Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Gamma-Ray and Cosmic Ray Muon Modalities for Cargo Inspection

Screening and inspection of cargo containers are two essential methods to nondestructively examine the contents of shipment. These methods enable the detection of illicit transportation of unauthorized materials such as nuclear and radioactive materials, explosives, drugs, and so on, typically at borders or secure facilities. Although high-energy X-ray transmission is a standard system and is widely used for cargo inspection, the inherent challenges of high false-positive rates and high attenuation factors necessitate the development of complementary techniques that can increase the detection efficiency and accuracy in large and dense materials. Gamma-rays, which possess higher penetration characteristics because of their high energy, offer an alternative nonintrusive modality for cargo scanning. They represent a promising inspection method when compared to X-rays for three reasons: (1) improved ability to detect nuclear and radioactive materials, (2) higher inspection throughput rates, and (3) lower false-positive rates. Currently, there are two main gamma-ray inspection techniques, active and passive interrogation. Active interrogation can be further grouped into (1) gamma-ray transmission imaging and (2) neutron-induced gamma-ray emission detection. Gamma-ray transmission imaging utilizes differences in material densities for mapping the shipment contents and detecting anomalies. It is analogous to the X-ray transmission method; however, the high-energy photons make it more difficult to shield against, which enables more efficient performance in large and dense material inspection. Neutron-induced gamma-ray emission inspection is designed for the detection of nuclear and radioactive material because those materials emit characteristic gamma-rays when they are activated by neutron absorption. On the other hand, passive interrogation techniques rely on high-efficiency detectors to detect radiation emitted from hidden special nuclear or other radioactive materials. Similar to passive interrogation, cosmic ray muon monitoring and imaging are relatively new techniques that do not require external radioactive sources. These techniques have received attention as a potential next-generation radiographic probe to identify illicit transportation of nuclear and radioactive materials in cargo containers. Cosmic ray muons have unique features, (1) much higher energies than X-rays or gamma-rays (on the order of 10−1—104 GeV), (2) enhanced penetration capability, and (3) natural occurrence, thereby eliminating the need for induced radiation sources. These features enable cosmic ray muons to be utilized for detection of special nuclear materials in high-background-noise environments. By analyzing incoming and outgoing muon trajectories, scattering angles, and energies, it has been shown that it would be possible to locate hidden and well-shielded materials in cargo containers via three-dimensional muon tomography images or signal analysis. Gamma-rays, cosmic ray muons, and other nonintrusive cargo inspection modalities are complementary to each other, allowing them to address various cargo inspection conditions (i.e., scanning time, cost, radiation exposure level, and types of target materials). This chapter presents a detailed review of the theoretical fundamentals and technical principles behind the current gamma-ray and cosmic ray muon modalities for cargo inspection. Additionally, critical assessments and suggestions for the future directions to advance the use of gamma and muon modalities are discussed.

Bae, Junghyun↗

Validation of the VUV-reflective coating for next-generation liquid xenon detectors

Abstract Coating detector materials with films highly reflective in the vacuum ultraviolet region improves sensitivity of the next-generation rare-event detectors that use liquid xenon. In this work, we investigate the MgF 2 -Al-MgF 2 coating designed to achieve high reflectance at 175 nm, the mean wavelength of liquid xenon (LXe) scintillation. The coating was applied to an unpolished, passivated copper substrate mimicking a realistic detector component of the proposed nEXO experiment, as well as to two unpassivated substrates with “high” and “average” levels of polishing. After confirming the composition and morphology of the thin-film coating using TEM and EDS, the samples underwent reflectance measurements in LXe and gaseous nitrogen (GN2). Measurements in LXe exposed the coated samples to -100°C for several hours. No peeling of the coatings was observed after several thermal cycles. Polishing is found to strongly correlate with the measured specular reflectance (R spec ). In particular, 5.8(5)% specular spike reflectance in LXe was measured for the realistic sample at 20° of incidence, while the values for similar angles of incidence on the high and average polish samples are 62.3(1.3)% and 27.4(7)%, respectively. At large angles (66°–75°), theR spec in LXe for the three samples increases to 23(5)%, 80(8)%, and 84(18)%, respectively. The R spec at around 45° was measured in both GN2 and LXe for average polish sample and shows a reasonable agreement. Importantly, the total reflectance of the samples is comparable and estimated to be 92(8)%, 85(8)%, and 83(8)% in GN2 for the realistic, average, and high polish samples, respectively. This is considered satisfactory for the next-generation LXe experiments that could benefit from using reflective films, such as nEXO and DARWIN, thus validating the design of the coating.

Instruments & Instrumentation↗

Scene simulation for passive IR systems

The development of large mosaic detector arrays will allow for the construction of staring long wave infrared (LWIR) sensors which can observe large fields of view instantaneously and continuously. In order to evaluate and exercise these new systems, it will be necessary to provide simulated scenes of many moving targets against an infrared clutter background. Researchers are currently developing a projector/screen system. This system is comprised of a mechanical scanner, a diffuse screen, and a miniature blackbody. A prototype of the mechanical scanner, which is comprised of four independently driven scanners, has been designed, fabricated, and evaluated under room and cryogenic vacuum conditions. A large diffuse screen has been constructed and tested for structural integrity under cryogenic/vacuum thermal cycling. Construction techniques have been developed for the fabrication of miniature high-temperature blackbody sources. Finally, a concept has been developed to use this miniature blackbody to produce a spectrally tailorable source.

Holt, J. D.↗

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy↗

Conceptual Design of Passive Neutron Albedo Reactivity and Active Neutron Albedo Reactivity Instruments for Various Arrangements of Pebble Bed Reactor Pebbles

MCNP6 simulations were performed to assess the anticipated capability of the Passive Neutron Albedo Reactivity technique for nuclear safeguards measurements of irradiated pebble/pebbles. Two physical setups were examined. One with a single pebble of three different burnups and one with 27 pebbles in a cube. For all cases the sensitivity to removing all the fissile material was examined. For both of the physical setups, 4 assay cases were examined: (a) singles count rates for which the only source neutrons were the inherent neutrons in the fuel, (b) singles count rates again except this time two relatively weak AmLi sources were placed above and below the top central pebble and the combined effect of both neutron source terms were examined, (c) doubles count rates for which the only source neutrons were the inherent neutrons in the fuel, and (d) doubles count rates again except this time two relatively weak AmLi sources were placed above and below the top central pebble and the combined effect of both neutron source terms were examined. Finally, a few parameters such as Cd near the 3 He tubes were perturbed to see if the results could be improved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unmanned Ground Vehicle Perception Using Thermal Infrared Cameras

The ability to perform off-road autonomous navigation at any time of day or night is a requirement for some unmanned ground vehicle (UGV) programs. Because there are times when it is desirable for military UGVs to operate without emitting strong, detectable electromagnetic signals, a passive only terrain perception mode of operation is also often a requirement. Thermal infrared (TIR) cameras can be used to provide day and night passive terrain perception. TIR cameras have a detector sensitive to either mid-wave infrared (MWIR) radiation (3-5?m) or long-wave infrared (LWIR) radiation (8-12?m). With the recent emergence of high-quality uncooled LWIR cameras, TIR cameras have become viable passive perception options for some UGV programs. The Jet Propulsion Laboratory (JPL) has used a stereo pair of TIR cameras under several UGV programs to perform stereo ranging, terrain mapping, tree-trunk detection, pedestrian detection, negative obstacle detection, and water detection based on object reflections. In addition, we have evaluated stereo range data at a variety of UGV speeds, evaluated dual-band TIR classification of soil, vegetation, and rock terrain types, analyzed 24 hour water and 12 hour mud TIR imagery, and analyzed TIR imagery for hazard detection through smoke. Since TIR cameras do not currently provide the resolution available from megapixel color cameras, a UGV's daytime safe speed is often reduced when using TIR instead of color cameras. In this paper, we summarize the UGV terrain perception work JPL has performed with TIR cameras over the last decade and describe a calibration target developed by General Dynamics Robotic Systems (GDRS) for TIR cameras and other sensors.

terrain classification↗

Probing the surface oxidation process in hexagonal boron nitride epilayers

Thermal neutron detectors based on hexagonal boron nitride ( h -BN) epilayers have demonstrated a record high efficiency among solid-state detectors at 58%. It was found that the performance of h -BN detectors is profoundly influenced by charge recombination at the surfaces. The dynamic process of surface oxidation in h -BN epilayers has been probed by x-ray photoelectron spectroscopy. The spectra of high-resolution (0.1 eV) scans indicated that the linewidth of the B 1s peak at 190.6 eV increased and the peak intensity decreased with an increase in exposure time in-air (t air ). The main B 1s peak at 190.6 eV evolved into multiple peaks at a higher binding energy position due to oxygen impurities tending to occupy nitrogen sites and form the B–O bond. Time constants of the oxidation process have been determined, revealing that the formation process of the B–O bond is very fast and within minutes in h -BN. The results suggest that reducing nitrogen vacancy generation during growth and employing surface treatment techniques would further improve the performance of h -BN devices.

2D materials↗

Multiple-bubble detector

Device is segmented multiple-input detector. Bubbles are fed into each section simultaneously. Detector output is improved by using passive replicators.

George, P. K.↗

The Energetic Transient Array ETA - A network of 'space buoys' in solar orbit for observations of gamma-ray bursts

The Energetic Transient Array (ETA) is a concept for a dedicated interplanetary network of about 40 microsatellites ('space buoys') deployed in an about 1 AU radius solar orbit for the observation of cosmic gamma ray bursts (GRBs). Such a network is essential for the determination of highly accurate (about 0.1 arcsec) error boxes for GRBs. For each of about 100 bursts which would be detectable per year of observation by such a network, high resolution spectra could be obtained through the use of passively-cooled Ge gamma-ray detectors. Stabilization of each microsatellite would be achieved by a novel technique based on the radiation pressure exerted on 'featherable' solar paddles. It should be possible to have a fully functional array of satellites in place before the end of the decade for a total cost of about $20M, exclusive of launcher fees.

Ricker, George R.↗

Cloud Screening and Quality Control Algorithm for Star Photometer Data: Assessment with Lidar Measurements and with All-sky Images

This paper presents the development and set up of a cloud screening and data quality control algorithm for a star photometer based on CCD camera as detector. These algorithms are necessary for passive remote sensing techniques to retrieve the columnar aerosol optical depth, delta Ae(lambda), and precipitable water vapor content, W, at nighttime. This cloud screening procedure consists of calculating moving averages of delta Ae() and W under different time-windows combined with a procedure for detecting outliers. Additionally, to avoid undesirable Ae(lambda) and W fluctuations caused by the atmospheric turbulence, the data are averaged on 30 min. The algorithm is applied to the star photometer deployed in the city of Granada (37.16 N, 3.60 W, 680 ma.s.l.; South-East of Spain) for the measurements acquired between March 2007 and September 2009. The algorithm is evaluated with correlative measurements registered by a lidar system and also with all-sky images obtained at the sunset and sunrise of the previous and following days. Promising results are obtained detecting cloud-affected data. Additionally, the cloud screening algorithm has been evaluated under different aerosol conditions including Saharan dust intrusion, biomass burning and pollution events.

data quality control algorithm↗

Multi-segment detector

A plurality of stretcher detector segments are connected in series whereby detector signals generated when a bubble passes thereby are added together. Each of the stretcher detector segments is disposed an identical propagation distance away from passive replicators wherein bubbles are replicated from a propagation path and applied, simultaneously, to the stretcher detector segments. The stretcher detector segments are arranged to include both dummy and active portions thereof which are arranged to permit the geometry of both the dummy and active portions of the segment to be substantially matched.

George, Peter K.↗

High resolution Doppler lidar

A high resolution lidar system was implemented to measure winds in the lower atmosphere. The wind speed along the line of sight was determined by measuring the Doppler shift of the aerosol backscattered laser signal. The system in its present configuration is stable, and behaves as indicated by theoretical simulations. This system was built to demonstrate the capabilities of the detector system as a prototype for a spaceborne lidar. The detector system investigated consisted of a plane Fabry-Perot etalon, and a 12-ring anode detector. This system is generically similar to the Fabry-Perot interferometer developed for passive wind measurements on board the Dynamics Explorer satellite. That this detector system performs well in a lidar configuration was demonstrated.

Abreu, Vincent J.↗

Long-Wavelength Infrared (LWIR) Quantum Dot Infrared Photodetector (QDIP) Focal Plane Array

We have exploited the artificial atomlike properties of epitaxially self-assembled quantum dots for the development of high operating temperature long wavelength infrared (LWIR) focal plane arrays. Quantum dots are nanometer-scale islands that form spontaneously on a semiconductor substrate due to lattice mismatch. QDIPs are expected to outperform quantum well infrared detectors (QWIPs) and are expected to offer significant advantages over II-VI material based focal plane arrays. QDIPs are fabricated using robust wide bandgap III-V materials which are well suited to the production of highly uniform LWIR arrays. We have used molecular beam epitaxy (MBE) technology to grow multi-layer LWIR quantum dot structures based on the InAs/InGaAs/GaAs material system. JPL is building on its significant QWIP experience and is basically building a Dot-in-the-Well (DWELL) device design by embedding InAs quantum dots in a QWIP structure. This hybrid quantum dot/quantum well device offers additional control in wavelength tuning via control of dot-size and/or quantum well sizes. In addition the quantum wells can trap electrons and aide in ground state refilling. Recent measurements have shown a 10 times higher photoconductive gain than the typical QWIP device, which indirectly confirms the lower relaxation rate of excited electrons (photon bottleneck) in QDPs. Subsequent material and device improvements have demonstrated an absorption quantum efficiency (QE) of approx. 3%. Dot-in-the-well (DWELL) QDIPs were also experimentally shown to absorb both 45 deg. and normally incident light. Thus we have employed a reflection grating structure to further enhance the quantum efficiency. JPL has demonstrated wavelength control by progressively growing material and fabricating devices structures that have continuously increased in LWIR response. The most recent devices exhibit peak responsivity out to 8.1 microns. Peak detectivity of the 8.1 micrometer devices has reached approx. 1 x 10(exp 10) Jones at 77 K. Furthermore, we have fabricated the first long-wavelength 640x512 pixels QDP focal plane array. This QDIP focal plane may has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60K operating temperature. In addition, we have managed to increase the quantum efficiency of these devices from 0.1% (according to the data published in literature) to 20% in discrete devices. This is a factor of 200 increase in quantum efficiency. With these excellent results, for the first time QDIP performance has surpassed the QWIP performance. Our goal is to operate these long-wavelength detectors at much higher operating temperature than 77K which can be passively achieved in space. This will be a huge leap in high performance infrared detectors specifically applicable to space science instruments.

infrared imaging↗

Vacuum UV performance of silicon detectors

The sensitivity, time-varying response, and spatial sensitivity of four silicon detectors of vacuum UV were measured by passing a typical flux of 3 x 10 photons/s at the Lyman alpha line of 1215.7 A through an exit aperture of 0.55 mm x 0.8 mm. The detectors tested were: (1) a Fairchild FPM 200 silicon planar passivated photodiode with the window removed so that radiation could directly impinge on the center of the 1.0 mm square silicon chip, (2) a Fairchild FPM 100 silicon NPN planar passivated phototransistor, (3) the Hewlett-Packard 5082-4204 silicon planar PIN photodiode, and (4) the United Detector Technology PIN Spot/2 special sensitive silicon Schottky surface photodiode with the window removed.

Ohlhaber, R. L.↗

Radiation Measured with Different Dosimeters for ISS-Expedition 18-19/ULF2 on Board International Space Station during Solar Minimum

Radiation field of particles in low Earth orbit (LEO) is mainly composed of galactic cosmic rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). GCR are modulated by solar activity, at the period of solar minimum activity, GCR intensity is at maximum and the main contributor for space radiation is GCR. At present for space radiation measurements conducted by JSC (Johnson Space Center) SRAG (Space Radiation Analysis Group), the preferred active dosimeter sensitive to all LET (Linear Energy Transfer) is the tissue equivalent proportional counter (TEPC); the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. For the method using passive dosimeters, radiation quantities for all LET can be obtained by combining radiation results measured with TLDs/OSLDs and CR-39 PNTDs. TEPC, TLDs/OSLDs and CR-39 detectors were used to measure the radiation field for the ISS (International Space Station) - Expedition 18-19/ULF2 space mission which was conducted from 15 November 2008 to 31 July 2009 - near the period of the recent solar minimum activity. LET spectra (differential and integral fluence, absorbed dose and dose equivalent) and radiation quantities were measured for positions TEPC, TESS (Temporary Sleeping Station, inside the polyethylene lined sleep station), SM-P 327 and 442 (Service Module - Panel 327 and 442). This paper presents radiation LET spectra measured with TEPC and CR-39 PNTDs and radiation dose measured with TLDs/OSLDs as well as the radiation quantities combined from results measured with passive dosimeters.

Zhou, Dazhuang↗

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Surface-Defect-Passivation-Enabled Near-Unity Charge Collection Efficiency in Bromide-Based Perovskite Gamma-Ray Spectrum Devices

Hybrid lead halide perovskites have superior charge transport properties to all-inorganic perovskites, but high-resolution spectroscopic radiation detectors have not been realized. Here we show that surface deep traps severely limit charge collection in formamidinium lead bromide (FAPbBr3) single-crystal devices, despite having a good bulk transport property. Three types of defect on the crystal surface, namely, FA vacancies, uncoordinated lead and Pb-Pb dimers caused by bromide loss, are found to form deep traps, resulting in non-radiative charge recombinations at the metal/perovskite interface. By tailoring the passivation functional groups, we find that ammonium bromide can passivate all these three deep traps on FAPbBr3 surfaces, improving the charge collection efficiency to near unity. The comparable bulk and surface recombination lifetimes indicate that all the surface defects are effectively passivated. Surface passivation also reduces the dark current by 10 times and decreases the dark counts by ~60 times. The energy resolution of the 137Cs spectra acquired using the FAPbBr3 detectors is improved from 5.7% to 1.7% when all the surface defects are passivated without changing the bulk properties, which is the best among solution-grown semiconductor detectors. Surface passivation is stable for more than six months, and FAPbBr3 spectroscopic detectors can operate at unprecedented high temperatures of more than 130 degrees C.

gamma ray↗

In situ orbital debris experiment concepts

Implementation of the radar, lidar and passive optical remote sensing concepts for measuring space debris from an Earth orbiting platform was investigated. Each system was compared for their requirements on the host platform, their performance relative to the space debris measurement program and the estimated cost of developing each concept into a flight instrument. It is found that the radar and lidar systems offer the greatest versatility and accuracy since they control the direction, intensity and duration of the energy incident on the target object. The performance of the passive optical system is determined by the capability of the detector and by the baseline separation of the telescopes, which requires the use of an on-orbit deployment mechanism. The passive optical concept provides the largest total event rae, and includes significant detections of particle sizes greater than 10 cm to allow correlation with ground based observations of the larger particles. The event rate for the radar system is relatively constant with particle while the lidar system is slightly biased toward the smaller sizes. These event rate differences result from a combination of the debris flux size distribution and the variation of sensitive detection area with particle size for the three concepts.

Neste, S. L.↗