Explore the source record for details and available documents.
This project addresses a fundamental flaw in solar PV research and solar project financing; the assumed rate of degradation for solar plants. The solar industry currently relies on an out-dated report that observed a 0.5% degradation rate based on a small sample size of systems (~100). While the research conducted at the time was new and innovative, the solar community has not updated this research and universally applies this 0.5% degradation assumption in financial models. Our project updates this assumption by analyzing observed degradation from the industry’s largest dataset of operating solar assets (>10,000 systems) and creating the first machine-learning model based on these observed results to quantify and identify features that drive degradation. There are two strategic goals for this award: reduce the cost of capital (enable solar to attract more capital) and improve the reliability of solar itself. These dual goals are achieved by leveraging an industry dataset to observe system degradation on a large scale, deploying advanced data analysis and machine learning methods to quantify and predict system reliability, and engaging with industry stakeholders to help them accurately price degradation in financial models.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Small Scale WEC Performance Modeling Data is performance data from downscaled models of common WEC devices and their calculated performance outputs. This data is used by the Small WEC interactive modeling tool hosted by PRIMRE. The devices include a point absorber, a two-body point absorber (RM3), an oscillating surge device (OSWEC), and an attenuator type device (McCabe Wave Pump). One of the primary use cases for this work is to give an easy way to compare power output for a variety of WECs and model sizes.
A new data mining algorithm was developed to identify the strongest correlations between capacitance data (measured between -1.5 V and +0.49 V) and 1st and 2nd level performance metrics (efficiency, open-circuit voltage (VOC), short-circuit current density (JSC), and fill-factor (FF)) during the stress testing of voltage-stabilized CdS/CdTe devices. When considering only correlations between 1stand 2nd level metrics, 96.5% of the observed variation in efficiency was attributed to FF. The overall decrease in VOC after 1000 hours of open-circuit, light-soak stress at 60 degrees C was about 1.5%. As determined by our algorithm, the most consistent correlation existing between FF and 3rd level metric capacitance data at all stages during stress testing was between FF and the apparent CdTeacceptor density (Na) calculated at a voltage of +0.49 V during forward voltage scans. Since the contribution of back contact capacitance to total capacitance increases with increasing positive voltage, this result suggests that FF degradation is associated with decreases in Na near the CdTe/back contact interface. Also of interest, it appears that capacitance data at these higher voltagesappears to more accurately fit the one-sided abrupt junction model.
As data centers proliferate in size and number, the improvement of their energy efficiency and productivity has become an economic and environmental imperative. Making these improvements requires metrics that are robust, interpretable, and practical. We discuss the properties of a number of the proposed metrics of energy efficiency and productivity. In particular, we focus on the Data Center Energy Productivity (DCeP) metric, which is the ratio of useful work produced by the data center to the energy consumed performing that work. We describe our approach for using DCeP as the principal outcome of a designed experiment using a highly instrumented, high-performance computing data center. We found that DCeP was successful in clearly distinguishing different operational states in the data center, thereby validating its utility as a metric for identifying configurations of hardware and software that would improve energy productivity. We also discuss some of the challenges and benefits associated with implementing the DCeP metric, and we examine the efficacy of the metric in making comparisons within a data center and between data centers.
A techno-economic analysis is underway examining the cost and performance of future large-scale photovoltaic (PV) plant components, including bifacial modules, tandem modules, increased plant voltage architectures, and module-level power electronics. Integration of these components into PV plant designs is compared with current PV technologies based on levelized cost of electricity (LCOE). Baseline models are developed and validated against recorded PV plant performance data. Expected cost and performance data of future PV technologies are incorporated into the baseline models. An evolutionary algorithm is utilized to optimize PV plant configuration, technology combination, and LCOE. Furthermore, this paper focuses on the bifacial module analysis.
A device for copying performance counter data includes hardware path that connects a direct memory access (DMA) unit to a plurality of hardware performance counters and a memory device. Software prepares an injection packet for the DMA unit to perform copying, while the software can perform other tasks. In one aspect, the software that prepares the injection packet runs on a processing core other than the core that gathers the hardware performance data.
Abstract Not Provided
A device for copying performance counter data includes hardware path that connects a direct memory access (DMA) unit to a plurality of hardware performance counters and a memory device. Software prepares an injection packet for the DMA unit to perform copying, while the software can perform other tasks. In one aspect, the software that prepares the injection packet runs on a processing core other than the core that gathers the hardware performance counter data.
Increases in data volumes are forcing high-energy and nuclear physics experiments to store more frequently accessed data on tape. Extracting the maximum performance from tape drives is critical to make this viable from a data availability and system cost standpoint. The nature of data ingest and retrieval in an experimental physics environment make achieving high access performance difficult given the inherent limitations of magnetic tape. Tailoring the layout of data on tape is one key to improving read performance. This paper highlights the work in progress to characterize ATLAS data ingested in the tape system, understand how data layout, i.e. file co-location on tape and file distribution over tapes, affect read performance and how optimal data layout might be achieved in a production environment.