A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

Polarizing 3 He via metastability exchange optical pumping using a 1.2 mbar sealed cell at magnetic fields up to 5 T

Here, we report high nuclear polarization of 1.2 mbar 3 He gas in a sealed cell in magnetic fields up to 5 T using Metastability Exchange Optical Pumping (MEOP). The creation of a highly polarized 3 He gas target for use in the 5 T field of Jefferson Lab’s CLAS12 spectrometer would enable new studies of spin-dependent asymmetries on the neutron. We describe a systematic study which was conducted for the first time up to the full 5 T field required for the final target design to evaluate the effects of discharge intensity, pump laser power, and optical pumping transition schemes on nuclear polarization and pumping rates. Steady-state polarizations up to 86% in magnetic fields between 2 and 5 T were achieved, with a discharge-on relaxation time of 898 s at 5 T. These results underscore the potential of MEOP for high-field applications in nuclear physics experiments.

3He polarization↗

Infrared Optical Constants from Pressed Pellets of Powders: I. Improved n and k Values of (NH4)(2)SO(4)from Single-Angle Reflectance

In combination with other parameters, the real, n(?), and imaginary, k(?), components of the complex refractive index, = n + ik, can be used to simulate the optical properties of a material in different forms, e.g. its infrared spectra. But obtaining reliable values of the optical constants n/k for solid materials is challenging due to the lack of optical quality specimens, usually crystals, large enough to measure. An alternative to crystals is to press the powder into a uniform disk. We have produced pellets from ammonium sulfate, (NH4)2SO4, powder and derived the pellets’ n and k values via single-angle reflectance using a specular reflectance device in combination with a Fourier transform infrared spectrometer. The single-angle technique measures amplitude of light reflected from the material as a function of wavelength over a wide spectral domain; the optical constants are determined from the reflectance data using the Kramers-Kronig relationship. We investigate several parameters associated with the pellets and pellet formation and their effects upon delivering the most reliable n/k values. Parameters studied include pellet diameter, mass and density (void space), drying, grinding, sieving and particle size in the pellet formation, as well as pressing pressure and duration. Of these parameters, using size-selected mixtures of dried, small (< 100 µm) particles and pressing at = 10 tons for at least 30 minutes were found key to forming highly reflective samples. Comparison to two sets of previous literature n(?) and k(?) values obtained from crystalline (NH4)2SO4 both as crystal reflectance as well as extinction spectra of aerosols measured in a flow tube show reasonable agreement, but suggests the present values, as confirmed from two independent techniques, represent a substantial improvement for n/k values for (NH4)2SO4, also demonstrating promise to measure the optical constants of other materials.

Optical constants, index of refraction, single-ang↗

Fabrication of metal-organic framework thin films for luminescent sensing applications

Metal−organic frameworks (MOFs) have emerged as an exciting material class due to their nearly infinite design space: an inexhaustible combination of metal centers, organic linkers, and reaction conditions may be leveraged to obtained desired optical, physical, and chemical properties. This rich synthetic diversity enables properties such as pore dimensions and functionality to be rationally tailored for highly selective and sensitive detection of target analytes. Luminescent MOF-based sensors in particular offer advantages including low cost, portability, and ease-of-use. Often, performance is maximized by utilizing the luminescent MOF in thin film form, for example by integrating the film onto an optical fiber, yet the synthesis of high-quality MOF thin films often requires tedious, expensive, and/or slow approaches. Here, we demonstrate a rapid, simple strategy for growing copper MOFs using metal oxide templates; the concept is first demonstrated with a well-studied system, copper-1,3,5-benznetricarboxylate (Cu-BTC). Variables such as the choice of solvent, pH, and the choice of the copper salt anion all govern thin film quality. We then extend this method to synthesize a solvent and metal-responsive copper MOF that is particularly effective at detecting aluminum, an economically critical metal, at trace concentrations using a fully portable luminescence spectrometer. Taken together, this work demonstrates a convenient, versatile, and sustainable method for developing high quality MOF thin film-based optical sensors.

Crawford, Scott↗

The Multiplanet System TOI-421: A Warm Neptune and a Super Puffy Mini-Neptune Transiting a G9 V Star in a Visual Binary

We report the discovery of a warm Neptune and a hot sub-Neptune transiting TOI-421 (BD-14 1137, TIC 94986319), a bright (V = 9.9) G9 dwarf star in a visual binary system observed by the Transiting Exoplanet Survey Satellite (TESS) space mission in Sectors 5 and 6. We performed ground-based follow-up observations—comprised of Las Cumbres Observatory Global Telescope transit photometry, NIRC2 adaptive optics imaging, and FIbre-fed Echellé Spectrograph, CORALIE, High Accuracy Radial velocity Planet Searcher, High Resolution Échelle Spectrometer, and Planet Finder Spectrograph high-precision Doppler measurements—and confirmed the planetary nature of the 16 day transiting candidate announced by the TESS team. We discovered an additional radial velocity signal with a period of five days induced by the presence of a second planet in the system, which we also found to transit its host star. We found that the inner mini-Neptune, TOI-421 b, has an orbital period of P{sub b} = 5.19672 ± 0.00049 days, a mass of M{sub b} = 7.17 ± 0.66 M{sub ⊕}, and a radius of R{sub b} = 2.68{sub −0.18}{sup +0.19} R{sub ⊕}, whereas the outer warm Neptune, TOI-421 c, has a period of P{sub c} = 16.06819 ± 0.00035 days, a mass of M{sub c} = 16.42{sub −1.04}{sup +1.06} M{sub ⊕}, a radius of R{sub c} = 5.09{sub −0.15}{sup +0.16} R{sub ⊕}, and a density of ρ{sub c} = 0.685{sub −0.072}{sup +0.080} g cm{sup −3}. With its characteristics, the outer planet (ρ{sub c} = 0.685{sub −0.072}{sup +0.080} g cm{sup −3}) is placed in the intriguing class of the super-puffy mini-Neptunes. TOI-421 b and TOI-421 c are found to be well-suited for atmospheric characterization. Our atmospheric simulations predict significant Lyα transit absorption, due to strong hydrogen escape in both planets, as well as the presence of detectable CH{sub 4} in the atmosphere of TOI-421 c if equilibrium chemistry is assumed.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray spectrometer

An x-ray spectrometer includes: an x-ray plasma source that produces first x-rays; an x-ray optic in optical communication with the x-ray plasma source and that: receives the first x-rays from the x-ray plasma source; focuses the first x-rays to produce second x-rays; and communicates the second x-rays to a sample that produces product x-rays in response to receipt of the second x-rays and second light; and a microcalorimeter array detector in optical communication with the sample and that receives the product x-rays from the sample.

Ullom, Joel↗

Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

Proton reconstruction with the CMS-TOTEM Precision Proton Spectrometer

The Precision Proton Spectrometer (PPS) of the CMS and TOTEM experiments collected 107.7 fb$^{-1}$ in proton-proton (pp) collisions at the LHC at 13 TeV (Run 2). This paper describes the key features of the PPS alignment and optics calibrations, the proton reconstruction procedure, as well as the detector efficiency and the performance of the PPS simulation. The reconstruction and simulation are validated using a sample of (semi)exclusive dilepton events. The performance of PPS has proven the feasibility of continuously operating a near-beam proton spectrometer at a high luminosity hadron collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct reconstruction of isolated XUV or soft x-ray attosecond pulses from high-harmonic generation streaking spectra

Characterization of an isolated attosecond pulse (IAP) in the extreme ultraviolet (XUV) or soft x-ray (SXR) region is essential for its applications. Here we propose to retrieve an IAP in the time domain directly through the modulation of high-harmonic generation (HHG) spectra in the presence of a time-delayed intense few-cycle infrared or mid-infrared laser. The retrieval algorithm is derived based on the strong-field approximation and an extended quantitative rescattering model. We show that both isolated XUV pulses with a narrow spectral bandwidth and isolated SXR pulses with a broad bandwidth can be well characterized through the HHG streaking spectra. Such an all-optical method for characterizing the IAP differs from the commonly used approach based on the streaked photoelectron spectra that would require electron spectrometers. We check the robustness of the retrieval method by changing the dressing laser or by adjusting the steps of time delay. We also show that the XUV pulse can be accurately retrieved by treating the HHG streaking spectra calculated from solving the time-dependent Schrödinger equation for single atoms as the ‘experimental’ data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Source apportionment of soot particles and aqueous-phase processing of black carbon coatings in an urban environment

Abstract. The impacts of soot particles on climate and human health depend on the concentration of black carbon (BC) as well as the thickness and composition of the coating material, i.e., organic and inorganic compounds internally mixed with BC. In this study, the size-resolved chemical composition of BC-containing aerosol was measured using a high-resolution soot particle aerosol mass spectrometer (SP-AMS) during wintertime in Fresno, California, a location influenced by abundant combustion emissions and frequent fog events. Concurrently, particle optical properties were measured to investigate the BC absorption enhancement. Positive matrix factorization (PMF) analysis was performed on the SP-AMS mass spectral measurements to explore the sources of soot particles and the atmospheric processes affecting the properties of BC coatings. The analysis revealed that residential woodburning and traffic are the dominant sources of soot particles. Alongside primary soot particles originating from biomass burning (BBOABC) and vehicles (HOABC) two distinct types of processed BC-containing aerosol were identified: fog-related oxidized organic aerosol (FOOABC) and winter-background OOABC (WOOABC). Both types of OOABC showed evidence of having undergone aqueous processing, albeit with differences. The concentration of FOOABC was substantially elevated during fog events, indicating the formation of aqueous secondary organic aerosol (aqSOA) within fog droplets. On the other hand, WOOABC was present at a relatively consistent concentration throughout the winter and was likely related to the formation of secondary organic aerosol (SOA) in both the gas phase and aerosol liquid water. By comparing the chemical properties and temporal variations in FOOABC and WOOABC, we gain insights into the key aging processes of BC aerosol. It was found that aqueous-phase reactions facilitated by fog droplets had a significant impact on the thickness and chemical composition of BC coatings, thereby affecting the light absorption and hygroscopic properties of soot particles. These findings underscore the important role of chemical reactions occurring within clouds and fogs and influencing the climate forcing of BC aerosol in the atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Compiled TBS data from Oliktok Point from ICARUS, AVPOP, and POPEYE

The dataset encompasses QA/QC TBS data, including TBS altitude, atmospheric pressure, dew point, POPs number concentrations and mean aerosol size, relative humidity, temperature, equivalent potential temperature, equivalent temperature, and date and time. These data are provided per day for at least one TBS flight. Supporting data from the AMF3 aligned with the timestamps of the TBS data include cloud base distance from TBS, if the time corresponds to cloud base transit of the TBS, surface-based pressure, surface-based precipitation rate, surface-based UHSAS data, ceilometer cloud base height, KAZR cloud top height, and MWR liquid water content. Both POPS and UHSAS aerosol number concentrations are provided as: (1) absolute (i.e. concentrations for each instrument's total size range) and (2) the overlapping size range (i.e. the same size bins for both instruments).

54 ENVIRONMENTAL SCIENCES↗

A super-resolution technique to analyze single-crystal inelastic neutron scattering measurements using direct-geometry chopper spectrometers

Direct-geometry time-of-flight chopper neutron spectroscopy is instrumental in studying dynamics in liquid, powder, and single crystal systems. We report here that real-space techniques in optical imagery can be adapted to obtain reciprocal-space super resolution dispersion for phonon or magnetic excitations from single-crystal neutron spectroscopy measurements. The procedure to reconstruct super-resolution energy dispersion of excitations relies on an accurate determination of the momentum and energy-dependent point spread function and a dispersion correction technique inspired by an image disparity calculation technique commonly used in stereo imaging. Here by, applying these methods to spinwave dispersion data from a virtual neutron experiment demonstrates ~5-fold improvement over nominal energy resolution.

47 OTHER INSTRUMENTATION↗

Optical Characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019

The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale cosmic microwave background (CMB) polarization from the South Pole in search of a primordial B-mode signature. This B-mode signal arises from primordial gravitational waves interacting with the CMB and has amplitude parametrized by the tensor-to-scalar ratio r. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier transform spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on r induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Field Validation of Cloud Properties Sensor Field Campaign Report

The purpose of this campaign is to deploy Aerodyne Research Inc.’s extended wavelength cloud optical properties sensor (TWST-EN) in an operationally relevant environment with co-located, validated sensors. The Atmospheric Radiation Measurement (ARM) user facility’s Southern Great Plains (SGP) observatory is ideal for this deployment because of the variety of operational sensors that can measure some of the same cloud properties using different modalities. While cloud property sensors have long existed, they tend to be costly to produce and maintain. Our sensor measures absolute spectral radiance in the two bands and will retrieve cloud optical depth (COD), droplet effective radius, and thermodynamic phase. Our prototype is built predominantly from off-the-shelf components and uses uncooled spectrometers. A lower-cost, easy-to-use sensor such as this could allow deployment at many more sites for greater spatial coverage. Analysis and retrieval algorithm development using the data from this deployment has been a central technical objective of our U.S. Department of Energy Small Business Innovative Research (SBIR) Phase 2 contract (DE-SC0020473: Low-Cost Shortwave Spectroradiometer for Retrieval of Cloud Properties).

54 ENVIRONMENTAL SCIENCES↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Design of a new charge exchange recombination spectroscopy diagnostic for impurity transport experiments at Wendelstein 7-X

In this study, we present the design of a new charge exchange recombination spectroscopy (CXRS) system for Wendelstein 7-X (W7-X), which aims at measuring line radiation from highly ionized iron impurities after laser blow off injections over transport timescales. New fiber bundles with a core diameter of 600 µm have been added to one of the existing optical systems at W7-X used for CXRS. The fibers direct collected light to five newly developed single channel high frame rate F/2.8 spectrometers. The new custom-made spectrometers are built using entirely off-the-shelf and 3D printed components, and employ a round-to-linear fiber bundle, instead of an entrance slit, to maximize light throughput. The detector is an ultra-low readout noise EM-CCD camera capable of frame rates of up to 10 000 fps for about 500 consecutive frames when operated using a single readout channel. Such high frame rates will enable the study of inward convection of injected impurities. An initial sensitivity study is performed using a newly developed Markov chain Monte Carlo approach based on the pySTRAHL impurity transport code. This study indicates that, with the addition of the new CX diagnostic, impurity convection velocities can be inferred.

Instruments & Instrumentation↗

Trigonal Bipyramidal V 3+ Complex as an Optically Addressable Molecular Qubit Candidate

Synthetic chemistry enables a bottom-up approach to quantum information science, where atoms can be deterministically positioned in a quantum bit or qubit. Two key requirements to realize quantum technologies are qubit initialization and read-out. By imbuing molecular spins with optical initialization and readout mechanisms, analogous to solid-state defects, molecules could be integrated into existing quantum infrastructure. To mimic the electronic structure of optically addressable defect sites, we designed the spin-triplet, V 3+ complex, (C 6 F 5 ) 3 trenVCN t Bu (1).We measured the static spin properties as well as the spin coherence time of1demonstrating coherent control of this spin qubit with a 240 GHz electron paramagnetic resonance spectrometer powered by a free electron laser. We found that1exhibited narrow, near-infrared photoluminescence (PL) from a spin-singlet excited state. Using variable magnetic field PL spectroscopy, we resolved emission into each of the ground-state spin sublevels, a crucial component for spin-selective optical initialization and readout. This work demonstrates that trigonally symmetric, heteroleptic V 3+ complexes are candidates for optical spin addressability.

30 DIRECT ENERGY CONVERSION↗