Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-0IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 pm (1000 -4000 cm-') to allow high-resolution, high-speed hyperspectral imaging applications [l-51. One application will be theremote sensing of the measurement of a large number of different atmospheric gases simultaneously in the sameairmass. Due to the use of a combination of birefiingent phase retarders and multiple achromatic phase switches toachieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventionalFourier transform spectrometer but without any moving parts. In this paper, the principle of operations, systemarchitecture and recent experimental progress will be presen.

solild state imaging Fourier tranform spectrometer↗

Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-O IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 micron (1000-4000/cm) to allow high-resolution, high-speed hyperspectral imaging applications. One application will be the remote sensing of the measurement of a large number of different atmospheric gases simultaneously in the same airmass. Due to the use of a combination of birefringent phase retarders and multiple achromatic phase switches to achieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventional Fourier transform spectrometer but without any moving parts. In this paper, the principle of operations, system architecture and recent experimental progress will be presented.

liquid crystal achromatic phase switch↗

Multilaser Herriott Cell for Planetary Tunable Laser Spectrometers

Geometric optics and matrix methods are used to mathematically model multilaser Herriott cells for tunable laser absorption spectrometers for planetary missions. The Herriott cells presented accommodate several laser sources that follow independent optical paths but probe a single gas cell. Strategically placed output holes located in the far mirrors of the Herriott cells reduce the size of the spectrometers. A four-channel Herriott cell configuration is presented for the specific application as the sample cell of the tunable laser spectrometer instrument selected for the sample analysis at Mars analytical suite on the 2009 Mars Science Laboratory mission.

continuous-wave↗

Optical processing of imaging spectrometer data

The data-processing problems associated with imaging spectrometer data are reviewed; new algorithms and optical processing solutions are advanced for this computationally intensive application. Optical decision net, directed graph, and neural net solutions are considered. Decision nets and mineral element determination of nonmixture data are emphasized here. A new Fisher/minimum-variance clustering algorithm is advanced, initialization using minimum-variance clustering is found to be preferred and fast. Tests on a 500-class problem show the excellent performance of this algorithm.

Liu, Shiaw-Dong↗

Particle Flux Measurements during TRACER (TRACER PFM) (Field Campaign Report)

The purpose of this campaign was to deploy an instrument payload collocated with a suite of in situ and remote-sensing aerosol instruments at the urban site at the La Porte, Texas Municipal Airport during the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) in Houston, Texas. The payload was designed to characterize the physicochemical properties, mixing state, and size-resolved vertical fluxes of aerosols. Deployed aerosol instruments associated with the flux measurements included three condensation particle counters (CPCs) with different lower cutoff diameters ( D > 2.5 nm, D > 10 nm, and D > 40 nm), a single-particle soot photometer (SP2) measuring refractory black carbon, and a portable optical particle spectrometer (POPS) measuring the optical size distribution (~180 nm < D < ~5000 nm). A 10-m flux tower hosted a sonic anemometer (SONIC) for vertical velocity measurements. In addition, a humidified tandem differential mobility analyzer (HTDMA) was deployed to measure the growth factors and hygroscopicity parameter of 15-50 nm-sized particles in order to constrain the composition of compounds responsible for modal aerosol growth during new particle formation/growth events. Finally, a radial differential mobility analyzer (RDMA) was deployed to extend the size distribution measurement to 5 nm.

54 ENVIRONMENTAL SCIENCES↗

Experimental Report: Multi-Instrument Comparison of AAF Size Distribution Instruments

Aerosols are particles suspended in the atmosphere, ranging in size from nanometers to micrometers. Their size distribution affects key atmospheric processes, including nucleation, coagulation, scavenging, activation, and radiative properties (Seinfeld and Pandis 2016). Aerosol size distribution is a critical parameter in atmospheric science, influencing processes such as cloud formation and radiative forcing. Accurate representation of aerosol size distributions is essential for understanding their impact on climate, air quality, and human health. However, aerosol size and composition vary significantly across time and space due to meteorological conditions and natural or anthropogenic sources. (Wu and Boor 2021). Various instruments are used to measure aerosol size distributions, each with distinct principles, advantages, and limitations. This report begins with an in-depth overview of aerosol size-distribution comparison studies, focusing on the passive cavity aerosol spectrometer probe (PCASP), portable optical particle spectrometer (POPS), ultra-high-sensitivity aerosol spectrometer (UHSAS), aerodynamic particle sizer (APS), and scanning mobility particle sizer (SMPS). All of these instruments are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), which commissioned this comparison and report. The report evaluates the strengths and weaknesses of these instruments, highlights their applications, and discusses efforts to merge data from multiple instruments for comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

JPL activities on development of acousto-optic tunable filter imaging spectrometer

Recent activities of JPL in the development of a new type of imaging spectrometers for earth observation and planetary exploration are reported. This instrument uses the acousto-optic tunable filter (AOTF) as high resolution and fast programmable bandpass filter. AOTF operates in the principle of acousto-optic interaction in an anisotropic medium. This filter can be tuned in sequential, random, and multiwavelength access modes, providing observational flexibility. The diffraction process in the filter generates two diffracted monochromatic beams with polarization orthogonal to each other, creating a unique capability to measure both polarimetric and spectral properties of the incoming light simultaneously with a single instrument. The device gives wide wavelength operations with reasonably large throughput. In addition, it is in a compact solid-state structure without moving parts, providing system reliability. These attractive features give promising opportunities to develop a new generation of airborne/spaceborne and ground, real-time, imaging spectrometer systems for remote sensing applications.

Cheng, Li-Jen↗

Use of the Airborne Visible/Infrared Imaging Spectrometer to Calibrate the Optical Sensor on Board the Japanese Earth Resources Satellite-1

In this paper, we describe an experiment to calibrate the Optical Sensor on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.

spaceborne↗

Use of the Airborne Visible/Infrared Imaging Spectrometer to calibrate the optical sensor on board the Japanese Earth Resources Satellite-1

We describe an experiment to calibrate the optical sensor (OPS) on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). On 27 Aug. 1992 both the OPS and AVIRIS acquired data concurrently over a calibration target on the surface of Rogers Dry Lake, California. The high spectral resolution measurements of AVIRIS have been convolved to the spectral response curves of the OPS. These data in conjunction with the corresponding OPS digitized numbers have been used to generate the radiometric calibration coefficients for the eight OPS bands. This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.

Green, Robert O.↗

Optical Design and Performance of the Ultra-Compact Imaging Spectrometer

We present the optical design and performance of the Ultra-Compact Imaging Spectrometer (UCIS) currently under development at Caltech's Jet Propulsion Laboratory. The new instrument demonstrates a low optical bench mass of less than 0.5 kg and compact size that enables Mars Rover or other in situ planetary applications. UCIS is a F/4, wide field (30deg) design, covering the spectral range 500-2600 nm and is enabled by a simple all aluminum two-mirror telescope and Offner spectrometer. We discuss here the optical design and alignment method that enables this compact and low mass imaging spectrometer and demonstrate successful spectrometer alignment with smile and keystone levels at 2-3% of a pixel width.

Imaging spectroscopy↗

Undersizing of aged African biomass burning aerosol by an ultra-high-sensitivity aerosol spectrometer

The ultra-high-sensitivity aerosol spectrometer (UHSAS) differs from most other optical particle spectrometers by using a high-power infrared (IR) laser to detect small particles and reduce the sizing ambiguity due to the non-monotonicity of scattering with particle size. During the NASA ORACLES project (ObseRvations of Aerosols above CLouds and their intEractionS) over the southeast Atlantic Ocean, the UHSAS clearly undersized particles in the biomass burning plume extending from southern Africa. Since the horizontal and vertical extent of the plume was vast, the NASA P-3B research aircraft often flew through a fairly uniform biomass burning plume for periods exceeding 30 min, sufficient time to explore the details of the UHSAS response by selecting single particle sizes with a differential mobility analyzer (DMA) and passing them to the UHSAS. This was essentially an in-flight calibration of the UHSAS using the particles of interest. Two modes of responses appeared. Most particles were undersized by moderate amounts, ranging from not at all for 70 nm aerosols to 15 % for 280 nm particles. Mie scattering calculations show that composition-dependent refractive index of the particles cannot explain the pattern. Heating of brown carbon or tarballs in the beam causing evaporation and shrinking of the particles is the most plausible explanation, though mis-sizing due to non-sphericity cannot be ruled out. A small fraction (10 %–30 %) of the particles were undersized by 25 % to 35 %. Those were apparently the particles containing refractory black carbon. Laboratory calibrations confirm that black carbon is drastically undersized by the UHSAS, because particles heat to their vaporization point and shrink. A simple empirical correction equation was implemented that dramatically improves agreement with DMA distributions between 100 and 500 nm. It raised the median particle diameter by 18 nm, from 163 to 181 nm, during the August 2017 deployment and by smaller amounts during deployments with less intense pollution. Calculated scattering from UHSAS size distributions increased by about 130 %, dramatically improving agreement with scattering measured by nephelometers. The correction is only valid in polluted instances; clean marine boundary layer and free troposphere aerosols behaved more like the calibration spheres. We were unable to directly test the correction between 500 and 1000 nm, though aerodynamic particle sizer (APS) data appear to show that the correction is poor at the largest diameters, which is no surprise as the composition of those particles is likely to be quite different than that of the accumulation mode. This adds to the evidence that UHSAS data must be treated cautiously whenever the aerosol may absorb infrared light. Similar corrections may be required whenever brown carbon aerosol is present.

54 ENVIRONMENTAL SCIENCES↗

A novel network-based approach to determining measurement representation error for model evaluation of aerosol microphysical properties

Atmospheric aerosol size and abundance influence radiative effects and climate change. To date, efforts to constrain global climate models’ radiative forcing with in situ aerosol observations have been hamstrung by uncertainty. One source of error, the regional “representation error,” arises when accurate but sparse single-point measurements of atmospheric aerosol distributions are compared with a model value, assuming that the single-point measurement is representative of the model domain. The Portable Optical Particle Spectrometer network in the Southern Great Plains (POPSnet-SGP) campaign has demonstrated that a network of nearly autonomous aerosol instruments operating at ambient temperature and relative humidity (with low measurement error) may be used to quantify measurement representation error and investigate the factors introducing heterogeneity in aerosol distributions across a rural, continental background region. Measurements were made using Portable Optical Particle Spectrometer (POPS) instruments at several sites for five months across the Department of Energy’s Aerosol Radiation Measurement Southern Great Plains (ARM-SGP) User Facility in the central USA. Measurement representation error decreased with longer averaging periods (20-40 % between 1 sec and 1 day), varied between sites by 10 – 20 % for aerosol concentration 140 – 2500 nm in diameter (N_140), and was higher for aerosols > 400 nm in diameter (N_400). Our measurements also show the influence of local meteorology on aerosol surface area (A_140) and size distributions: A_140 is positively correlated with wind speed and relative humidity, negatively correlated with precipitation, and lower given westerly winds. Based on this study, we conclude that the POPSnet approach provides considerably more insight into the spatial variability in the aerosol population that can be used to constrain climate models than would be available from similar networks of PM 2.5 monitors.

54 ENVIRONMENTAL SCIENCES↗

Electro-optical detector for use in a wide mass range mass spectrometer

An electro-optical detector is disclosed for use in a wide mass range mass spectrometer (MS), in the latter the focal plane is at or very near the exit end of the magnetic analyzer, so that a strong magnetic field of the order of 1000G or more is present at the focal plane location. The novel detector includes a microchannel electron multiplier array (MCA) which is positioned at the focal plane to convert ion beams which are focused by the MS at the focal plane into corresponding electron beams which are then accelerated to form visual images on a conductive phosphored surface. These visual images are then converted into images on the target of a vidicon camera or the like for electronic processing. Due to the strong magnetic field at the focal plane, in one embodiment of the invention, the MCA with front and back parallel ends is placed so that its front end forms an angle of not less than several degrees, preferably on the order of 10.degree.-20.degree., with respect to the focal plane, with the center line of the front end preferably located in the focal plane. In another embodiment the MCA is wedge-shaped, with its back end at an angle of about 10.degree.-20.degree. with respect to the front end. In this embodiment the MCA is placed so that its front end is located at the focal plane.

Giffin, Charles E.↗

The University of Colorado OSO-8 spectrometer experiment. I - Introduction and optical design considerations

The optical design of the high-resolution ultraviolet spectrometer prepared for the OSO-8 spacecraft is discussed. The instrument is a conventional 1 m Ebert-Fastie spectrometer fed by a Cassegrainian telescope. The instrument operates in the spectral range 1200-2000 A with spectral resolution of order 0.02 A. Spatial resolution is about 2.5 arcsec normal to the direction of the slit and is selectable from about 3 arcsec to 15 arcmin along the direction of the slit. Time resolution for the single spectrometer channel is selectable according to the needs of an individual observation and is limited to a maximum sampling rate of 40 ms per data point. The instrument is controlled by an internal general purpose computer.

Bruner, E. C., Jr.↗

Optical calibrator for TDL spectrometers

Two etalons and monochromator mode selector help calibrate spectrometer in selected laser mode. Technique accurately determines free spectral range of etalon. By establishing number of fringes between two modes, both of which have been calibrated with molecular line standards, one finds free spectral range with error inversely proportional to spectral interval between calibration points. Procedure establishes free spectral range of etalon without prior knowledge of its length or refractive index.

Jennings, D. E.↗

Acousto-optic tunable filter field spectrometer for validation of airborne and spaceborne imaging spectrometers

A new concept for a field portable spectrometer designed to meet the needs of the remote sensing community is presented. This instrument uses acoustooptic tunable filters (AOTFs) as wavelength sorters, allowing the design of a rugged, compact, light-weight tool that provides broad spectral coverage, great versatility, and ease of utilization. The spectrometer provides continuous spectral coverage from 0.4 to 2.5 microns with two channels defined by detector technology, while a visible channel covering the 0.4 to 1.0 micron spectral range uses silicon PV photodiodes. The short-wavelength IR channel covers the 0.9 to 2.5 micron special range with thermoelectrically cooled lead sulfide PC detectors.

Rider, David M.↗