In some situations, additional security features may prevent control system scalability or increase communication latencies and dropouts. These unintentional consequences of the security features would therefore hinder the ability of the grid operator to implement specific control algorithms. This project evaluated the tradeoffs between power system performance and cybersecurity metrics for several grid services. This was conducted in two parts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear Power Plant Simulation and Cybersecurity

Critical infrastructure protection is vital to the day-to-day operation of any country, and those systems need to be protected to the fullest extent possible. As with what was seen in Ukraine in late 2016, with the cyber attack on the power grid, these systems are susceptible to attacks that can cause serious damage, both physically and economically. This incident shut down the power grid for 6 hours, with nearly 80,000 people affected. Cyber security can be referred to as the protection of data and systems in networks, both wired and wireless, from unauthorized access or attack. In nuclear power plants, assessments of cyber security are critical to ensuring the safe and reliable operation of the systems used. According to the Nuclear Regulatory Commission (NRC), the purpose of cyber security assessments is to detect and then eliminate or mitigate vulnerabilities in the digital system that could be exploited either from outside or inside the digital system protected area. These cyber security assessments are essentially intended to reduce cyber security risk. The NRC refers to cyber security risk as the combination of the consequence to the nuclear power plant and the susceptibility of a digital system to internal and external cyber attack.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modelling and control coordination scheme of a wind‐to‐hydrogen set for future renewable‐based power systems

New challenges regarding system stability and efficiency arise when power systems operate with a high penetration level of inverter‐based renewable sources (IBRSs) and few synchronous generators. Since IBRSs have been on the rise, to secure the stable operation of future power systems, IBRSs will be required to support systems without having to rely on remaining synchronous generators. Also, to efficiently manage the uncertainty of renewable production, power‐to‐gas technology can provide the required flexibility. This study proposes modelling and a control coordination scheme (CCS) of a wind‐to‐hydrogen (W2H) set to optimise electricity production from a variable‐speed wind turbine generator (WTG) while helping balance between supply and demand in a system. To achieve this, a grid‐forming (GFM) inverter‐based WTG is modelled and a set of electrolyser and fuel cell is integrated at the DC circuit of a GFM‐WTG to be coordinated. Furthermore, the CCS offers an opportunity to reduce the investment cost for deploying a W2H set by utilising the control capabilities of a WTG and reducing the need for an additional device. The performance of the proposed W2H set with the CCS was verified considering the variations in system load and wind speed by using Power System Computer Aided Design (PSCAD)/ElectroMagnetic Transients including Direct Current (EMTDC).

Kim, Jinho↗

Parallel dispatch: a new paradigm of electrical power system dispatch

Modern power systems are evolving into sociotechnical systems with massive complexity, whose real-time operation and dispatch go beyond human capability. Thus, the need for developing and applying new intelligent power system dispatch tools are of great practical significance. In this paper, we introduce the overall business model of power system dispatch, the top level design approach of an intelligent dispatch system, and the parallel intelligent technology with its dispatch applications. We expect that a new dispatch paradigm, namely the parallel dispatch, can be established by incorporating various intelligent technologies, especially the parallel intelligent technology, to enable secure operation of complex power grids, extend system operators U+02BC capabilities, suggest optimal dispatch strategies, and to provide decision-making recommendations according to power system operational goals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Demonstration of a Security Core Component

In recent years, the convergence of a number of trends has resulted in Cyber Security becoming a much greater concern for electric utilities. A short list of these trends includes: · Industrial Control Systems (ICSs) have evolved from depending on proprietary hardware and operating software toward using standard off-the-shelf hardware and operating software. This has meant that these ICSs can no longer depend on “security through obscurity. · Similarly, these same systems have evolved toward using standard communications protocols, further reducing their ability to rely upon obscurity. · The rise of the Internet and the accompanying demand for more data about virtually everything has resulted in formerly isolated ICSs becoming at least partially accessible via Internet-connected networks. · “Cyber crime” has become commonplace, whether it be for industrial espionage, reconnaissance for a possible cyber attack, theft, or because some individual or group “has something to prove.” Electric utility system operators are experts at running the power grid. The reality is, especially at small and mid-sized utilities, these SCADA operators will by default be “on the front line” if and when a cyber attack occurs against their systems. These people are not computer software, networking, or cyber security experts, so they are ill-equipped to deal with a cyber security incident. Cyber Security Manager (CSM) was conceived, designed, and built so that it can be configured to know what a utility’s SCADA/EMS/DMS system looks like under normal conditions. To do this, CSM monitors log messages from any device that uses the syslog standard. It can also monitor a variety of statistics from the computers that make up the SCADA/EMS/DMS: outputs from host-based security tools, intrusion detection systems, SCADA alarms, and real-time SCADA values – even results from a SIEM (Security Information and Event Management) system. When the system deviates from “normal,” CSM can alert the operator in language that they understand that an incident may be occurring, provide actionable intelligence, and informing them what actions to take. These alarms may be viewed on CSM’s built-in user interface, sent to a SCADA alarm list, or communicated via email, phone, pager, or SMS message. In recognition of the fact that “real world” training for cyber security events is impractical, CSM has a built-in Operator Training Simulator capability. This can be used stand alone to create simulated event scenarios for training purposes. It may also be used in conjunction with the recipient’s SCADA/EMS/DMS Operator Training Simulator. In addition to providing cyber security situational awareness for electric utility operators, CSM also provides tools for analysts and support personnel; in fact, the majority of user interface displays are designed for use in analyzing current and past security events. CSM keeps security-related information in long-term storage, as well as writing any decisions it makes to a (syslog) log for use forensic or other post-event analysis.

Turke, Andy↗

AUTOMATIC GENERATION OF EVENT TREES AND FAULT TREES: A MODEL-BASED APPROACH

In the past few decades, increasing complexity in modern engineering systems has been driven by the integration of a large number of components and by the fact that the system operations involve many disciplines (e.g., thermal-hydraulics, plant operations, cyber-security). Current safety/reliability modeling approaches to such systems are labor intensive, difficult to learn, and rely heavily on simplistic Boolean logic to depict failure propagation and accident progression. While these methods serve well for simple systems (i.e., linear causal systems with limited small inter- and intra-system interactions), their results are difficult to verify when modeling complex systems (typically performed through the extensive use of modeling assumptions). The development of new methods is addressed to meet these challenges through a model-based system engineering (MBSE) lens. Under MBSE philosophy, every aspect of the system (form or function) is represented by a model that completely characterizes its architecture or behavior. MBSE approach greatly improves the management of design, analysis and verification of complex systems. An integration of Dynamic Probabilistic Risk Assessment (DPRA) methods with MBSE models is proposed to perform safety/reliability analyses of engineering systems. In particular, MBSE representation of the system (performed using Systems Modeling Language [SysML]) is coupled with DPRA methods to automatically generate event trees and fault trees.

97 - MATHEMATICS AND COMPUTING↗

SUPPORT OF NEW COMPUTER HARDWARE AT LUCH'S MC&A SYSTEM: PROBLEMS AND A SOLUTION

Abstract Microsoft Windows NT 4.0 operating system is the only software product certified in Russia for using in MC&A systems. In the paper a solution for allowing the installation of this outdated operating system on new computers is discussed. The solution has been successfully tested and has been in use at Luch's network since March 2008. Furthermore, it is being recommended for other Russian enterprises for the same purpose. Introduction Typically, the software part of a nuclear material control and accounting (MC&A) system consists of an operating system (OS), database management systems (DBMS), accounting program itself and database of nuclear materials. Russian regulations require the operating system and database for MC&A be certified for information security, and the whole system must pass an accreditation. Historically, the only certified operating system for MC&A still continues to be Microsoft Windows NT 4.0 Server/Workstation. Attempts to certify newer versions of Windows failed. Luch, like most other Russian sites, uses Microsoft Windows NT 4.0 and SQL Server 6.5. Luch's specialists have developed an application (LuchMAS) for accounting purposes. Starting from about 2004, some problems appeared in Luch's accounting system. They were related to the complexity of installing Windows NT 4.0 on new computers. At first, it was possible to solve the problem choosing computer equipment that is compatible with Windows NT 4.0 or selecting certain operating system settings. Over time, the problem worsened and now it is almost impossible to install Windows NT 4.0 on new computers. The reason is the lack of hardware drivers in the outdated operating system. The problem was serious enough that it could have affected the long-term sustainability of Luch's MC&A system if adequate alternate measures were not developed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diversity for safety and security of NPP I and C: Post NUREG/CR 7007 stage - 306

The paper summarizes authors' experience on diversity aspects of NPP I and C systems. It also discusses diversity analysis aspects according to NUREG/CR 7007 and other relevant standards. Diversity implementation challenges related to regulatory authorities, developers, auditors and operation engineers and managers are formulated and discussed. The paper presents a case study and developed tool to support diversity analysis and assessment using post NUREG/CR 7007 approach. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Video performance for high security applications.

The complexity of physical protection systems has increased to address modern threats to national security and emerging commercial technologies. A key element of modern physical protection systems is the data presented to the human operator used for rapid determination of the cause of an alarm, whether false (e.g., caused by an animal, debris, etc.) or real (e.g., a human adversary). Alarm assessment, the human validation of a sensor alarm, primarily relies on imaging technologies and video systems. Developing measures of effectiveness (MOE) that drive the design or evaluation of a video system or technology becomes a challenge, given the subjectivity of the application (e.g., alarm assessment). Sandia National Laboratories has conducted empirical analysis using field test data and mathematical models such as binomial distribution and Johnson target transfer functions to develop MOEs for video system technologies. Depending on the technology, the task of the security operator and the distance to the target, the Probability of Assessment (PAs) can be determined as a function of a variety of conditions or assumptions. PAs used as an MOE allows the systems engineer to conduct trade studies, make informed design decisions, or evaluate new higher-risk technologies. This paper outlines general video system design trade-offs, discusses ways video can be used to increase system performance and lists MOEs for video systems used in subjective applications such as alarm assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Deep End-to-End Model for Transient Stability Assessment With PMU Data

Accurate transient stability assessment (TSA) is a fundamental requirement for ensuring secure and stable operation of power systems. Tremendous efforts have been made to apply artificial intelligence approaches for TSA with phasor measurement unit data. However, many previous approaches may be failed to provide favorable accuracy due to the shallow architectures and error-prone hand-crafting features. This paper proposed a model for TSA, which is termed multi-branch stacked denoising autoencoder (MSDAE). This model is a unified framework integrating multiple stacked denoising autoencoders (SDAEs), one fusion layer, and one logistic regression (LR) layer. Initially, the SDAEs at the bottom of MSDAE extract features from multiple kinds of measurements respectively. Then, the extracted features are encoded into unified fusion features by the fusion layer. Finally, the LR layer performs TSA by using the fusion features. The depth of the architecture contributes to the remarkable ability for feature learning, while the width of the architecture (i.e., the multiple branches) enables MSDAE to deal with different kinds of measurements by a reasonable mechanism. In this way, MSDAE achieves feature extraction and classification intrinsically and simultaneously, namely, achieves TSA in an end-to-end manner. The results of experiments on IEEE 50-machine system demonstrate the superiority of the proposed model over the prior methods.

42 ENGINEERING↗

PMU Placement for Enhancing Dynamic Observability of a Power Grid

Power grids are operated in an increasingly complicated environment. However, operators lack effective and accurate tools for real-time monitoring and control of power systems. The U.S. Department of Energy, along with several utilities and system operators, is making a major $108 million investment in the Western Interconnection for phasor measurement unit (PMU) installation and phasor application development. This phasor measurement network opens up many opportunities for the estimation and prediction of power system states in real time, which enable operators to evaluate the system dynamic security in advance and allow them more time to respond to disturbances. Kalman filter based dynamic state estimation offers a solution suitable for this purpose. Our work indicates that the performance of Kalman filters in dynamic state estimation would degrade if PMU measurements cannot adequately capture the system dynamics. This paper develops a framework to identify how to place PMUs to improve dynamic observability of the power grid. Simulation results validate the concept, and the guidelines for PMU placement are derived.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interdisciplinary Approaches to Cybervulnerability Impact Assessment for Energy Critical Infrastructure

As energy infrastructure becomes more interconnected, understanding cybersecurity risks to production systems requires integrating operational and computer security knowledge. We interviewed 18 experts working in the field of energy critical infrastructure to compare what information they find necessary to assess the impact of computer vulnerabilities on energy operational technology. These experts came from two groups: 1) computer security experts and 2) energy sector operations experts. We find that both groups responded similarly for general categories of information and displayed knowledge about both domains, perhaps due to their interdisciplinary work at the same organization. Yet, their discussion of each group’s domain-specific training, motivations, and limitations, as well as their suggestions for collaboration across domains, highlighted how these two groups can work together to help each other secure the energy grid. Our findings inform the development of interdisciplinary security approaches in critical-infrastructure contexts.

97 MATHEMATICS AND COMPUTING↗

Towards improving software security by using simulation to inform requirements and conceptual design

We illustrate the use of modeling and simulation early in the system life-cycle to improve security and reduce costs. The models that we develop for this illustration are inspired by problems in reliability analysis and supervisory control, for which similar models are used to quantify failure probabilities and rates. In the context of security, we propose that models of this general type can be used to understand trades between risk and cost while writing system requirements and during conceptual design, and thereby significantly reduce the need for expensive security corrections after a system enters operation

97 MATHEMATICS AND COMPUTING↗

Decentralized Voltage optimization Method for Distribution Networks with Distributed PVs

In order to solve the voltage violations caused by high penetration distributed photovoltaics (PVs), this paper proposes a decentralized voltage optimization method for distribution networks. Through the optimal dispatch of distributed PVs and reactive power resources, it realizes the voltage security and economic operation of distribution systems and facilitates the integration of massive distributed PVs. The proposed method is inspired by the idea of locational marginal price (LMP) and feasible cutting plane. It separates the optimization of boundary bus voltage and power flow in adjacent regions and uses the interaction of boundary variables’ marginal prices to obtain the optimal solution. The effectiveness and accuracy of the proposed method are demonstrated via simulation test on a practical l0kV feeder in China.

Xue, Yaosuo↗

Interdisciplinary Approaches to Cyber-vulnerability Impact Assessment for Energy Critical Infrastructure

As energy infrastructure becomes more interconnected, understanding cybersecurity risks to production systems requires integrating operational and computer security knowledge. We interviewed 18 experts working in the field of energy critical infrastructure to compare what information they find necessary to assess the impact of computer vulnerabilities on energy operational technology. These experts came from two groups: 1) computer security experts and 2) energy sector operations experts. We find that both groups responded similarly for general categories of information and displayed knowledge about both domains, perhaps due to their interdisciplinary work at the same organization. Yet, we found notable differences in the details of their responses and in their stated perceptions of each group’s approaches to impact assessment. Their suggestions for collaboration across domains highlighted how these two groups can work together to help each other secure the energy grid. Our findings inform the development of interdisciplinary security approaches in critical-infrastructure contexts.

97 MATHEMATICS AND COMPUTING↗

Recommendations for Data-in-Transit Requirements for Securing DER Communications

With the adoption of Distributed Energy Resource (DER) interoperability standards, common communication protocols are now being deployed between power system operators and DER devices. In 2018, a revision to the US interconnection and interoperability standard, Institute of Electrical and Electronics Engineers (IEEE) Std. 1547, required DER equipment to have an IEEE 2030.5, IEEE 1815, or SunSpec Modbus communication exchange interface. This change supports the future transition to secure connection and exchange of information between the DER equipment and implementing parties, such as grid operators. Adoption of standardized communication protocols and associated information models is a critical step toward interoperability between power system operators and DER, such as photovoltaic (PV) and energy storage systems. However, security requirements for these standardized communication protocols are not comprehensive, resulting in non-standard and vendor-specific implementation that may leave DER equipment susceptible to cyberattacks. This paper examines the data-in-flight security requirements for standardized DER communication protocols, per IEEE 1547-2018 revision, as it relates to device authentication, key management, and encryption. The state of the art for these security features is also explored, addressing their impact on communication and performance of low-cost single board computers, which are typical of DER devices. In conclusion, a recommendation is provided to adopt a common set of communication requirements, which are intended to achieve interoperability and implement data security over DER network pathways, while ensuring reliable, secure, and real-time information delivery.

42 ENGINEERING↗