Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The X-Ray Surveyor Mission: A Concept Study

NASA's Chandra X-ray Observatory continues to provide an unparalleled means for exploring the high-energy universe. With its half-arcsecond angular resolution, Chandra studies have deepened our understanding of galaxy clusters, active galactic nuclei, galaxies, supernova remnants, neutron stars, black holes, and solar system objects. As we look beyond Chandra, it is clear that comparable or even better angular resolution with greatly increased photon throughput is essential to address ever more demanding science questions-such as the formation and growth of black hole seeds at very high redshifts; the emergence of the first galaxy groups; and details of feedback over a large range of scales from galaxies to galaxy clusters. Recently, we initiated a concept study for such a mission, dubbed X-ray Surveyor. The X-ray Surveyor strawman payload is comprised of a high-resolution mirror assembly and an instrument set, which may include an X-ray microcalorimeter, a high-definition imager, and a dispersive grating spectrometer and its readout. The mirror assembly will consist of highly nested, thin, grazing-incidence mirrors, for which a number of technical approaches are currently under development-including adjustable X-ray optics, differential deposition, and new polishing techniques applied to a variety of substrates. This study benefits from previous studies of large missions carried out over the past two decades and, in most areas, points to mission requirements no more stringent than those of Chandra.

Astronomy↗

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

Thermal response of large area high temperature superconducting YBaCuO infrared bolometer

Thermal analysis of large area high temperature superconducting infrared detector operating in the equilibrium mode (bolometer) was performed. An expression for the temperature coefficient beta=1/R(dR/dT) in terms of the thermal conductance and the thermal time constant of the detector were derived. A superconducting transition edge bolometer is a thermistor consisting of a thin film superconducting YBaCuO evaporated into a suitable thermally isolated substrate. The operating temperature of the bolometer is maintained close to the midpoint of the superconducting transition region where the resistance R has a maximum dynamic range. A detector with a strip configuration was analyzed and an expression for the temperature rise (delta T) above the ambient due to a uniform illumination with a source of power density P(sub i) was calculated. An expression for the thermal responsivity of the detector was derived using the thermal diffusion analysis with appropriate boundary conditions. It was found that the thermal responsibility depends upon the spatial modulation frequency and the angular frequency of the incoming radiation. The problem of the thermal cross talk between different detector elements was addressed. In the case of monolithic HTS detector array with a row of square elements of dimensions 2a and CCD or CID readout electronics the thermal spread function was derived for different spacing between elements. This analysis can be critical for future design and applications of large area focal plane arrays as broad band optical detectors made of granular thin films HTS YBaCuO.

Khalil, Ali E.↗

Large format imaging arrays for the Atacama Cosmology Telescope

We describe progress in the fabrication, characterization, and production of detector arrays for the Atacama Cosmology Telescope (ACT). The completed ACT instrument is specified to image simultaneously at 145, 225, and 265 GHz using three 32x32 filled arrays of superconducting transition edge sensors (TES) read out with time-division-multiplexed SQUID amplifiers. We present details of the pixel design and testing including the optimization of the electrical parameters for multiplexed readout. Using geometric noise suppression and careful tuning of operation temperature and device bias resistance, the excess noise in the TES devices is balanced with detector speed for interfacing with the ACT optics. The design also accounts for practical tolerances such as transition temperature gradients and scatter that occur in the production of multiple wafers to populate fully the kilopixel cameras. We have developed an implanted absorber layer compatible with our silicon-on-insulator process that allows for tunable optical resistance with requisite on-wafer uniformity and wafer-to-wafer reproducibility. Arrays of 32 elements have been tested in the laboratory environment including electrical, optical, and multiplexed performance. Given this pixel design, optical tests and modeling are used to predict the performance of the filled array under anticipated viewing conditions. Integration of the filled array of pixels with a tuned backshort and dielectric plate in front of the array maximize absorption and the focal plane and suppress reflections. A mechanical design for the build of the full structure is completed and we report on progress toward the construction of a prototype array for first light on the ACT.

Chervenak, J. A.↗

The Zwicky Transient Facility: System Overview, Performance, and First Results

The Zwicky Transient Facility (ZTF) is a new optical time-domain survey that uses the Palomar 48 inch Schmidt telescope. A custom-built wide-field camera provides a 47 deg ^(2) field of view and 8 s readout time, yielding more than an order of magnitude improvement in survey speed relative to its predecessor survey, the Palomar Transient Factory. We describe the design and implementation of the camera and observing system. The ZTF data system at the Infrared Processing and Analysis Center provides near-real-time reduction to identify moving and varying objects. We outline the analysis pipelines, data products, and associated archive. Finally, we present on-sky performance analysis and first scientific results from commissioning and the early survey. ZTF’s public alert stream will serve as a useful precursor for that of the Large Synoptic Survey Telescope.

Eric C. Bellm↗

(abstract) Pluto Integrated Camera-Spectrometer (PICS): a Low Mass, Low Power Instrument for Planetary Exploration

The concept we describe is an integrated instrument (a Pluto Integrated Camera-Spectrometer -- PICS) that will perform the functions of all three optical instruments required by the Pluto Fast Flyby Mission: the near-IR spectrometer, the camera, and the UV spectrometer. This integrated approach minimizes mass and power use. It also forced us early in the conceptual design to consider integrated observational sequences and integrated power management, thus ensuring compatible duty cycles (i.e., exposure times, readout rates) to meet the composite requirements for data collection, compression, and storage. Based on flight mission experience we believe that this integrated approach will result in substantial cost savings, both in reworking instrument designs during accommodation, as well as in sequence planning and integration. Finally, this integrated payload automatically yields a cohesive mission data set, optimized for correlative analysis. The presentation will provide details of the PICS instrument design and describe the fabrication and testing of the integrated SiC structure and optics at SSG Inc. Final integration and test plans for the prototype will also be described.

Pluto↗

Monolithic InSb imaging arrays with charge-coupled device /CCD/ readout

The paper demonstrates the detection of infrared radiation and signal readout on a monolithic InSb charge coupled infrared imaging device. The device is a 20-element linear imager with MOS detectors coupled to a four-phase, surface-channel, charge transfer structure. The charge transfer device is p-channel and has planar ion implanted diode structures for zero input and charge readout. Sensitivity measurements on the MOS infrared detectors were determined for the 20-element array. Data are presented on the operational characteristics of the 20-element linear imager under various conditions of electrical and optical inputs in both multiplexed and a time delay and integration (TDI) mode. Plans are discussed for a monolithic InSb 100-element linear imager and a 20 x 16 TDI linear imager.

Miller, W. E.↗

NASA Tech Briefs, March 2009

Topics covered include: Improved Instrument for Detecting Water and Ice in Soil; Real-Time Detection of Dust Devils from Pressure Readings; Determining Surface Roughness in Urban Areas Using Lidar Data; DSN Data Visualization Suite; Hamming and Accumulator Codes Concatenated with MPSK or QAM; Wide-Angle-Scanning Reflectarray Antennas Actuated by MEMS; Biasable Subharmonic Membrane Mixer for 520 to 600 GHz; Hardware Implementation of Serially Concatenated PPM Decoder; Symbolic Processing Combined with Model-Based Reasoning; Presentation Extensions of the SOAP; Spreadsheets for Analyzing and Optimizing Space Missions; Processing Ocean Images to Detect Large Drift Nets; Alternative Packaging for Back-Illuminated Imagers; Diamond Machining of an Off-Axis Biconic Aspherical Mirror; Laser Ablation Increases PEM/Catalyst Interfacial Area; Damage Detection and Self-Repair in Inflatable/Deployable Structures; Polyimide/Glass Composite High-Temperature Insulation; Nanocomposite Strain Gauges Having Small TCRs; Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling; Modeling Unsteady Cavitation and Dynamic Loads in Turbopumps; Continuous-Flow System Produces Medical-Grade Water; Discrimination of Spore-Forming Bacilli Using spoIVA; nBn Infrared Detector Containing Graded Absorption Layer; Atomic References for Measuring Small Accelerations; Ultra-Broad-Band Optical Parametric Amplifier or Oscillator; Particle-Image Velocimeter Having Large Depth of Field; Enhancing SERS by Means of Supramolecular Charge Transfer; Improving 3D Wavelet-Based Compression of Hyperspectral Images; Improved Signal Chains for Readout of CMOS Imagers; SOI CMOS Imager with Suppression of Cross-Talk; Error-Rate Bounds for Coded PPM on a Poisson Channel; Biomorphic Multi-Agent Architecture for Persistent Computing; and Using Covariance Analysis to Assess Pointing Performance.

Source record↗

Characterization of Pixelated Cadmium-Zinc-Telluride Detectors for Astrophysical Applications

Comparisons of charge sharing and charge loss measurements between two pixelated Cadmium-Zinc-Telluride (CdZnTe) detectors are discussed. These properties along with the detector geometry help to define the limiting energy resolution and spatial resolution of the detector in question. The first detector consists of a 1-mm-thick piece of CdZnTe sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). Signal readout is via discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). This crystal is bonded to a custom-built readout chip (ASIC) providing all front-end electronics to each of the 256 independent pixels. These detectors act as precursors to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation.

Gaskin, Jessica↗

Design, Fabrication, and Testing of a TiN Ti TiN Trilayer KID Array for 3mm CMB Observations

Kinetic inductance detectors (KIDs) are a promising technology for astronomical observations over a wide range of wavelengths in the mm and sub-mm regime. Simple fabrication, in as little as one lithographic layer, and passive frequency-domain multiplexing, with readout of up to 1000 pixels on a single line with a single cold amplifier, make KIDs an attractive solution for high-pixel-count detector arrays. We are developing an array that optimizes KIDs for optical frequencies near 100GHz to expand their usefulness in mm-wave applications, with a particular focus on CMBB-mode measurement efforts in association with the QUBIC telescope. We have designed, fabricated, and tested a 20-pixel prototype array using a simple quasi lumped microstrip design and pulsed DC reactive magnetron-sputtered TiNTiTiN trilayer resonators, optimized for detecting 100GHz (3mm) signals. Here we present a discussion of design considerations for the array, as well as preliminary detector characterization measurements and results from a study of TiN trilayer properties.

passive frequency-domain multiplexing↗

The prototype MOSAIC detector

The prototype of the MOSAIC (Mosaicked Optical Self-scanned Array Imaging Camera) system, a photon-counting detector designed for use in the far ultraviolet, is described. MOSAIC has a two-dimensional format of 2400 x 2400 pixels, and is easily expandable. Readout is accomplished electronically via charge-coupled devices, making possible remote observations. Preliminary results of computer simulations of the system are presented.

Weistrop, D.↗

Improved Ferroelectric Memories With Nondestructive Readout

Ferroelectric memories with enhanced photoresponse leading to improved nondestructive optoelectronic readout and lower power demand proposed. Memories improved versions of devices described in "Rapid, Nondestructive Readout From Ferroelectric Memory" (NPO-18551). In proposed application, array of nonvolatile ferroelectric memory cells fabricated by standard very-large-scale integrated-circuit techniques and flip-bonded onto similarly fabricated array of semiconductor lasers, {see "Optically Addressable, Ferroelectric Memory With NDRO" (NPO-18573)}.

Thakoor, Sarita↗

A CCD offset guider for the KAO

We describe a focal plane guider for the Kuiper Airborne Observatory which consists of a CCD camera interfaced to an AMIGA personal computer. The camera is made by Photometrics Ltd. and utilizes a Thomson 576 x 384 pixel CCD chip operated in Frame Transfer mode. Custom optics produce a scale of 2.4 arc-sec/pixel, yielding an approx. 12 ft. diameter field of view. Chopped images of stars with HST Guide Star Catalog magnitudes fainter than 14 have been used for guiding at readout rates greater than or equal to 0.5 Hz. The software includes automatic map generation, subframing and zooming, and correction for field rotation when two stars are in the field of view.

Colgan, Sean W. J.↗

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese↗

Euclid Near Infrared Spectro Photometer instrument concept and first test results obtained for different breadboards models at the end of phase C

The Euclid mission objective is to understand why the expansion of the Universe is accelerating through by mapping the geometry of the dark Universe by investigating the distance-redshift relationship and tracing the evolution of cosmic structures. The Euclid project is part of ESA's Cosmic Vision program with its launch planned for 2020 (ref [1]). The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments and is operating in the near-IR spectral region (900- 2000nm) as a photometer and spectrometer. The instrument is composed of: - a cold (135K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly (corrector and camera lens), a filter wheel mechanism, a grism wheel mechanism, a calibration unit and a thermal control system - a detection subsystem based on a mosaic of 16 HAWAII2RG cooled to 95K with their front-end readout electronic cooled to 140K, integrated on a mechanical focal plane structure made with molybdenum and aluminum. The detection subsystem is mounted on the optomechanical subsystem structure - a warm electronic subsystem (280K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data This presentation describes the architecture of the instrument at the end of the phase C (Detailed Design Review), the expected performance, the technological key challenges and preliminary test results obtained for different NISP subsystem breadboards and for the NISP Structural and Thermal model (STM).

Maciaszek, Thierry↗

Unfulfilled needs in IR astronomy focal-plane readout electronics

The NOAO's 8-m IR optimized telescope for Mauna Kea and NASA's SIRTF show that from 1 to 200 microns there are a number of unfulfilled needs in readout electronics. These include: extremely low readnoise, less than 10 electrons, stable operation at temperatures as low as 2 K, high well capacity, greater than 1 e 7 electrons, and integration times from 30 msec to over 100 sec. Sensors for adaptive optics systems are required with readnoise less than 10 electrons and response times of 30 msec. They should be highly efficient from 1 to 2.5 microns, but may have small formats. Ground-based imagers at these wavelengths need comparable readnoise but longer integration times, and the largest possible formats are essential. To achieve these goals improved cryogenic MOSFETS are essential and complete cryogenic CMOS circuits are highly desirable. Experimental cryoptimized MFETS promise to exceed the above noise requirements at 77 K and approach the needs at 2 K.

Low, Frank J.↗

The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR): A High Speed, Multispectral, Thermal Instrument Development in Support of HyspIRI-TIR

The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR) is being developed as part of the risk reduction activities associated with the Hyperspectral Infrared Imager (HyspIRI). The HyspIRI mission was recommended by the National Research Council Decadal Survey and includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. The HyspIRI TIR system will have 60m ground resolution, better than 200mK noise equivalent delta temperature (NEDT), 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. PHyTIR addresses the technology readiness level (TRL) of certain key subsystems of the TIR imager, primarily the detector assembly and scanning mechanism. PHyTIR will use Mercury Cadmium Telluride (MCT) technology at the focal plane and operate in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence allowing the high data rates needed for the 5 day repeat. PHyTIR will also demonstrate a newly developed interferometeric metrology system. This system will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing post-processing (e.g. geo-rectification computations).

National Research Council Decadal Survey↗

Reducing Stray Light To Characterize Nirspec Subsystems: The Focal Plane Array And Micro-Shutter Array

The James Webb Space Telescope (JWST) is an infrared, space-based telescope scheduled for launch in 2013. JWST includes four scientific instruments, including the Near Infrared Spectrometer (NIRSpec), which operates in the wavelength range from 0.6 to 5 microns. NASA/Goddard Space Flight Center (GSFC) is responsible for two NIRSpec subsystems: the detector subsystem, with its focal plane array (FPA), and the micro-shutter subsystem, with its micro-shutter array (MSA). The FPA is comprised of two side-by-side Rockwell Scientific HgCdTe 2kx2k detectors, with detectors and readout electronics optimized for low noise. The MSA is a GSFC developed micro-electro-mechanical system (MEMS) that serves as a programmable slit mask, allowing NIRSpec to obtain simultaneous spectra of >100 objects in a single field of view. We present the optical characterization test plan of the FPA. The test plan is driven by many requirements: cryogenic operating temperature, a flight-like beam shape, and multi-wavelength photon flux from 1 to 60,000 per second, thus low stray light is critical. We use commercial optical modeling software to predict stray light effects at the FPA. We also present the optical contrast test plan of the MSA. Since each individual shutter element operates in on/off fashion, the most important optical metric is contrast. The MSA structure is designed to minimize stray and scattered light, and the test setup reduces stray light such that the optical contrast requirement is met.

Connelly, Joseph A.↗