Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics for Data Quality

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is an astronomical project measuring millions of optical spectra to characterize Dark Energy. The survey has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs (Charge-Coupled Devices) which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and additional metrics for data quality and tools used for ICARUS monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variable Bragg x-ray beam splitters

Beam splitters are utilized in a variety of advanced x-ray instruments and are essential for extending quantum optics techniques to x rays. A new fabrication method has produced thinned Bragg diffracting silicon devices with variable reflectivity and transmission coefficients and negligible absorption losses. Diffraction measurements confirm that silicon continues to exhibit perfect crystal diffraction even for thicknesses below two microns. Devices are machined from standard wafers, with the thinned regions contained within the robust frame of an unperturbed crystal for ease of handling.

Powers, L. T. (ORCID:000900047481248X)↗

Coastal Cloud Chemistry during EPCAPE Field Campaign Report

For this campaign, Principal Investigator Markus Petters deployed a suite of instruments inside Lynn Russell’s container that was sited at Mt. Soledad during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) campaign. Funding for this activity was provided by National Science Foundation Award 2410536. The instrument rack (Figure 1) included a differential mobility analyzer, a condensation particle counter, a portable optical particle spectrometer, and a continuous flow diffusion cloud condensation nuclei counter (CCN). The instruments sampled from a counterflow virtual impactor (CVI) inlet and an isokinetic inlet. The measurements provided aerosol size distribution, size-resolved CCN activity, and denuded versus undenuded CCN activity of aerosols and cloud drop residuals.

54 ENVIRONMENTAL SCIENCES↗

Optically induced quantum transitions in direct probed mesoscopic NbSe 2 for prototypical bolometers

Superconducting transition-edge sensors (TES) have emerged as fascinating devices to detect broadband electromagnetic radiation with low thermal noise. The advent of metallic transition metal dichalcogenides, such as NbSe 2 , has also created an impetus to understand their low-temperature properties, including superconductivity. Interestingly, NbSe 2 -based sensor within the TES framework remains unexplored. In this work, direct-probed superconducting NbSe 2 absorbers led to a proof-of-concept demonstration for the transduction of incoming light to heat, where a thermodynamic superconducting phase transition in NbSe 2 was evident to switch it to the normal-state, when biased below its superconducting transition temperature. A wavelength-dependent response of its optical absorption properties was observed, based on the incident optical excitation source used. Furthermore, extensive optical characterization studies were conducted using Raman spectroscopy, where the in-plane and out-of-plane thermal conductivity was empirically determined. Our results open new possibilities for the use of NbSe 2 in superconducting radiation detectors, including in a TES framework

47 OTHER INSTRUMENTATION↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Overview of the Fiber System for the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is a revolutionary instrument designed for precise measurements of cosmic distances and the investigation of dark energy. DESI utilizes 5000 optical fibers to simultaneously measure the spectra of distant objects and aims to measure 40 million galaxies and quasars in a 5 yr survey. One of the critical challenges to DESI's success was ensuring that the fiber system was not only highly efficient but also delivered a highly stable beam enabling more reliable sky subtraction for measurements of faint objects. We achieved this stability by minimizing the stress on the fiber system during the manufacture and operation of the telescope and fiber positioning robots. We installed the DESI fiber system on the 4 m Mayall telescope with ≥99% of fibers intact, and the instrument has delivered superb optical performance throughout the initial years of the DESI survey, including ≥90% average throughput when injected with a focal ratio of ~f/3.9 as delivered by the primary focus corrector, excluding fiber absorption losses. The design of DESI required multiple innovations to achieve these requirements, such as cleaved fibers bonded with a UV-curing epoxy to glass ferrules in the focal plane and fusion splicing instead of physical connectors. In this paper, we describe the development, delivery, and installation of the fiber system, the innovations that made the state-of-the-art performance possible, and the key lessons learned that could benefit future projects.

79 ASTRONOMY AND ASTROPHYSICS↗

Controlling cantilevered adaptive X-ray mirrors

Modeling the behavior of a prototype cantilevered X-ray adaptive mirror (held from one end) demonstrates its potential for use on high-performance X-ray beamlines. Similar adaptive mirrors are used on X-ray beamlines to compensate optical aberrations, control wavefronts and tune mirror focal distances at will. Controlled by 1D arrays of piezoceramic actuators, these glancing-incidence mirrors can provide nanometre-scale surface shape adjustment capabilities. However, significant engineering challenges remain for mounting them with low distortion and low environmental sensitivity. Finite-element analysis is used to predict the micron-scale full actuation surface shape from each channel and then linear modeling is applied to investigate the mirrors' ability to reach target profiles. Using either uniform or arbitrary spatial weighting, actuator voltages are optimized using a Moore–Penrose matrix inverse, or pseudoinverse, revealing a spatial dependence on the shape fitting with increasing fidelity farther from the mount.

47 OTHER INSTRUMENTATION↗

Dopant, coating, and grating effects in silica optical fibers under extreme neutron irradiation

Radiation effects on fiber Bragg gratings (FBGs) have been studied but data gaps related to the effects of displacement damage resulting from high fast neutron fluence remain. In this work, Type-I and Type-II FBGs inscribed in optical fibers with various core dopants (Ge and F) and fiber coatings (acrylate, polyimide) were monitored in situ during 75 days of neutron irradiation to a peak fast (>0.1 MeV) neutron fluence of 3 X 10 21 n fast /cm 2 . Further, the reflected intensity of the Type-I FBGs inscribed in a Ge-doped core fiber decreased by > 30 dB within 7 h of irradiation (10 19 n fast /cm 2 ), whereas Type-II FBGs inscribed in a pure silica core fiber eventually approached >40 dB attenuation after accumulating a fast neutron fluence on the order of 10 20 n fast /cm 2 . Type-II FBGs inscribed in F-doped core fiber improved stability: the attenuation approached an equilibrium value in the range of 10 to 20 dB.

47 OTHER INSTRUMENTATION↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Optics and Systems Design of the Ring-to-Second Target Transport Beam-Line for the SNS Second Target Station

The Second Target Station (STS) project at the Spallation Neutron Source (SNS) is being developed to provide world-leading cold neutron brightness for next-generation neutron scattering experiments. The STS Accelerator Systems (AS) scope includes the design and implementation of the Ring-to-Second Target (RTST) proton beam transport line, which extracts 1.3 GeV proton beam pulses from the existing Ring-to-Beam Transport (RTBT) system and delivers them to the STS target. The RTST design emphasizes operational reliability [high reliability], low activation [minimum activation of components and the tunnel], maintainability, and compatibility with existing SNS infrastructure through extensive reuse of proven RTBT systems and components. The beamline includes a new extraction region, a transport lattice consisting of dipole, quadrupole, and corrector magnets, beam instrumentation systems, vacuum systems, personnel protection systems, and radiation shielding systems. Beam optics and particle tracking studies were performed using PyORBIT to validate extraction trajectories, beam transport, and target beam spot requirements [60–90 cm² beam spot area]. This paper presents the optics design philosophy, extraction system architecture, transport lattice design, instrumentation strategy, vacuum system approach, and radiation protection integration for the RTST beamline. Particle tracking simulations indicate successful beam transport without beam loss under nominal operating conditions. The RTST is designed to transport 1.3 GeV proton beam pulses at repetition rates up to 15 Hz, delivering nominal beam power of 700 kW to the Second Target Station.

Baron, Alex [ORNL]↗

Inverse design of photonic surfaces via multi fidelity ensemble framework and femtosecond laser processing

We demonstrate a multi-fidelity (MF) machine learning ensemble framework for the inverse design of photonic surfaces, trained on a dataset of 11,759 samples that we fabricate using high throughput femtosecond laser processing. The MF ensemble combines an initial low fidelity model for generating design solutions, with a high fidelity model that refines these solutions through local optimization. The combined MF ensemble can generate multiple disparate sets of laser-processing parameters that can each produce the same target input spectral emissivity with high accuracy (root mean squared errors < 2%). SHapley Additive exPlanations analysis shows transparent model interpretability of the complex relationship between laser parameters and spectral emissivity. Finally, the MF ensemble is experimentally validated by fabricating and evaluating photonic surface designs that it generates for improved efficiency energy harvesting devices. Our approach provides a powerful tool for advancing the inverse design of photonic surfaces in energy harvesting applications.

97 MATHEMATICS AND COMPUTING↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

CCN Measurements at Urban Site during CoURAGE

Cloud condensation nuclei (CCN) measurements were collected during CoURAGE from March - June 2025 at the BSEC urban atmospheric chemistry supersite (39.32057 N, 76.6246 W). CCN number concentrations (# cm-3) were obtained at a frequency of 1 second using a cloud condensation nuclei counter (CCN-100, Droplet Measurement Technologies). The CCN counter was operated in stepping mode, measuring CCN over a range of supersaturations from 0.2 to 1.0%. The settings of the instrument were set such that the supersaturation increased in increments of 0.2% up to the maximum supersaturation, and then decreased in increments of 0.2% down to the minimum supersaturation in a repeating cycle. The supersaturation of the instrument was calibrated weekly using ammonium sulfate. The weekly calibrated supersaturation values have been applied to the data. Data during transitions between supersaturation values were removed and replaced with a value of -999. Transitions are defined as the first 210 seconds after a new supersaturation value to ensure the instrument has stabilized following a change in supersaturation. Data were also flagged with a value of -999 if there were concerns with the function of the instrument, specifically the presence of alarm codes, fogging of the optical particle counter (1st stage monitor > 0.4 V), or a sheath to sample flow ratio outside the expected range (< 9 or > 11).

CCN number density↗

Dephasingless two-color terahertz generation

A laser pulse composed of a fundamental and an appropriately phased second harmonic can drive a time-dependent current of photoionized electrons that generates broadband THz radiation. Over the propagation distances relevant to many experiments, dispersion causes the relative phase between the harmonics to evolve. This “dephasing” slows the accumulation of THz energy and results in a multi-cycle THz pulse with significant angular dispersion. Here, we introduce a novel optical configuration that compensates the relative phase evolution, allowing for the formation of a half-cycle THz pulse with almost no angular dispersion. The configuration uses the spherical aberration of an axilens to map a prescribed radial phase variation in the near field to a desired longitudinal phase variation in the far field. Simulations that combine this configuration with an ultrashort flying focus demonstrate the formation of a half-cycle THz pulse with a controlled emission angle and 1/4 the angular divergence of the multi-cycle pulse created by a conventional optical configuration.

47 OTHER INSTRUMENTATION↗

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗