Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A physically unclonable function using NV diamond magnetometry and micromagnet arrays

A physically unclonable function (PUF) is an embedded hardware security measure that provides protection against counterfeiting. In this article, we present our work on using an array of randomly magnetized micrometer-sized ferromagnetic bars (micromagnets) as a PUF. We employ a 4μm thick surface layer of nitrogen-vacancy (NV) centers in diamond to image the magnetic field from each micromagnet in the array, after which we extract the magnetic polarity of each micromagnet using image analysis techniques. Finally, after evaluating the randomness of the micromagnet array PUF and the sensitivity of the NV readout, we conclude by discussing the possible future enhancements for improved security and magnetic readout.

Electromagnetism↗

Analog Signal Multiplexing System for the IOTA Proton Injector

he Fermilab Accelerator Science and Technology (FAST) Facility at FNAL is a dedicated research and development center focused on advancing particle accelerator technologies for future applications worldwide. Currently, a key objective of FAST Opera-tions is to commission the 2.5 MeV IOTA Proton Injec-tor (IPI) and enable proton injection into the Integrable Optics Test Accelerator (IOTA) storage ring. The low and medium-energy sections of the IPI include four frame-style dipole trims and two multi-function cor-rectors with independently controlled coils, requiring readout of 32 analog channels for current and voltage monitoring in total. To reduce cost and optimize rack space within the PLC-based control system, a 32-to-4 analog signal multiplexing system was designed and implemented. This system enables real-time readback of excitation parameters from all magnetic correctors. This paper presents the design, construction, implementation, and performance of the multiplexing system.

MacLean, Daniel R. [Fermilab] (ORCID:0000000210103↗

Operation of a Modular 3D-Pixelated Liquid Argon Time-Projection Chamber in a Neutrino Beam

The 2x2 Demonstrator, a prototype for the Deep Underground Neutrino Experiment (DUNE) liquid argon (LAr) Near Detector, was exposed to the Neutrinos from the Main Injector (NuMI) neutrino beam at Fermi National Accelerator Laboratory (Fermilab). This detector is a prototype of a new modular design for a liquid argon time-projection chamber (LArTPC), comprising a two-by-two array of four modules, each further segmented into two optically isolated LArTPCs. The 2x2 Demonstrator features a number of pioneering technologies, including a low-profile resistive field shell to establish drift fields, native 3D ionization pixelated imaging, and a high-coverage dielectric light readout system. The 2.4-tonne active mass detector is flanked upstream and downstream by supplemental solid-scintillator tracking planes, repurposed from the MINERvA experiment, which track ionizing particles exiting the argon volume. The antineutrino beam data collected by the detector over a 4.5 day period in 2024 include over 30,000 neutrino interactions in the LAr active volume—the first neutrino interactions reported by a DUNE detector prototype. During its physics-quality run, the 2x2 Demonstrator operated at a nominal drift field of 500 V/cm and maintained good LAr purity, with a stable electron lifetime of approximately 1.25 ms. This paper describes the detector and supporting systems, summarizes the installation and commissioning, and presents the initial validation of collected NuMI beam and off-beam self-triggers. In addition, it highlights observed interactions in the detector volume, including candidate muon antineutrino events.

47 OTHER INSTRUMENTATION↗

A Generic High Bandwidth Data Acquisition Card for Physics Experiments

In high energy physics and nuclear physics experiments particularly the ones based on particle accelerator, the data rate from the detector is usually in the order of Terabytes per second. This high throughput data from detector front-end electronics need to be transmitted to the back-end computing farm for high level event selection and building. A Data Acquisition (DAQ) system with features of high-density, scalable, easily upgradeable is crucial to simplify the readout architecture of whole experiment. This paper will introduce the design of a generic high bandwidth PCIe card which can be used as the important input output card in a scalable DAQ system. It can factorize front-end electronics from data handling, and reduce amount of custom hardware in favor of scalable detectorindependent commercial hardware and software. Besides the 48 channels of bidirectional high speed fiber optical links with frontends, it also supports to synchronize with the experiment timing system, and to fanout the clock and trigger information with a fixed latency to the front-end electronics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing Charge Dynamics in Diamond with an Individual Color Center

Control over the charge states of color centers in solids is necessary to fully utilize them in quantum technologies. However, the microscopic charge dynamics of deep defects in wide-band-gap semiconductors are complex, and much remains unknown. We utilize a single-shot charge-state readout of an individual nitrogen-vacancy (NV) center to probe the charge dynamics of the surrounding defects in diamond. We show that the NV center charge state can be converted through the capture of holes produced by optical illumination of defects many micrometers away. With this method, we study the optical charge conversion of silicon-vacancy (SiV) centers and provide evidence that the dark state of the SiV center under optical illumination is SiV 2– . These measurements illustrate that charge carrier generation, transport, and capture are important considerations in the design and implementation of quantum devices with color centers and provide a novel way to probe and control charge dynamics in diamond.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(Cd,Mg)Te crystals for picosecond-response optical-to-x-ray radiation detectors

We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.

Instruments & Instrumentation↗

Quantum electronics and optics at the interface of solid neon and superfluid helium

Here, we predict a new quantum electronic structure at the interface between two condensed phases of noble-gas elements: solid neon and superfluid helium. An excess electron injected onto this interface self-confines its wavefunction into a nanometric dome structure. Its size varies with pressure and optical transitions cover a broad mid-infrared spectrum. A collection of such electrons can form a classical Wigner crystal resembling a quantum-dot array on a triangular lattice. Under ultrafast laser illumination, this Wigner crystal can exhibit the quantum optical phenomenon of superradiance in the picosecond time scale. The ultralong spin-coherence time and micron-scale deterministic configurability allow the electrons in this system to serve as quantum information carriers. Their spin states can be controlled and readout by on-chip single-electron devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Complete time-resolved X-ray shape capability for a 10 MJ implosion: Milestone Report for MRT 8818

This report documents completion of MRT 8818, which established an upgraded equatorial time-resolved X-ray imaging capability for high-yield inertial confinement fusion experiments at the National Ignition Facility (NIF) using the equatorial Dilation X-ray Imager (DIXI). The need for this work arose from the sustained increase in fusion yield at NIF, which progressively intensified the neutron and gamma-ray environment experienced by target diagnostics. Although the existing polar imaging capability, particularly the Polar Dilation X-ray Imager (PDIXI), remained viable at high yields, the equatorial capability became inadequate because of radiation-induced failure of electronic readout hardware and increasing background levels that degraded image quality and ultimately caused saturation. The work performed under MRT 8818 addressed this limitation through a combination of hardware replacement, background characterization, and targeted mitigation. The DIXI backend was converted from CCD-based electronic readout to photographic film, and the principal sources of internally generated background were investigated using prior analyses, dedicated tests, and comparison with PDIXI performance on high-yield shots. This effort led to implementation of two principal improvements: a multilayer optical coating to suppress broadband radiation-induced background generated in the fiber-optic extension cylinder, and replacement of Kodak TMAX 400 film with Agfa Copex Rapid to reduce background generated directly in the film. These upgrades were completed in 2025 and performance assessment based on DT shot data since then, comparing with Polar DIXI and scaling of these experiments to 10 MJ indicates an expected signal-to-background ratio of approximately 34 for a single pinhole image, substantially exceeding the MRT 8818 completion criterion of SNR > 5.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Entangled Photon Pair Source Demonstrator Using the Quantum Instrumentation Control Kit System

Here, we report the first demonstration of using the Quantum Instrumentation and Control Kit (QICK) system on RFSoC-FPGA technology to drive the electro-optic intensity modulator that generate time-bin entangled photon pairs and to detect the photon signals. With the QICK system, we achieve high levels of performance metrics including coincidence-to-accidental ratio exceeding 150, and entanglement visibility exceeding 95%, consistent with performance metrics achieved using conventional waveform generators. We also demonstrate simultaneous detector readout using the digitization functional of QICK, achieving internal system synchronization time resolution of 3.2 ps. The work reported in this paper represents an explicit demonstration of the feasibility for replacing commercial waveform generators and time taggers with RFSoC-FPGA technology in the operation of a quantum network, representing a cost reduction of more than an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the temperature and humidity dependence of the SiPM characteristics

A miniature version of the ICAL experiment at the India-based Neutrino Observatory, the mini-ICALis in operation at the IICHEP, Madurai. The commissioning work of a Cosmic Muon Veto detector (CMVD)on top of the mini-ICAL is continued using extruded plastic scintillators with embeddedWLS fibers and the SiPM as a photo-transducer. The CMVD is being built to study thefeasibility of a cosmic muon veto for a shallow-depth neutrino experiment. The SiPM is calibratedusing an ultrafast LED driver andthe same calibration techniques will be used during the data taking period with a simplified LED in thesame readout PCB. An experimental setup wasdesigned to characterise the SiPMs in a temperature controlled environment. The readout electronicsinvolves trans-impedance amplifiers and a voltage followers of combined gain 1.24 mV/$\mu$A and adigital storage oscilloscope for the data collection with a minimal distortion of SiPM signal.Various characteristics of the Hamamatsu SiPM (S13360-2050VE), e.g. signal shape, optically correlatedand uncorrelated noise, recovery time etc were studied as a function of $V_{ov}$, number of photoelectrons,the ambient temperature and the humidity. This paper will cover the details of those results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate and confident prediction of electron beam longitudinal properties using spectral virtual diagnostics

Abstract Longitudinal phase space (LPS) provides a critical information about electron beam dynamics for various scientific applications. For example, it can give insight into the high-brightness X-ray radiation from a free electron laser. Existing diagnostics are invasive, and often times cannot operate at the required resolution. In this work we present a machine learning-based Virtual Diagnostic (VD) tool to accurately predict the LPS for every shot using spectral information collected non-destructively from the radiation of relativistic electron beam. We demonstrate the tool’s accuracy for three different case studies with experimental or simulated data. For each case, we introduce a method to increase the confidence in the VD tool. We anticipate that spectral VD would improve the setup and understanding of experimental configurations at DOE’s user facilities as well as data sorting and analysis. The spectral VD can provide confident knowledge of the longitudinal bunch properties at the next generation of high-repetition rate linear accelerators while reducing the load on data storage, readout and streaming requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗

Dual-rail encoding with superconducting cavities

The design of quantum hardware that reduces and mitigates errors is essential for practical quantum error correction (QEC) and useful quantum computation. To this end, we introduce the circuit-Quantum Electrodynamics (QED) dual-rail qubit in which our physical qubit is encoded in the single-photon subspace, { | 01 〉 , | 10 〉 } , of two superconducting microwave cavities. The dominant photon loss errors can be detected and converted into erasure errors, which are in general much easier to correct. In contrast to linear optics, a circuit-QED implementation of the dual-rail code offers unique capabilities. Using just one additional transmon ancilla per dual-rail qubit, we describe how to perform a gate-based set of universal operations that includes state preparation, logical readout, and parametrizable single and two-qubit gates. Moreover, first-order hardware errors in the cavities and the transmon can be detected and converted to erasure errors in all operations, leaving background Pauli errors that are orders of magnitude smaller. Hence, the dual-rail cavity qubit exhibits a favorable hierarchy of error rates and is expected to perform well below the relevant QEC thresholds with today’s coherence times.

97 MATHEMATICS AND COMPUTING↗

Spectrometer-free quantitative vapor sensing and classification via spatiotemporal imaging of porous silicon metasurfaces

Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.

Dash, Tomoshree [Clemson University]↗

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

Perturbative Diagonalization for Time-Dependent Strong Interactions

We present a systematic method to implement a perturbative Hamiltonian diagonalization based on the time-dependent Schrieffer-Wolff transformation. Applying our method to strong parametric interactions we show how, even in the dispersive regime, full Rabi model physics is essential to describe the dressed spectrum. Our results unveil several qualitatively different results, including realization of large energy-level shifts, tunable in magnitude and sign with the frequency and amplitude of the pump mediating the parametric interaction. Crucially, Bloch-Siegert shifts, typically thought to be important only in the ultrastrong or deep-strong coupling regimes, can be rendered large even for weak dispersive interactions to realize points of exact cancelation of dressed shifts (“blind spots”) at specific pump frequencies. The framework developed here highlights the rich physics accessible with time-dependent interactions and serves to significantly expand the functionalities for control and readout of strongly interacting quantum systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗