Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygen monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

NASA Tech Briefs, July 2011

Topics covered include: 1) Collaborative Clustering for Sensor Networks; 2) Teleoperated Marsupial Mobile Sensor Platform Pair for Telepresence Insertion Into Challenging Structures; 3) Automated Verification of Spatial Resolution in Remotely Sensed Imagery; 4) Electrical Connector Mechanical Seating Sensor; 5) In Situ Aerosol Detector; 6) Multi-Parameter Aerosol Scattering Sensor; 7) MOSFET Switching Circuit Protects Shape Memory Alloy Actuators; 8) Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition; 9) Circuit for Communication Over Power Lines; 10) High-Efficiency Ka-Band Waveguide Two-Way Asymmetric Power Combiner; 11) 10-100 Gbps Offload NIC for WAN, NLR, and Grid Computing; 12) Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices; 13) Flight Planning in the Cloud; 14) MPS Editor; 15) Object-Oriented Multi Disciplinary Design, Analysis, and Optimization Tool; 16) Cryogenic-Compatible Winchester Connector Mount and Retaining System for Composite Tubes; 17) Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy; 18) Planar Rotary Piezoelectric Motor Using Ultrasonic Horns; 19) Self-Rupturing Hermetic Valve; 20) Explosive Bolt Dual-Initiated from One Side; 21) Dampers for Stationary Labyrinth Seals; 22) Two-Arm Flexible Thermal Strap; 23) Carbon Dioxide Removal via Passive Thermal Approaches; 24) Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring; 25) Pressure Shell Approach to Integrated Environmental Protection; 26) Image Quality Indicator for Infrared Inspections; 27) Micro-Slit Collimators for X-Ray/Gamma-Ray Imaging; 28) Scatterometer-Calibrated Stability Verification Method; 29) Test Port for Fiber-Optic-Coupled Laser Altimeter; 30) Phase Retrieval System for Assessing Diamond Turning and Optical Surface Defects; 31) Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror; 32) Generic, Extensible, Configurable Push-Pull Framework for Large-Scale Science Missions; 33) Dynamic Loads Generation for Multi-Point Vibration Excitation Problems; 34) Optimal Control via Self-Generated Stochasticity; 35) Space-Time Localization of Plasma Turbulence Using Multiple Spacecraft Radio Links; 36) Surface Contact Model for Comets and Asteroids; 37) Dust Mitigation Vehicle; 38) Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component; 39) SpaceCube Demonstration Platform; 40) Aperture Mask for Unambiguous Parity Determination in Long Wavelength Imagers; 41) Spaceflight Ka-Band High-Rate Radiation-Hard Modulator; 42) Enabling Disabled Persons to Gain Access to Digital Media; 43) Cytometer on a Chip; 44) Principles, Techniques, and Applications of Tissue Microfluidics; and 45) Two-Stage Winch for Kites and Tethered Balloons or Blimps.

Source record↗

Manipulation of Microenvironment with a Built-in Electrochemical Actuator in Proximity of a Dissolved Oxygen Microsensor

Abstract - Biochemical sensors for continuous monitoring require dependable periodic self- diagnosis with acceptable simplicity to check its functionality during operation. An in situ self- diagnostic technique for a dissolved oxygen microsensor is proposed in an effort to devise an intelligent microsensor system with an integrated electrochemical actuation electrode. With a built- in platinum microelectrode that surrounds the microsensor, two kinds of microenvironments, called the oxygen-saturated or oxygen-depleted phases, can be created by water electrolysis depending on the polarity. The functionality of the microsensor can be checked during these microenvironment phases. The polarographic oxygen microsensor is fabricated on a flexible polyimide substrate (Kapton) and the feasibility of the proposed concept is demonstrated in a physiological solution. The sensor responds properly during the oxygen-generating and oxygen- depleting phases. The use of these microenvironments for in situ self-calibration is discussed to achieve functional integration as well as structural integration of the microsensor system.

Kim, Chang-Soo↗

Treatment and Analysis of a Paint Chip from "Water Lilies": A Fire Damaged Monet

A museum fire in 1958 severely damaged a Monet 'Water Lilies' (1916-1926) painting that was on display. The surface of the painting is very dark with areas of blistering and charring. Over the years, traditional techniques have been found to be ineffective at removal of the soot and char from the surface. The painting, which is now in the care of the New York University (NYU) Conservation Center of the Institute of Fine Arts, was the subject of a study to determine if atomic oxygen treatment could remove the soot and char without damaging the fragile painting underneath. For test purposes, a small chip of paint was removed from the edge of the painting by a conservator at NYU and supplied to NASA Glenn Research Center for atomic oxygen treatment and analysis. The diffuse spectral reflectance, at three locations on the paint chip, was monitored at intervals during the atomic oxygen treatment process. Photo documentation of the chip during treatment was also performed. The color contrast was calculated from the spectral reflectance data as a function of treatment duration. Results of the testing indicated that the contrast improved as a result of the treatment, and the differentiation of colors on the surface was significantly improved. Soot and char could be removed without visibly affecting the gross surface features such as impasto areas. These results indicate the feasibility for the treatment of the 'Water Lilies' painting.

Miller, Sharon K. R.↗

Atomic oxygen dosimetry measurements made on STS-46 by CONCAP 2

With increasing flight duration and the possibility of a permanent facility in space, long-term monitoring of material degradation due to atomic oxygen is increasing in importance. Reliance on models to determine the fluence of atomic oxygen is not only necessarily complex but also imprecise due to the strong dependence of oxygen concentration on day/night, latitude and solar activity. Mass-spectroscopy, the traditional method for determining the gas phase species densities at low pressure, is not only expensive but is limited in the area that it can monitor. Our group has developed a simple and inexpensive dosimeter to measure the atomic oxygen fluence via the change in resistance as the sensor element is gradually oxidized. The sensors consisted of thin-film circuit elements deposited on a suitable substrate. Four-point resistance measurements were used to monitor the change in resistance. Results obtained using silver and carbon dosimeters flown on STS-46 (CONCAP 2-01) will be discussed.

Gregory, J. C.↗

A Quadrupole Ion Trap Mass Spectrometer for Quantitative Analysis of Nitrogen-Purged Compartments within the Space Shuttle

To enter orbit, the Space Shuttle burns 1.8 million liters of liquid hydrogen combined with 0.8 million liters of liquid oxygen through three rocket engines mounted in the aft. NASA monitors the nitrogen-purged aft compartment for increased levels of hydrogen or oxygen in order to detect and determine the severity of a cryogenic fuel leak. Current monitoring is accomplished with a group of mass spectrometer systems located as much as 400 feet away from the Shuttle. It can take up to 45 seconds for gas to reach the mass spectrometer, which precludes monitoring for leaks in the final moments before liftoff (the orbiter engines are started at T-00:06 seconds). To remedy the situation, NASA is developing a small rugged mass spectrometer to be used as point-sensors around the Space Shuttle. As part of this project, numerous mass analyzer technologies are being investigated. Presented here are the preliminary results for one such technology, quadrupole ion trap mass spectrometry (QITMS). A compact QITMS system has been developed in-house at the University of Florida for monitoring trace levels of four primary gases, hydrogen, helium, oxygen, and argon, all in a nitrogen background. Since commercially available QITMS systems are incapable of mass analysis at m/z(exp 2), the home-built system is preferred for the evaluation of QITMS technology.

Ottens, Andrew K.↗

Benchmarking Soft Sensors for Remote Monitoring of On-Site Wastewater Treatment Plants

On-site wastewater treatment plants (OSTs) are usually unattended, so failures often remain undetected and lead to prolonged periods of reduced performance. To stabilize the performance of unattended plants, soft sensors could expose faults and failures to the operator. In a previous study, we developed soft sensors and showed that soft sensors with data from unmaintained physical sensors can be as accurate as soft sensors with data from maintained ones. The monitored variables were pH and dissolved oxygen (DO), and soft sensors were used to predict nitrification performance. In the present study, we use synthetic data and monitor three plants to test these soft sensors. We find that a long solids retention time and a moderate aeration rate improve the pH soft-sensor accuracy and that the aeration regime is the main operational parameter affecting the accuracy of the DO soft sensor. We demonstrate that integrated design of monitoring and control is necessary to achieve robustness when extrapolating from one OST to another in the absence of plant-specific fine-tuning. Additionally, we provide a unique labeled dataset for further feature and data-driven soft-sensor development. Our benchmarking results indicate that it is feasible to monitor OSTs with unmaintained sensors and without plant-specific tuning of the developed soft sensors. This is expected to drastically reduce monitoring costs for OST-based sanitation systems.

54 ENVIRONMENTAL SCIENCES↗

Chemical bond reorganization in intramolecular proton transfer revealed by ultrafast X-ray photoelectron spectroscopy

Time-resolved X-ray photoelectron spectroscopy (TR-XPS) is used in a simulation study to monitor the excited state intramolecular proton transfer between oxygen and nitrogen atoms in 2-(iminomethyl)phenol. Real-time monitoring of the chemical bond breaking and forming processes is obtained through the time evolution of excited-state chemical shifts. By employing individual atomic probes of the proton donor and acceptor atoms, we predict distinct signals with opposite chemical shifts of the donor and acceptor groups during proton transfer. Details of the ultrafast bond breaking and forming dynamics are revealed by extending the classical electron spectroscopy chemical analysis to real time. Through a comparison with simulated time-resolved photoelectron spectroscopy at the valence level, the distinct advantage of TR-XPS is demonstrated thanks to its atom specificity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spacecraft Cabin Atmospheric Major Constituent Monitoring Using Off-the-Shelf Techniques

Since the beginning of the crewed space exploration program, the National Aeronautics and Space Administration (NASA) recognized the need to monitor the composition of a spacecraft cabin atmosphere. Typically, major constituent monitoring has been limited to nitrogen, oxygen, carbon dioxide, and water vapor. For the International Space Station, mass spectroscopy was selected as the baseline technology for this task. Recently, new techniques for monitoring major atmospheric constituents have matured commercially making them viable for crewed spacecraft applications. These techniques have advantages over the mass spectroscopy and electrochemically-based instruments used on board the /SS and Shuttle. Fast laser diode oxygen analysis, solid-state infrared carbon dioxide detection, and thin-film capacitive humidity detection are among the emerging techniques. Representative instruments employing these techniques have been selected and tested to demonstrate their potential for crewed spacecraft applications. A summary of testing results is provided.

Perry, Jay L.↗

Results of a Long-Term Demonstration of an Optical Multi-Gas Monitor on ISS

Previously at SAMAP we reported on the development of tunable diode laser spectroscopy (TDLS) based instruments for measuring small gas molecules in real time. TDLS technology has matured rapidly over the last 5 years as a result of advances in low power diode lasers as well as better detection schemes. In collaboration with two small businesses Vista Photonics, Inc. and Nanoracks LLC, NASA developed a 4 gas TDLS based monitor for an experimental demonstration of the technology on the International Space Station (ISS). Vista invented and constructed the core TDLS sensor. Nanoracks designed and built the enclosure, and certified the integrated monitor as a payload. The device, which measures oxygen, carbon dioxide, ammonia and water vapor, is called the Multi-Gas Monitor (MGM). MGM measures the 4 gases every few seconds and records a 30 second moving average of the concentrations. The relatively small unit draws only 2.5W. MGM was calibrated at NASA-Johnson Space Center in July 2013 and launched to ISS on a Soyuz vehicle in November 2013. Installation and activation of MGM occurred in February 2014, and the unit has been operating nearly continuously ever since in the Japanese Experiment Module. Data is downlinked from ISS about once per week. Oxygen and carbon dioxide data is compared with that from the central Major Constituents Analyzer. Water vapor data is compared with dew point measurements made by sensors in the Columbus module. The ammonia channel was tested by the crew using a commercial ammonia inhalant. MGM is remarkably stable to date. Results of 18 months of operation are presented and future applications including combustion product monitoring are discussed.

Mudgett, Paul↗

Data for: Time to anoxia: Observations and predictions of oxygen drawdown following coastal flood events

This dataset contains data and code associated with the paper Patel et al. "Time to anoxia: Observations and predictions of oxygen drawdown following coastal flood events".The coastal terrestrial-aquatic interface (TAI) is a highly dynamic system characterized by strong physical, chemical, and biological gradients. In particular, shifting soil redox conditions and consumption of terminal electron acceptors, due in part to dynamic hydrologic conditions, is a strong driver of carbon availability and transformations across TAIs. However, while redox dynamics are well described, our ability to quantitatively forecast rates of oxic to anoxic shifts in soils with different characteristics and inundation regimes is limited. We integrated field measurements, laboratory incubations, and model simulations to improve mechanistic understanding of oxygen consumption dynamics in coastal soils. Continuous in situ monitoring unexpectedly revealed that flooding caused temporary spikes in subsurface dissolved oxygen followed by rapid consumption in the wetlands. To further investigate these mechanisms in a controlled setting, we performed laboratory incubations using surface and subsurface soils from a TAI gradient (defined here as upland forest to transitional forest to wetland) in Western Lake Erie to measure oxygen consumption rates in TAI soils during flood events. In our experiments, wetland soils reached anoxia the fastest, in ∼ 9 h on average, whereas upland soils turned anoxic in ∼ 18 h. Subsurface upland soils did not turn anoxic even after two weeks of saturation in the lab, and their oxygen consumption patterns suggested carbon and/or nutrient limitation. These results are consistent with in-situ groundwater redox and oxygen measurements in the field, where wetland soils exhibited the highest rates of oxygen consumption along the TAI. Model simulations of oxygen consumption suggested that oxygen consumption had stronger abiotic controls in wetland soils but stronger biotic controls in upland soils, providing a useful framework for future incubation experiments. Microbial activity is a strong driver of oxygen consumption in TAI soils, although it is constrained by the availability of dissolved carbon in subsurface soils.This dataset contains a compressed (.zip) archive of the data and R scripts used for this manuscript. The dataset includes files in .csv format, which can be accessed and processed using MS Excel or R. This archive can also be accessed on GitHub at https://github.com/COMPASS-DOE/cmps-time_to_anoxia (DOI: 10.5281/zenodo.10815374).

54 ENVIRONMENTAL SCIENCES↗

Optimizing Power Reclamation of Micro Hydro Turbines in WWTPs Aeration Basins

Abstract This study investigates the optimum operating conditions and design configurations that can optimize the power reclaimed by small hydro turbines derived by the rising water-bubble current. The rising current is generated by the compressed air introduced by the diffusers at the bottom of aeration basins of Wastewater Treatment Plants (WWTPs). While optimizing the power production, the standard oxygen transfer efficiency (SOTE) is monitored since it is a significant parameter that cannot be sacrificed in the operation of WWTPs. Using one set of turbine blades, it was found out that the highest velocity is obtained in the upper half of the water column (70% - 80%). In contrast, the lowest velocities were obtained just above the air diffuser and at the water surface. Testing started with using a single turbine (ST) to determine the location of the optimum power reclaimed at each tested airflow (1.18, 1.42, 1.65, and 1.89 L/s). Then using double turbine (DT) and triple turbine (TT) to compare their performance to the ST’s maximum power increased power reclamation. The maximum percentage of increase in power reclamation for DT is 19.59%, while it is 20.24% in the case of TT. At a commonly used airflow in WWTPs (1.42 L/s), the optimum configurations of DTs and TTs were selected to investigate the effect of having the proposed setup on the SOTE. For membrane diffusers, DTs and TTs limited the dispersion of the air bubbles in the tank, therefore, reducing the SOTE (8.3% for DT and 3.7% for the TT). The ceramic and sharp-nub diffusers were also tested versus rubber membrane ones to determine the effect of using the ceramic and sharp-nub diffusers on the power reclamation and SOTE. Ceramic diffusers neither achieve higher power reclamation than the membrane nor increases the SOTE. In contrast, sharp-nub diffusers increase the SOTE for all configurations compared to membranes, but this came into account of power reclamation, where sharp-nub diffusers cause a DT and a TT to produce less power than ST does.

Energy & Fuels↗

Sniffer used as portable hydrogen leak detector

Sniffer type portable monitor detects hydrogen in air, oxygen, nitrogen, or helium. It indicates the presence of hydrogen in contact with activated palladium black by a change in color of a thermochromic paint, and indicates the quantity of hydrogen by a sensor probe and continuous readout.

Dayan, V. H.↗

Artificial atmosphere control system

Two-gas control system has been developed which uses existing hardware. Three systems are used for control, monitoring, and safety backup. Pure oxygen will be supplied to maintain safe pressure level should something go wrong.

Rebert, D. R.↗

A study of temporal and radial dependencies of the anomalous helium and oxygen nuclei

The intensity of the low energy anomalous helium and oxygen components has been continuously monitored by telescopes on the Pioneer 10 and IMP 7 and 8 spacecraft since 1972. After a period of relatively small temporal changes at earth between 1972 and 1978, during which it was possible to study the radial gradients of these components out to about 15 AU, large temporal changes were observed in 1978-1980 associated with the onset of the new solar modulation cycle. During this time period the anomalous He and O intensities at Pioneer 10 have decreased by a factor of greater than 10; however, both anomalous components were still present in the summer of 1980 at about 20 AU. At the earth similar large intensity changes have occurred. At Pioneer 10 the relative modulation of He nuclei is about 1.4x that of O nuclei at the same energy/nuc during this time period.

Webber, W. R.↗

A prototype Crew Medical Restraint System (CMRS) for Space Station Freedom

The Crew Medical Restrain System (CMRS) is a prototype system designed and developed for use as a universally deployable medical restraint/workstation on Space Station Freedom (SSF), the Shuttle Transportation System (STS), and the Assured Crew Rescue Vehicle (ACRV) for support of an ill or injured crewmember requiring stabilization and transportation to Earth. The CMRS will support all medical capabilities of the Health Maintenance Facility (HMF) by providing a restraint/interface system for all equipment (advance life support packs, defibrillator, ventilator, portable oxygen supply, IV pump, transport monitor, transport aspirator, and intervenous fluids delivery system) and personnel (patient and crew medical officers). It must be functional within the STS, ACRV, and all SSF habitable volumes. The CMRS will allow for medical capabilities within CPR, ACLS and ATLS standards of care. This must all be accomplished for a worst case transport time scenario of 24 hours from SSF to a definitive medical care facility on Earth. A presentation of the above design prototype with its subsequent one year SSF/HMF and STS/ACRV high fidelity mock-up ground based simulation testing will be given. Also, parabolic flight and underwater Weightless Test Facility evaluations will be demonstrated for various medical contingencies. The final design configuration to date will be discussed with future space program impact considerations.

Johnston, S. L.↗

Temporary arterial shunts to maintain limb perfusion after arterial injury: an animal study

BACKGROUND: Temporary shunt placement can quickly restore perfusion after extremity arterial injury. This study examined the adequacy of limb blood flow with shunt use, non-heparin-bonded shunt patency over prolonged periods, and the safety of this technique. METHODS: Common iliac arteries were divided and 4.0-mm Silastic Sundt shunts placed in 16 anesthetized pigs. Eight (group I) had shunts placed immediately; eight others (group II) were shunted after an hour of limb ischemia and hemorrhagic shock. Physiologic parameters and femoral artery blood flow in both hindlimbs were continuously monitored. Limb lactic acid generation, oxygen utilization, and hematologic and metabolic effects were serially evaluated for 24 hours. RESULTS: Shunts remained patent in 13 of 16 pigs. Shunts thrombosed in two group I animals because of technical errors, but functioned well after thrombectomy and repositioning. Patency could not be maintained in one animal that died from shock. Flow in group I shunted limbs was 57 (+/-11 SD) % of control. For group II animals in shock, shunted limb flow initially averaged 46 +/- 15% of control, but 4 hours after shunt placement, the mean limb blood flow was the same as in group I. Increased oxygen extraction compensated for the lower flow. Lactic acid production was not increased in comparison to control limbs. CONCLUSION: Shunts provided adequate flow in this model of extremity trauma. Correctly placed shunts stayed patent for 24 hours, without anticoagulation, if shunt placement followed resuscitation.

Hindlimb/blood supply/injuries↗

Overview of Materials International Space Station Experiment 7B

Materials International Space Station Experiment 7B (MISSE 7B) is the most recent in a series of experiments flown on the exterior of International Space Station for the purpose of determining the durability of materials and components in the space environment. A collaborative effort among the Department of Defense, the National Aeronautics and Space Administration, industry, and academia, MISSE 7B will be flying a number of NASA experiments designed to gain knowledge in the area of space environmental effects to mitigate risk for exploration missions. Consisting of trays called Passive Experiment Containers, the suitcase sized payload opens on hinges and allows active and passive experiments contained within to be exposed to the ram and wake or zenith and nadir directions in low Earth orbit, in essence, providing a test bed for atomic oxygen exposure, ultraviolet radiation exposure, charged particle radiation exposure, and thermal cycling. New for MISSE 7B is the ability to monitor experiments actively, with data sent back to Earth via International Space Station communications. NASA?s active and passive experiments cover a range of interest for the Agency. Materials relevant to the Constellation Program include: solar array materials, seal materials, and thermal protection system materials. Materials relevant to the Exploration Technology Development Program include: fabrics for spacesuits, materials for lunar dust mitigation, and new thermal control coatings. Sensors and components on MISSE 7B include: atomic oxygen fluence monitors, ultraviolet radiation sensors, and electro-optical components. In addition, fundamental space environmental durability science experiments are being flown to gather atomic oxygen erosion data and thin film polymer mechanical and optical property data relevant to lunar lander insulation and the James Web Space Telescope. This paper will present an overview of the NASA experiments to be flown on MISSE 7B, along with a summary of the thermal environment to be expected during the 1 yr mission scheduled for launch in 2009.

Jaworske, Donald A.↗

Monitoring and control of atmosphere in a closed environment

Applications requiring new technologies for atmosphere monitoring and control in the closed environment and their principal functions aboard the Space Station Freedom are described. Oxygen loop closure, involving the conversion of carbon dioxide to oxygen; carbon dioxide reduction and removal; and monitoring of atmospheric contamination are discussed. The Trace Contaminant Monitor, the Major Constituent Analyzer, the Carbon Dioxide Monitor, and the Particulate Counter Monitor are discussed.

Humphries, R.↗