Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical clocks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Extracting Zero-Gravity Surface Figure of a Mirror

The technical innovation involves refinement of the classic optical technique of averaging surface measurements made in different orientations with respect to gravity, so the effects of gravity cancel in the averaged image. Particularly for large, thin mirrors subject to substantial deformation, the further requirement is that mount forces must also cancel when averaged over measurement orientations. The zerogravity surface figure of a mirror in a hexapod mount is obtained by analyzing the summation of mount forces in the frame of the optic as surface metrology is averaged over multiple clockings. This is illustrated with measurements taken from the Space Interferometry Mission (SIM) PT-Ml mirror for both twofold and threefold clocking. The positive results of these measurements and analyses indicate that, from this perspective, a lighter mirror could be used; that is, one might place less reliance on the damping effects of the elliptic partial differential equations that describe the propagation of forces through glass. The advantage over prior art is relaxing the need for an otherwise substantial thickness of glass that might be needed to ensure accurate metrology in the absence of a detailed understanding and analysis of the mount forces. The general insights developed here are new, and provide the basic design principles on which mirror mount geometry may be chosen.

Bloemhof, Eric E.↗

CubeSat Laser Infrared CrosslinK

The CubeSat Laser Infrared CrosslinK (CLICK) mission will demonstrate technology to advance the state of the art in intersatellite communications for small spacecraft. The primary objective of the mission is an on-orbit demonstration of full-duplex (send and receive) laser, also called optical communication, crosslink between two six-unit(6U) small satellites that range in distance between 15 and 360 miles (25 - 580 kilometers) apart at data rates greater than 20 megabits per second (Mbps). The mission will also demonstrate precision satellite-to-satellite clock synchronization and ranging at the 10 cm level. Miniaturized optical transceivers capable of both transmitting and receiving laser communications will form a communication crosslink between the two satellites with their alignment supported with a new fine pointing capability. The miniature optical transceivers are an improvement over radio frequency (RF) technology due to the power efficiency of lasercom high data rate transmission, which lessens the impact on the small platform's already severe constraints on size, weight and power.

Mayer, David J.↗

Optical Injection Locking of a VCSEL in an OEO

Optical injection locking has been demonstrated to be effective as a means of stabilizing the wavelength of light emitted by a vertical-cavity surface- emitting laser (VCSEL) that is an active element in the frequency-control loop of an opto-electronic oscillator (OEO) designed to implement an atomic clock based on an electromagnetically- induced-transparency resonance. This particular optical-injection- locking scheme is expected to enable the development of small, low-power, high-stability atomic clocks that would be suitable for use in applications involving precise navigation and/or communication. In one essential aspect of operation of an OEO of the type described above, a microwave modulation signal is coupled into the VCSEL. Heretofore, it has been well known that the wavelength of light emitted by a VCSEL depends on its temperature and drive current, necessitating thorough stabilization of these operational parameters. Recently, it was discovered that the wavelength also depends on the microwave power coupled into the VCSEL. Inasmuch as the microwave power circulating in the frequency-control loop is a dynamic frequency-control variable (and, hence, cannot be stabilized), there arises a need for another means of stabilizing the wavelength. The present optical-injection-locking scheme satisfies the need for a means to stabilize the wavelength against microwave- power fluctuations. It is also expected to afford stabilization against temperature and current fluctuations. In an experiment performed to demonstrate this scheme, wavelength locking was observed when about 200 W of the output power of a commercial tunable diode laser was injected into a commercial VCSEL, designed to operate in the wavelength range of 795+/-3 nm, that was generating about 200 microW of optical power. (The use of relatively high injection power levels is a usual practice in injection locking of VCSELs.)

Strekalov, Dmitry↗

NASA Tech Briefs, April 2005

Gas-Tolerant Device Senses Electrical Conductivity of Liquid Nanoactuators Based on Electrostatic Forces on Dielectrics Replaceable Microfluidic Cartridges for a PCR Biosensor CdZnTe Image Detectors for Hard-X-Ray Telescopes High-Aperture-Efficiency Horn Antenna Full-Circle Resolver-to-Linear-Analog Converter Continuous, Full-Circle Arctangent Circuit Advanced Three-Dimensional Display System Automatic Focus Adjustment of a Microscope Topics covered include: FastScript3D - A Companion to Java 3D; Generating Mosaics of Astronomical Images; Simulating Descent and Landing of a Spacecraft; Simulating Vibrations in a Complex Loaded Structure; Rover Sequencing and Visualization Program; Software Template for Instruction in Mathematics; Support for User Interfaces for Distributed Systems; Nanostructured MnO2-Based Cathodes for Li-Ion/Polymer Cells; Multi-Layer Laminated Thin Films for Inflatable Structures; Two-Step Laser Ranging for Precise Tracking of a Spacecraft; Growing Aligned Carbon Nanotubes for Interconnections in ICs; Multilayer Composite Pressure Vessels; Texturing Blood-Glucose-Monitoring Optics Using Oxygen Beams; Fault-Tolerant Heat Exchanger; Atomic Clock Based on Opto-Electronic Oscillator; Microfocus/Polycapillary-Optic Crystallographic X-Ray Sys; Depth-Penetrating Luminescence Thermography of Thermal- Barrier Coatings; One-Dimensional Photonic Crystal Superprisms; Measuring Low-Order Aberrations in a Segmented Telescope; Mapping From an Instrumented Glove to a Robot Hand; Application of the Hilbert-Huang Transform to Financial Data; Optimizing Parameters for Deep-Space Optical Communication; and Low-Shear Microencapsulation and Electrostatic Coating.

Source record↗

Entangling quantum logic gates in neutral atoms via the microwave-driven spin-flip blockade

The Rydberg dipole blockade has emerged as the standard mechanism to induce entanglement between neutral-atom qubits. In these protocols, laser fields that couple qubit states to Rydberg states are modulated to implement entangling gates. Here, in this study, we present an alternative protocol to implement entangling gates via Rydberg dressing and a microwave-field-driven spin-flip blockade. We consider the specific example of qubits encoded in the clock states of cesium. An auxiliary hyperfine state is optically dressed so that it acquires partial Rydberg character. It thus acts as a proxy Rydberg state, with a nonlinear light shift that plays the role of blockade strength. A microwave-frequency field coupling a qubit state to this dressed auxiliary state can be modulated to implement entangling gates. Logic gate protocols designed for the optical regime can be imported to this microwave regime, for which experimental control methods are more robust. We show that unlike the strong dipole-blockade regime usually employed in Rydberg experiments, going to a moderate-spin-flip-blockade regime results in faster gates and smaller Rydberg decay. We study various regimes of operations that can yield high-fidelity two-qubit entangling gates and characterize their analytical behavior. In addition to the inherent robustness of microwave control, we can design these gates to be more robust to laser amplitude and frequency noises at the cost of a small increase in Rydberg decay.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radio standards and measurements

Radio standards and frequency measurements - radio waves, atomic time standards, international time unit, and optical radio frequency measurement techniques

ATOMIC CLOCK↗

Interplanetary magnetic field changes and condensations in comet Halley's plasma tail

In a time-dependent three dimensional MHD simulation for cometary plasmas, Schmidt-Voigt (1989) could observe the formation of condensations in the plasma tail after a 90 degree change in the interplanetary magnetic field (IMF) sweeping over the comet. We investigated the IMF measurements of the Vega SC in the vicinity of the comet Halley for 90 degree changes in the clock angle and studied the relation between them and optical observations of condensations in the plasma tail. For the time interval 24 Feb. 86 to 14 Mar. 86, we could not find a correlation between such changes and the release of condensations from the cometary head.

Delva, Magda↗

Picosecond Clock Synchronization Across A 7-Node Metropolitan Scale Quantum Network

Quantum networking protocols relying on interference and precise time-of-flight measurements require high precision clock synchronization. This study describes the design, implementation, and characterization of two optical time transfer methods in a metropolitan-scale quantum networking research testbed. The first technique called active electronic stabilization (ELSTAB), was able to achieve sub-picosecond time deviation (TDEV) at integration times between 1 s and 105s over multiple different fiber lengths of both underground and aerial deployed fiber. The second technique, White Rabbit-Precision Time Protocol (WR-PTP), was able to achieve 10-picosecond TDEV’s over similar fiber lengths at comparable integration times. Environmental fluctuations affected the stability of clock synchronization over deployed fiber. These fluctuations resulted in path delay gradients, chromatic dispersion, polarization drift, and optical power variations. The results from this study will inform future work in the development of compensation methods essential for enabling experimental research in developing practical quantum networking protocols.

synchronization↗

Hg-201 (+) CO-Magnetometer for HG-199(+) Trapped Ion Space Atomic Clocks

Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations.

Burt, Eric A.↗

Optical and infrared masers

Ongoing research progress in the following areas is described: (1) tunable infrared light sources and applications; (2) precision frequency and wavelength measurements in the infrared with applications to atomic clocks; (3) zero-degree pulse propagation in resonant medium; (4) observation of Dicke superradiance in optically pumped HF gas; (5) unidirectional laser amplifier with built-in isolator; and (6) progress in infrared metal-to-metal point contact tunneling diodes.

Source record↗

A Dynamically-Reconfigurable Burst-Mode Link Using a Nanosecond Photonic Switch

Fast optical circuit switching has great potential to solve scaling issues with traditional packet-switch based networks and improve bandwidth and power efficiency in datacenter and high-performance computing applications. One difficultly in utilizing a fast optical switch is that the optical signal must be rapidly reacquired after each switching event so as to not significantly impact the overall throughput of the system. In this work we present a system-level integration of a nanosecond-scale $2 \times 2$ silicon photonic switch with a 25-Gbps burst-mode receiver that can lock in 31 ns. A novel FPGA-based control plane was used to generate test data, control the silicon photonic switch and burst-mode receiver, and measure bit errors at 12.5 and 20 Gbps. Error-free links (BER $< 10^{-12}$ ) with system-level reconfiguration times below 60 ns (at 20 Gbps) and 90 ns (at 12.5 Gbps) including bit- and frame-synchronization are demonstrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magneto-optical spectroscopy based on pump-probe strobe light

Here, we demonstrate a pump-probe strobe light spectroscopy for sensitive detection of magneto-optical dynamics in the context of hybrid magnonics. The technique uses a combinatorial microwave-optical pump-probe scheme, leveraging both the high-energy resolution of microwaves and high-efficiency detection using optical photons. In contrast with conventional stroboscopy using continuous-wave light, we apply microwave and optical pulses with varying pulse widths, and demonstrate magneto-optical detection of magnetization dynamics in Y 3 Fe 5 O 12 films. The detected magneto-optical signals depend strongly on the characteristics of both the microwave and the optical pulses, as well as their relative time delays. We show that good magneto-optical sensitivity and coherent stroboscopic character are maintained, even at a microwave pump pulse of 1.5 ns and an optical probe pulse of 80 ps, under a 7 MHz clock rate, corresponding to a pump-probe footprint of approximately 1% in one detection cycle. Our results show that time-dependent strobe light measurement of magnetization dynamics can be achieved in the gigahertz frequency range under a pump-probe detection scheme.

36 MATERIALS SCIENCE↗

Progress in developing a superconducting accelerator for efficient eBeam and X-ray production

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

43 PARTICLE ACCELERATORS↗

Timing and Synchronization in the LLRF systems of the Fermilab PIP-II Linac

The PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems for the 125 cavities which include a few normal conducting cavities in the warm front-end section, use a variety of LLRF hardware components and sub-systems that are part of the timing and synchronization system. This includes a master oscillator and phase averaging reference line, a beam pattern generator to enable beam transfer between non-harmonic RF systems and beam loading compensation systems synchronized to a start of beam trigger. The timing signals are based on a 650 MHz clock with manchester encoded event information and data provided over optical fiber. The timing and synchronization systems and their performance parameters will be described here.

Varghese, Philip↗

A synchronization technique for optical PPM signals

A technique for maintaining synchronization between optical PPM (pulse-position modulation) pulses and a receiver clock by means of a delay-tracking loop is described and analyzed. The tracking loop is driven by a doubly stochastic Poisson process that contains information about the location of the desired slot boundaries. The slot boundaries are subject to slowly varying random delays that are ultimately tracked by the loop. The concept of fractional rms delay error is introduced to quantify the effects of signal and background induced shot noise on the performance of the delay-tracking loop.

Vilnrotter, V. A.↗

A synchronization technique for optical PPM signals

A technique for maintaining synchronization between optical PPM (pulse-position modulation) pulses and a receiver clock by means of a delay-tracking loop is described and analyzed. The tracking loop is driven by a doubly stochastic Poisson process that contains information about the location of the desired slot boundaries. The slot boundaries are subject to slowly varying random delays that are ultimately tracked by the loop. The concept of fractional rms delay error is introduced to quantify the effects of signal and background induced shot noise on the performance of the delay-tracking loop.

Vilnrotter, V. A.↗

Control of a GaAs monolithic Ka-band phase shifter using a high-speed optical interconnect

The use of a high-speed optical interconnect in the control of a Ka-band GaAs monolithic phase shifter is described. A 16-b serial control signal was used to modulate the output of a laser transmitter, and the transmitted optical signal was detected and demultiplexed into 16 parallel electrical outputs using a high-speed hybrid GaAs optoelectronic integrated circuit. Four of the parallel output lines were interfaced to the 4-b phase shifter, and high-speed, optically controlled switching of the phase shifter was observed at clock frequencies to 30 MHz using an interferometric technique.

Bhasin, K. B.↗

Whispering Gallery Mode Resonators as Optical Reference Cavities

Highly stabilized lasers are an increasingly valuable tool for metrology. For many applications, however, existing Fabry Perot systems are too bulky and cumbersome. We are investigating the use of miniature monolithic whispering gallery mode resonators as reference cavities for laser stabilization. We seek to exploit the benefit of small size and vibration resistance by suppressing thermally induced frequency fluctuations. We have theoretically investigated the viability of using a thin-film coating to achieve temperature compensation. We have experimentally investigated an active temperature stabilization scheme based on birefringence in a crystalline resonator. We also report progress of laser locking to the resonators.

optical frequency↗