Search NASA⌕ Search

SEARCH · Search NASA

Results for “particle heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Method to Identify the Heat Flux From Photons and Neutrals at the Divertor Target

The Surface Eroding Thermocouple (SETC) is a diagnostic designed for fast surface heat flux measurement and has been successfully applied in DIII-D to investigate divertor detachment. A novel method has been developed of using a combination of surface-facing and recessed SETCs to distinguish between the heat flux from charged particles, and that from neutrals and radiative heating. Furthermore, this technique suggests that at least 20% of the total incident heat flux is attributable to the latter sources not trapped in the magnetic field in a fully detached open divertor condition. It not only indicates the non-charged particle heating significantly contributes to the total surface heat flux in detached divertor conditions, but also demonstrates the feasibility of using two operational modes of SETCs to distinguish between the two surface heating mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid metal walls

Here, the plasma performance of fusion devices depends strongly on the chosen wall materials. Solid plasma-facing components (PFCs) are predominantly used in present devices, and are the most investigated candidates for fusion designs. High-Z materials such as tungsten (W) are the leading solid PFC material candidates. To date, a material choice that scales to steady-state reactor conditions has not been identified. Moreover, if plasma transient events such as edge-localized modes and disruptions cannot be altogether avoided or sufficiently mitigated, the projected peak heat and particle loads far exceed the power exhaust capabilities of solids. Liquid metal (LM) PFCs represent an intrinsic self-healing boundary that are both resilient to surface damage from transients, and that could handle high steady-state heat and particle fluxes. Flowing LM PFCs can be designed to remove “slag,” the buildup of material erosion due to plasma-material interactions, including charge exchange sputtering in the main chamber. Further, LM offer the prospect to manage hydrogenic species otherwise retained in the PFCs, which is important from a safety and inventory standpoint. The two most promising LMs are lithium (Li) and tin (Sn), although Sn–Li eutectics may be considered. While Sn offers a higher temperature window with low vapor pressure and low hydrogen retention, Li offers the prospect of enhanced energy confinement and higher acceptable core contamination limits, and this section focuses on Li PFCs. An LM PFC development research program developed LM PFC concepts for a nuclear fusion device via engineering design calculations, single-effect experiments, and staged prototypical experiments. A self-consistent design window was identified with liquid Li flow speeds ~5–10 m/s; plasma contamination was negligible for predicted Li evolution rates. While these preconceptual designs hold promise, there is substantial R&D needed to advance the technical readiness levels of LM PFCs for application to fusion power plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Heating in 2D Particle-in-cell Simulations of Quasi-perpendicular Low-beta Shocks

Abstract We measure the thermal electron energization in 1D and 2D particle-in-cell simulations of quasi-perpendicular, low-beta ( β p = 0.25) collisionless ion–electron shocks with mass ratio m i / m e = 200, fast Mach number M ms = 1 –4, and upstream magnetic field angle θ Bn = 55°–85° from the shock normal n ˆ . It is known that shock electron heating is described by an ambipolar, B -parallel electric potential jump, Δ ϕ ∥ , that scales roughly linearly with the electron temperature jump. Our simulations have Δ ϕ ∥ / ( 0.5 m i u sh 2 ) ∼ 0.1 –0.2 in units of the pre-shock ions’ bulk kinetic energy, in agreement with prior measurements and simulations. Different ways to measure ϕ ∥ , including the use of de Hoffmann–Teller frame fields, agree to tens-of-percent accuracy. Neglecting off-diagonal electron pressure tensor terms can lead to a systematic underestimate of ϕ ∥ in our low- β p shocks. We further focus on two θ Bn = 65° shocks: a M s = 4 ( M A = 1.8 ) case with a long, 30 d i precursor of whistler waves along n ˆ , and a M s = 7 ( M A = 3.2 ) case with a shorter, 5 d i precursor of whistlers oblique to both n ˆ and B ; d i is the ion skin depth. Within the precursors, ϕ ∥ has a secular rise toward the shock along multiple whistler wavelengths and also has localized spikes within magnetic troughs. In a 1D simulation of the M s = 4 , θ Bn = 65° case, ϕ ∥ shows a weak dependence on the electron plasma-to-cyclotron frequency ratio ω pe /Ω ce , and ϕ ∥ decreases by a factor of 2 as m i / m e is raised to the true proton–electron value of 1836.

Tran, Aaron (ORCID:0000000334834890)↗

Probing Thermal Transport in Fluidized Bed Using Modulated Photothermal Radiometry

Abstract In concentrated solar power (CSP) applications, fluidized bed is a promising approach for high heat transfer coefficient (HTC) solar receivers and heat exchangers. However, the complexity of multiphase mixing has made it difficult to characterize and analyze the heat transfer mechanism. This paper presents an experimental study on simultaneously characterizing heat transfer in both the near-wall and the bulk regions of a fluidized bed using modulated photothermal radiometry (MPR). The MPR is a non-contact frequency-domain technique using an intensity-modulated laser as the heat source and surface infrared emission as thermometry. The thermal penetration depth of the laser heating is varied by controlling its modulation frequency, and thus the measurement can resolve the near-wall and the bulk thermal resistances. With the MPR technique, we measured fluidized silica sands with a mean size of 164 μm in a vertical channel of 6 mm depth. Our results show that the near-wall thermal resistance is substantially increased with increasing gas velocity, which partially offsets the benefit of higher HTC brought by stronger particle mixing during the fluidization. We also used the MPR to quantify the improvement in particle-wall heat transfer in an inclined channel. We found that an 8° inclination towards the heat exchanging side led to a lower near-wall thermal resistance and a higher HTC at high gas velocities. This work demonstrates that the MPR technique is a useful tool to quantify the important near-wall thermal resistance from a bulk particle bed, which not only advances our understanding of heat transfer in fluidized beds, but may also contribute to the design of fluidized bed heat exchangers with higher HTC.

14 SOLAR ENERGY↗

Continuum kinetic investigation of the impact of bias potentials in the current saturation regime on sheath formation

In this work, we examine sheath formation in the presence of bias potentials in the current saturation regime for pulsed power fusion experiments. It is important to understand how the particle and heat fluxes at the wall may impact the wall material and affect electrode degradation. Here, simulations are performed using the 1X-1V Boltzmann–Poisson system for a proton–electron plasma in the presence of bias potentials ranging from 0 to 10 kV. The results indicate that the sheath near the anode remains generally the same as that of a classical sheath without the presence of a bias potential. However, the sheath near the cathode becomes more prominent with a larger potential drop, a significant decrease in the electron density, and larger sheath lengths. The spatially constant current density increases to a saturation value with the increasing bias potential. For high bias potentials, the material choice needs to consider that the anode faces significantly larger particle and heat fluxes compared to the cathode. In general, the results trend with theory with differences attributed to the simplified assumptions in the theory and the kinetic effects considered in the simulations. Due to the significant computational cost of a well resolved 1X-2V simulation, only one such simulation is performed for the 5 kV case showing higher current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid lithium divertor analysis using coupled plasma material interaction model

A liquid lithium divertor can improve performance of future fusion devices by creating efficient power exhaust and improving the energy confinement via pumping of the hydrogen isotopes. In addition, significantly higher heat fluxes can be handled if controlled vapor shielding is used to redistribute the divertor heat flux over a wider area. Design and optimization of such a system calls for an analysis model which includes a strong two-way coupling between the plasma and divertor material. The incoming plasma heat and particle flux will affect the divertor surface temperature, which is a defining factor of the lithium evaporative and sputtered flux going into the plasma. Results of the coupled model based on the plasma edge code SOLPS-ITER and the computational fluid dynamics (CFD) code ANSYS-CFX will be presented for different configurations. An analytical slab flow model is used as a heat transfer boundary condition for SOLPS, defining particle flux from the wall via calculation of the surface temperature. At the final step, results of the SOLPS analysis are verified using a 3D CFD magnetohydrodynamics (MHD) analysis which uses heat and particle flux from SOLPS as a boundary condition. In addition to plasma heat flux, both analytical and CFD temperature models include several plasma material interaction effects, such as lithium evaporation, condensation and sputtering based on deuterium target flux. New adatom sputtering model based on the available experimental data is presented. Analytical model is expanded to include free surface axisymmetric configurations. Results of parametric studies of the divertor configurations with different lithium inlet temperature and velocity will be presented leading to the optimal design resulting in the lowest possible lithium contamination in the core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Analysis of the Open-Surface Slow Li Flow Divertor and Comparison to the Fast Li Flow Divertor

In the ongoing U.S. project, “Liquid Metal Plasma Facing Components,” sponsored by the U.S. Department of Energy, efforts have been taken to develop two open-surface divertor designs for the Fusion Nuclear Science Facility using liquid lithium (Li) as a heat and particle flux removal media. The main focus of this study is the design and analysis of a slow (~1 mm/s) and thin (<1 mm) open-surface Li flow divertor with a Li-cooled substrate, which is then compared with an earlier design of a fast (up to 10 m/s) and thick (~0.5 cm) Li flow divertor with the substrate cooled with helium. The slow Li flow divertor design is based on the original LiWall concept developed at the Princeton Plasma Physics Laboratory. Such a thin and slow Li layer can remove the particle flux by reducing the recycling flux, while the heat flux is removed mainly through the heat sink located beneath. In the present study, the heat sink is provided through a Li cooling flow inside the substrate of reduced activation ferritic/martensitic steel. By performing a multiphysics analysis with COMSOL that included liquid-metal magnetohydrodynamics (MHD), heat transfer, and structural mechanics, the impact of various factors on the divertor heat removal capability, such as Li flow velocity, MHD effects, and inlet velocity boundary condition, were examined. Based on comparisons of the two divertor designs, it was shown that the fast-flow divertor significantly outperformed the slow-flow design, whose heat removal capability was limited to ~1 to 2 MW/m2.

Jiang, Yuchen [ORNL] (ORCID:0000000283280284)↗

CFD-DEM and PR-DNS studies of low-temperature densely packed beds

Over the past few decades, granular media is gaining attention as a viable option for heat transfer fluids (HTFs). Several research efforts are studying the use of particle-based heat transfer fluids in a wide variety of applications. With this motivation, the current work focusses on analyzing the different heat transfer mechanisms in low-temperature mono-sized densely packed granular media. To study the heat transfer behavior of granular media at different scales, the current work employs a two-way coupled computational strategy. The motion of particles is solved using the Discrete Element Method (DEM) and the interstitial air is solved using a Finite-Volume (CFD) approach. The Open-Source library CFDEM Coupling® is used in the current study to join the Finite Volume PISO solver of OpenFOAM® and the DEM solver of LIGGGHTS®. Typically, particle-particle contact conduction and particle-air convection are the most popular closure models. But recent research identified a different heat transfer phenomenon in packed beds that cannot be identified by conduction or convection models. While closure models were developed to implement this on a CFD-DEM framework, they did not capture the effect of intra-particulate thermal gradients on this phenomenon. Hence the current work also employs Particle-Resolved Direct Numerical Simulations (PR-DNS) to gain valuable insights allowing for the modification of existing models. A new closure model is then proposed here and is implemented in the CFD-DEM framework. This model provides key insights into the different heat transfer mechanism of packed beds.

42 ENGINEERING↗

The heat transfer coefficient associated with a moving packed bed of silica particles flowing through parallel plates

Concentrating Solar Power (CSP) with thermal energy storage has the potential to be a renewable energy technology with long duration, inexpensive energy storage. Higher temperature operation increases the conversion efficiency and reduces the cost of energy storage. Several emerging CSP designs utilize particles as the solar receiver due to their high temperature stability and low cost. In some designs, the particles are also used as the thermal energy storage (TES) media. In either configuration, an energy transfer is required between the hot particles and the working fluid in the power cycle in a Particle-to-Fluid Heat Exchanger (PtFHX). Understanding the heat transfer between a moving packed bed and a stationary surface is critical to the successful design of a PtFHX. In this paper, a test facility is described in which a moving packed bed of silica sand with particle size 100–600 μm is introduced into the channel formed by two parallel plates, one of which is heated. The effective static thermal conductivity of the particles used for the test are separately measured over the entire range of test temperatures. The inlet and outlet bulk temperatures of the particle flow are measured as are the surface temperatures at several axial locations along the centerline of the plate. The result is the measurement of heat transfer coefficient as a function of temperature for several velocities. The uncertainty of the measurements is presented and the results are compared to model results found in the literature.

14 SOLAR ENERGY↗

Reduced order modeling of a fluidized bed particle receiver for concentrating solar power with thermal energy storage

Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.

14 SOLAR ENERGY↗

Pumped Thermal Energy Storage Using Low-Cost Particles and a Fluid Bed Heat Exchanger for Maximum Power Efficiency

Robust, efficient, cost-effective long-duration electricity storage (LDES) solutions can enhance grid resiliency, support existing transmission and distribution infrastructure, and enable a greater share of low-cost, variable alternative energy sources to penetrate the market. To meet this need, the project team at the National Renewable Energy Laboratory developed a transformative LDES system based on pumped thermal energy storage (TES) using low-cost particles and a fluid bed heat exchanger for maximum power efficiency (PUMP). The PUMP system is composed of high-temperature, low-cost particle TES coupled with an advanced pressurized fluid bed heat exchanger (PFB HX) that supports a high-efficiency pumped thermal energy storage (PTES) system integrated with concentrating solar thermal power (CSP). The PUMP project developed and de-risked a PFB HX and particle CSP system intended to be integrated with reversible turbomachinery and a modeling tool to assess PTES cost and performance.

14 SOLAR ENERGY↗

Controlling the size of non-axisymmetric magnetic footprints using resonant magnetic perturbations

The structure of the non-axisymmetric heat load distribution at the divertor plates is determined not only by the toroidal but also from the poloidal spectrum of non-axisymmetric field perturbations. Whether they are intrinsic, like error fields, or they are applied through 3D coils, the non-axisymmetric fields produce complex 3D edge magnetic topologies (footprints) that alter the properties of the heat and particle flux distributions on the divertor target plates. In this manuscript, a study of the impact of applied 3D field poloidal spectrum on the footprint size and structure is done for the DIII-D tokamak using the resistive MHD code M3D-C1 coupled with the field line tracing code TRIP3D. To resolve the impact of the poloidal spectrum of the magnetic perturbation, the relative phase of the two rows of in-vessel 3D coils used to produce both a n = 2 and a n = 3 perturbation is varied, where n is the toroidal harmonic of the magnetic perturbation. This shows that the largest footprint is predicted when the relative phase of the two rows is close to zero, which is also where the resonant coupling with the plasma is maximized. These results suggest that it will be challenging to decouple the footprint size from the requisite resonant coupling for RMP–ELM control. The correlation between the measured heat load and particle flux distributions at the outer divertor plates in DIII-D and the magnetic measurements is in good agreement with the predicted dependence of the magnetic footprint size on the amplitude of the resonant component of the plasma response.

3D fields↗